SAUDIARAMCO.

NOTES:

426-K-0312 A/B/C 426-K-0313 426-U-0107 426-D-0433 426-D-0434 426-D-0431 426-D-0430


1. R.O MEMBRANES ARE 3x50%.
RO MENBRANE CIP AGITATOR RO UNIT CARTRIDGE FILTERS FLUSHING/CIP TANK SODIUM HYDROXIDE DOSING TANK OXYGEN SCAVENGER DOSING TANK 2. OXYGEN SCAVENGER DOSING PACKAGE CONSIST OF
1x100% OXYGEN SCAVENGER DOSING TANK, 2x100%
QTY : 3 QTY : 1 QTY : 1 QTY : 1 QTY : 1 QTY : 1 OXYGEN SCAVENGER DOSING PUMPS AND 1x100% IN
PERMEATE FLOW : 104.4 cu.m/h TO 122.8 cu.m/h POWER REQUIRMENT : 0.75 kW TYPE : CARTRIDGE FILTER TYPE : ATMOSPHERIC TANK TYPE : VERTICAL CYLINDRICAL TYPE : VERTICAL CYLINDRICAL LINE MIXER.
STAGE : 1 MOC : AISI 316 CAP : 450 cu.m/h (1981 GPM) CAP : 25 cu.m CAP : 3.6 cu.m CAP : 3.6 cu.m

OF
3. SODIUM HYDROXIDE DOSING PACKAGE CONSIST OF 1x100%
RECOVERY : 34-40% DESIGN TEMP SIZE : 3m DIA. X 4.5 mH SIZE : 1.8m DIA x 1.9m TH SIZE : 1.8m DIA x 1.9m TH
SODIUM HYDROXIDE DOSING TANK, 2x100% SODIUM
DESIGN PRESSURE : 10.3 BAR (150 PSIG) DESIGN TEMP DESIGN TEMP DESIGN TEMP

CONSENT
MOC : FRP DESIGN PRESSURE : ATMOSPHERIC DESIGN PRESSURE : ATMOSPHERIC DESIGN PRESSURE : ATMOSPHERIC HYDROXIDE DOSING PUMPS AND 1x100% IN LINE MIXER.

MOC : FRP MOC : FRP MOC : FRP


DESIGN CODE : ASME RTP-1 DESIGN CODE : VTA DESIGN CODE : VTA

TTEN
WRI
CONTINUED ON
BA-002059.001
VEOLIA SCOPE VEOLIA BY CONTRACTOR

THE
426-U-0107

THOUT
WI NG
DRAWI
M

S
THI
FROM
M

NED
19

OBTAI
426-K-0313

426-D-0433 426-G-0321 A/B 426-D-0434

BE
PART,SHALL
(NOTE-1)
(NOTE-3) (NOTE-2) REFERENCE DRAWINGS
426-K-0312A OXYGEN
SODIUM DWG. CONTROL FOR J.O. 10-01635.0001 BD-002057
HYDROXIDE
M M SCAVENGER

N
RO FEED

I
DOSING TANK DOSING TANK R.O MASS BALANCE »¿BA-ˆ9
BA-002059.001 13 14

FULL,OR
FROM RO FEED PUMPS
426-G-0320A 426-G-0318 A/B 426-D-0430
426-D-0431 426-G-0319 A/B

15 21

N
I ON
REPRODUCTI
27 28

426-K-0312B

RO FEED RO PERMEATE

SAUDIARAMCO.NO
BA-002059.001 13 14 17 18 BA-002060.001

FROM RO FEED PUMPS TO RO PERMEATE

426-G-0320B STORAGE TANK

15

OF
PROPERTY
426-K-0312C

RO FEED
BA-002059.001 13 14 20

SOLE
FROM RO FEED PUMPS
426-G-0320C

THE
15

ARE
MINIMUM FLOW RECYCLE/
OFF SPEC PRODUCT

BA-002060.001 ISSUED FOR


CONSTRUCTION

N
HEREI
FROM MAIN HEADER

NNF

NED
RO REJECT

CONTAI
16 PA-844145.001

TO UWIP-3
REVISION VALIDATION
SEAWATER HEADER
CONTINUED ON THIS REVISION NO. 00 IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
BA-002059.001 REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

ON
10-01635-0001-001

NFORMATI
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) x REQUIRED (SAUDI ARAMCO)

ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE

MAJ ASH ABL AAM

426-G-0319 A/B 426-G-0318 A/B 426-G-0321 A/B 01/08/18 07/18/19 07/18/19 07/18/19

REV.NO. DATE REVISION DESCRIPTION

I
SODIUM HYDROXIDE DOSING PUMPS OXYGEN SCAVENGER DOSING PUMPS FLUSHING/CIP PUMPS 00 07/18/19 ISSUED FOR CONSTRUCTION

THE
JOB ORDER/EWO NO.
QTY QTY THIS REVISION IS NOT TO BE USED FOR
QTY : 2 NOS. (1 DUTY/1 STANDBY) : 2 NOS. (1 DUTY/1 STANDBY) : 2 NOS. (1 DUTY/1 STANDBY)
10-01635-0001 CONSTRUCTION UNTIL CERTIFIED AND DATED
: 0.01 cu.m/h (2.64 GPH) CAP : 0.01 cu.m/h (2.64 GPH) CAP : 450 cu.m/h (1981 GPM)
CAP
SAUDI ARABIAN OIL COMPANY

AND
: POSITIVE DISPLACEMENT TYPE : POSITIVE DISPLACEMENT TYPE : HORIZONTAL CENTRIFUGAL
TYPE
DIFFERENTIAL PRESSURE : 7 BAR (1?1.5 PSI) DIFFERENTIAL PRESSURE : 4.5 BARG (66.25 PSIG)
DIFFERENTIAL PRESSURE : 7 BAR (101.5 PSI) DRAWING TYPE

: 0.25 KW (0.34 HP) POWER REQUIREMENT : 0.25 KW (0.34 HP) POWER REQUIREMENT : 75 KW (100 HP) PROCESS FLOW DIAGRAM PFD
POWER REQUIREMENT

NG
: API 675 DESIGN CODE : API 675 DESIGN CODE : ASME B73.1
DESIGN CODE
REVERSE OSMOSIS UNIT

DRAWI
UTHMANIYAH WATER INJECTION PLANT #3

UTHMANIYAH SAUDI ARABIA

S
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

THI
426 A BA-002059 002 00
Saudi Aramco 2615 ENG. (05/05)