You are on page 1/ 10

BGM

ENGINEERING, LLC
2123 45TH ROAD, LONG ISLAND CITY, NY 11101
24 CANFIELD DRIVE STAMFORD, CT 06902
1 2 4 5 6 9 10 TEL: 203.452.9408 and 646.499.0685
14'-0" 3'-0" 69'-4" EXISTING FOUNDATION WALL 7'-8" E-MAIL: [email protected]

5" 5'-11" 15'-0" 15'-5" 5'-8" 21'-4 1/2" 6'-5 1/2" 2'-1"

8'-0"

8 1/2"
FW2 FW1 F8.0

2'-0"
4 1/2"
F2.0T F2.0T FW1
A
B

CP1
FW3
F5.0
FC2.0

4" REINFORCED CONCRETE SLAB


OVER VAPOR BARRIER OVER 6"
F4.0 F4.0

LAYER OF GRANULAR FILL

FC3.0
FW3
CP1 4" REINFORCED CONCRETE SLAB CP1

EXISTING FOUNDATION WALL


14'-10" OVER VAPOR BARRIER OVER 6"

14'-6"
LAYER OF GRANULAR FILL
CONC. SLAB EL. -12'-0"

CONC. SLAB

21'-0 1/2"
CP1 12'-0"

FC2.0
F5.0

FW3
F5.0 F12.0
F5.0

2 1/2"

27'-9 1/2"
2 1/2"

C C
D D
40'-0"

35'-3 1/2"

PROJECT:
F2.0T
FW2

4'-11"
P1 P P1 P P E
BW
12'-7 1/2"

FC2.0
FW3
2040 EAST 5TH
FC3.0

17'-0"
FW3

FC2.0
STREET

7'-8 1/2"
P1 FW3
CP1 CP1

FW2
CP1
F5.0 F5.0 F5.0
F4.0 F4.0
FW3
FC3.0
FC3.0
BROOKLYN, NY
F2.0T

1'-0"
F F 11223
1'-4"

FC3.0
FW3
5'-10 1/2"

FW3

6'-6"
F2.0T
FW2

F2.0T
FW2

FC3.0
4
FW2 FO-101
F2.0T
NO. DATE ISSUE/REVISION BY
1 XX/XX/XX PERMIT JB

10'-8" 3'-4" 37'-0" 20'-0" 23'-0"

5" 5'-11" 13'-3" 17'-2 1/2" 7'-5" 19'-7 1/2" 6'-5 1/2" 9'-8 1/2"

1 2 3 5 7 9 10

S I Z E A N D R E I N F O R C E M E N T S C H E D U L E OF C O N C R E T E F O O T I N G

BOTTOM REINF. TOP REINF.


FOOTING COMMENTS
TYPE WIDTH LENGTH DEPTH PARALLEL PARALLEL PARALLEL PARALLEL
TO LENGTH TO WIDTH TO LENGTH TO WIDTH DRAWING TITLE:

NOTES: FC2.0 2'-0" CONT 1'-0" (3)#5 #5 @12"

1 FOUNDATION PLAN 1. ALL DIMENSIONS AND ELEVATIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS AND VERIFY IN FIELD.
1 FC2.0T 2'-0" CONT 1'-0" (3)#5 #5 @12" (3)#5 #5 @12" TOP BAR HOOKED AT ENDS
FO-100 SCALE: 4"=1'-0"
2. DENOTES TYPE OF CONCRETE PIER. SEE SCHEDULE FOR SIZES AND REINF.
CP#

3. F# DENOTES TYPE OF FOOTING. SEE SCHEDULE FOR SIZES AND REINF. FC3.0 3'-0" CONT 1'-6" (4)#5 #5 @12"

4. FC# DENOTES TYPE OF CONTINUOUS FOOTING. SEE SCHEDULE FOR SIZES AND REINF. FOUNDATION
F4.0 4'-0" 4'-0" 1'-6" (5)#5 (5)#5
5.

6.
FW# DENOTES TYPE OF FOUNDATION WALL. SEE SCHEDULE FOR SIZES AND REINFORCEMENT.

DENOTES NEW BEARING LIGHT GAGE WALL FRAMING. SEE SCHEDULE AND TYPICAL DETAILS.
PLAN
F5.0 5'-0" 5'-0" 1'-6" (6)#5 (6)#5
BW

F8.0 2'-0" 8'-0" 1'-0" (3)#5 (9)#5

F12.0 5'-0" 12'-0" 1'-6" (6)#5 (13)#5

M A T E R I A L A N D R E I N F O R C E M E N T S C H E D U L E OF C O N C R E T E F O U N D A T I O N W A L L

CONCRETE WALL
LOCATION SIZE & MATERIAL HORIZONTAL REINF SIZE AND SPACING VERTICAL REINF SIZE AND SPACING REMARKS SEAL AND SIGNATURE
TYPE DATE: 04/15/22

#5 @ 12" O.C. CONT. (MIDDLE WALL)


FW1 SEE PLAN 8" Fc=4.000 PSI #5 @ 12" O.C. (MIDDLE WALL) PROJECT No: BGM 22-029
(2)#5 CONT. @ TOP & BOTT

#5 @ 12" O.C. CONT. (MIDDLE WALL) DRAWING BY: IK


FW2 SEE PLAN 10" Fc=4.000 PSI (2)#5 CONT. @ TOP & BOTT #5 @ 12" O.C. (MIDDLE WALL)
CHK BY: AK

FW3 CELLAR 12" Fc=4.000 PSI #5 @ 12" O.C. CONT. (BOTH FACES) #5 @ 12" O.C. (BOTH FACES) DWG No:

M A T E R I A L A N D R E I N F O R C E M E N T S C H E D U L E OF C O N C R E T E P I E R
FO-100.00
CONCRETE PIER REMARKS
LOCATION SIZE & MATERIAL HORIZONTAL REINF SIZE AND SPACING VERTICAL REINF SIZE AND SPACING
TYPE
BGM 22-029 X of X
#3 @ 12" O.C. STIRR
CP1 CELLAR 14"x12" Fc=4.000 PSI (6)#5 CONT.
(3)#3 @ 3" O.C. STIRR AT TOP

DOB JOB #
BGM
ENGINEERING, LLC
2123 45TH ROAD, LONG ISLAND CITY, NY 11101
24 CANFIELD DRIVE STAMFORD, CT 06902
TEL: 203.452.9408 and 646.499.0685
1 2 4 5 6 8 9 10 E-MAIL: [email protected]
14'-0" 3'-0" 69'-4" EXISTING FOUNDATION WALL 7'-8"

5" 5'-11" 15'-0" 15'-5" 5'-8" 13'-9 1/2" 7'-7" 6'-5 1/2" 2'-1"

8 1/2"
4 1/2"
W14x22
A
B

BRIDGING @8'-0" O.C.

