STR - Starting System
STR - Starting System
STR - Starting System
SECTION
STARTING SYSTEM
STR STR
E
CONTENTS
PRECAUTION ............................................... 2 Diagnosis Procedure ...............................................20 F
DIAGNOSIS AND REPAIR WORK FLOW ........18 SERVICE DATA AND SPECIFICATIONS O
Work Flow ............................................................... 18 (SDS) ............................................................ 34
DTC/CIRCUIT DIAGNOSIS ......................... 20 SERVICE DATA AND SPECIFICATIONS
(SDS) ................................................................. 34 P
B TERMINAL CIRCUIT ......................................20 Starter Motor ...........................................................34
STR-1 GETtheMANUALS.org
PRECAUTIONS
< PRECAUTION >
PRECAUTION
PRECAUTIONS
Precaution for Supplemental Restraint System (SRS) "AIR BAG" and "SEAT BELT
PRE-TENSIONER" INFOID:0000000010430883
The Supplemental Restraint System such as “AIR BAG” and “SEAT BELT PRE-TENSIONER”, used along
with a front seat belt, helps to reduce the risk or severity of injury to the driver and front passenger for certain
types of collision. Information necessary to service the system safely is included in the “SRS AIR BAG” and
“SEAT BELT” of this Service Manual.
WARNING:
Always observe the following items for preventing accidental activation.
• To avoid rendering the SRS inoperative, which could increase the risk of personal injury or death in
the event of a collision that would result in air bag inflation, all maintenance must be performed by
an authorized NISSAN/INFINITI dealer.
• Improper maintenance, including incorrect removal and installation of the SRS, can lead to personal
injury caused by unintentional activation of the system. For removal of Spiral Cable and Air Bag
Module, see “SRS AIR BAG”.
• Never use electrical test equipment on any circuit related to the SRS unless instructed to in this Ser-
vice Manual. SRS wiring harnesses can be identified by yellow and/or orange harnesses or harness
connectors.
PRECAUTIONS WHEN USING POWER TOOLS (AIR OR ELECTRIC) AND HAMMERS
WARNING:
Always observe the following items for preventing accidental activation.
• When working near the Air Bag Diagnosis Sensor Unit or other Air Bag System sensors with the
ignition ON or engine running, never use air or electric power tools or strike near the sensor(s) with
a hammer. Heavy vibration could activate the sensor(s) and deploy the air bag(s), possibly causing
serious injury.
• When using air or electric power tools or hammers, always switch the ignition OFF, disconnect the
battery, and wait at least 3 minutes before performing any service.
Precaution for Stop/Start System Service INFOID:0000000010430885
CAUTION:
When performing an inspection and its related work with the engine at idle, always open the hood and
release the stop/start system.
Precautions for Removing Battery Terminal INFOID:0000000010503205
• With the adoption of Auto ACC function, ACC power is automatically supplied by operating the intelligent key
or remote keyless entry or by opening/closing the driver side door. In addition, ACC power is supplied even
after the ignition switch is turned to the OFF position, i.e. ACC power is supplied for a certain fixed time.
• When disconnecting the 12V battery terminal, turn off the ACC
power before disconnecting the 12V battery terminal, observing
“How to disconnect 12V battery terminal” described below.
NOTE:
Some ECUs operate for a certain fixed time even after ignition
switch is turned OFF and ignition power supply is stopped. If the
battery terminal is disconnected before ECU stops, accidental DTC
detection or ECU data damage may occur.
• For vehicles with the 2-batteries, be sure to connect the main bat-
tery and the sub battery before turning ON the ignition switch.
NOTE:
SEF289H
If the ignition switch is turned ON with any one of the terminals of
main battery and sub battery disconnected, then DTC may be detected.
• After installing the 12V battery, always check "Self Diagnosis Result" of all ECUs and erase DTC.
NOTE:
The removal of 12V battery may cause a DTC detection error.
