Inputoutput Soot
Inputoutput Soot
BOOL BOOLS
CLOCK DINT[7]
CLOCK_UPDATE DINT[7]
COMMON_ALARM COMMON_ALARMS
COMPACTLOGIX_ANALOG_AOI CompactLogix_Analog_Scale
Connection_Input MCMConnectionInput Connection pin for the Add-On instruction.
HMI_DINT HMI_DINTS
Local:1:C AB:1769_IQ6XOW4:C:0
Local:1:I AB:1769_IQ6XOW4:I:0
Local:1:O AB:1769_IQ6XOW4:O:0
Local:2:C AB:1769_MODULE:C:0
Local:2:I AB:1769_MODULE_INT_488Byte
s:I:0
Local:2:O AB:1769_MODULE_INT_482Byte
s:O:0
MAIN_DINT MAIN_DINTS
PLC_DAY_UPDATE DINT
PLC_HOUR DINT
PLC_HOUR_UPDATE DINT
PLC_MIN DINT
PLC_MIN_UPDATE DINT
PLC_MONTH DINT
PLC_MONTH_UPDATE DINT
PLC_SEC DINT
PLC_SEC_UPDATE DINT
PLC_YEAR DINT
RSLogix 5000
NEM_2_110952 - Controller Tag Listing Page 2
NEM_2_110952 (Controller) 10/18/2024 8:07:45 PM
D:\3. PLC\022WHB401 - SootBlower - Copy\PLC\20180919_NEM_2_110952_REV_5.ACD
RACK_1:0:C AB:1794_IB32:C:0
RACK_1:0:I AB:1794_IB32:I:0
RACK_1:0:I.Fault DINT
RACK_1:0:I.Data DINT
RSLogix 5000
NEM_2_110952 - Controller Tag Listing Page 3
NEM_2_110952 (Controller) 10/18/2024 8:07:45 PM
D:\3. PLC\022WHB401 - SootBlower - Copy\PLC\20180919_NEM_2_110952_REV_5.ACD
RACK_1:1:I AB:1794_IB32:I:0
RACK_1:1:I.Fault DINT
RACK_1:1:I.Data DINT
RACK_1:1:I.Data.0 BOOL WHB SLS_11
RSLogix 5000
NEM_2_110952 - Controller Tag Listing Page 4
NEM_2_110952 (Controller) 10/18/2024 8:07:45 PM
D:\3. PLC\022WHB401 - SootBlower - Copy\PLC\20180919_NEM_2_110952_REV_5.ACD
RACK_1:2:C AB:1794_IB32:C:0
RACK_1:2:I AB:1794_IB32:I:0
RACK_1:2:I.Fault DINT
RACK_1:2:I.Data DINT
RSLogix 5000
NEM_2_110952 - Controller Tag Listing Page 5
NEM_2_110952 (Controller) 10/18/2024 8:07:45 PM
D:\3. PLC\022WHB401 - SootBlower - Copy\PLC\20180919_NEM_2_110952_REV_5.ACD
RACK_1:3:I AB:1794_IB32:I:0
RACK_1:3:I.Fault DINT
RACK_1:3:I.Data DINT
RACK_1:3:I.Data.0 BOOL WHB SEAL_AIR_FLOW_SW 1
RSLogix 5000
NEM_2_110952 - Controller Tag Listing Page 6
NEM_2_110952 (Controller) 10/18/2024 8:07:45 PM
D:\3. PLC\022WHB401 - SootBlower - Copy\PLC\20180919_NEM_2_110952_REV_5.ACD
RACK_1:4:C AB:1794_OB32P:C:0
RACK_1:4:I AB:1794_OB32P:I:0
RACK_1:4:O AB:1794_OB32P:O:0
RACK_1:4:O.Data DINT
RSLogix 5000
NEM_2_110952 - Controller Tag Listing Page 7
NEM_2_110952 (Controller) 10/18/2024 8:07:45 PM
D:\3. PLC\022WHB401 - SootBlower - Copy\PLC\20180919_NEM_2_110952_REV_5.ACD
RACK_1:5:O INT
RACK_1:5:O.0 BOOL WHB FWD_CONTACT
RSLogix 5000
NEM_2_110952 - Controller Tag Listing Page 8
NEM_2_110952 (Controller) 10/18/2024 8:07:45 PM
D:\3. PLC\022WHB401 - SootBlower - Copy\PLC\20180919_NEM_2_110952_REV_5.ACD
RACK_1:6:C AB:179x_IE8H:C:0
RACK_1:6:I AB:179x_IE8H:I:0
RACK_1:6:I.Fault DINT
RACK_1:6:I.Ch0Data INT
RACK_1:6:I.Ch1Data INT
RACK_1:6:I.Ch2Data INT
RACK_1:6:I.Ch3Data INT
