Calculation of Heat Balance

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

会 签

IMO 号 船名
IMO NUMBER 9569633 SHIP'S NAME
SONATA
工程号
上海外高桥船舶及海洋工程设计研究院 HULL NO. H1223
SHANGHAI WAIGAOQIAO MARINE DESIGN & RESEARCH INSTITUTE 设计阶段 FINISHED PLAN
DES. STA.

设绘DWN. 319,000吨原油轮 图 号 DWG NO.

校对CHK.
319,000 DWT CRUDE OIL TANKER 5M684001MB
标检CER. 版本号 REV.
热平衡计算
审核APP.1 比例 SC. 重量WT/kg

审定APP.2 CALCULATION OF HEAT BALANCE 第 1 页 PAGE NO. 共 4 页 TOTAL

批准AGR. 主办及电话MAS.&TEL 孔芸婕/5942

面 积 AREA 0.0625 m2
CALCULATION OF HEAT H1223 TOTAL 4
SWD BALANCE 5M684001MB PAGE 2

1. GENERAL

THE ESTIMATED COOLING WATER AMOUNT AND HEAT DISSIPATION FOR THE MACHINERY &
EQUIPMENT TO BE IN ACCORDANCE WITH MAKER'S INFORMATION IN GENERAL

THE CENTRALIZED COOLING SYSTEM CONSISTS OF :


ONE (1) SET OF M/E JACKET F.W COOLER (100% CAPACITY OF TOTAL HEAT DISSIPATION)
TWO (2) SETS OF CENTRAL F.W COOLER (60% CAPACITY OF TOTAL HEAT DISSIPATION)
TWO (2) SETS OF M/E JACKET COOLING F.W PUMP
THREE (3) SETS OF CENTRAL COOLING F.W PUMP
TWO (2) SETS OF VACUUM CONDENSER COOLING S.W PUMP

2. MAIN EQUIPMENT (FOR CALCULATION)

1) MAIN ENGINE

TYPE : Wartsila 7RT-flex82T

NO. OF SET : ONE(1)

MCR : 31,640 kW x 80 RPM

NCR : 26,894 kW x 75.8 RPM

2) AUX. ENGINE

TYPE : FOUR STROKE, TRUNK PISTON IN-LINE

NO. OF SET : THREE (3)

RATING : 1550KW x 900RPM

3. OPERATING CONDITION OF COOLING SYSTEM

S.W. CRUDE OIL TANK LOAD


NO CONDITION TEMP REMRKS
(℃) A/E
HEATING CLEANING M/E (%)
(SET %)

1 DESIGN MAX. 40 - - 100 2 * 100 -

NOTE :
1. THE LOAD OF A/E CAN BE ADJUSTED ACCORDING TO ELEC. LOAD BALANCE.
2. THE EXCESS STEAM GENERATED BY AUXILIARY BOILER DURING I.G TOPPING UP AT SEA
SHALL BE DUMPED INTO THE VACUUM CONDENSER.

-2-
CALCULATION OF HEAT H1223 TOTAL 4
SWD BALANCE 5M684001MB PAGE 3

4. INSTALLATION OF PUMPS

Q'TY CAPACITY TOTAL HEAD


NO. DESCRIPTION REMARKS
/SHIP (㎥/H) (mTH)
VACUUM CONDENSER
1 2 1,600 12 EACH 50%
COOLING S.W PUMP

2 MAIN COOLING S.W PUMP 3 950/1600 20/12 EACH 50%

3 L.T COOLING F.W PUMP 3 860 30 EACH 50%

4 M/E JACKET COOL. F.W PUMP 2 270 30 EACH 100%

5 A/E JACKET COOL. F.W PUMP 3 34 - ENGINE ATTACHED

THE CAPACITY OF VACUUM CONDENSER IS BASED ON SEA WATER TEMPERATURE OF 27℃.

5. INSTALLATION OF COOLERS AND CONDENSERS

Q'TY HOT FLUID COOLING FLUID REMARKS


NO. DESCRIPTION /SHI (HEAT DISSI.
Q'TY INLET OUTLE Q'TY INLET OUTLET
P ㎉/H)/SET
(㎥/H) (℃) T (㎥/H) (℃) (℃)

CENTRAL F.W COOLER


1 2 860 50.9 40 950 36 48.3 11,293,090
(Each 60%) *See Note 2

2 MAIN L.O COOLER 1 510 57.40 45 400 40 46.5 2,236,000

3 S/T L.O COOLER 1 1.0 47.43 40 3.6 40 40.8 2,477

6.63
ATMOS. STEAM 120 60
T/H
4 DUMP DRAIN 1 480 40 50.3 4,251,840
CONDENSER COND. 2.3 T/H 165 60
WATER 1.4 T/H 120 60

5 VACUUM CONDENSER 1 100.9 471.6 69.6 3200 32 48.9 46,591,360

6 M/E JACKET F.W CLR 1 270 85.0 70.7 262 46.5 61.3 3,334,736

NOTE : 1. THE SPECIFICATION OF ATMOS. DRAIN/DUMP. CONDENSER SHOWS THE HEAT DISSIPATION
AT THE PORT WITH CARGO HANDLING CONDITION. (WINTER CONDITION)
2. EACH CENTRAL F.W COOLER IS TO BE PROVIDED WITH THE 60% OF TOTAL HEAT
DISSIPATION AT MAX. DESIGN CONDITION. BUT, STEEL FRAME SIZE TO BE SATISFIED WITH
100%. * HEAT DISSIPATION OF CENTRAL F.W CLR (60%) : 13,131 kW (11,293,090 Kcal/hr)
3. THE CLEAN. FACTORS FOR TUBULAR AND PLATE TYPE SHALL BE 85% & 90% RESPECTIVELY.
4. FLUID PROPERTIES BASED ON TECHNICAL BUILDING SPECIFICATION