4" REINFORCED CONCRETE SLAB


OVER VAPOR BARRIER OVER 6"
LAYER OF GRANULAR FILL

1000JR200-54@16" O.C.

EXISTING FOUNDATION WALL


14'-10"

14'-6"
CONC. SLAB

21'-0 1/2"
2 1/2"

27'-9 1/2"
2 1/2"

C W10x39 W10x19 W10x15 W12x120 W10x15 C


D D
BRIDGING @8'-0" O.C. PROJECT:
40'-0"

1000JR200-54

1000JR200-54

1000JR200-54

1000JR200-54
35'-3 1/2"

@16" O.C.

@16" O.C.

@16" O.C.

4'-11"
@16" O.C.

BH
BH
BH BW

1000JR200-54
2040 EAST 5TH
BH

1000JR200-54 @16" O.C.


P1 P H P1 P H P W10x15 E

@16" O.C.
1000JR200-54 @16" O.C.

BH

W10x45
12'-7"

[-1'-9"]
BH [-1'-9"]

STREET

BH [-1'-9"]

BH [-1'-9"]

BH

W10x15
BH

1000JR200-54

7'-8"
P1
BH [-1'-9"]
BROOKLYN, NY

@16" O.C.
[-1'-9"]
BRIDGING @8'-0" O.C.

11223
1'-4 1/2"

1'-0"
F F
P P P P P1 P1
G
W10x15 [-1'-9"] W10x30 [-1'-9"] W10x60 [-1'-9"]
5'-10 1/2"

6'-6"
NO. DATE ISSUE/REVISION BY
1 XX/XX/XX PERMIT JB

10'-8" 3'-4" 37'-0" 20'-0" 23'-0"

5" 5'-11" 13'-3" 17'-2 1/2" 7'-5" 12'-0 1/2" 7'-7" 6'-5 1/2" 9'-8 1/2"

1 2 3 5 7 8 9 10
DRAWING TITLE:

1 FIRST FLOOR FRAMING PLAN OVER CELLAR PLAN NOTES:

S-100 SCALE: 41"=1'-0" 1. ALL DIMENSIONS AND ELEVATIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS AND VERIFIED IN FIELD.

2.
XXX
@16" O.C.
DENOTES ORIENTATION AND DESIGNATION OF FLOOR JOIST DESIGNATION BASED ON MARINOWARE CATALOG.
SEE MANUFACTURER INSTALLATION RECOMMENDATIONS FOR LIGHT GAGE JOIST INSTALLATION REQUIREMENTS. FIRST FLOOR
#10 TEK SCREW
#10 TEK SCREW
@ 12"o.c. TYP. XXXTXXX-XX
3. DENOTES 34" USG STRUCTURAL PANEL CONCRETE SUBFLOOR. FOR CONNECTION USE CORROSION RESISTANT
SELF-COUNTERSINKING HEAD SCREWS SUCH AS HILTI PWH SD CEMENT BOARD FASTENERS, PART #00372760, OR EQUAL.
FASTENERS TO BE MINIMUM #8 DIAMETER @12" O.C. WITH S-12 SELF-DRILLING "TEK" POINTS. LENGTH = 2 TO 3 TIMES THE BOARD
FRAMING PLAN
@ 12"o.c. TYP.
THICKNESS. SEAT SCREW HEADS FLUSH WITH PANEL SURFACE, DO NOT OVER DRIVE SCREWS. SCREW FASTENERS TO MAINTAIN
XXXSXXX-XX
XXXSXXX-XX

XXXSXXX-XX
XXXSXXX-XX

¾” DISTANCE FROM ALL BOARD EDGES. SCREW FASTENERS TO MAINTAIN MINIMUM OF 2” DISTANCE FROM BOARD CORNERS ON
ONE SIDE AND 4" DISTANCE ON ANOTHER SIDE OF CORNER AND OFFSET FASTENERS TO AVOID 45 DEGREE FASTENER PLACEMENT
AT BOARD CORNERS. DO NOT OVERDRIVE FASTENERS. FOLLOW MANUFACTURER’S INSTALLATION INSTRUCTIONS.

4. DENOTES ORIENTATION OF 1.5C 20 GAUGE GALVANIZED CONFORM STEEL DECK BY VULCRAFT. FLOOR CONSTRUCTION IS
OPENING 3" NORMAL WEIGHT CONCRETE REINFORCED W/6X6-W 2.9X2.9 WWF. TOTAL FLOOR THICKNESS IS 421".
OPENING XXXTXXX-XX 5. BH DENOTES BOX HEADER MADE OF (2)1000S200-97 + (2) 600T125-97 TRACKS.
BH-1 DENOTES BOX HEADER MADE OF (3)1000S200-97 + (2) 600T125-97 TRACKS.USE MANUFACTURER'S RECOMMENDATIONS FOR
FASTENERS REQUIREMENTS. ALL MEMBERS TO BE CONTINUOUS. DO NOT SPLICE MEMBERS. THIS APPLIES TO BOTH STUD
AND TRACK.
POST HEADER SEAL AND SIGNATURE DATE: 04/15/22
6. DENOTES NEW BEARING LIGHT GAGE WALL FRAMING. SEE SCHEDULE AND TYPICAL DETAILS.
BW PROJECT No: BGM 22-029
WALL FRAMING SCHEDULE OPENING FRAMING SCHEDULE
DRAWING BY: IK
OPENINGS
WALL LOCATION BW WALL LOCATION H HEADER H HEADER
P (POST) P1 (POST) (4 FT WIDE MAX) (6 FT WIDE MAX) CHK BY: AK

