AIR™ Recon DL

Level up your image quality

AIR™ Recon DL 1
T O M O R R OW T OD AY

AIR™ Recon DL
SNR vs. Spatial Resolution

Conventional Conventional AIR™ Recon DL


Low Resolution, High SNR High Resolution, Low SNR High Resolution, High SNR
0.6 x 0.6 x 3.0 mm 0.4 x 0.4 x 3.0 mm 0.4 x 0.4 x 3.0 mm

Increasing the spatial resolution will reduce SNR. This negatively impacts quality and also reduces productivity by increasing acquisition time.
AIR™ Recon DL allows making improvement in spatial resolution while improving signal.
AIR™ Recon DL 2
T O M O R R OW T OD AY

AIR™ Recon DL
SNR vs. Spatial Resolution

Conventional Conventional AIR™ Recon DL


Low Resolution, High SNR High Resolution, Low SNR High Resolution, High SNR
0.6 x 0.6 x 3.0 mm 0.4 x 0.4 x 3.0 mm 0.4 x 0.4 x 3.0 mm

Increasing the spatial resolution will reduce SNR. This negatively impacts quality and also reduces productivity by increasing acquisition time.
AIR™ Recon DL allows making improvement in spatial resolution while improving signal.
AIR™ Recon DL 3
T O M O R R OW T OD AY

AIR™ Recon DL
SNR vs. Short Acquisition Times

Conventional Conventional AIR™ Recon DL


Acceptable SNR, Long Scan Time Unacceptable SNR, Short Scan Time Acceptable SNR, Short Scan Time
2 NEX 1 NEX 1 NEX
3:24 min 1:56 min 1:56 min

One solution to increase productivity is to reduce the number of signal averages (NEX). However, this increases the noise in the image and can result in unacceptable quality.
AIR™ Recon DL allows maintaining desired quality and improving throughput simultaneously.
AIR™ Recon DL 4
T O M O R R OW T OD AY

AIR™ Recon DL
SNR vs. Spatial Resolution

Conventional Conventional Conventional Conventional


0.7 x 0.7 x 3.0 mm 0.6 x 0.6 x 3.0 mm 0.5 x 0.5 x 3.0 mm 0.4 x 0.4 x 3.0 mm

Increasing the spatial resolution will


reduce SNR. This negatively impacts
quality and also reduces productivity
by increasing scan time. AIR™ Recon
DL allows improvements in spatial
resolution while improving signal.

Conventional Conventional Conventional


0.37 x 0.37 x 3.0 mm 0.33 x 0.33 x 3.0 mm 0.28 x 0.28 x 3.0 mm

AIR™ Recon DL 5
T O M O R R OW T OD AY

AIR™ Recon DL
SNR vs. Spatial Resolution

Conventional Conventional Conventional Conventional


0.7 x 0.7 x 3.0 mm 0.6 x 0.6 x 3.0 mm 0.5 x 0.5 x 3.0 mm 0.4 x 0.4 x 3.0 mm

Increasing the spatial resolution will


reduce SNR. This negatively impacts
quality and also reduces productivity
by increasing scan time. AIR™ Recon
DL allows improvements in spatial
resolution while improving signal.

Conventional Conventional Conventional


0.37 x 0.37 x 3.0 mm 0.33 x 0.33 x 3.0 mm 0.28 x 0.28 x 3.0 mm

AIR™ Recon DL 6
T O M O R R OW T OD AY

AIR™ Recon DL
SNR vs. Spatial Resolution

AIR™ Recon DL AIR™ Recon DL AIR™ Recon DL AIR™ Recon DL


0.7 x 0.7 x 3.0 mm 0.6 x 0.6 x 3.0 mm 0.5 x 0.5 x 3.0 mm 0.4 x 0.4 x 3.0 mm

Increasing the spatial resolution will


reduce SNR. This negatively impacts
quality and also reduces productivity
by increasing scan time. AIR™ Recon
DL allows improvements in spatial
resolution while improving signal.

AIR™ Recon DL AIR™ Recon DL AIR™ Recon DL


0.37 x 0.37 x 3.0 mm 0.33 x 0.33 x 3.0 mm 0.28 x 0.28 x 3.0 mm

AIR™ Recon DL 7
T O M O R R OW T OD AY

AIR™ Recon DL
SNR vs. Spatial Resolution

AIR™ Recon DL AIR™ Recon DL AIR™ Recon DL AIR™ Recon DL


0.7 x 0.7 x 3.0 mm 0.6 x 0.6 x 3.0 mm 0.5 x 0.5 x 3.0 mm 0.4 x 0.4 x 3.0 mm

Increasing the spatial resolution will


reduce SNR. This negatively impacts
quality and also reduces productivity
by increasing scan time. AIR™ Recon
DL allows improvements in spatial
resolution while improving signal.