STR-2 GETtheMANUALS.org
PRECAUTIONS
< PRECAUTION >
HOW TO DISCONNECT 12V BATTERY TERMINAL
Disconnect 12V battery terminal according to instruction described below. A
1. Open the hood.
2. Turn ignition switch to the ON position.
3. Turn ignition switch to the OFF position with the driver side door opened. STR
4. Get out of the vehicle and close the driver side door.
5. Wait at least 3 minutes. For vehicle with the engine listed below, remove the battery terminal after a lapse
of the specified time.
C
D4D engine : 20 minutes
HRA2DDT : 12 minutes
K9K engine : 4 minutes D
M9R engine : 4 minutes
R9M engine : 4 minutes
V9X engine : 4 minutes E
CAUTION:
While waiting, never operate the vehicle such as locking, opening, and closing doors. Violation of
this caution results in the activation of ACC power supply according to the Auto ACC function. F
6. Remove 12V battery terminal.
CAUTION:
After installing 12V battery, always check self-diagnosis results of all ECUs and erase DTC. G
STR-3 GETtheMANUALS.org
PREPARATION
< PREPARATION >
PREPARATION
PREPARATION
Commercial Service Tools INFOID:0000000010430887
PIIB1407E
STR-4 GETtheMANUALS.org
COMPONENT PARTS
< SYSTEM DESCRIPTION >
SYSTEM DESCRIPTION A
COMPONENT PARTS
Component Parts Location INFOID:0000000010430888
STR
JMBIA4642ZZ K
STR-5 GETtheMANUALS.org
COMPONENT PARTS
< SYSTEM DESCRIPTION >
Starter motor INFOID:0000000010430889
The starter motor plunger closes and the motor is supplied with bat-
tery power, which in turn cranks the engine, when the “S” terminal is
supplied with electric power.
JMBIA4360ZZ
STR-6 GETtheMANUALS.org
SYSTEM
< SYSTEM DESCRIPTION >
SYSTEM
A
STARTING SYSTEM
STARTING SYSTEM : System Description INFOID:0000000010430891
STR
SYSTEM DIAGRAM
CVT Models C
H
JMBIA4623GB
MT Models
For Europe and Russia I
N
JMBIA4622GB
STR-7 GETtheMANUALS.org
SYSTEM
< SYSTEM DESCRIPTION >
Except for Europe and Russia
JMBIA4641GB
NOTE:
For models without stop/start system, starter motor “B” terminal is connect to battery directly.
SYSTEM DESCRIPTION
CVT Models
• “B” terminal is constantly supplied with battery power*.
• When selector lever is P or N, power is supplied to starter control relay by transmission range switch.
• When starter operating condition is satisfied, IPDM E/R turns starter control relay ON by starter control relay
control signal.
• When engine cranking condition is satisfied, BCM turns starter relay ON by starter relay control signal.
• Then battery power is supplied to starter motor (“S” terminal) through starter relay and starter control relay.
M/T Models
STR-8 GETtheMANUALS.org
STARTING SYSTEM
< WIRING DIAGRAM >
WIRING DIAGRAM A
STARTING SYSTEM
Wiring Diagram INFOID:0000000010430892
STR
JRBWD1447GB
STR-9 GETtheMANUALS.org
STARTING SYSTEM
< WIRING DIAGRAM >
JRBWD1448GB
STR-10 GETtheMANUALS.org
STARTING SYSTEM
< WIRING DIAGRAM >
STR
JRBWD1449GB
STR-11 GETtheMANUALS.org
STARTING SYSTEM
< WIRING DIAGRAM >
JRBWD1450GB
STR-12 GETtheMANUALS.org
STARTING SYSTEM
< WIRING DIAGRAM >
STR
JRBWD1451GB
STR-13 GETtheMANUALS.org
STARTING SYSTEM
< WIRING DIAGRAM >
JRBWD1452GB
STR-14 GETtheMANUALS.org
STARTING SYSTEM
< WIRING DIAGRAM >
STR
JRBWD1453GB
STR-15 GETtheMANUALS.org
STARTING SYSTEM
< WIRING DIAGRAM >
JRBWD1454GB
STR-16 GETtheMANUALS.org
STARTING SYSTEM
< WIRING DIAGRAM >
STR
JRBWD1455GB
STR-17 GETtheMANUALS.org
STARTING SYSTEM
< WIRING DIAGRAM >
JRBWD1456GB
STR-18 GETtheMANUALS.org
DIAGNOSIS AND REPAIR WORK FLOW
< BASIC INSPECTION >
BASIC INSPECTION A
DIAGNOSIS AND REPAIR WORK FLOW
Work Flow INFOID:0000000010430894
STR
DETAILED FLOW
NOTE: C
If any malfunction is found, immediately disconnect the battery cable from the negative terminal.