ATTIC - ROOF 600S162-43 @16" O.C. ATTIC FLOOR -ATTIC FLOOR CEILING 600S300-97 DWG No:
2ND FLOOR -ATTIC FLOOR 600S162-54 @16" O.C. 2ND FLOOR -ATTIC FLOOR 600S300-97
(2)600S300-97 (2)362S200-54W/(2)600T125-54 (2)600S200-54W/(2)600T125-54
1ST FLOOR - 2ND FLOOR 600S250-54 @16" O.C. 1ST FLOOR -2ND FLOOR 600S300-97 S-100.00
CELLAR - 1ST FLOOR 600S162-43 @16" O.C. CELLAR - 1ST FLOOR 600S300-97

NOTE:
1. TRACK TOP AND BOTTOM TO BE 600T125-XX AND GAGE TO MATCH WALL STUD.
BGM 22-029 X of X

DOB JOB #
BGM
ENGINEERING, LLC
2123 45TH ROAD, LONG ISLAND CITY, NY 11101
24 CANFIELD DRIVE STAMFORD, CT 06902
TEL: 203.452.9408 and 646.499.0685
1 2 4 5 5.1 7.1 8 10 E-MAIL: [email protected]

5" 5'-11" 15'-0" 15'-5" 19'-5 1/2" 14'-0 1/2" 2'-1"

W10x15

CANT
4 1/2"

8 1/2"
CANT
A
BH P1 B
P1 BH P1 P1 BW P H P P P P1 BW
MC

P1
BRIDGING @8'-0" O.C.
BH BH

P1

W10x

W10x

1000JR200-54 @16" O.C.

1000JR200-97 @16" O.C.

1000JR200-54 @16" O.C.


W10x15

14'-8 1/2"
14'-10"

W10x15
BH
BH

BH

BH

BH
BH
P1

BH

BW
BH
P1

W12x
2 1/2"

29'-9 1/2"

C BH P1
D D

CANT

CANT
W10x77 W10x19 W10x39 DROPPED W10x15 PROJECT:
P1 BRIDGING @8'-0" O.C. BH
BH BRIDGING @8'-0" O.C.

4'-11"
1000JR200-54 P1
@16" O.C.
BH MC

1000JR200-54 @16" O.C.


E
2040 EAST 5TH
12'-7 1/2"

1000JR200-54 @16" O.C.

BH
BRIDGING @8'-0" O.C.

P1

STREET
W10x

W10x

W10x

W10x
P

7'-8 1/2"
BH BROOKLYN, NY
P

P1 BH P1
P P H P BW P1 BH
P1 11223
F F
1'-4"

BW BW
P1 P BH P1 P1 P1 BH P1 P1 P1 BH P1
BH

3'-7 1/2"
CANT

CANT
G

BRIDGING @8'-0" O.C.


P H
BW

BW
7'-9"

1000JR200-68

H
@16" O.C.

NO. DATE ISSUE/REVISION BY


P
1 XX/XX/XX PERMIT JB

BW

10'-8"

4 1/2" 5'-11" 15'-0" 15'-5" 7'-5" 12'-0 1/2" 14'-0 1/2"

2'-0 1/2"

1 2 4 5 7 8 10
DRAWING TITLE:

1 SECOND FLOOR FRAMING PLAN OVER FIRST FLOOR PLAN NOTES:

S-101 SCALE: 41"=1'-0" 1. ALL DIMENSIONS AND ELEVATIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS AND VERIFIED IN FIELD.

2.
XXX
@16" O.C.
DENOTES ORIENTATION AND DESIGNATION OF FLOOR JOIST DESIGNATION BASED ON MARINOWARE CATALOG.
SEE MANUFACTURER INSTALLATION RECOMMENDATIONS FOR LIGHT GAGE JOIST INSTALLATION REQUIREMENTS. SECOND FLOOR
#10 TEK SCREW
#10 TEK SCREW
@ 12"o.c. TYP. XXXTXXX-XX
3. DENOTES 34" USG STRUCTURAL PANEL CONCRETE SUBFLOOR. FOR CONNECTION USE CORROSION RESISTANT
SELF-COUNTERSINKING HEAD SCREWS SUCH AS HILTI PWH SD CEMENT BOARD FASTENERS, PART #00372760, OR EQUAL.
FASTENERS TO BE MINIMUM #8 DIAMETER @12" O.C. WITH S-12 SELF-DRILLING "TEK" POINTS. LENGTH = 2 TO 3 TIMES THE BOARD
FRAMING PLAN
@ 12"o.c. TYP.
THICKNESS. SEAT SCREW HEADS FLUSH WITH PANEL SURFACE, DO NOT OVER DRIVE SCREWS. SCREW FASTENERS TO MAINTAIN
XXXSXXX-XX
XXXSXXX-XX

XXXSXXX-XX
XXXSXXX-XX

¾” DISTANCE FROM ALL BOARD EDGES. SCREW FASTENERS TO MAINTAIN MINIMUM OF 2” DISTANCE FROM BOARD CORNERS ON
ONE SIDE AND 4" DISTANCE ON ANOTHER SIDE OF CORNER AND OFFSET FASTENERS TO AVOID 45 DEGREE FASTENER PLACEMENT
AT BOARD CORNERS. DO NOT OVERDRIVE FASTENERS. FOLLOW MANUFACTURER’S INSTALLATION INSTRUCTIONS.