AIR™ Recon DL AIR™ Recon DL AIR™ Recon DL


0.37 x 0.37 x 3.0 mm 0.33 x 0.33 x 3.0 mm 0.28 x 0.28 x 3.0 mm

AIR™ Recon DL 8
T O M O R R OW T OD AY

AIR™ Recon DL
SNR, Signal Averages (NEX) and Acquisition Time

Conventional Conventional Conventional Conventional


0.3 x 0.3 x 3.0 mm 0.3 x 0.3 x 3.0 mm 0.3 x 0.3 x 3.0 mm 0.3 x 0.3 x 3.0 mm
2 NEX 4 NEX 8 NEX 16 NEX
2:34 min 5:02 min 10:00 min 19:54 min

One solution to increase productivity is to reduce the number of signal averages (NEX). However, this increases the noise in the image and can result in unacceptable quality.
AIR™ Recon DL allows maintaining desired quality and improving throughput simultaneously.
AIR™ Recon DL 9
T O M O R R OW T OD AY

AIR™ Recon DL
SNR, Signal Averages (NEX) and Acquisition Time

AIR™ Recon DL AIR™ Recon DL AIR™ Recon DL Conventional


0.3 x 0.3 x 3.0 mm 0.3 x 0.3 x 3.0 mm 0.3 x 0.3 x 3.0 mm 0.3 x 0.3 x 3.0 mm
2 NEX 4 NEX 8 NEX 16 NEX
2:34 min 5:02 min 10:00 min 19:54 min

One solution to increase productivity is to reduce the number of signal averages (NEX). However, this increases the noise in the image and can result in unacceptable quality.
AIR™ Recon DL allows maintaining desired quality and improving throughput simultaneously.
AIR™ Recon DL 10
T O M O R R OW T OD AY

AIR™ Recon DL
SNR, Signal Averages (NEX) and Acquisition Time

AIR™ Recon DL Conventional


0.3 x 0.3 x 3.0 mm 0.3 x 0.3 x 3.0 mm
2 NEX 16 NEX
2:34 min 19:54 min

One solution to increase productivity is to reduce the number of signal averages (NEX). However, this increases the noise in the image and can result in unacceptable quality.
AIR™ Recon DL allows maintaining desired quality and improving throughput simultaneously.
AIR™ Recon DL 11
T O M O R R OW T OD AY

Diffusion Weighted Imaging with AIR™ Recon DL

b500
b50 b500 b50
b850

SIGNA™ Pioneer
Prostate
with AIR™ Recon DL
Axial FOCUS DWI
2 x 3 x 4 mm b850 SIGNA™ Artist ADC
3:58 min Kidneys
with AIR™ Recon DL
Coronal FOCUS DWI
b1500 ADC 2.6 x 3.3 x 3 mm
MAGiC DWI 2:10 min

SIGNA™ Works AIR™ IQ Edition Images Courtesy of Houston Medical Imaging – Houston TX USA
AIR™ Recon DL
SIGNA™ Artist SIGNA™ 3.0T MR Scanners

NeuroWorks NeuroWorks

OrthoWorks OrthoWorks

CVWorks CVWorks

BodyWorks BodyWorks

HyperSpeed Protocols HyperSpeed Protocols

AIR™ Recon DL 13
SIGNA™ Artist
NeuroWorks
AIR™ Recon DL

AIR™ Recon DL | SIGNA™ Artist 14


T O M O R R OW T OD AY

NeuroWorks
Intelligent Ringing Suppression – AIR x™ Prescribed

Axial T2* GRE Conventional Coronal T2 FSE AIR™ Recon DL


Conventional 0.9 x 1.5 x 5 mm AIR™ Recon DL 0.6 x 0.6 x 3 mm
:58 sec 1:09 min
In addition to boosting SNR and reducing noise, AIR™ Recon DL improves image quality further by reducing subtle artifacts com monly seen between adjacent high contrast
structures. With removing problematic artifacts like Gibbs ringing (truncations), it allows for increasing accuracy when they appear in anatomical areas near lesions.

AIR™ Recon DL | SIGNA™ Artist 15


T O M O R R OW T OD AY

NeuroWorks
Routine Brain
AIR x™ Prescribed
Exam Time = 5 minutes

Sagittal T1 FLAIR Axial T2 FSE Axial T2 FLAIR FatSat


1 x 1.3 x 5 mm 0.9 x 1.1 x 5.0 mm 0.8 x 1.5 x 5 mm
:49 sec :34 sec 1:17 min

Axial DWI b1000


Axial T2* GRE with HyperBand
0.9 x 1.5 x 5 mm 2 x 2 x 5 mm
:58 sec :24 sec
(acquired with conventional reconstruction)
AIR™ Recon DL | SIGNA™ Artist 16
T O M O R R OW T OD AY

NeuroWorks
Routine Brain – AIR x™ Prescribed

Conventional AIR™ Recon DL Conventional AIR™ Recon DL


Axial T2 FLAIR Sagittal PD FSE
0.9 x 1 x 4 mm 0.8 x 0.9 x 4 mm
3:24 min 1:19 min

AIR™ Recon DL | SIGNA™ Artist 17


T O M O R R OW T OD AY

NeuroWorks
Pituitary and Orbits- AIR x™ Prescribed

Conventional

Conventional AIR™ Recon DL


Coronal T1 FSE AIR™ Recon DL
0.6 x 0.8 x 3 mm
:47 sec Axial T2 FatSat
0.5 x 0.7 x 3 mm
1:25 min
AIR™ Recon DL | SIGNA™ Artist 18
T O M O R R OW T OD AY

NeuroWorks
Temporal Lobes - AIR x™ Prescribed

Conventional Coronal T2 FSE AIR™ Recon DL


0.6 x 0.6 x 3 mm
1:09 min
AIR™ Recon DL | SIGNA™ Artist 19
T O M O R R OW T OD AY