CAUTION:
For models with stop/start system, erase the starter operation counter when the starter motor connec-
tor is disconnected. Refer to ECH-120, "Work Procedure" (HR engine), ECK-146, "Work Procedure" D
(K9K engine), EC9-155, "Work Procedure" (R9M engine) or ECM-203, "Work Procedure" (MR16DDT
engine).
1.CHECK ENGINE TYPE E
Type Engine F
HR engine
K9K engine
1 G
R9M engine
MR16DDT engine
2 MR20DD engine H
>> GO TO 2.
I
2.CHECK ENGINE START
Crank the engine and check that the engine starts.
Does the engine start? J
YES >> GO TO 3.
NO >> GO TO 4.
K
3.CHECK THAT THE STARTER MOTOR STOPS
Check that the starter motor stops after starting the engine.
Does the starter motor stop? L
YES >> INSPECTION END
NO-1 >> Type 1: Replace starter motor.
NO-2 >> Type 2: Replace magnetic switch. M
4.CHECK THE ENGINE SPEED WITH CRANKING
Check that the engine runs at cranking.
N
Does engine turn by cranking?
YES >> GO TO 5.
NO >> GO TO 6.
O
5.CHECK THE ENGINE SPEED WITH CRANKING
Check that the engine speed is not low at cranking.
Does engine turn normally? P
YES >> Check ignition/fuel system.
NO >> Check charge condition, corrosion and connection condition of the battery. Refer to PG-147,
"Work Flow WITHOUT STOP/START SYSTEM".
6.CHECK STARTER MOTOR ACTIVATION
Check that the starter motor runs at cranking.
Does starter motor turn?
STR-19 GETtheMANUALS.org
DIAGNOSIS AND REPAIR WORK FLOW
< BASIC INSPECTION >
YES-1 >> Type 1: Replace starter motor.
YES-2 >> Type 2: GO TO 7.
NO >> GO TO 8.
7.CHECK STARTER MOTOR UNIT
1. Remove starter motor.
2. Check that the gear shaft of starter motor rotates.
Does gear shaft turn?
YES >> Check pinion clutch. Refer to STR-29, "MR20DD : Inspection".
NO >> Check reduction gear, armature and gear shaft.
8.CHECK POWER SUPPLY CIRCUIT
Check the following conditions.
• Fuse and fusible link
• Charge condition, corrosion and connection condition of the battery. Refer to PG-147, "Work Flow WITH-
OUT STOP/START SYSTEM".
Are these inspection results normal?
YES >> GO TO 9.
NO >> Repair as needed.
9.CHECK STARTING SYSTEM WIRING
Check the following.
• “B” terminal circuit. Refer to STR-21, "Diagnosis Procedure".
• “S” terminal circuit. Refer to STR-23, "Diagnosis Procedure".
Are these inspection results normal?
YES-1 >> Type 1: Replace starter motor.
YES-2 >> Type 2: GO TO 10.
NO >> Repair as needed.
10.CHECK MAGNETIC SWITCH OPERATION SOUND
Check that a magnetic switch operation sound can be heard when the ignition switch is set at the starting posi-
tion.
Does magnetic switch operation sound occur?
YES >> GO TO 11.
NO >> Replace magnetic switch.
11.PINION AND RING GEAR ENGAGEMENT CHECK
Check condition of pinion and ring gear mesh.
Is the inspection result normal?
YES >> GO TO 13.
NO >> GO TO 12.
12.CHECK STARTER MOTOR UNIT
Check the following.
• Adjust pinion movement. Refer to STR-29, "MR20DD : Inspection".
• Check pinion moving mechanism.
• Check ring gear.
Are these inspection results normal?