4. BH DENOTES BOX HEADER MADE OF (2)1000S300-97 + (2) 600T125-97 TRACKS.


OPENING BH-1 DENOTES BOX HEADER MADE OF (3)1000S200-97 + (2) 600T125-97 TRACKS.USE MANUFACTURER'S RECOMMENDATIONS FOR
FASTENERS REQUIREMENTS. ALL MEMBERS TO BE CONTINUOUS. DO NOT SPLICE MEMBERS. THIS APPLIES TO BOTH STUD
OPENING XXXTXXX-XX AND TRACK.

5. DENOTES NEW BEARING LIGHT GAGE WALL FRAMING. SEE SCHEDULE AND TYPICAL DETAILS.
BW
POST HEADER 6. DENOTES MOMENT CONNECTION. SEE TYPICAL DETAIL.
SEAL AND SIGNATURE DATE: 04/15/22
MC
PROJECT No: BGM 22-029
WALL FRAMING SCHEDULE OPENING FRAMING SCHEDULE
DRAWING BY: IK
OPENINGS
WALL LOCATION BW WALL LOCATION H HEADER H HEADER
P (POST) P1 (POST) (4 FT WIDE MAX) (6 FT WIDE MAX) CHK BY: AK

ATTIC - ROOF 600S162-43 @16" O.C. ATTIC FLOOR -ATTIC FLOOR CEILING 600S300-97 DWG No:
2ND FLOOR -ATTIC FLOOR 600S162-54 @16" O.C. 2ND FLOOR -ATTIC FLOOR 600S300-97
(2)600S300-97 (2)362S200-54W/(2)600T125-54 (2)600S200-54W/(2)600T125-54
1ST FLOOR - 2ND FLOOR 600S250-54 @16" O.C. 1ST FLOOR -2ND FLOOR 600S300-97 S-101.00
CELLAR - 1ST FLOOR 600S162-43 @16" O.C. CELLAR - 1ST FLOOR 600S300-97

NOTE:
1. TRACK TOP AND BOTTOM TO BE 600T125-XX AND GAGE TO MATCH WALL STUD.
BGM 22-029 X of X

DOB JOB #
BGM
ENGINEERING, LLC
2123 45TH ROAD, LONG ISLAND CITY, NY 11101
24 CANFIELD DRIVE STAMFORD, CT 06902
TEL: 203.452.9408 and 646.499.0685
2 4 5 8 10 E-MAIL: [email protected]
66'-5"

4 1/2" 15'-0" 15'-5" 19'-5 1/2" 14'-0 1/2" 2'-1"

8 1/2"
P H P
B
MC P1 P1 BW P H P P H P P1 P1 H P P1 BW P1 BH P1 BH
P1 H MC

BRIDGING @8'-0" O.C.

W10x

1000JR200-54 @16" O.C.

14'-8 1/2"
15'-5"

BH

BH

BH

BH

BH

BH
P1 P1 P1 P1 P1 P1

W12x
MC P1 P1 P1 P1 P P
W10x26 P1
D D

1000JR200-54
W10x33 W10x68 W10x19 PROJECT:
BRIDGING @8'-0" O.C.

@16" O.C.
MC

4'-11"
P1 P1
BH
MC
P1
E
2040 EAST 5TH

1000JR200-54 @16" O.C.

1000JR200-54 @16" O.C.

BH
STREET

BH

BH

BH
W10x15

W10x15
16'-2 1/2"

P
W10x

H
BROOKLYN, NY

11'-3 1/2"
P

P1 P1 BH P1
P1 BH P1 BW
11223
MC BW
H P1 P H P P1 BH P1

P P

W10x15
H H

5"
NO. DATE ISSUE/REVISION BY
1 XX/XX/XX PERMIT JB

4 1/2" 15'-0" 15'-5" 7'-5" 12'-0 1/2" 14'-0 1/2"

8 1/2"

2 4 5 7 8 10
DRAWING TITLE:

1 ATTIC FLOOR FRAMING PLAN OVER SECOND FLOOR PLAN NOTES:

S-102 SCALE: 41"=1'-0" 1. ALL DIMENSIONS AND ELEVATIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS AND VERIFIED IN FIELD.

2.
XXX
@16" O.C.
DENOTES ORIENTATION AND DESIGNATION OF FLOOR JOIST DESIGNATION BASED ON MARINOWARE CATALOG.
SEE MANUFACTURER INSTALLATION RECOMMENDATIONS FOR LIGHT GAGE JOIST INSTALLATION REQUIREMENTS. ATTIC FLOOR
#10 TEK SCREW
#10 TEK SCREW
@ 12"o.c. TYP. XXXTXXX-XX
3. DENOTES 34" USG STRUCTURAL PANEL CONCRETE SUBFLOOR. FOR CONNECTION USE CORROSION RESISTANT
SELF-COUNTERSINKING HEAD SCREWS SUCH AS HILTI PWH SD CEMENT BOARD FASTENERS, PART #00372760, OR EQUAL.
FASTENERS TO BE MINIMUM #8 DIAMETER @12" O.C. WITH S-12 SELF-DRILLING "TEK" POINTS. LENGTH = 2 TO 3 TIMES THE BOARD
FRAMING PLAN
@ 12"o.c. TYP.
THICKNESS. SEAT SCREW HEADS FLUSH WITH PANEL SURFACE, DO NOT OVER DRIVE SCREWS. SCREW FASTENERS TO MAINTAIN
XXXSXXX-XX
XXXSXXX-XX

XXXSXXX-XX
XXXSXXX-XX

¾” DISTANCE FROM ALL BOARD EDGES. SCREW FASTENERS TO MAINTAIN MINIMUM OF 2” DISTANCE FROM BOARD CORNERS ON
ONE SIDE AND 4" DISTANCE ON ANOTHER SIDE OF CORNER AND OFFSET FASTENERS TO AVOID 45 DEGREE FASTENER PLACEMENT
AT BOARD CORNERS. DO NOT OVERDRIVE FASTENERS. FOLLOW MANUFACTURER’S INSTALLATION INSTRUCTIONS.

