DIAGRAMA MONTANTE DE INSTALACIONES ELECTRICAS (I.E.I.

ELECTRICO TELEFONICO INTERCOMUNICADOR TELECABLE Y ANTENA INTERNET


TECHO

AZOTEA

T
SC(a) SC(a) 1 TP. 4 TV. 4 TI.
1 INT.
T.D.-3 TP 100X100X50mm 100X100X50mm TV 100X100X50mm TI 100X100X50mm

T
SC(a) SC(a) 5ta PLANTA

T
T

T
1 TP. 1 INT. 4 TV. 4 TI.
SC(a) SC(a)
T.D.-3 TP 100X100X50mm 100X100X50mm TV 100X100X50mm TI 100X100X50mm

4ta PLANTA
T

T
1 TP. 1 INT. 4 TV. 4 TI.

T.D.-3 TP 100X100X50mm 100X100X50mm TV 100X100X50mm TI 100X100X50mm

T
T

T
3ra PLANTA
1 Tubo: 2-1x4mm2 LSOH+(T)
Ø25mm-PVC_P 1 TP. 1 INT. 4 TV. 4 TI.

TP 100X100X50mm 100X100X50mm TV 100X100X50mm TI 100X100X50mm


T.D.-2

T
SC(a) SC(a) 2da PLANTA
SC(a) SC(a)

2 Tubos: 2-1x4mm2 LSOH+(T)


Ø25mm-PVC_P
T

T
1 TP. 1 INT. 4 TV. 4 TI.
Acometida de la Red Principal
TP 100X100X50mm 100X100X50mm TV 100X100X50mm TI 100X100X50mm
T T
(Medidores Trifasicos)
5 Tubos: 3 x 16 mm2 THW + 1 x 10 mm2
T T
N2XOH Ø 35mm PVC-SAP

CAJA TOMA
T.G. T.D.-1
T

T
1 2 3

1 Tubos: 3-1 x 10mm2 THW + 6mm2 T/T

T
E B
1ra. PLANTA
Alarma
PAT
4 Tubos: 3 x 16 mm2 THW + 1 x 10 mm2 Nivel de Parada
SC(a) SC(a)
N2XOH Ø 35mm PVC-SAP
T

T
SC(a) SC(a) Nivel de Arranque
SC(a) SC(a)
Puesta a Tierra

SUBE ENERGIA ELECTRICA: SUBE ENERGIA ELECTRICA:


DE TG A TD-3 (2-1x6mm2 N2XOH+1x6mm2 CPT) DE TG A TD-3 (2-1x6mm2 N2XOH+1x6mm2 CPT)
2(Ø25 mm PVC SAP) 2(Ø25 mm PVC SAP) TG TD-01
(PRIMER PISO) (PRIMER PISO)
2x25A
2x20A
C-1 INSTALACION EXISTENTE ALUMBRADO
T

T
C-1 2x30A 2-1x6mm2 N2XOH + 1x6mm2 CPT PVC-SAPTD-a
25mm 2x30A 30mA
2x25A
Ø 2x20A
C-2 INSTALACION EXISTENTE TOMACORRIENTE
30mA 30mA

220V, 1Ø, 60 Hz.


T

T
4 Polos

TD-a
(PRIMER PISO)
2x25A
2x20A
C-1 ELECTROBOMBA
2-1x4mm2 NH-80 + 1x4mm2 CPT PVC-SAP 20mm Ø 1HP
30mA
2x25A
C-2 2x20A 2-1x4mm2 NH-80 + 1x4mm2 CPT PVC-SAP 20mm Ø
ALUMBRADO
30mA
2x25A
2x25A 2-1x4mm2 N2XOH + 1x4mm2 CPT PVC-SAPTD-1
25mm 2x30A 2x20A
C-2 C-3 2-1x4mm2 NH-80 + 1x4mm2 CPT PVC-SAP 20mm
TOMACORRIENTE
Ø
SUBE ENERGIA ELECTRICA:
T

