Penetrant Inspection
A Nondestructive testing (NDT) Procedure suitable for General
Liquid/Dye Penetrant Inspections. This is a sample LPT
procedure and may be required to be modified as per specific
requirements.
NDT Procedure No: RE-DOC-LPT-01 Rev ‘0’
ROYAL ENTERPRISES
Aerospace & General NDT ǀ Training & Certification ǀ Welding Inspection ǀ ASNT NDT Level III
Consulting ǀ Sales
ROYAL ENTERPRISES
An ISO 9001:2008 Certified Company
PROCEDURE FOR
LIQUID PENETRANT EXAMINATION
Procedure No. RE-LPT-Doc-01 Rev ‘0.
`
1. Scope
This Test method covers procedures for penetrant examination of butt and fillet weld with
the associated Heat Effected Zone (HAZ) on the parent metal and components. They are
non-destructive testing methods for detecting discontinuities that are open to the surface
such as cracks, porosity and lack of fusion by liquid penetrant testing conducted in
accordance with the requirements of the referenced Codes and Standards.
2. Purpose
The purpose of this procedure is to explain the method of applying the liquid penetration
non-destructive test.
3. References
4. Definitions
PT : Penetrant Examination
Trinity NDT® Procedure for Liquid Penetrant Page 2 of
5. Responsibilities Examination 6
The NDT Inspector shall be responsible for conducting and reporting the results of inspection
in accordance with project contract.
6. Personnel Qualifications
6.2 When the written practice is revised, the certification of NDE personnel remains valid
to the requirements of the previous revision until the expiry date of the personnel qualification
certificate; then, recertification to the requirements of the new revision is required.
7. Procedure
This procedure shall be demonstrated prior to use in accordance with the requirements of T-
150, ASME Code Sec. V. The procedure qualification record shall be attached to this
procedure.
7.1 Equipment:
a) Penetrant. b) Penetrant remover/cleaner. c) Developer. d) Lint free cloth. e) Light meter capable
of measuring visible light intensity in lux / foot candles (f.c.). The light meter shall meet the
calibration requirement of T-660 of ASME Code Section V
7.2 Materials:
7.2.1 Only materials of a recognized commercial quality shall be used as identified by the
manufacturer’s name i.e. Ardrox, Ely Chemicals or Magnaflux or as specified by the client.
7.2.2 Penetrant materials of the same family group shall be used, mix between family groups is
prohibited.
7.2.3 Certification of contaminant content shall be provided by manufacturers for all liquid
penetrant materials used on nickel base alloys, austenitic or duplex stainless steels, and
titanium. These certifications shall include the penetrant manufacturers' batch numbers and the
test results obtained in accordance with Mandatory Appendix II of Article 6, ASME Code Sec.
V. These records shall be maintained as required by the referencing Code Section.
Trinity NDT® Procedure for Liquid Penetrant Page 3 of
Examination 6
7.3 Surface Condition:
7.3.1 Generally satisfactory results may be obtained when the surface of the part is in the as-
welded, as- rolled, as-cast, or as forged condition. Surface preparation by grinding, machining,
or other methods may be necessary where surface irregularities could mask indications of
unacceptable discontinuities. Precautions shall be made with the mechanical cleaning not
to close the discontinuities open to the surface. Etching of the cleaned surfaces may be
necessary to open the discontinuities.
7.3.2 Prior to all liquid penetrant inspections, the surface to be examined and all adjacent areas within
at least 25mm (1”) shall be dry and free of dirt, grease, lint, scale, welding flux, weld spatter, oil and
other extraneous matters that could obscure surface openings or otherwise interfere with the
examination.
7.3.3 Typical cleaning agents that may be used are detergents, organic solvents, descaling
solutions and paint removers. Degreasing and ultrasonic cleaning methods may also be
used.
7.4 Method:
a)After the area has been cleaned, dried and the temperature of the surface and penetrant are
within the range of 40° F (5° C) to 125° F (52° C), the penetrant shall be sprayed directly
to the surface to be inspected by means of aerosol container, so that the entire area
under inspection is completely covered.
b) After application, excess penetrant shall be allowed to drain (care being taken to prevent
pools of penetrant forming on the test area) while allowing for minimum penetration
(dwell) time stated in accordance with (ASME V.Article24, SE165) unless otherwise
specified by the client in a more restrictive manner.
c) The length of time the penetrant must remain on the part to allow proper penetration
should be as recommended by the penetrant manufacturer (dwell time shall not exceed the
maximum recommended by the manufacturer).
a)After the specified dwell time has been elapsed, any penetrant remaining on the
surface shall be removed with a dry or slightly moistened cloth of solvent cleaner, taking
care to minimize removal of penetrant from possible discontinuity.
b) Flushing the surface with solvent cleaner, following the application of the penetrant and
prior to developing is prohibited.
Trinity NDT® Procedure for Liquid Penetrant Page 4 of
Examination 6
7.4.5 Drying after removal of excess penetrant:
a) The drying process shall be accomplished by normal evaporation. Drying time shall only be
that necessary to adequately dry the part.
a)Apply the non-aqueous wet developer directly to the area being inspected, by spraying from
the aerosol container.
e) Developing dwell time shall not be less than 10 min., The maximum permitted developing time
is 1 h for nonaqueous developers as stated in accordance with (ASME-V.Article24, SE-165)
unless otherwise specified by the client, in a more restrictive manner.
7.5 Examination:
7.5.1 Inspection shall be carried out after the applicable developer dwell time to allow for
bleed out of penetrant from discontinuities into the developer coating. It is good practice
to observe the bleed out while applying the developer as an aid in interpreting and
evaluating indications.
7.5.2 Visible penetrant indications can be inspected in natural or artificial white light. A minimum
intensity at the inspection surface of 100 foot candles (1000 Lux) is required.
7.5.3 The light source, technique used, and light level verification is required to be
demonstrated, one time, documented, and maintained on file.
7.6.1 All indications shall be evaluated in accordance with the referencing code or Specification.
7.6.2 Relevant indications are those that result from mechanical discontinuities:
a)Linear indications are those indications in which the length is more than three times the width.
b) Rounded indication or indications which are circular or elliptical with lengths less than three
times the width.
c) Any questionable or doubtful indications shall be re-tested to verify whether or not actual
defects are present.
Trinity NDT® Procedure for Liquid Penetrant Page 5 of
Examination 6
d) Localized surface imperfections may occur, such as machine marks, surface conditions, or
incomplete bond between base metal and cladding, may produce similar indications
which are not relevant to the detection of unacceptable discontinuities.
7.8.1 Upon completion of the test, in cases where residual penetrant or developer could
interfere with subsequent processing or with service requirements, a suitable technique, such as
a water rinse or solvent soak for cleaning may be employed.
Trinity NDT® Procedure for Liquid Penetrant Page 6 of
Examination 6
7.9 Documentation:
7.9.1 Non-rejectable indications shall be recorded as specified by the referencing Code Section.
7.9.2 Rejectable indications shall be recorded. As a minimum, the type of indications (linear or
rounded), location and extent (length or diameter or aligned) shall be recorded.
8. Records
Liquid Penetrant Examination shall be documented on Liquid Penetrant Examination Report form no.
TNE-PTR-03 Rev ‘0’
9. Attachments:
Liquid Penetrant Examination Report ……………………………………….. RE-PTR-01 Rev ‘0’