4. BH DENOTES BOX HEADER MADE OF (2)1000S300-97 + (2) 600T125-97 TRACKS.


OPENING BH-1 DENOTES BOX HEADER MADE OF (3)1000S200-97 + (2) 600T125-97 TRACKS.USE MANUFACTURER'S RECOMMENDATIONS FOR
FASTENERS REQUIREMENTS. ALL MEMBERS TO BE CONTINUOUS. DO NOT SPLICE MEMBERS. THIS APPLIES TO BOTH STUD
OPENING XXXTXXX-XX AND TRACK.

5. DENOTES NEW BEARING LIGHT GAGE WALL FRAMING. SEE SCHEDULE AND TYPICAL DETAILS.
BW
POST HEADER 6. DENOTES MOMENT CONNECTION. SEE TYPICAL DETAIL.
SEAL AND SIGNATURE DATE: 04/15/22
MC
PROJECT No: BGM 22-029
WALL FRAMING SCHEDULE OPENING FRAMING SCHEDULE
DRAWING BY: IK
OPENINGS
WALL LOCATION BW WALL LOCATION H HEADER H HEADER
P (POST) P1 (POST) (4 FT WIDE MAX) (6 FT WIDE MAX) CHK BY: AK

ATTIC - ROOF 600S162-43 @16" O.C. ATTIC FLOOR -ATTIC FLOOR CEILING 600S300-97 DWG No:
2ND FLOOR -ATTIC FLOOR 600S162-54 @16" O.C. 2ND FLOOR -ATTIC FLOOR 600S300-97
(2)600S300-97 (2)362S200-54W/(2)600T125-54 (2)600S200-54W/(2)600T125-54
1ST FLOOR - 2ND FLOOR 600S250-54 @16" O.C. 1ST FLOOR -2ND FLOOR 600S300-97 S-102.00
CELLAR - 1ST FLOOR 600S162-43 @16" O.C. CELLAR - 1ST FLOOR 600S300-97

NOTE:
1. TRACK TOP AND BOTTOM TO BE 600T125-XX AND GAGE TO MATCH WALL STUD.
BGM 22-029 X of X

DOB JOB #
BGM
ENGINEERING, LLC
2123 45TH ROAD, LONG ISLAND CITY, NY 11101
24 CANFIELD DRIVE STAMFORD, CT 06902
TEL: 203.452.9408 and 646.499.0685
E-MAIL: [email protected]

P H P P H P1 P HP P1

1000JR200-54 @16" O.C.


P1 P1

BH-1

BH-1
P1
P1 P1 P1
P1
P1

BRIDGING @8'-0" O.C.

H BH H

1000JR200-54
P1
PROJECT:

BH
BH P1 P1 P1 P1 P1 P P

@16" O.C.
P1
P1

P1 P1 P1 P1

P1
P1
2040 EAST 5TH

1000JR200-54 @16" O.C.

BH-1

BH-1
STREET

BH
BH
BROOKLYN, NY
P H P1
11223
P1
P1 H P P H P P H P

5"
7'-5" NO. DATE ISSUE/REVISION BY
1 XX/XX/XX PERMIT JB
5 7

DRAWING TITLE:

1 ATTIC CEILING FRAMING PLAN NOTES:

S-103 SCALE: 41"=1'-0" 1. ALL DIMENSIONS AND ELEVATIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS AND VERIFIED IN FIELD.

2.
XXX
@16" O.C.
DENOTES ORIENTATION AND DESIGNATION OF FLOOR JOIST DESIGNATION BASED ON MARINOWARE CATALOG.
SEE MANUFACTURER INSTALLATION RECOMMENDATIONS FOR LIGHT GAGE JOIST INSTALLATION REQUIREMENTS. ATTIC CEILING
#10 TEK SCREW
#10 TEK SCREW
@ 12"o.c. TYP. XXXTXXX-XX
3. DENOTES 34" USG STRUCTURAL PANEL CONCRETE SUBFLOOR. FOR CONNECTION USE CORROSION RESISTANT
SELF-COUNTERSINKING HEAD SCREWS SUCH AS HILTI PWH SD CEMENT BOARD FASTENERS, PART #00372760, OR EQUAL.
FASTENERS TO BE MINIMUM #8 DIAMETER @12" O.C. WITH S-12 SELF-DRILLING "TEK" POINTS. LENGTH = 2 TO 3 TIMES THE BOARD
FRAMING PLAN
@ 12"o.c. TYP.
THICKNESS. SEAT SCREW HEADS FLUSH WITH PANEL SURFACE, DO NOT OVER DRIVE SCREWS. SCREW FASTENERS TO MAINTAIN
XXXSXXX-XX
XXXSXXX-XX

XXXSXXX-XX
XXXSXXX-XX

¾” DISTANCE FROM ALL BOARD EDGES. SCREW FASTENERS TO MAINTAIN MINIMUM OF 2” DISTANCE FROM BOARD CORNERS ON
ONE SIDE AND 4" DISTANCE ON ANOTHER SIDE OF CORNER AND OFFSET FASTENERS TO AVOID 45 DEGREE FASTENER PLACEMENT
AT BOARD CORNERS. DO NOT OVERDRIVE FASTENERS. FOLLOW MANUFACTURER’S INSTALLATION INSTRUCTIONS.

4. BH DENOTES BOX HEADER MADE OF (2)1000S300-97 + (2) 600T125-97 TRACKS.


OPENING BH-1 DENOTES BOX HEADER MADE OF (3)1000S200-97 + (2) 600T125-97 TRACKS.USE MANUFACTURER'S RECOMMENDATIONS FOR
FASTENERS REQUIREMENTS. ALL MEMBERS TO BE CONTINUOUS. DO NOT SPLICE MEMBERS. THIS APPLIES TO BOTH STUD
OPENING XXXTXXX-XX AND TRACK.