T
Ø 30mA

DE TG A TD-3 (2-1x6mm2 N2XOH+1x6mm2 CPT) RESERVA


220V, 1Ø, 60 Hz.
SC(a) 2(Ø25 mm PVC SAP) 8 Polos

T TD-02
(SEGUNDO PISO) 2x25A
4SC(a) 4SC(a) C-1 2x15A 2-1x2.5mm2 NH-80 + 1x2.5mm2 CPT PVC-SAPALUMBRADO
20mm
30mA Ø
2x25A
T T C-3 2x30A 2-1x6mm2 N2XOH + 1x6mm2 CPT PVC-SAPTD-2
25mm 2x30A
C-2 2x20A 2-1x4mm2 NH-80 + 1x4mm2 CPT PVC-SAP 20mm
TOMACORRIENTE
Ø
Ø 30mA
SC(a)
SC(a) RESERVA
SC(a) SC(a)
(2-1x10mm2 N2XOH + 220V, 1Ø, 60 Hz.
SC(a) SC(a)
VIENE EE.EE. 2x60A 6 Polos
1x10mm2 CPT (T))
SC(a) SC(a)
DE EMPRESA kwh (Ø35 mm PVC SAP)
SC(a) SC(a) SC(a)
SC(a)
CONCESIONARIA MEDIDOR DE TD-03
(TERCER PISO) 2x25A
ENERGIA ELECTRICA C-1 2x15A 2-1x2.5mm2 NH-80 + 1x2.5mm2 CPT PVC-SAPALUMBRADO
20mm
SC(a) SC(a)
T T
SC(a)
MONOFASICO 30mA Ø
(M-01) C-4 2x30A 2-1x6mm2 N2XOH + 1x6mm2 CPT PVC-SAPTD-3
25mm 2x30A
2x25A
C-2 2x20A TOMACORRIENTE
2-1x4mm2 NH-80 + 1x4mm2 CPT PVC-SAP 20mm Ø
Ø 30mA
T T

T
RESERVA
220V, 1Ø, 60 Hz.
6 Polos

TD-4
(AZOTEA) 2x25A
C-1 2x15A 2-1x2.5mm2 NH-80 + 1x2.5mm2 CPT PVC-SAPALUMBRADO
20mm
30mA Ø
C-5 2x30A 2-1x6mm2 N2XOH + 1x6mm2 CPT PVC-SAPTD-4
25mm 2x30A
2x25A
C-2 2x20A 2-1x4mm2 NH-80 + 1x4mm2 CPT PVC-SAP 20mm
TOMACORRIENTE
Ø
Ø 30mA

RESERVA
220V, 1Ø, 60 Hz.
6 Polos

RESERVA

T T
DETALLE DE ZANJAS
T T PARA CABLES
SUBTERRANEOS

DETALLE DE EMPALMES EN INTERRUPTOR


CAJA DE PASO OCTOGONAL TERMOMANETICO INTERRUPTOR
UNIPOLAR TERMOMANETICO
1x.... A TRIPOLAR
3x.... A

ESPECIFICACIONES TECNICAS 1/2


1/2 5/6
3/4
SIMBOLO DESCRIPCION MATERIAL DETALLE DE LUMINARIAS CABLE
2/1
2/1
4/3
6/5
TABLERO GENERAL Y/O DISTRIBUCION : CONECTOR
TIPO
- CAJA, PARA EMPOTRAR EN MURO, DEL TIPO METALICO SOMBRERO 1x... A
- PUERTA Y CHAPA, ACABADO CON PINTURA MARTILLADO IGUAL 3x... A
A LO FABRICADO POR TIANON, J.J.CASTRO Y/O LUMITEX
- BARRAS Y ACCESORIOS : DEBEN IR AISLADAS DE TODO DEL GABINETE
LAS BARRAS SERAN DE COBRE ELECTROLITICO DE LAS SGTES.
CAPACIDADES:
INTERRUPTOR GENERAL BARRAS CABLE TERMINAL
HASTA 100amp. 200 A. PVC
- INTERRUPTORES TIPO AUTOMATICO (THERMOMAGNETICO) IGUAL ARTEFACTO TIPO FLUORESCENTE EN CAJA
A WESTINGHOUSE(USA), GENERAL (USA), ETC. ANTORCHA MOD. E - 35 CON REJILLA MOD. ARA

DETALLE DE INSTALACION DE INTERRUPTOR


TERMOMANETICO INTERRUPTOR
TOMACORRIENTES A TIERRA BIPOLAR TERMOMANETICO
2x.... A TETRAPOLAR
4x.... A

TUBO PVC-SAP
EMPALME DE RESORTE
1/2
3/4
CABLE DE TIERRA 3/4
1/2 5/6
7/8
TERMINAL (color verde y/o verde
PVC-SAP con franja amarilla)
kw/h 4/3
2/1
2/1
4/3
6/5
8/7
F.P.

S(a) S2(a,b,c) 2x... A


4x... A
INTERRUPTOR SIMPLE INTERRUPTOR TRIPLE CABLE
(Color rojo)
P
TERMINAL
PVC-SAP
Tv.
CAJA DE CABLE
100x100x50mm (color negro)
INTERRUPTORES
TERMOMAGNESTICOS
S,2S,3S,4S,SC

S2(a,b) TV
T

T/PA
INTERRUPTOR DOBLE PLACA CIEGA CON APERTURA
TH
PARA SALIDA DE CABLE
PROPIETARIO:

TOMACORRIENTE DUPLEX
TOMA TELEFONICA