YES >> INSPECTION END
NO >> Repair or replace, if necessary.
13.CHECK STARTER MOTOR UNIT
Check that the starter motor runs when connecting the positive terminal (12 V) to starter motor terminal M and
the negative terminal (ground) to starter motor body.
Does the starter motor run?
YES >> Replace magnetic switch.
NO >> Repair starter motor.
STR-20 GETtheMANUALS.org
B TERMINAL CIRCUIT
< DTC/CIRCUIT DIAGNOSIS >
DTC/CIRCUIT DIAGNOSIS A
B TERMINAL CIRCUIT
Diagnosis Procedure INFOID:0000000010430895
STR
CAUTION:
• Perform diagnosis under the condition that engine cannot start by the following procedure.
- Remove fuel pump fuse. C
- Crank or start the engine (where possible) until the fuel pressure is released.
• For models with stop/start system, erase the starter operation counter when the starter motor con-
nector is disconnected. Refer to ECH-120, "Work Procedure" (HR engine), ECK-146, "Work Proce- D
dure" (K9K engine), EC9-155, "Work Procedure" (R9M engine) or ECM-203, "Work Procedure"
(MR16DDT engine).
1.CHECK “B” TERMINAL CIRCUIT 1 E
1. Turn ignition switch OFF.
2. Check that starter motor “B” terminal connection is clean and tight.
3. Check voltage between starter motor “B” terminal and ground. F
Except for MR engine
(+)
Starter motor (–) Voltage (Approx.) G
Connector Terminal
F105 2 Ground Battery voltage
H
For MR engine
(+)
Starter motor (–) Voltage (Approx.) I
Connector Terminal
E70 2 Ground Battery voltage
J
Is the inspection result normal?
YES >> GO TO 2.
NO-1 >> For models with stop/start system: GO TO 4.
NO-2 >> For models without stop/start system: Check harness between battery and starter motor for open K
circuit.
2.CHECK BATTERY CABLE CONNECTION STATUS (VOLTAGE DROP TEST) L
1. Shift selector lever to “P” or “N” position. (CVT models)
Keep depressing clutch pedal fully. (M/T models)
2. Check voltage between battery positive terminal and starter motor “B” terminal.
M
Except for MR engine
(–)
Starter motor Condition Voltage (Approx.) N
(+)
Connector Terminal
When the ignition switch Less than
Battery positive terminal F105 2
is in START position 0.5 V O
For MR engine
(–)
Starter motor Condition Voltage (Approx.)
P
(+)
Connector Terminal
When the ignition switch Less than
Battery positive terminal E70 2
is in START position 0.5 V
Is the inspection result normal?
YES >> GO TO 3.
NO >> Check harness between the battery and the starter motor for poor continuity.
STR-21 GETtheMANUALS.org
B TERMINAL CIRCUIT
< DTC/CIRCUIT DIAGNOSIS >
3.CHECK GROUND CIRCUIT STATUS (VOLTAGE DROP TEST)
1. Shift selector lever to “P” or “N” position. (CVT models)
Keep depressing clutch pedal fully. (M/T models)
2. Check voltage between starter motor case and battery negative terminal.
Terminals
Condition Voltage (Approx.)
(+) (–)
When the ignition switch is in
Starter motor case Battery negative terminal Less than 0.2 V
START position
Is the inspection result normal?
YES >> “B” terminal circuit is OK. Further inspection is necessary. Refer to STR-19, "Work Flow".
NO >> Check the starter motor case and ground for poor continuity.
4.CHECK “B” TERMINAL CIRCUIT 2
1. Disconnect starter connector and engine restart bypass relay connector.
2. Check continuity between starter motor harness connector and engine restart bypass relay harness con-
nector.
Except for MR16DDT engine
Starter motor Engine restart bypass relay
Continuity
Connector Terminal Connector Terminal
F105 2 F147 2 Existed
STR-22 GETtheMANUALS.org
S TERMINAL CIRCUIT
< DTC/CIRCUIT DIAGNOSIS >
S TERMINAL CIRCUIT
A
Diagnosis Procedure INFOID:0000000010430896
CAUTION: STR
• Perform diagnosis under the condition that engine cannot start by the following procedure.