SPECIFIC GRAVITY SPECIFIC HEAT TEMPERATURE


DESCRIPTION
(㎏/㎥) (㎉/㎏.°c) (°C)

FRESH WATER 1,000 1 40

SEA WATER 1,025 0.94 36

LUBRICATING OIL 900 0.45 45

-3-
H1223 TOTAL 4
SWD CALCULATION OF HEAT BALANCE
5M684001MB PAGE 4
SYMBOL 1) DESIGN MAX. 565.8 Q

Q: ㎥/H 61.0 T
T : DEG. C.
KW : 860 KCAL/H 400 Q MAIN L.O. COOLER 138.0 181.0 Q 3 AIR CONDITION UNIT
PREHEATER 262 Q 3029.0 KW 46.5 T 427.8 810.0 KW 43.8 T
M/E JACKET 46.5 T 402 Q M/E AIR COOLER 65.6 300.0 Q ATMOSPHERIC CONDENSER
12608.0 KW 67.0 T 4711.0 KW 53.5 T
3.6 Q S/T L.O COOLER
270.0 Q 3.5 KW 40.8 T 19.6 Q PROV. REF. PLAN
MAIN ENGINE 70.7 T 6.0 Q NO.1 MAIN AIR COMP. 36.0 KW 41.6 T
Wartsila 75.0 KW 50.8 T
7RT-flex82T 6.0 Q NO.2 MAIN AIR COMP. 105.0 Q NO.1&NO.2&NO.3 C.O.P.T.L.O. COOLER
KW 40.0 T 150.0 KW 41.2 T
50.0 Q NO.1&NO.2 B.W.P.T.L.O. COOLER
3.1 Q NO.2 MAIN AIR COMP. 70.0 KW 41.2 T
M/E J.C.F.W. PUMP 262 Q 4.0 KW 40.7 T 17.6 Q UNIT COOLER FOR ECR
270.0 Q 270 ㎥/Hx30 MTH 61.3 T 69.8 KW 43.4 T
85.0 T 4.8 Q TOPPING-UP AIR COMP. 17.6 Q UNIT COOLER FOR WORKSHOP
(1 set) 51.0 KW 49.1 T 69.8 KW 43.4 T
4492.0 KW 1.7 Q SERVICE AIR COMP. 22.6 Q UNIT COOLER FOR GALLEY
3.6 KW 41.8 T 90.8 KW 43.5 T
M/E J.F.W 0.7 Q CONTROL AIR COMP.
COOLER 1.6 KW 42.1 T 30.0 Q T.C.P.T L.O COOLER
40.0 T 40.0 KW 41.1 T
F.W.
GENERATOR 1.0 Q BOILER CIR. PUMP COOLER
LOW TEMP. COOLING F.W. PUMP 41.0 KW 75.3 T
1,672.2 Q 860 ㎥/H x 30 MTH
1310.2
1310 2 Q
1672.2 Q 48.2 T
50.9 T
50.0 Q NO.1 G/E AIR/L.O. COOLER
100.0 Q 565.0 KW 49.7 T
60.3 T
NO.2 CENTRAL NO.1 CENTRAL
F.W. COOLER (60%) F.W. COOLER (60%) 44.0 Q NO.1 G/E JACKET
13131.5 KW 13131.5 KW 73.0 T 360.0 KW
48.3 T 950 Q 48.3 T 950 Q
1900 Q 36.0 T 36.0 T
48.3 T 80.0 T

1900 Q 50.0 Q NO.2 G/E AIR/L.O. COOLER


36.0 T 50.0 Q 565.0 KW 49.7 T
60.3 T

44.0 Q NO.2 G/E JACKET


1900 Q 73.0 T 360.0 KW
3200 Q 3170 Q C.O.P.T. CONDENSER 3170 Q 36.0 T
49.5 T 49.5 T 62130.0 KW 32.0 T
30 Q AIR EJECTOR CONDENSER 30 Q 80.0 T
45.7 T 460.0 KW 32.0 T
0.0 Q NO.3 G/E AIR/L.O. COOLER
0.0 Q 0.0 KW 0.0 T
0.0 T

0.0 Q NO.3 G/E JACKET


0.0 T 0.0 KW
SEA CHEST

SEA CHEST 0.0 T


C.O.P.T. VACUUM CONDENSER C.S.W. P MAIN S.W. PUMP
1600 ㎥/Hx10 MTH 950/1600㎥/Hx20/10 MTH