NeuroWorks
AIR x™ Prescribed

Axial T2 FLAIR
Conventional
0.9 x 1 x 4 mm
4:12 min

Scan time reduction Conventional


19% and 25%
improvement in
spatial resolution

Axial T2 FLAIR
AIR™ Recon DL
0.8 x 0.9 x 4 mm
3:24 min

AIR™ Recon DL
AIR™ Recon DL
Increasing parallel imaging factors and reducing NEX (signal averages) can lead to increased noise in MR images.
AIR™ Recon DL can lead to flexibility in protocol parameter selection and improve overall image quality by increasing the apparent SNR.
AIR™ Recon DL | SIGNA™ Artist 20
T O M O R R OW T OD AY

NeuroWorks
Cervical Spine

Conventional

0.7 x 1.0 x 4.0 mm


2:12 min
Conventional AIR™ Recon DL Conventional AIR™ Recon DL AIR™ Recon DL
Sagittal T2 FSE Sagittal T1 FSE Axial T2 FSE
0.4 x 0.7 x 3 mm 0.6 x 0.7 x 3 mm 0.5 x 0.5 x 3 mm
2:32 min 2:06 min 2:36 min
AIR™ Recon DL | SIGNA™ Artist 21
T O M O R R OW T OD AY

NeuroWorks
AIR™ Recon DL - SNR and CNR Improvements

Sagittal T2 STIR
0.5 x 0.8 x 3 mm
2:45 min

AIR™ Recon DL | SIGNA™ Artist 22


T O M O R R OW T OD AY

NeuroWorks
AIR™ Recon DL - SNR and CNR Improvements

Conventional AIR™ Recon DL

Sagittal T2 STIR
0.5 x 0.8 x 3 mm
2:45 min

AIR™ Recon DL | SIGNA™ Artist 23


T O M O R R OW T OD AY

NeuroWorks
Cervical Spine Brain stem

Conventional AIR™ Recon DL


Sagittal T2 FSE Sagittal FOCUS DWI b600 Sagittal FOCUS DWI ADC map
AIR™ Recon DL AIR™ Recon DL AIR™ Recon DL Sagital FOCUS DWI b800
0.7x 0.8x 3 mm 1.8 x 1.4 x 3 mm 1.8 x 1.4 x 3 mm 1.8 x 1.8 x 3 mm
1:31min 2:44 min 2:44 min 2:44 min

AIR™ Recon DL | SIGNA™ Artist 24


OrthoWorks
AIR™ Recon DL

AIR™ Recon DL | SIGNA™ Artist 25


T O M O R R OW T OD AY

OrthoWorks
Shoulder

Conventional AIR™ Recon DL Conventional AIR™ Recon DL


Coronal PD FatSat Sagittal PD FSE
0.4 x 0.6 x 3 mm 0.4 x 0.6 x 3 mm
3:42 min 2:26 min

AIR™ Recon DL | SIGNA™ Artist 26


T O M O R R OW T OD AY

OrthoWorks
Upper Extremities

Conventional

Coronal PD FatSat
0.4 x 0.5 x 3 mm
2:34 min
Small GEM Flex Coil
Conventional AIR™ Recon DL AIR™ Recon DL
Axial PD FatSat
0.3 x 0.3 x 2 mm
1:48 min
16ch TR Hand Wrist Coil

AIR™ Recon DL | SIGNA™ Artist 27


T O M O R R OW T OD AY

OrthoWorks
Hip - AIR™ Anterior Array

Conventional AIR™ Recon DL


Conventional AIR™ Recon DL
0.4 x 0.6 x 3 mm 0.4 x 0.6 x 2.5 mm
3:16 min 2:14 min

AIR™ Recon DL | SIGNA™ Artist 28


T O M O R R OW T OD AY

OrthoWorks
Shoulder - AIR™ Anterior Array

Conventional Axial PD FatSat AIR™ Recon DL


0.5 x 0.7 x 3 mm
2:18 min

Conventional Sagittal T2 FatSat AIR™ Recon DL


0.5 x 0.6 x 3 mm
2:12 min

Conventional Coronal PD FatSat AIR™ Recon DL


0.5 x 0.6 x 3.5 mm
2:35 min
AIR™ Recon DL | SIGNA™ Artist 29
T O M O R R OW T OD AY

OrthoWorks
Knee - AIR™ Anterior Array

Conventional AIR™ Recon DL Conventional AIR™ Recon DL


Axial T2 FatSat Sagittal PD FSE
0.4 x 0.6 x 3 mm 0.3 x 0.6 x 3 mm
2:08 min 2:52 min

AIR™ Recon DL | SIGNA™ Artist 30


CVWorks
AIR™ Recon DL

AIR™ Recon DL | SIGNA™ Artist 31


T O M O R R OW T OD AY

CVWorks
Cardiac - AIR™ Anterior Array

Conventional AIR™ Recon DL Conventional AIR™ Recon DL

Double Inversion Recovery Triple Inversion Recovery


1.4 x 1.4 x 8 mm 1.4 x 1.4 x 8 mm
:25 sec :27 sec

AIR™ Recon DL | SIGNA™ Artist 32


BodyWorks
AIR™ Recon DL

AIR™ Recon DL | SIGNA™ Artist 33


T O M O R R OW T OD AY

BodyWorks
Abdomen - AIR™ Anterior Array

Axial T2 SSFSE with ASPIR Axial T2 SSFSE


1 x 1.3 x 5 mm 1 x 1.4 x 5 mm Coronal T2 SSFSE
:17 sec :16 sec 1.4 x 1.6 x 3 mm
:14 sec