RACK_1:6:I.Ch4Data INT
RACK_1:6:I.Ch5Data INT
RACK_1:6:I.Ch6Data INT
RACK_1:6:I.Ch7Data INT
RACK_1:6:I.Alarms INT
RACK_1:6:I.Ch0LAlarm BOOL
RACK_1:6:I.Ch1LAlarm BOOL
RACK_1:6:I.Ch2LAlarm BOOL
RACK_1:6:I.Ch3LAlarm BOOL
RACK_1:6:I.Ch4LAlarm BOOL
RACK_1:6:I.Ch5LAlarm BOOL
RACK_1:6:I.Ch6LAlarm BOOL
RACK_1:6:I.Ch7LAlarm BOOL
RACK_1:6:I.Ch0HAlarm BOOL
RACK_1:6:I.Ch1HAlarm BOOL
RACK_1:6:I.Ch2HAlarm BOOL
RACK_1:6:I.Ch3HAlarm BOOL
RACK_1:6:I.Ch4HAlarm BOOL
RACK_1:6:I.Ch5HAlarm BOOL
RACK_1:6:I.Ch6HAlarm BOOL
RACK_1:6:I.Ch7HAlarm BOOL
RACK_1:6:I.OutOfRange SINT
RACK_1:6:I.Ch0OutOfRange BOOL
RACK_1:6:I.Ch1OutOfRange BOOL
RACK_1:6:I.Ch2OutOfRange BOOL
RSLogix 5000
NEM_2_110952 - Controller Tag Listing Page 9
NEM_2_110952 (Controller) 10/18/2024 8:07:45 PM
D:\3. PLC\022WHB401 - SootBlower - Copy\PLC\20180919_NEM_2_110952_REV_5.ACD
RACK_1:6:I.Ch4OutOfRange BOOL
RACK_1:6:I.Ch5OutOfRange BOOL
RACK_1:6:I.Ch6OutOfRange BOOL
RACK_1:6:I.Ch7OutOfRange BOOL
RACK_1:6:I.SecondAlarm SINT
RACK_1:6:I.Ch0SecondAlarm BOOL
RACK_1:6:I.Ch1SecondAlarm BOOL
RACK_1:6:I.Ch2SecondAlarm BOOL
RACK_1:6:I.Ch3SecondAlarm BOOL
RACK_1:6:I.Ch4SecondAlarm BOOL
RACK_1:6:I.Ch5SecondAlarm BOOL
RACK_1:6:I.Ch6SecondAlarm BOOL
RACK_1:6:I.Ch7SecondAlarm BOOL
RACK_1:6:I.Status2 INT
RACK_1:6:I.DiagnosticStatus_0 BOOL
RACK_1:6:I.DiagnosticStatus_1 BOOL
RACK_1:6:I.DiagnosticStatus_2 BOOL
RACK_1:6:I.DiagnosticStatus_3 BOOL
RACK_1:6:I.HARTRebuild BOOL
RACK_1:6:I.Ch0HARTFault BOOL
RACK_1:6:I.Ch1HARTFault BOOL
RACK_1:6:I.Ch2HARTFault BOOL
RACK_1:6:I.Ch3HARTFault BOOL
RACK_1:6:I.Ch4HARTFault BOOL
RACK_1:6:I.Ch5HARTFault BOOL
RACK_1:6:I.Ch6HARTFault BOOL
RACK_1:6:I.Ch7HARTFault BOOL
RACK_1:6:I.Ch0HARTCurrentFault BOOL
RACK_1:6:I.Ch1HARTCurrentFault BOOL
RACK_1:6:I.Ch2HARTCurrentFault BOOL
RACK_1:6:I.Ch3HARTCurrentFault BOOL
RACK_1:6:I.Ch4HARTCurrentFault BOOL
RSLogix 5000
NEM_2_110952 - Controller Tag Listing Page 10
NEM_2_110952 (Controller) 10/18/2024 8:07:45 PM
D:\3. PLC\022WHB401 - SootBlower - Copy\PLC\20180919_NEM_2_110952_REV_5.ACD
RACK_1:6:I.Ch6HARTCurrentFault BOOL
RACK_1:6:I.Ch7HARTCurrentFault BOOL
RACK_1:6:I.Ch0HARTCommunication BOOL
RACK_1:6:I.Ch1HARTCommunication BOOL
RACK_1:6:I.Ch2HARTCommunication BOOL
RACK_1:6:I.Ch3HARTCommunication BOOL
RACK_1:6:I.Ch4HARTCommunication BOOL
RACK_1:6:I.Ch5HARTCommunication BOOL
RACK_1:6:I.Ch6HARTCommunication BOOL
RACK_1:6:I.Ch7HARTCommunication BOOL
RACK_1:6:I.Ch0TransmitterPresent BOOL
RACK_1:6:I.Ch1TransmitterPresent BOOL
RACK_1:6:I.Ch2TransmitterPresent BOOL
RACK_1:6:I.Ch3TransmitterPresent BOOL
RACK_1:6:I.Ch4TransmitterPresent BOOL
RACK_1:6:I.Ch5TransmitterPresent BOOL
RACK_1:6:I.Ch6TransmitterPresent BOOL
RACK_1:6:I.Ch7TransmitterPresent BOOL
