The amount of current flow to the solenoid is controlled by the ECM. During the lock-up operation, if the current increases, the lock-up
hydraulic pressure increases.
MONITOR DESCRIPTION
When an open or short in the shift solenoid valve SLU circuit is detected, the ECM determines that there is a malfunction. The ECM will
illuminate the MIL and store the DTC.
WIRING DIAGRAM
INSPECTION PROCEDURE
1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)
Standard Resistance:
Specified
Tester Connection Condition
Condition
17 (SLU+) - 6
20°C (68°F) 5.0 to 5.6 Ω
(SLU-)
17 (SLU+) - Body
Always 10 kΩ or higher
ground
6 (SLU-) - Body
Always 10 kΩ or higher
ground
Text in Illustration
Component without harness connected
*a
(Transmission Wire)
NG Go to step 3
OK
Standard Resistance:
Specified
Tester Connection Condition
Condition
C29-33 (SLU+) -
20°C (68°F) 5.0 to 5.6 Ω
C29-32 (SLU-)
C29-33 (SLU+) -
Always 10 kΩ or higher
Body ground
C29-32 (SLU-) -
Always 10 kΩ or higher
Body ground
Text in Illustration
Front view of wire harness connector
*a
(to ECM)
OK
Standard Resistance:
Specified
Tester Connection Condition
Condition
1-2 20°C (68°F) 5.0 to 5.6 Ω
c. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and
makes an operating noise.
OK:
Measurement Condition Specified Condition
Battery positive
(+) with a 21 W
bulb → Terminal Valve moves and makes an
2 operating noise
Battery negative
(-) → Terminal 1
Text in Illustration
Component without harness connected
*a
(Shift Solenoid Valve SLU)
OK