Coronal SSFSE FatSat


AIR™ Recon DL
1.6 x 1.8 x 1.6 mm
1:13 min

Axial Dual Echo Conventional AIR™ Recon DL


Conventional AIR™ Recon DL
0.8 x 1.2 x 4 mm
:22 sec
AIR™ Recon DL | SIGNA™ Artist 34
T O M O R R OW T OD AY

BodyWorks
Breast

Conventional

Conventional Sagittal T2 FatSat AIR™ Recon DL


0.6 x 0.8 x 5 mm AIR™ Recon DL
3:23 min Axial T2 FatSat
0.8 x 0.9 x 4 mm
3:01 min

AIR™ Recon DL | SIGNA™ Artist 35


T O M O R R OW T OD AY

BodyWorks
PI-RADS Compliant Prostate - AIR™ Anterior Array
Acquisition Resolution of 0.4 x 0.7 x 3 mm

Axial T2 FSE Sagittal T2 FSE Coronal T2 FSE


0.4 x 0.7 x 3 mm 0.4 x 0.7 x 3 mm 0.4 x 0.7 x 3 mm
4:15 min 3:53 min 5:28 min

AIR™ Recon DL | SIGNA™ Artist 36


T O M O R R OW T OD AY

BodyWorks
Prostate - AIR™ Anterior Array

Axial T2 FSE Sagittal T2 FSE Coronal T2 FSE


0.5x 0.8 x 3 mm 0.5 x 0.8 x 3 mm 0.7 x 1 x 4 mm
2:37 min 2:42 min 2:03 min

AIR™ Recon DL | SIGNA™ Artist 37


T O M O R R OW T OD AY

BodyWorks
Prostate - AIR™ Anterior Array

Axial T2 FSE Axial FOCUS DWI b800 Axial FOCUS MAGiC DWI b2000 Axial FOCUS DWI ADC map
0.4x 0.7x 3 mm AIR™ Recon DL AIR™ Recon DL AIR™ Recon DL
2:41 min 2.0 x 2.0 x 3 mm 2.0 x 2.0 x 3 mm 2.0 x 2.0 x 3 mm
3:41 min 3:41 min 3:41 min

AIR™ Recon DL | SIGNA™ Artist 38


HyperSpeed Protocols
Reduce exam times to under 5
minutes without sacrificing
resolution or signal

AIR™ Recon DL | SIGNA™ Artist 39


T O M O R R OW T OD AY

NeuroWorks with HyperSpeed


Enabled with AIR™ Recon DL
Total Exam Time 3:28 seconds

Sagittal T1 FLAIR Axial T2 FSE Axial T2 FLAIR


0.8 x 1.1 x 5 mm 0.7 x 1 x 5 mm 0.3 x 0.6 x 3 mm
:44 sec :40 sec 1:15 sec

Axial T2* GRE Axial DWI with HyperBand


0.9 x 1.5 x 5 mm 2.4 x 2.4 x 5 mm
:36 sec :13 sec

AIR™ Recon DL | SIGNA™ Artist 40


T O M O R R OW T OD AY

NeuroWorks with HyperSpeed


Enabled with AIR™ Recon DL
Total Exam Time 4:16 min

Axial T2 FSE
0.7 x 0.9 x 4 mm
:54 sec

Sagittal T2 FSE Sagittal T1 FSE Sagittal STIR FSE


0.7 x 1 x 3 mm 0.8 x 1 x 3 mm 0.8 x 1.1 x 3 mm
:56 sec 1:17 min 1:09 min
AIR™ Recon DL | SIGNA™ Artist 41
T O M O R R OW T OD AY

NeuroWorks with HyperSpeed


Enabled with AIR™ Recon DL
Total Exam Time 4:19 min

Sagittal T2 FSE Sagittal T1 FSE Sagittal T2 STIR Axial T2 FSE


0.7 x 0.9 x 3.5 mm 0.8 x 1.1 x 3.5 mm 0.8 x 1.3 x 3.5 0.7 x 1 x 4 mm
:45 sec 1:18 min 1:36 min :40 sec

AIR™ Recon DL | SIGNA™ Artist 42


T O M O R R OW T OD AY

OrthoWorks with HyperSpeed


Enabled with AIR™ Recon DL
Total Exam Time
4:46 min

Sagittal T2 FatSat Coronal PD FatSat Coronal T1 FSE


0.3 x 0.8 x 3 mm 0.4 x 0.6 x 3 mm 0.4 x 0.6 x 3 mm
1:12 min :50 sec 0:55 sec

Sagittal PD FSE Axial PD FatSat


0.4 x 0.7 x 3 mm 0.5 x 0.7 x 3.5 mm
:50 sec :59 sec

AIR™ Recon DL | SIGNA™ Artist 43


NeuroWorks
AIR™ Recon DL

AIR™ Recon DL | 3.0T 45


T O M O R R OW T OD AY

NeuroWorks
AIR™ Recon DL – Intelligent Ringing Suppression

Conventional AIR™ Recon DL Conventional AIR™ Recon DL


0.7 x 0.8 x 4.0 mm 0.9 x 1.0 x 3.5 mm
2:07 min 1:28 min

In addition to boosting SNR and reducing noise, AIR™ Recon DL improves image quality further by reducing subtle artifacts com monly seen between adjacent high contrast
structures. With removing problematic artifacts like Gibbs ringing (truncations), it allows for increasing accuracy when they appear in anatomical areas near lesions.