- Remove fuel pump fuse.
- Crank or start the engine (where possible) until the fuel pressure is released.
• For models with stop/start system, erase the starter operation counter when the starter motor con- C
nector is disconnected. Refer to ECH-120, "Work Procedure" (HR engine), ECK-146, "Work Proce-
dure" (K9K engine), EC9-155, "Work Procedure" (R9M engine) or ECM-203, "Work Procedure"
(MR16DDT engine). D
1. CHECK “S” TERMINAL CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect starter motor connector. E
3. Shift selector lever to “P” or “N” position. (CVT models)
Keep depressing clutch pedal fully. (M/T models)
4. Check voltage between starter motor harness connector and ground. F
Except for MR engine
(+)
Starter motor (–) Condition Voltage (Approx.) G
Connector Terminal
When the ignition switch is in
F104 1 Ground
START position
Battery voltage H
For MR engine
(+)
I
Starter motor (–) Condition Voltage (Approx.)
Connector Terminal
When the ignition switch is in J
F106 1 Ground Battery voltage
START position
Is the inspection result normal?
YES >> “S” terminal circuit is OK. Further inspection is necessary. Refer to STR-19, "Work Flow". K
NO >> GO TO 2.
2.CHECK HARNESS CONTINUITY (OPEN CIRCUIT) L
1. Disconnect IPDM E/R connector.
2. Check continuity between starter motor harness connector and IPDM E/R harness connector.
Except for MR engine M
Starter motor IPDM E/R
Continuity
Connector Terminal Connector Terminal
F104 1 F88 65 Existed N
For MR engine
Starter motor IPDM E/R
Continuity O
Connector Terminal Connector Terminal
F106 1 F88 65 Existed
Is the inspection result normal? P
YES >> Further inspection is necessary. Refer to SEC-78, "Work Flow" (With Intelligent Key System) or
SEC-237, "Work Flow" (Without Intelligent Key System).
NO >> Repair or replace harness.
STR-23 GETtheMANUALS.org
STARTING SYSTEM
< SYMPTOM DIAGNOSIS >
SYMPTOM DIAGNOSIS
STARTING SYSTEM
Symptom Table INFOID:0000000010430897
Symptom Reference
No normal cranking
Refer to STR-19, "Work Flow".
Starter motor does not rotate
STR-24 GETtheMANUALS.org
STARTER MOTOR
< REMOVAL AND INSTALLATION >
REMOVAL AND INSTALLATION A
STARTER MOTOR
HRA2DDT
STR
HRA2DDT : Exploded View INFOID:0000000010324198
H
JMBIA4573GB
REMOVAL
L
1. Disconnect the battery cable from the negative terminal. Refer to PG-154, "Exploded View".
2. Drain engine coolant from radiator. Refer to CO-12, "Draining".
CAUTION:
Perform this step when engine is cold. M
3. Remove intake manifold. Refer to EM-26, "Removal and Installation".
4. Disconnect water hose from water inlet.
N
5. Remove “B” terminal nut and “B” terminal harness.
6. Remove “S” terminal nut and “S” terminal harness.
7. Remove starter motor mounting bolts. O
8. Remove starter motor forward from the vehicle.
INSTALLATION
Note the following items, and then install in the reverse order of removal. P
CAUTION:
• Be careful to tighten “B” terminal nut to the specified torque.
• Erase the starter operation counter when the starter motor for models with STOP/START SYSTEM is
removed or replaced. Refer to ECH-120, "Work Procedure".
• Replace the engine restart relay and the fuel pump relay when the starter motor models with STOP/
START SYSTEM is replaced.
MR16DDT
STR-25 GETtheMANUALS.org
STARTER MOTOR
< REMOVAL AND INSTALLATION >
MR16DDT : Exploded View INFOID:0000000011732944
REMOVAL
PKIC8095E
REMOVAL
1. Disconnect the battery cable from the negative terminal. Refer to PG-155, "Removal and Installation".
2. Remove intake monifold. Refer to EM-151, "Removal and Installation".
3. Open “B” terminal cover, in the direction indicated by an arrow
as shown in the figure.
