GJJD44-LS INDUSTRIAL RANGE
GENERATING SETS WATER COOLED THREE PHASES 50 HZ DIESEL
Service Standby Prime
Power kVA 44 40
Power kW 35,2 32
Rated Speed r.p.m 1500
Standart Voltage V 400/230
Rated At Power Factor Cos Phi 0,8
GUCBIR Company with quality certification ISO 9001:2015, ISO 10002:2014, ISO 14001:2015, OHSAS 18001:2007,
TS ISO IEC 25051:2015,
GUCBIR gensets are compliant with CE mark which includes the following directives:
• 2006/42/EC Machinery safety.
• 2014/30/EU Electromagnetic compatibility.
• 2014/35/EU Electrical equipment designed for use within certain voltage limits
• 2000/14/EC Sound Power level. Noise emissions outdoor equipment. (amended by 2005/88/EC)
• EN 12100:2010, TS EN 60201-1, EN 55011, EN 61000-6-4, EN 61000-4-11, EN 61000-4-8, EN 610000-4-5,
EN 610000-4-2, EN 610000-4-2, EN 12601, TS ISO 8528-1-12
GUCBIR JENERATOR SAN. VE TIC. A.Ş.
+90 216 312 7979 Serifali Mahallesi, Tavukcuyolu Cad. No:200 - Umraniye / ISTANBUL / TURKIYE
T: +90 216 312 79 79 | F: +90 216 312 79 77
[email protected] [email protected] | www.gucbirjenerator.com
GJJD44-LS INDUSTRIAL RANGE
SPECIFICATIONS
Engine Alternator
Engine Specifications Alternator Specifications
Manufacturer JOHN DEERE Manufacturer Leroy Somer
Model 3029TFG20 Model TAL046-E/TAL-A46-E
Engine Type 4 Stroke - Diesel Output Voltage V 230/400
Injection Type Direct Frequency HZ 50
Aspiration Type Turbocharged Automatic Voltage Regulation ±% 1
Number of cylinder 44
3 cylinder Alternator Standby Power kVA
Bore and Stroke mm 40
106 x110 Alternator Continuous Power kVA
Displacement L 2,9 Power Factor Cosq 0,8
Cooling System Number of Wires 12
Water Cooling
Fuel Consumption 50% PRP l/h 4.5 Winding 2/3
Fuel Consumption 75% PRP l/h 6.5 Protection Class IP23 / H
Fuel Consumption 100 % PRP l/h 8.5 Excition System Self Excited
Fuel Consumption Standby l/h 9.2 AVR Model R120
Compression ratio 17.2:1 Performance - PF 0,8 / %75 Load % 89,6
Total oil capacity including tubes, filters L 8
Total coolant capacity L 13,3
Governor Type Mechanical
Electric system voltage(V) V 24
Prime Power (PRP):
According to ISO 8528-1:2005, Prime power is the maximum power which a generating set is capable of delivering continuously whilst supplying a vari-
able electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and
procedures being carried out as prescribed by the manufacturer. The permissible average power output (Ppp) over 24 h of operation shall not exceed 70 %
of the PRP.
Emergency Standby Power (ESP):
According to ISO 8528-1:2005, Emergency standby power is the maximum power available during a variable electrical power sequence, under the stated
operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of ope-
ration per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output
over 24 h of operation shall not exceed 70 % of the ESP.
Note: All data based on operation to ISO 3046/1, BS 5514 and DIN 6271 standard reference conditions
GUCBIR JENERATOR SAN. VE TIC. A.Ş.
+90 216 312 7979 Serifali Mahallesi, Tavukcuyolu Cad. No:200 - Umraniye / ISTANBUL / TURKIYE
T: +90 216 312 79 79 | F: +90 216 312 79 77
[email protected] [email protected] | www.gucbirjenerator.com
GJJD44-LS INDUSTRIAL RANGE
DIMENSIONS
OPEN SET
LxWxH mm 1770x850x11440
Weight kg 810
Fuel Tank lt 135
CANOPIED
LxWxH mm 2225x950x1660
Weight kg 1180
Fuel Tank lt 135
Sound Proof Canopy
• Special design for minimizing acoustic level.
• Galvanized steel construction further protected by polyester powder coat paint.
• Black finish stainless steel locks and hinges.
• Control panel viewing window in a lockable access door.
• Emergency stop push button (red) mounted on enclosure exterior.
• Lifting, drag and jacking points on base frame.
• Radiator fill via removable, flush mounted rain cap fitted with compression seal.
• Acoustic insulation with moisture-repellent and non-flammable material
GUCBIR JENERATOR SAN. VE TIC. A.Ş.
+90 216 312 7979 Serifali Mahallesi, Tavukcuyolu Cad. No:200 - Umraniye / ISTANBUL / TURKIYE
T: +90 216 312 79 79 | F: +90 216 312 79 77
[email protected] [email protected] | www.gucbirjenerator.com
GJJD44-LS INDUSTRIAL RANGE
CONTROL UNIT
Control Unit
GB500 - DATAKOM
ATS unit with uninterrupted transfer Internet Central Monitoring
AMF unit with uninterrupted transfer SMS / E-mail message sending
Remote / Manuel start controller Flexible with plug-in modules
Engine controller Free PC software: Rainbow Plus
GSM-GPRS-GPS-Ethernet Port Modbus RTU
8 configurable digital inputs
ATS PANEL
GUCBIR automatic transfer switches are reliable, rugged, versatile, and compact assemblies for
transferring essential loads and electrical distribution systems from one power source to another.GUCBIR ’s
contactor based transfer switch is rated 40–3600A and can be supplied in separate enclosures for
standalone applications or can be supplied as an integral component Contactors inside the ATS
panels are well known and internationally recognized brands such as ABB, SIEMENS, SCHNEIDER, GE, LS,
HYUNDAI, TELERGON, SOCOMEC and ANDELI.
OPTIONAL EQUIPMENTS
Some Optional Equipments that GUCBIR prov ides with Generator Sets; Control Panel
• Medium voltage alternator, • DeepSea 7320
• Remote radiator applications, • Datakom D700/D300/D309/D200
• Automatic fuel filling system, • ComAp AMF9
• Fuel tank, oil pan, dashboard, alternator, coil heaters, • ComAp AMF25
• Alternator with double AVR and PMG,
• Synchronization systems, The generator output breaker,
• Grid-generator transfer switches,
• Accordance with the specific volume of demand-insulated cabins,
• Seismic solutions,
• Trailer,
• Remote monitoring.
• SMPS 12/24V 10A
GUCBIR JENERATOR SAN. VE TIC. A.Ş.
+90 216 312 7979 Serifali Mahallesi, Tavukcuyolu Cad. No:200 - Umraniye / ISTANBUL / TURKIYE
T: +90 216 312 79 79 | F: +90 216 312 79 77
[email protected] [email protected] | www.gucbirjenerator.com