AIR™ Recon DL | SIGNA™ Architect 46


T O M O R R OW T OD AY

NeuroWorks
AIR™ Recon DL – Short Acquisition Times

Conventional AIR™ Recon DL


0.9 x 1.2 x 4.0 mm 0.7 x 1.0 x 4.0 mm
2:42 min 2:12 min

AIR™ Recon DL image demonstrates 18% improvement in scan time and 35% improvement in resolution.

AIR™ Recon DL | SIGNA™ Architect Imaging Protocol Courtesy of DASA – Sao Paulo, Brazil 47
T O M O R R OW T OD AY

NeuroWorks
AIR™ Recon DL – Tissue Contrast

Increased sharpness and a


reduction in noise could
allow for contrast
improvements.

In this case, smaller


structures may become
more apparent and easier
to visualize.

AIR™ Recon DL Conventional AIR™ Recon DL


0.9 x 1.0 x 3.5 mm
1:28 min.

Conventional AIR™ Recon DL

AIR™ Recon DL | SIGNA™ Premier 48


T O M O R R OW T OD AY

NeuroWorks
AIR™ Recon DL – Tissue Contrast
Conventional

Increased sharpness and a


reduction in noise could
allow for contrast
improvements.

In this case, smaller


structures may become
more apparent and easier
to visualize.

AIR™ Recon DL AIR™ Recon DL


0.9 x 1.0 x 3.5 mm
1:28 min.

Conventional AIR™ Recon DL

AIR™ Recon DL | SIGNA™ Premier 49


T O M O R R OW T OD AY

NeuroWorks
AIR™ Recon DL - DWI Enhancements

Conventional Conventional

ssEPI DWI FOCUS DWI


b1000 b1000
2 x 2 x 2 mm 1.2 x 4 x 3.5 mm
68 seconds 62 seconds

SIGNA™ Architect AIR™ IQ Edition 50


*Not yet CE marked. Not available for sale in all regions.
T O M O R R OW T OD AY

NeuroWorks
AIR™ Recon DL - SNR and CNR Improvements

One solution to increase


productivity is to reduce the
number of signal averages
(NEX). However, this
increases the overall noise
in the image and can result
in unacceptable quality.
AIR™ Recon DL allows
Conventional AIR™ Recon DL
maintaining desired quality
0.8 x 0.9 x 2.5 mm 0.8 x 0.9 x 2.5 mm
and improving throughput 1 NEX 1 NEX
simultaneously.

AIR™ Recon DL | SIGNA™ Premier 51


T O M O R R OW T OD AY

NeuroWorks
AIR™ Recon DL - SNR and CNR Improvements

One solution to increase


productivity is to reduce the
number of signal averages
(NEX). However, this
increases the overall noise
in the image and can result
in unacceptable quality.
AIR™ Recon DL allows
Conventional AIR™ Recon DL
maintaining desired quality
0.8 x 0.9 x 2.5 mm 0.8 x 0.9 x 2.5 mm
and improving throughput 1 NEX 1 NEX
simultaneously.

AIR™ Recon DL | SIGNA™ Premier 52


T O M O R R OW T OD AY

NeuroWorks
AIR™ Recon DL – Short Acquisition Times
T2 FLAIR FatSat DWI*
T1 FLAIR
0.9 x 1.2 x 5.0 mm 1.9 x 1.7 x 5.0 mm
1.9 x 1.7 x 5.0 mm
1:21 min 17 sec
36 sec

Total Scan Time


3:10 min
T2* GRE
T2 FSE 0.8 x 1.1 x 5.0 mm
0.8 x 1.1 x 5.0 mm 27 sec
24 sec

AIR™ Recon DL | SIGNA™ * Conventional 53


T O M O R R OW T OD AY

NeuroWorks
AIR™ Recon DL

Cervical Spine Thoracic Spine Lumbar Spine


0.4 x 0.4 x 3.0 mm 0.7 x 0.9 x 3.0 mm 0.7 x 0.9 x 3.0 mm

AIR™ Recon DL | SIGNA™ Premier 54


T O M O R R OW T OD AY

NeuroWorks
AIR™ Recon DL – Soft Tissue Neck Imaging

Conventional AIR™ Recon DL

0.7 x 0.9 x 4.0 mm 1 .0 x 1.0 x 3.0 mm 0.6 x 0.9 x 4.0 mm


35 slices 80 slices 30 slices
1:14 min 3:23 min 2:48 min

AIR™ Recon DL | SIGNA™ Architect 55


OrthoWorks
AIR™ Recon DL

AIR™ Recon DL | 3.0T 56


T O M O R R OW T OD AY

OrthoWorks
AIR™ Recon DL – Short Acquisition Times and SNR Improvement

The current solution to limit


noise is to reduce spatial
resolution (quality impact) or
increase signal averages (NEX)
which increases scan time and
can reduce productivity. AIR™
Recon DL allows maintaining
desired quality, improving signal
and reducing scan times while
reducing signal averages (NEX).