JMBIA3020ZZ
STR-26 GETtheMANUALS.org
STARTER MOTOR
< REMOVAL AND INSTALLATION >
7. Disconnect harness connector (1) from crankshaft position sen-
sor. A
8. Remove harness fixing clip (A) from oil pan (upper), and then
move harness (2) to a location where they do not inhibit work.
STR
JMBIA3021ZZ
D
9. Remove starter motor mounting bolts.
10. Remove starter motor from the vehicle.
CAUTION: E
For models with STOP/START SYSTEM, never erase the starter operation counter except when
replacing starter motor.
INSTALLATION F
Note the following items, and install in the reverse order of removal.
CAUTION:
• Be careful to tighten “B” terminal nut to the specified torque.
G
• Erase the starter operation counter when the starter motor for models with STOP/START SYSTEM is
replaced. Refer to ECM-203, "Work Procedure".
• Replace the engine restart bypass relay and the fuel pump relay when the starter motor models with
STOP/START SYSTEM is replaced. H
- Engine restart bypass relay: Refer to ECM-619, "Removal and Installation".
- Fuel pump relay (IPDM E/R): Refer to PCS-68, "Removal and Installation".
MR20DD I
J
REMOVAL
JMBIA4561GB
P
1. “S” terminal connector 2. Starter motor 3. Cylinder block
: Vehicle front
STR-27 GETtheMANUALS.org
STARTER MOTOR
< REMOVAL AND INSTALLATION >
DISASSEMBLY
JMBIA4574GB
REMOVAL
1. Disconnect the battery cable from the negative terminal. Refer to PG-154, "Exploded View".
2. Disconnect the oil pressure switch connector.
3. Remove “B” terminal nut and “B” terminal harness.
4. Remove “S” terminal nut and “S” terminal harness.
5. Remove starter motor mounting bolts.
6. Remove starter motor upward from the vehicle.
CAUTION:
Never damage oil pressure switch when removing starter motor.
INSTALLATION
Note the following item, and then install in the reverse order of removal.
CAUTION:
Be careful to tighten “B” terminal nut to the specified torque.
STR-28 GETtheMANUALS.org
STARTER MOTOR
< REMOVAL AND INSTALLATION >
MR20DD : Disassembly and Assembly INFOID:0000000010376821
A
ASSEMBLY
Apply high-temperature grease to lubricate the bearing, gears and frictional surface when assembling
the starter. STR
Carefully observe the following instructions.
Pinion Protrusion Length Adjustment
C
CLEARANCE
• With pinion driven out by magnetic switch, push pinion back to
remove slack and measure clearance “L” between the front edge
of the pinion and the pinion stopper. D
SKIB0229E
G
• Adjust with the adjusting plate if the measurement value is not in
the specified area.
J
PKID0786E
K
INSPECTION
Magnetic Switch Check
• Before starting to check, disconnect the battery cable from the negative terminal. L
• Disconnect “M” terminal of starter motor.
1. Continuity test [between “S” terminal (A) and switch body]
M
B : “B” terminal
C : “M” terminal
N
• Replace magnetic switch if continuity does not exist.
SKIB9002E
P
STR-29 GETtheMANUALS.org
STARTER MOTOR
< REMOVAL AND INSTALLATION >
2. Continuity test [between “S” terminal (A) and “M” terminal (C)]
B : “B” terminal
SKIB9003E
Pinion/Clutch Check
1. Inspect pinion teeth.
• Replace pinion if teeth are worn or damaged. (Also check con-
dition of ring gear teeth.)
2. Inspect reduction gear teeth (If equipped).
• Replace reduction gear if teeth are worn or damaged. (Also
check condition of armature shaft gear teeth.)
3. Check to see if pinion locks in one direction and rotates
smoothly in the opposite direction.
• Replace pinion assembly if it is locked or rotated in both direc-
tions or unusual resistance is evident.
SEL630BA
Brush Check
SEL014Z
SEL015Z
STR-30 GETtheMANUALS.org
STARTER MOTOR
< REMOVAL AND INSTALLATION >
1. Perform insulation test between brush holder (positive side) and
its base (negative side). A
• Replace brush holder assembly if continuity does not exist.