RACK_1:6:I2 AB:179x_HARTDATA:I2:0
RACK_1:6:I2.Fault DINT
RACK_1:6:I2.Ch0HARTCmd3Status BOOL
RACK_1:6:I2.Ch1HARTCmd3Status BOOL
RACK_1:6:I2.Ch2HARTCmd3Status BOOL
RACK_1:6:I2.Ch3HARTCmd3Status BOOL
RACK_1:6:I2.Ch4HARTCmd3Status BOOL
RACK_1:6:I2.Ch5HARTCmd3Status BOOL
RACK_1:6:I2.Ch6HARTCmd3Status BOOL
RACK_1:6:I2.Ch7HARTCmd3Status BOOL
RACK_1:6:I2.Ch0HART AB:1794_HARTPV_Struct:I:0
RACK_1:6:I2.Ch0HART.CommunicationStat SINT
us
RACK_1:6:I2.Ch0HART.FieldDeviceStatus SINT
RACK_1:6:I2.Ch0HART.LoopStatus SINT
RSLogix 5000
NEM_2_110952 - Controller Tag Listing Page 11
NEM_2_110952 (Controller) 10/18/2024 8:07:45 PM
D:\3. PLC\022WHB401 - SootBlower - Copy\PLC\20180919_NEM_2_110952_REV_5.ACD
RACK_1:6:I2.Ch0HART.SV REAL
RACK_1:6:I2.Ch0HART.TV REAL
RACK_1:6:I2.Ch0HART.FV REAL
RACK_1:6:I2.Ch0HART.PVUnitsCode SINT
RACK_1:6:I2.Ch0HART.SVUnitsCode SINT
RACK_1:6:I2.Ch0HART.TVUnitsCode SINT
RACK_1:6:I2.Ch0HART.FVUnitsCode SINT
RACK_1:6:I2.Ch1HART AB:1794_HARTPV_Struct:I:0
RACK_1:6:I2.Ch1HART.CommunicationStat SINT
us
RACK_1:6:I2.Ch1HART.FieldDeviceStatus SINT
RACK_1:6:I2.Ch1HART.LoopStatus SINT
RACK_1:6:I2.Ch1HART.PV REAL
RACK_1:6:I2.Ch1HART.SV REAL
RACK_1:6:I2.Ch1HART.TV REAL
RACK_1:6:I2.Ch1HART.FV REAL
RACK_1:6:I2.Ch1HART.PVUnitsCode SINT
RACK_1:6:I2.Ch1HART.SVUnitsCode SINT
RACK_1:6:I2.Ch1HART.TVUnitsCode SINT
RACK_1:6:I2.Ch1HART.FVUnitsCode SINT
RACK_1:6:I2.Ch2HART AB:1794_HARTPV_Struct:I:0
RACK_1:6:I2.Ch3HART AB:1794_HARTPV_Struct:I:0
RACK_1:6:I2.Ch4HART AB:1794_HARTPV_Struct:I:0
RACK_1:6:I2.Ch5HART AB:1794_HARTPV_Struct:I:0
RACK_1:6:I2.Ch6HART AB:1794_HARTPV_Struct:I:0
RACK_1:6:I2.Ch7HART AB:1794_HARTPV_Struct:I:0
RACK_1:I AB:1794_AEN_8SLOT:I:0
RACK_1:I.SlotStatusBits DINT
RACK_1:I.Data INT[8]
RACK_1:I.Data[0] INT
RACK_1:I.Data[1] INT
RACK_1:I.Data[2] INT
RACK_1:I.Data[3] INT
RSLogix 5000
NEM_2_110952 - Controller Tag Listing Page 12
NEM_2_110952 (Controller) 10/18/2024 8:07:45 PM
D:\3. PLC\022WHB401 - SootBlower - Copy\PLC\20180919_NEM_2_110952_REV_5.ACD
RACK_1:I.Data[5] INT
RACK_1:I.Data[6] INT
RACK_1:I.Data[7] INT
RACK_1:O AB:1794_AEN_8SLOT:O:0
RACK_1:O.Data INT[8]
RACK_1:O.Data[0] INT
RACK_1:O.Data[1] INT
RACK_1:O.Data[2] INT
RACK_1:O.Data[3] INT
RACK_1:O.Data[4] INT
RACK_1:O.Data[5] INT
RACK_1:O.Data[6] INT
RACK_1:O.Data[7] INT
SCR_ECON_ALARM SCR_ECON_ALARMS
SCR_ECON_BLOWER SCR_ECON_BLOWERS[14]
SCR_ECON_PRESS_SCALED CompactLogix_Analog_Scale
SCR_ECON_TEMP_SCALED CompactLogix_Analog_Scale
SEAL_AIR_FAN_ALARM SEAL_AIR_FAN_ALARMS
SKIP_BLOW_DINT SKIP_BLOW_DINTS
TIMER TIMERS
WHB_ALARM WHB_ALARMS
WHB_BLOWER WHB_BLOWERS[22]
WHB_PRESS_SCALED CompactLogix_Analog_Scale
WHB_TEMP_SCALED CompactLogix_Analog_Scale
RSLogix 5000