5. DENOTES NEW BEARING LIGHT GAGE WALL FRAMING. SEE SCHEDULE AND TYPICAL DETAILS.
BW
POST HEADER 6. DENOTES MOMENT CONNECTION. SEE TYPICAL DETAIL.
SEAL AND SIGNATURE DATE: 04/15/22
MC
PROJECT No: BGM 22-029
WALL FRAMING SCHEDULE OPENING FRAMING SCHEDULE
DRAWING BY: IK
OPENINGS
WALL LOCATION BW WALL LOCATION H HEADER H HEADER
P (POST) P1 (POST) (4 FT WIDE MAX) (6 FT WIDE MAX) CHK BY: AK

ATTIC - ROOF 600S162-43 @16" O.C. ATTIC FLOOR -ATTIC FLOOR CEILING 600S300-97 DWG No:
2ND FLOOR -ATTIC FLOOR 600S162-54 @16" O.C. 2ND FLOOR -ATTIC FLOOR 600S300-97
(2)600S300-97 (2)362S200-54W/(2)600T125-54 (2)600S200-54W/(2)600T125-54
1ST FLOOR - 2ND FLOOR 600S250-54 @16" O.C. 1ST FLOOR -2ND FLOOR 600S300-97 S-103.00
CELLAR - 1ST FLOOR 600S162-43 @16" O.C. CELLAR - 1ST FLOOR 600S300-97

NOTE:
1. TRACK TOP AND BOTTOM TO BE 600T125-XX AND GAGE TO MATCH WALL STUD.
BGM 22-029 X of X

DOB JOB #
BGM
ENGINEERING, LLC
2123 45TH ROAD, LONG ISLAND CITY, NY 11101
24 CANFIELD DRIVE STAMFORD, CT 06902
TEL: 203.452.9408 and 646.499.0685
E-MAIL: [email protected]

2x8 @16" O.C.


(2

VL
P1

)1 4

"L
3 "x

RAFTER

17
8 P1

11

x1
P1 P1

7
3

4"
"L

)1
VL

(2
(2) 2x12

(2)134"x1178" LVL

(2)134"x1178" LVL
P1 P1 P1
(2)134"x1178" LVL (2)134"x1178" LVL

2x12 @16" O.C.


(3
)1 4
3 "x

(2)134"x1178" LVL

(2)134"x1178" LVL
11
2x8 @16" O.C. 2x8 @16" O.C.

7 "

RAFTER
8

(2) 2x12
RAFTER RAFTER

LVL

2x12 @16" O.C.


(2

L
LV
3

)1 4
BUILT UP

RAFTER
4'-2" 12'-0" 10'-9" 10'-9" 5'-4"

17
8"
"x
2x10 @16" O.C.

11

x1
7 "
8

)1 3
4"
LV

(2
L
P1 P1 P1 P1 P1 P1 P1
2x12 @16" O.C.
(3)134"x14" LVL (3)134"x14" LVL (3)134"x14" LVL (3)134"x14" LVL (3)134"x14" LVL RAFTER

BUILT UP
2x10 @16" O.C.

(3)134"x14" LVL

(3)134"x14" LVL
2x12 @16" O.C.
2x12 @16" O.C.

(3
RAFTER

)1
RAFTER 4 PROJECT:

"x3
(3

11
P1 (3)134"x14" LVL (3)134"x14" LVL

7
)1 4
3 "x

8
"L
VL
(3)134"x14" LVL

11
7 "
P1 P1

8
(3)134"x14" (3)134"x14" (3)134"x14"

L
LVL LVL LVL

VL
P1
P1 P1 P1 P1

2'-0" 13'-0" 11'-7 1/2" 3'-5" 7'-7 1/2" 5'-4"


P1 P1
2040 EAST 5TH

L VL

(3
2x12 @16" O.C.

17
8"

)1 4
STREET

3 "x
RAFTER

x1

(2)134"x1178" LVL
)1 3

11
4"

7
(3

8
"L
)1 4
(2

3 "x

VL
L
LV BROOKLYN, NY

2x12 @16" O.C.

11
(2)134"x1178" LVL

(2)134"x1178" LVL

7
17
8"

8
"L
2x8 @16" O.C.

(3
x1

2x12 @16" O.C.

VL
)1
4

3
RAFTER
)1 3
4"

"x
RAFTER

11
(3

11223

7
P1 P1

8
"L
RAFTER

VL
P1
(2)134"x1178" LVL (2)134"x1178" LVL

L
LV
P1

(2) 2x12
7

8"
P1

1
P1

x1
P1

3
4"
(2)134"x1178" LVL
)1
(2
(2) 2x12

NO. DATE ISSUE/REVISION BY


1 XX/XX/XX PERMIT JB

DRAWING TITLE:

1 ROOF FRAMING PLAN


S-104 SCALE: 41"=1'-0"

ROOF
FRAMING PLAN

SEAL AND SIGNATURE DATE: 04/15/22

PROJECT No: BGM 22-029

DRAWING BY: IK

CHK BY: AK

DWG No:

S-104.00
BGM 22-029 X of X

DOB JOB #
COLUMN
COLUMN SCHEDULE BGM
ENGINEERING, LLC
A1 A2 A 5.1, A 7.1 A10 C1 C9 D2 D4 D5 D6 D8 E10 F5 F7 G1 G2 G3 2123 45TH ROAD, LONG ISLAND CITY, NY 11101
FLOOR FOR COLUMN,
ANCHOR BOLT & 24 CANFIELD DRIVE STAMFORD, CT 06902
BASE PLATE SIZE, TEL: 203.452.9408 and 646.499.0685
SEE COLUMN SCHEDULE E-MAIL: [email protected]
ROOF STIFFENER
EL. 35'-0" B
HARDENED NUT
121" 121"
AT PLATE PLATE WASHER

LEVELING
TYP TYP 1/4"

PLATE
ATTIC FLOOR WASHERS ONLY

4"
1
TYP
HSS6x6x5/8
EL. 24'-5" FOOTING, PIER,

121"