Conventional 66% reduction in AIR™ Recon DL


0.2 x 0.2 x 3.0 mm scan time 0.2 x 0.2 x 3.0 mm
3 NEX - 7:10 min 1 NEX - 2:26 min

AIR™ Recon DL | SIGNA™ Premier 57


T O M O R R OW T OD AY

OrthoWorks
AIR™ Recon DL - Intelligent Ringing Suppression

Conventional 0.4 x 0.6 x 3.5 mm AIR™ Recon DL


2:07 min

In addition to boosting SNR and reducing noise, AIR™ Recon DL improves image quality further by reducing subtle artifacts com monly seen between adjacent high contrast
structures. With removing problematic artifacts like Gibbs ringing (truncations), it allows for increasing accuracy when they appear in anatomical areas near lesions.

AIR™ Recon DL | SIGNA™ Architect 58


T O M O R R OW T OD AY

OrthoWorks
AIR™ Recon DL – Short Acquisition Times

AIR™ Recon DL AIR™ Recon DL AIR™ Recon DL


0.3 x 0.4 x 3.0 mm 0.3 x 0.5 x 3.0 mm 0.3 x 0.5 x 3.0 mm
2:28 min 2:11 min 1:50 min

AIR™ Recon DL | SIGNA™ Premier 59


T O M O R R OW T OD AY

OrthoWorks
AIR™ Recon DL – SNR and Acquisition Times

AIR™ Recon DL demonstrating 26%


improvement in scan time and 50%
improvement in resolution.

Conventional AIR™ Recon DL


0.4 x 0.6 x 3.0 mm 0.3 x 0.5 x 3.0 mm
2:58 min 2:11 min

AIR™ Recon DL | SIGNA™ Premier 60


T O M O R R OW T OD AY

OrthoWorks
AIR™ Recon DL – Short Acquisition Times

Total Scan time


6:53 min

AIR™ Recon DL | SIGNA™ Premier 61


T O M O R R OW T OD AY

Orthoworks
High spatial resolution

Coronal T1 Coronal T2 FatSat


0.3 x 0.3 x 2 mm 0.4 x 0.4 x 2 mm
1:47 min 1:58 min
Axial T2 FatSat Axial T1
0.3 x 0.3 x 2 mm, 1:49 min 0.3 x 0.3 x 2 mm, 2:39 min
AIR™ Recon DL | SIGNA™ Architect Image Courtesy of American Hospital of Paris - France
T O M O R R OW T OD AY

Same acquisition with and


without AIR™ Recon DL,
demonstrating an
improvement in image
sharpness.

63
T O M O R R OW T OD AY

OrthoWorks
AIR™ Recon DL – Sharpness and SNR Improvement

Same acquisition with and


without AIR™ Recon DL,
demonstrating an
improvement in image
sharpness.

Conventional
0.2 x 0.2 x 1.6 mm

AIR™ Recon DL
0.2 x 0.2 x 1.6 mm

AIR™ Recon DL | SIGNA™ Premier 64


T O M O R R OW T OD AY

OrthoWorks
AIR™ Recon DL – Sharpness and SNR Improvement

Conventional AIR™ Recon DL


0.2 x 0.2 x 1.6 mm 0.2 x 0.2 x 1.6 mm

Conventional AIR™ Recon DL


0.3 x 0.3 x 1.0 mm
Same acquisition with and without AIR™ Recon DL, demonstrating an improvement in image sharpness.

AIR™ Recon DL | SIGNA™ Pioneer 65


T O M O R R OW T OD AY

OrthoWorks
AIR™ Recon DL – Sharpness and SNR Improvement

Conventional AIR™ Recon DL Conventional AIR™ Recon DL


0.2 x 0.4 x 3.0 mm 0.3 x 0.3 x 2.5 mm
1:18 min 2:08 min

AIR™ Recon DL | SIGNA™ Premier 66


T O M O R R OW T OD AY

OrthoWorks
AIR™ Recon DL – Short Acquisition Times

Axial T2 FatSat Sagittal PD FSE Coronal PD FSE


0.4 x 0.6 x 3.5 mm 0.4 x 0.6 x 3.5 mm 0.4 x 0.5 x 3.5 mm
1:22 min 1:18 min 1:40 min

AIR™ Recon DL | SIGNA™ Architect Imaging Protocol Courtesy of DASA – Sao Paulo, Brazil 67
T O M O R R OW T OD AY

OrthoWorks
AIR™ Recon DL – Short Acquisition Times

Axial T2 FatSat Coronal T2 FatSat Sagittal PD FSE


Conventional Conventional Conventional
0.5 x 0.7 x 3.0 mm 0.3 x 0.3 x 3.0 mm 0.3 x 0.4 x 3.0 mm
1:04 min 1:25 min 1:52 min

AIR™ Recon DL | SIGNA™ Premier 68


T O M O R R OW T OD AY AIR™ Recon DL AIR™ Recon DL

OrthoWorks
AIR™ Recon DL – Short Acquisition Times

AIR™ Recon DL

Axial T2 FatSat Coronal T2 FatSat Sagittal PD FSE


AIR™ Recon DL AIR™ Recon DL AIR™ Recon DL
0.5 x 0.7 x 3.0 mm 0.3 x 0.3 x 3.0 mm 0.3 x 0.4 x 3.0 mm
1:04 min 1:25 min 1:52 min

