Dead Load calculation :


Self weight of Checker Plate 54 Kg/M2

Self weight of Cage Ladder 75 Kg/M


1. Live Load calculation:

Live Load at Checker Plate floor 75 Kg/M2

1. Load calculation of :

WIND LOAD (WL)


Basic wind speed (Vb) = 50 m/s Schudule of Factor K2
Design wind speed (Vz) = Vbxk1xk2xk3Xk4 Ht(m) K2
where, Upto -10 1
k1 = probability factor (risk coefficient) 10 to 15 1.05
= 1 15 to 20 1.07
k2 = Terrain Category 2 Height K2 20 to 30 1.12
= 1.10 20 1.07 30 to 50 1.17
30 1.12 50 to 100 1.24
25 1.10
k3 = Topography factor
= 1
k4 = Cyclonic Factor
= 1

Vz = 54.75 m/s
Design wind pressure (pz) = 0.6xVz²
pz = 1.80 KN/m²
Design Wind Pressure (Pd) = Pz X Kd X Ka X Kc
Wind Directionality Factor (Kd) = 1 Clause 7.2.1 of IS 875 - Part 3
Area Averaging Factor (Ka) = 1 Clause 7.2.2 of IS 875 - Part 3
Combination Factor (Kc) = 0.9 Clause 7.3.3.13 of IS 875 - Part 3
Kd X Ka X Kc = 0.9 > 0.7 OK
Design Wind Pressure (Pd) = 1.62 KN/m²

Ht Vz (m/s) Pz(Kn/m²) Pd(Kn/m²)


m.
0-10 50.00 1.50 1.35
10_15 52.50 1.65 1.49
15_20 53.50 1.72 1.55
20_30 56.00 1.88 1.69
30_50 58.50 2.05 1.85