10"
20K 20K 20K 20K 20K 20K 20K 20K FOUNDATION MAT

EQ
OR FOUNDATION
WALL

N
SECOND FLOOR

HSS6x6x5x8

HSS8x6x5x8

HSS8x6x5x8
HSS8x6x5/8

HSS5x5x3/8

HSS6x6x3/8

HSS8x6x5/8

EQ

EMBEDMENT
CL OF COL

HSS8x6x5x8

HSS5x5x3x8

HSS5x5x3x8
EL. 14'-1"
20K 20K 20K 20K 20K (20K) (20K) (20K) 20K 20K 20K 20K (20K)

GROUT
40K 40K 40K 40K CL OF COL

BED
134"
FIRST FLOOR
5/16"

HSS6x6x3/8

HSS5x5x1/2

HSS6x6x5/8

HSS6x6x3/8

HSS6x6x5/8

HSS6x6x3/8
EL. 1'-9"
20K (20K) (20K) 20K (20K) 20K TYPE "1"
60K 60K 60K
NOTE:
CELLAR
SEE COLUMN SCHEDULE FOR INFORMATION NOT SHOWN
EL. -10'-3"

BASE PLATE
PL 1" PL 1" PL 1" PL 1" PL 1" PL 1" PL 1" PL 1" PL 1" PL 1" PL 1" PL 1" PL 1" PL 1"
COLUMN BASE PLATE DETAILS TYPICAL COLUMN BEARING DETAIL
txN xB 10"x10" 10"x10" 10"x10" 10"x10" 10"x10" 10"x10" 10"x10" 10"x10" 10"x10" 10"x10" 10"x10" 10"x10" 10"x10" 10"x10" SCALE: N.T.S.
SCALE: N.T.S.
EMBEDMENT 18" 18" 18" 18" 18" 18" 18" 18" 18" 18" 18" 18" 18" 18"

BASEPLATE 1 1 1 1 1 1 1 1 1 1 1 1 1 1
TYPE
STEEL COLUMN
ANCHOR BOLTS
(4) 1"Ø (4) 1"Ø (4) 1"Ø (4) 1"Ø (4) 1"Ø (4) 1"Ø (4) 1"Ø (4) 1"Ø (4) 1"Ø (4) 1"Ø (4) 1"Ø (4) 1"Ø (4) 1"Ø (4) 1"Ø
QANTITY
MATERIAL F1554 F1554 F1554 F1554 F1554 F1554 F1554 F1554 F1554 F1554 F1554 F1554 F1554 F1554
GR55 GR55 GR55 GR55 GR55 GR55 GR55 GR55 GR55 GR55 GR55 GR55 GR55 GR55 PL 34" UPPER MOMENT PLATE PROJECT:

W/(8) 34"Ø A325


NOTES: PROVIDE SHIM
1. BOTTOM BASE PLATE ELEVATION ALL COLUMNS SHALL BE COORDINATED
BETWEEN TOP OF BEAM'S
WITH CONCRETE PIER TOP ELEVATION. FLANGE AND BOTTOM
2. IF REQUIRED BY CONSTRUCTION CONSTRAINT OTHER SPLICE CONNECTIONS SHALL BE PLACED AT
48" DISTANCE FROM THE FLOOR FRAMING. SPLICE CONNECTION DESIGN SHALL FOLLOW AISC RECOMMENDATIONS.
OF MOMENT PLATE FOR
TIGHT CONNECTION
2040 EAST 5TH
3.
1
PROVIDE STIFFENER PLATES PL 2" AT BOTH SIDES OF TRANSFER BEAM FLANGE.
STIFFENER PLATE SHALL BE ALIGNED WITH CENTER LINE OF COLUMN ABOVE.
A A STREET
4. ALL T.O.S. ELEVATIONS TO BE COORDINATED WITH ARCHITECTURAL DRAWINGS BROOKLYN, NY
STEEL BEAM
SEE PLAN 11223

A A
NO. DATE ISSUE/REVISION BY
PL 34" LOWER MOMENT PLATE 1 XX/XX/XX PERMIT JB
3-SIDES, W/(8) 34"Ø A325
WIDE FLANGE OR HSS
NOTE 1, TYP.

NOTE 1
221" 1" MIN. THICKNESS BASE
STEEL COLUMN
(TYP). PL. w/ (4) 7 8"Φ A325
BOLTS (MIN)
BRACING BEAM SHOWN ON PLAN
STEEL COLUMN
MAY FRAME TO EITHER STIFFENER
WITH FULL DEPTH SHEAR
CONNECTION UNLESS BEAM IS
SHOWN ON GRID OR IS LABELED STIFF. PL. (EA SIDE)
AS 'CENTERED' IN WHICH CASE THICKNESS EQUAL TO
BEAM FRAMES TO ADDED COLUMN FLANGE ABOVE
DRAWING TITLE:
STIFFENER IN COLUMN STEEL BEAM STEEL COLUMN
CENTERLINE. SEE PLAN ABOVE & BELOW

WIDE FLANGE COLUMN WITH WEB PERPENDICULAR TO


3-SIDES, BEAM WEB, OR HSS WITH PERPENDICULAR DIMENSION
NOTE 1, TYP. WIDER THAN BEAM FLANGE.
NOTE 1 COLUMN
STIFFENER PLATE (EA SIDE)
PL 34" UPPER
MOMENT PLATE
SCHEDULE
NOTE 2
FITTED TO BEAM AND TO BEARING PL. AND COLUMN BASE PLATE
W/(8) 34"Ø A325
& DETAILS
NOTE:
ALL CONNECTIONS ARE FOR SCHEMATIC PURPOSED ONLY.
ALL CONNECTIONS MUST BE DESIGNED BY A LICENSED ENGINEER
PROFESSIONAL IN THE STATE OF NEW YORK
BEARING PL. MATCHING NOMINAL THICKNESS OF SUPPORTING
BEAM, AND MATCHING FOOT PRINT OF SUPPORTING COLUMN SECTION A-A
BASE PLATE 1" MIN. THICKNESS BASE PL. w/ (4) 7 8"Ø A325 BOLTS (MIN)
NOTES:
1. MINIMUM WELD SIZE PER TABLE J2.4 OF AISC-LRFD SPECIFICATION. SEAL AND SIGNATURE DATE: 04/15/22
2. CJP BETWEEN BEARING PLATE AND SUPPORTING BEAM.
3. FULLY TENSION ALL BOLTS. PROJECT No: BGM 22-029

