HC-12 AT Commands List and Usage

This document provides a comprehensive guide to the AT commands used with the HC-12
communication module, including a list of commands, configuration details.

Command Description Default Value Example Usage

AT Test if the module responds. N/A AT

AT+RX Enter receive mode (default communication N/A AT+RX


mode).

AT+VERSION Check the firmware version of the module. N/A AT+VERSION

AT+Bxxxx Set the baud rate for serial communication 9600 bps AT+B9600

AT+Cxxxx Set the communication channel (frequency) 433.4 MHz AT+C001

AT+FUx Set the communication mode (FU1, FU2, FU3 AT+FU3


FU3, FU4)

AT+Px Set the transmission power level (P1 to P8) P8 (20dBm AT+P5

AT+SLEEP Put the module into sleep mode to save N/A AT+SLEEP
power.

AT+DEFAULT Restore the factory default settings. N/A AT+DEFAULT

AT+UPDATE Update the module’s firmware (only for N/A AT+UPDATE


factory use).

How to Use AT Commands with ESP32


1. Connect the HC-12 to the ESP32 as follows:
- GND -> GND

- VCC -> 3.3V

- RX -> GPIO 19

- TX -> GPIO 18

- SET -> GPIO 5

AT Commands Usage Examples

Example 1: Change Baud Rate


To change the baud rate of the HC-12 module, use the command 'AT+Bxxxx'. For example, to
set the baud rate to 9600, enter the following in the Serial Monitor:

AT+B9600

Response: OK+B9600

Example 2: Set Channel


To set the communication channel (frequency), use the command 'AT+RFy', where 'y' is the
channel number (1-127). For example, to set the channel to 10, enter the following:

AT+RF010

Response: OK+RF010

Example 3: Set Transmission Power


To set the transmission power level, use the command 'AT+Px', where 'x' is a number from
1 to 8 (8 being the highest). For example, to set the power level to 5, use:

AT+P5

Response: OK+P5

AT+C002
433.4 MHz+(2−1)×0.4 MHz=433.8 MHz

AT+C001 1 433.4
AT+C002 2 433.8

AT+C003 3 434.2

AT+C004 4 434.6

AT+C005 5 435.0

AT+C006 6 435.4

AT+C007 7 435.8

AT+C008 8 436.2

AT+C009 9 436.6

AT+C010 10 437.0

AT+C011 11 437.4

AT+C012 12 437.8

AT+C013 13 438.2

AT+C014 14 438.6

AT+C015 15 439.0

AT+C016 16 439.4

AT+C017 17 439.8

AT+C018 18 440.2

AT+C019 19 440.6

AT+C020 20 441.0

AT+C021 21 441.4

AT+C022 22 441.8

AT+C023 23 442.2

AT+C024 24 442.6

AT+C025 25 443.0

AT+C026 26 443.4
AT+C027 27 443.8

AT+C028 28 444.2

AT+C029 29 444.6

AT+C030 30 445.0

AT+C031 31 445.4

AT+C032 32 445.8

AT+C033 33 446.2

AT+C034 34 446.6

AT+C035 35 447.0

AT+C036 36 447.4

AT+C037 37 447.8

AT+C038 38 448.2

AT+C039 39 448.6

AT+C040 40 449.0

AT+C041 41 449.4

AT+C042 42 449.8

AT+C043 43 450.2

AT+C044 44 450.6

AT+C045 45 451.0

AT+C046 46 451.4

AT+C047 47 451.8

AT+C048 48 452.2

AT+C049 49 452.6

AT+C050 50 453.0
AT+C051 51 453.4

AT+C052 52 453.8

AT+C053 53 454.2

AT+C054 54 454.6

AT+C055 55 455.0

AT+C056 56 455.4

AT+C057 57 455.8

AT+C058 58 456.2

AT+C059 59 456.6

AT+C060 60 457.0

AT+C061 61 457.4

AT+C062 62 457.8

AT+C063 63 458.2

AT+C064 64 458.6

AT+C065 65 459.0

AT+C066 66 459.4

AT+C067 67 459.8

AT+C068 68 460.2

AT+C069 69 460.6

AT+C070 70 461.0

AT+C071 71 461.4

AT+C072 72 461.8

AT+C073 73 462.2

AT+C074 74 462.6
AT+C075 75 463.0

AT+C076 76 463.4

AT+C077 77 463.8

AT+C078 78 464.2

AT+C079 79 464.6

AT+C080 80 465.0

AT+C081 81 465.4

AT+C082 82 465.8

AT+C083 83 466.2

AT+C084 84 466.6

AT+C085 85 467.0

AT+C086 86 467.4

AT+C087 87 467.8

AT+C088 88 468.2

AT+C089 89 468.6

AT+C090 90 469.0

AT+C091 91 469.4

AT+C092 92 469.8

AT+C093 93 470.2

AT+C094 94 470.6

AT+C095 95 471.0

AT+C096 96 471.4

AT+C097 97 471.8

AT+C098 98 472.2
AT+C099 99 472.6

AT+C100 100 473.0