AIR™ Recon DL | SIGNA™ Premier 69


T O M O R R OW T OD AY

OrthoWorks
AIR™ Recon DL

Coronal PD FSE
AIR™ Recon DL
0.3 x 0.3 x 3.0 mm
2:04 min

Sagittal PD FSE
Axial T2 FatSat Axial PD FSE AIR™ Recon DL
AIR™ Recon DL AIR™ Recon DL 0.2 x 0.3 x 2.0 mm
0.2 x 0.3 x 2.5 mm 0.2 x 0.3 x 2.5 mm 2:38 min
3:09 min 2:15 min
Conventional

AIR™ Recon DL | SIGNA™ Premier 70


CVWorks
AIR™ Recon DL

AIR™ Recon DL | 3.0T 71


T O M O R R OW T OD AY

CVWorks

Conventional AIR™ Recon DL


Short Axis Black Blood DIR Short Axis Black Blood DIR
Conventional AIR™ Recon DL 1.8 x 1.8 x 8.0 mm
Short Axis LGE Short Axis LGE :11 sec

AIR™ Recon DL | SIGNA™ 72


T O M O R R OW T OD AY

CVWorks

Conventional AIR™ Recon DL Conventional AIR™ Recon DL


Long Axis Triple IR Long Axis Triple IR Short Axis Black Blood Triple IR Short Axis Black Blood Triple IR
1.8 x 1.8 x 10.0 mm 1.8 x 1.8 x 10.0 mm 1.8 x 1.7 x 5.0 mm
1:02 min :34 sec :13 sec

AIR™ Recon DL | SIGNA™ Premier 73


BodyWorks
AIR™ Recon DL

AIR™ Recon DL | 3.0T 74


T O M O R R OW T OD AY

Axial T2 SSFSE FatSat


AIR™ Recon DL
1.3 x 1.8 x 6.0 mm
:17 sec

Coronal SSFSE FatSat


AIR™ Recon DL
1.6 x 1.8 x 1.6 mm
1:13 min

Coronal T2 SSFSE
AIR™ Recon DL
1.4 x 1.6 x 2.0 mm
1:02 min

Conventional
0.2 x 0.2 x 1.6 mm
Axial Dual Echo Axial FIESTA FatSat
AIR™ Recon DL AIR™ Recon DL
1.4 x 2.1 x 6.0 mm 2.1 x 1.3 x 6.0 mm
:12 sec :15 sec
AIR™ Recon DL | SIGNA™ Premier 75
T O M O R R OW T OD AY

BodyWorks
Axial T2 SSFSE FatSat
AIR™ Recon DL
1.3 x 1.8 x 6.0 mm
:17 sec

Coronal SSFSE FatSat


AIR™ Recon DL
1.6 x 1.8 x 1.6 mm
1:13 min

Coronal T2 SSFSE
AIR™ Recon DL
1.4 x 1.6 x 2.0 mm
1:02 min

Conventional
0.2 x 0.2 x 1.6 mm
Axial Dual Echo Axial FIESTA FatSat
AIR™ Recon DL AIR™ Recon DL
1.4 x 2.1 x 6.0 mm 2.1 x 1.3 x 6.0 mm
:12 sec :15 sec
AIR™ Recon DL | SIGNA™ Premier 76
T O M O R R OW T OD AY

BodyWorks
AIR™ Recon DL – PI-RADS® Compliant with Short Acquisition Times
Male Pelvis (Prostate)

AIR™ Recon DL AIR™ Recon DL


PI-RADS® protocol 0.4 PI-RADS® protocol
x 0.7 x 3.0 mm 3:29 0.4 x 0.7 x 3.0 mm
min 2:49 min
AIR™ Recon DL can enable higher resolution images and shorter scan times when compared to conventionally reconstructed images.

AIR™ Recon DL | SIGNA™ Pioneer 77


T O M O R R OW T OD AY

BodyWorks
AIR™ Recon DL – Complete Exam in ~14:00 minutes

PEI / T2 Fusion
via READY View

Dynamic LAVA
Sagittal T2 frFSE Coronal T2 frFSE Axial T2 frFSE 1.9 x 1.9 x 3.0 mm
0.7 x 0.8 x 3.0 mm 0.6 x 0.8 x 3.0 mm 0.7 x 0.8 x 3.0 mm :08 sec per phase
1:34 min/ 27 Slices 1:42 min/ 27 Slices 1:21 min/ 27 Slices

Axial FOCUS DWI (b50/800)


2.0 x 3.0 x 4.0 mm
4:12 min/ 22 Slices

b50 b500 b850 MAGiC DWI b1500 ADC

SIGNA™ Pioneer AIR™ IQ Edition Images courtesy of Houston Medical Imaging, USA 78
T O M O R R OW T OD AY

BodyWorks
AIR™ Recon DL – Short Acquisition Times
Female Pelvis

Axial T2 FSE
AIR™ Recon DL
0.5 x 0.5 x 2.0 mm
27 slices
3:26 min

Sagittal T2 FSE
AIR™ Recon DL
0.5 x 0.5 x 2.0 mm
33 slices
2:15 min

AIR™ Recon DL | SIGNA™ Premier 79


HyperSpeed Protocols
Reduce exam times to under 5
minutes without sacrificing
resolution or signal

AIR™ Recon DL | 3.0T 80


T O M O R R OW T OD AY

HyperSpeed Protocols
Enabled with AIR™ Recon DL
By taking advantage
of increased SNR,
AIR™ Recon DL will
allow a reduction in
the number of signal
averages and/or
increasing parallel
imaging factors. This
will reduce acquisition
times without the
concern of producing
noisy images.