2. Check brush to see if it moves smoothly.
• If brush holder is bent, replace it; if sliding surface is dirty, STR
clean.
SKIB0460E
D
Yoke Check
Magnet is secured to yoke by bonding agent. Check magnet to see
that it is secured to yoke and for any cracks. Replace malfunctioning
parts as an assembly. E
CAUTION:
Never clamp yoke in a vise or strike it with a hammer.
F
G
SEL305H
Armature Check H
1. Continuity test (between two segments side by side)
• Replace armature assembly if continuity does not exist.
2. Insulation test (between each commutator bar and shaft) I
• Replace armature assembly if continuity exists.
K
SKIB0461E
SEL020Z O
STR-31 GETtheMANUALS.org
STARTER MOTOR
< REMOVAL AND INSTALLATION >
4. Check diameter of commutator.
SEL021Z
SEL022Z
K9K
K9K : Exploded View INFOID:0000000010324190
JMBIA4570GB
STR-32 GETtheMANUALS.org
STARTER MOTOR
< REMOVAL AND INSTALLATION >
REMOVAL D
1. Disconnect the battery cable from the negative terminal. Refer to PG-154, "Exploded View".
2. Remove air inlet tube. Refer to EM-428, "Exploded View".
3. Disconnect the fuel rail pressure (FRP) sensor harness connec- E
tor (1).
JMBIA4599ZZ
H
STR-33 GETtheMANUALS.org
STARTER MOTOR
< REMOVAL AND INSTALLATION >
R9M : Exploded View INFOID:0000000010324196
JMBIA4245GB
REMOVAL
1. Remove the battery and battery tray. Refer to PG-155, "Removal and Installation".
2. Remove the ECM (TCM) bracket and ECM (TCM). Refer to TM-632, "Removal and Installation".
3. Remove the harness bracket mounting nuts ( ) and remove
the harness bracket (1) from the vehicle.
JSDIA5410ZZ
STR-34 GETtheMANUALS.org
STARTER MOTOR
< REMOVAL AND INSTALLATION >
9. Remove harness bracket (1).
A
: Vehicle front
STR
JMBIA4601ZZ
D
10. Remove “B” terminal nut (A) and “B” terminal harness.
11. Remove “S” terminal nut (B) and “S” terminal harness.
12. Remove starter motor mounting bolts. E
13. Remove starter motor (1) downward from the vehicle.
CAUTION:
For models with STOP/START SYSTEM, never erase the
F
starter operation counter except when replacing starter
motor.
G
: Vehicle front
H
JMBIA4602ZZ
INSTALLATION
Note the following items, and then install in the reverse order of removal. I
CAUTION:
• Be careful to tighten “B” terminal nut to the specified torque.
• Erase the starter operation counter when the starter motor for models with STOP/START SYSTEM is J
replaced. Refer to EC9-155, "Work Procedure".
• Replace the engine restart relay and the fuel pump relay when the starter motor models with STOP/
START SYSTEM is replaced.
K
STR-35 GETtheMANUALS.org
SERVICE DATA AND SPECIFICATIONS (SDS)
< SERVICE DATA AND SPECIFICATIONS (SDS)
SERVICE DATA AND SPECIFICATIONS (SDS)
SERVICE DATA AND SPECIFICATIONS (SDS)
Starter Motor INFOID:0000000010201146
Engine HR K9K
M000TD0371 M000TD0375 M000T46571 0 001 170 605
Type MITUBISHI make BOSCH make
Reduction gear type
System voltage [V] 12
Terminal voltage [V] 11.5 —
No-load Current [A] Less than 110 Less than 110 Less than 40 —
Revolution [rpm] More than 2,800 More than 2,800 More than 5,000 —
Minimum diameter of commutator [mm (in)] — — — —
Minimum length of brush [mm (in)] — — — —
Brush spring tension [N (kg, lb)] — — — —
Clearance between bearing metal
[mm (in)] — — — —
and armature shaft
Clearance “L” between pinion front
[mm (in)] — — — —
edge and pinion stopper
STR-36 GETtheMANUALS.org