110mm (4") PVC SOIL PIPE

FROM SECOND FLOOR WITH PIPE EXTENSION


AND PLUG
110mm (4") PVC SOIL PIPE 3 A B
4" Ø CWL PIPE
FROM SECOND FLOOR

A B C A B C A B C
WITH PIPE EXTENSION 1 F
90mm (3") Ø PVC PIPE DOWNSPOUT AND PLUG WC LAV

1 DS 1 1 1 1 CWL CWL CWL


1
DS DS DS DIRTY KITCHEN DS DIRTY KITCHEN CWL CWL CWL

CWL
FCO DS GV
SOIL SOIL
SOIL SOIL SOIL SOIL SOIL CWL CWL CWL CWL CWL CWL HB

FD FD SOIL
WITH PIPE EXTENSION SINK
3
4" Ø CWL VERT.

CWL
SINK
SINK SEPTIC 110mm (4") PVC SOIL PIPE SINK

CWL
VAULT
AND PLUG PIPE TO 2ND FLR.
FROM SECOND FLOOR
(WATERLINE PLAN)

CWL
FD
DINING DINING

CWL
WC WC
FCO
CHANNEL DRAINAGE 6 ENLARGED TOILET AND BATH - 2ND FLOOR

IL
SO
WITH PIPE EXTENSION

CWL
POWDER ROOM POWDER ROOM PL 02 SCALE 1:50
LAV
AND PLUG LAV

CWL
2 2 2 2 2 2

SOIL
3
4" Ø CWL PIPE

CWL
3
4"
Ø CWL PIPE C

SOIL
FROM MAIN SUPPLY

CWL
110mm (4") Ø uPVC TO

SOIL
ROOF CARPORT NEAREST SEWER LINE CARPORT WITH PIPE EXTENSION 1

CWL
LINE (VERIFY SITE CONDITION) AND PLUG

CWL
3
4" Ø CWL VERT.
GV CWL CWL CWL PIPE FROM GRD.
F FLR.
3 3 3 3 3 CV 3 LAV WC
WATER METER
METER SHUT-OFF
4 4 4 GATE ENTRANCE
4 4 4
110mm (4") Ø uPVC TO FROM MAIN WATER SUPPLY

A B C A B C NEAREST DRAINAGE OUTLET A B C


(VERIFY SITE CONDITION)
(SEWER LAYOUT) (SEWER LAYOUT) (WATERLINE LAYOUT)
2 ROOF FLOOR PLAN 1 GROUND FLOOR PLAN 3 GROUND FLOOR PLAN (WATERLINE PLAN)
PL 02 SCALE 1:100 PL 02 SCALE 1:100 PL 02 SCALE 1:100
7 ENLARGED MASTER BATHROOM
ET
AUC PIP
SCALE 1:50
F W E EX PL 02
PRITH P TEN
EV LU SIO
EN G N
WC V T G TO
UR
LA
GL
E
63mm (2") Ø PVC FR
VENT PIPE THRU ROOF
110mm (4") PVC GUOM

2" VENT PIPE


TTE
A B SOIL PIPE TO R

2" VENT PIPE


THRU ROOF
GROUND FLOOR
N
N SIO
T T LE
E O FC
EX UG URG 3
4" O
1 E L
PIPITH PNT G
Ø
CW FD FR
LAV PIP WC LA
V GUOM
SOIL

WC N W E LP W E EX
SO
IL
TTE
EV IPE
SIO PR PRITH P TEN R
SOIL
SOIL

EN O E EV LU SIO
XT T RGL

2" VENT PIPE THRU ROOF


CO EN G N SO
SOIL SOIL SOIL DS DS
I P E EPLUG U SIN T G TO
IL
11
P ITH NT G V UR 0m
FD W EVE
K LA G m

90mm (3") uPVC PIPE DOWNSPOUT


SO
R L LE (4"IL
P C W
CW
T )P
WC CE

2" VENT PIPE THRU ROOF


L
VC
U PIPE
WC FA SOSOIL

90mm (3") uPVC PIPE DOWNSPOUT


110 (4") PVC VERTICAL SOIL PIPE
3
110mm (4") PVC SOIL PIPE LA C WL 4"
Ø NT IL P FR
(SEWER PLAN) V CW
CW VE 2"
L
LP 2" IPE VE
N GUOM
4 ENLARGED TOILET AND BATH - 2ND FLOOR IPE TP TTE

3 " Ø CWL PIPE VERTICAL TO


CW PIP IPE R
PL 02 SCALE 1:50
L
WI E EX
PRTH P TEN

90mm (3") uPVC PIPE DOWNSPOUT


CW EV LU SIO SIN
L EN G N K FC
K T G TO O V
SING HO UR V LA
C V SE G LA FD 11
BIB CW LE

SECOND FLOOR
SO
IL 0m
L IL m CO WC
63mm (2") Ø PVC WC
SO
(4"
VENT PIPE THRU ROOF S)O P
CW IL V FD
1 L
O
C
SO
FC

110mm (4") PVC VERTICAL SOIL PIPE


IL P
CW
L
SO
IL IPE

4
DS SO K
IL
SIN
WL
FD C
LAV LY
SO
IL
WC PPL
SU CW
110mm (4") PVC TER SO

WA
IL
CO SOIL SOIL SOIL PIPE TO IN CW L
GROUND FLOOR MA
OM SE
PT
FRCWL IC
P IPE VA
110mm (4") PVC WL U LT
SOIL PIPE C CW
L


GE
3 4
A
(SEWER PLAN) CWL
R AIN
5 ENLARGED MASTER BATHROOM FR 1
(V N10m T D)
OM ME WA ER EA m
IFY RE (4"
E
AR ON
S
PL 02 SCALE 1:50 MA TER TE IV SIT ST ) Ø SO
IL NE DITI
TO N
SH R M CV
E C SE uP
IN (WATERLINE PLAN) ONWER VC VC CO (SEWER PLAN)
P
u IT E
WA UT ETE 8 ISOMETRIC LAYOUT DIT LINSOITL O
IO E ) Ø IFY S 9 ISOMETRIC LAYOUT
TER -O R N) 4 "
( VE R
FF PL 02 SCALE 1:50 IL
m (
0mTLET PL 02 SCALE 1:50
SU SO
1
1 OU
PP
LY

CERTIFIED BY: PRC NO.: PROJECT TITLE: APPROVAL: SHEET CONTENT: REVISION: SHEET NUMBER
VALIDITY:
PTR NO.:
ISSUED AT: TWO (2) STOREY + ROOF DECK RESIDENTIAL BUILDING SANITARY AND PLUMBING LAYOUTS P2
ISSUED ON: MR./MRS. ABDUL HAMID R. BATUGAN SANITARY AND PLUMBING ISOMETRIC LAYOUTS
TIN NO.: CLIENT / OWNER
12 14
ISSUED AT: LOCATION: VILLA ANGELA SUBD. BRGY. BALULANG, CAGAYAN DE ORO NO DESCRIPTION DATE