HyperSpeed Protocols
allows maintaining the
same voxel dimensions
as a usual routine
protocol at a fraction
of the time while
improving image
sharpness or apparent
spatial resolution.

AIR™ Recon DL | SIGNA™ 81


T O M O R R OW T OD AY

OrthoWorks with HyperSpeed


Enabled with AIR™ Recon DL
Total Exam Time
4:41 min

Sagittal T2 FatSat Coronal PD FSE Coronal T1 FSE


0.3 x 0.6 x 3 mm 0.4 x 0.7 x 3 mm 0.3 x 0.6 x 3 mm
:52 sec :50 sec 1:07 min

Sagittal PD FSE Axial PD FatSat


0.3 x 0.6 x 3 mm 0.4 x 0.6 x 3 mm
:55 sec :57 sec
AIR™ Recon DL | Discovery MR750w 82
T O M O R R OW T OD AY

OrthoWorks with HyperSpeed


Enabled with AIR™ Recon DL
Total Exam Time 4:58 min

Axial T2 FatSat Axial PD FSE


0.4 x 0.6 x 3 mm 0.3 x 0.4 x 3 mm
:48 sec :55 sec

Sagittal PD FSE Sagittal T2 FatSat Coronal T2 FatSat


0.2 x 0.4 x 3 mm 0.3 x 0.6 x 3 mm 0.4 x 0.6 x 3 mm
1:05 sec 1:06 sec 1:04 min

AIR™ Recon DL | SIGNA™ Premier 83


T O M O R R OW T OD AY

OrthoWorks with HyperSpeed


Enabled with AIR™ Recon DL
Total Exam Time
5:03 min

Axial PD FSE Axial PD FatSat


0.2 x 0.4 x 3 mm 0.3 x 0.5 x 3.0 mm
:44 sec 1:18 min

Sagittal T2 FatSat
Arm positioned 0.3 x 0.6 x 3 mm
at the side :43 sec

Coronal PD FSE Coronal PD FatSat


0.2 x 0.4 x 2.5 mm 0.3 x 0.6 x 2.5 mm
:49 sec 1:29 min

AIR™ Recon DL | SIGNA™ Premier 84


T O M O R R OW T OD AY

NeuroWorks with HyperSpeed


Enabled with AIR™ Recon DL
Total Exam Time
3:40 min

Sagittal T1 FSE Axial T2 FSE Axial T2 FLAIR


0.9 x 1.1 x 5 mm 0.5 x 1.1 x 5.0 mm 0.9 x 1.2 x 5 mm
:43 sec :37 sec 1:21 min

Axial DWI with HyperBand


Axial T2* GRE 0.9 x 1.2 x 5 mm
0.8 x 1.5 x 5 mm :25 sec
:34 sec (acquired with conventional
reconstruction)
AIR™ Recon DL | Discovery MR750w 85
T O M O R R OW T OD AY

NeuroWorks with HyperSpeed


Enabled with AIR™ Recon DL
Total Exam Time 3:43 min

Axial T2 FSE
0.5 x 0.9 x 4 mm
:42 sec

Sagittal T2 FSE Sagittal T1 FSE Sagittal STIR FSE


0.7 x 0.9 x 3 mm 0.7 x 1.1 x 3 mm 0.7 x 1.2 x 3 mm
:57 sec 1:22 min 1:24 min

AIR™ Recon DL | Discovery MR750w 86


T O M O R R OW T OD AY

NeuroWorks with HyperSpeed


Enabled with AIR™ Recon DL
Total Exam Time 4:10 min

Sagittal T2 FSE Sagittal T1 FSE Sagittal T2 STIR Axial T2 FSE


0.6 x 0.9 x 3.5 mm 0.8 x 1 x 3.5 mm 0.7 x 1 x 3.5 0.7 x 0.9 x 4 mm
:50 sec 1:08 min 1:29 min :43 sec

AIR™ Recon DL | Discovery MR750w 87


T O M O R R OW T OD AY

NeuroWorks with HyperSpeed


Enabled with AIR™ Recon DL
Total Exam Time 4:10 min

Sagittal T2 FSE Sagittal T1 FSE Sagittal T2 STIR Axial T2 FSE


0.6 x 0.9 x 3.5 mm 0.8 x 1 x 3.5 mm 0.7 x 1 x 3.5 0.7 x 0.9 x 4 mm
:50 sec 1:08 min 1:38 min :40 sec

AIR™ Recon DL | SIGNA™ Premier 88


T O M O R R OW T OD AY

BodyWorks with HyperSpeed


Enabled with AIR™ Recon DL
Meets PI-RADS resolution requirements
Total Time (T2 and Dynamics)
8:14 min

Sagittal T2 FSE Axial T2 FSE Coronal T2 FSE Axial DISCO FatSat


0.4 x 0.7 x 3 mm 0.4 x 0.7 x 3 mm 0.4 x 0.7 x 3 mm 1.6 x 1.6 x 3.0 mm
1:27 min 1:44 min 1:35 min 3:28 min

AIR™ Recon DL | SIGNA™ Premier 89