DRAWING BY: IK

CHK BY: AK

DWG No:

COLUMN BASE TO STEEL SUPPORT ONE WAY MOMENT CONNECTION DETAIL S-200.00
SCALE: N.T.S.
SCALE: N.T.S.
BGM 22-029 X of X

DOB JOB #
TRACK (SAME AS HEADER)

BGM

1/2" (MAX)
600T200-54 FASTEN W/ (8) # 10TEK
FASTEN U-CHANNEL
SCREWS INTO JAMB AND HEADER
TO CLIP USING (2) #10 SPAZZER 5400 BRIDGING BAR BY DIETRICH
REFER TO SECTIONS TEK SCREWS
FOR FASTENERS TO 1-1/2" x 1-1/2" x 16-GAGE, HEADER ATTACHMENT ENGINEERING, LLC
STRUCTURE ABOVE CLIP ANGLE FASTENED TO STUD
C SOLID BLOCKING IN 2123 45TH ROAD, LONG ISLAND CITY, NY 11101
L OF STUD WF-BEAM W/ (2) #10 TEK SCREWS.
2" ANGLE LENGTH SHALL NOT FIRST 24 CANFIELD DRIVE STAMFORD, CT 06902
(REFER TO S-DWGS)
) BE LESS THAN STUD DEPTH, AND LAST BAY AND TEL: 203.452.9408 and 646.499.0685
M IN
4"( (2) #10-16 TEK SCREWS MINUS 1/2" AT 10-FEET o.c. MIN. E-MAIL: [email protected]
END OF TYP. EACH STUD 6" METAL STUD 2" UTILITY CLIP ANGLES
CRIPPLE STUDS
SLIP TRACK (BY DESIGN)
METAL STUD (SEE PLAN) 6" METAL STUD ATTACH TOP &
6" SLP-TRK (BDTK) 112" x 16GA. U-CHANNEL BOTTOM TRACK
SOLID BLOCKING IN FIRST AND
BY DIETRICH USING: (2)#10-16
LAST BAY AND AT 10-FEET o.c. MIN.
SCREWS @ 24"o.c.
FASTEN SLOTTED DEFLECTION
CONT. 2" x 20 GAGE COLD-ROLLED BRIDGING W/ CLIP ANGLE BRIDGING BAR DETAIL (ALTERNATE)

12" (MAX)
TRACK TO WF-BEAM CONT. 2" x 20 GAGE
STRAP BRIDGING BOTH SIDES #10 TEK SCREW
USING (2) HILTI X-U P.A.F. STRAP BRIDGING BOTH SIDES
EACH SIDE TYP.
@ 16"o.c. (EACH STUD) METAL STUD (1)#10-16 SCREW
MAINTAIN A MINIMUM DEFLECTION TYP. EACH FLANGE
6" METAL STUD (2) #10-16 TEK SCREWS TYP. EACH STUD
GAP OF 5 8" BETWEEN TOP NOTE: ENSURE PUNCH OUT ALIGNMENT FOR LATERAL BRACING / BRIDGING. LATERAL BRACING / BRIDGING
NOTE: SLOTTED DEFLECTION TRACK CAN BE USED AS ALTERNATE - JAMB STUDS
OF STUD AND TRACK TYP. SHALL BE SPACED AT 48-INCHES ON-CENTER MAX. FAILURE TO INSTALL BRACING MAY COMPROMISE
SEE DETAIL ABOVE (CONTRACTORS OPTION). (BY DESIGN)
THE STRUCTURAL INTEGRITY OF THE FRAMING. THROUGH WALL BRIDGING IS ONLY GOOD FOR STUDS
(2) UN-PUNCHED STUDS.
THAT ARE 6" OR SMALLER. FOR STUDS THAT ARE 8" OR LARGER REFER TO BLOCK AND STRAP DETAILS ABOVE.
(BY DESIGN)

TYPICAL DEFLECTION DEFLECTION TRACK TYPICAL LATERAL TYPICAL BLOCK


TRACK DETAIL CONNECTION BRIDGING DETAIL AND STRAP DETAILS BOX HEADER CONNECTION

ClarkDietrich BUILDING SYSTEM ClarkDietrich BUILDING SYSTEM


JAMB, SIZE AND
ClarkDietrich BUILDING SYSTEM JAMB, SIZE AND VIEW
INSTALL STUDS GAGE AS REQUIRED GAGE AS REQUIRED EV.
WITH SAME 6" METAL STUD SUPPORT CLIP W/ EL
DIMENSION (10" MIN.) SCREWS AS REQUIRED
FOR BRIDGING 6" TRACK TYP. TOP 6-INCH STUD PIECE,
12" LONG W/ (4) #10-16 ClarkDietrich SCREWS AS REQUIRED SCREWS AS REQUIRED
ALIGNMENT. AND BOTTOM OF WALL
SCREWS EACH SIDE OF SPLICE BUILDING SYSTEM ClarkDietrich BUILDING SYSTEM PROJECT:
PROVIDE BRIDGING SCREWS AS REQUIRED SILL, SIZE AND
SILL, SIZE AND
@ 4'-0" o.c. TYP. GAGE AS REQUIRED ClarkDietrich BUILDING SYSTEMS
GAGE AS REQUIRED
(2) HILTI TYPE X-U FTC-500 WITH (3) PROPRIETARY
POWDER ACTUATED (1) #10-16 SCREW SCREWS AT TOP SCORELINE
FASTENERS EACH ClarkDietrich BUILDING SYSTEM ENGINEER OF RECORD:
PER STUD FLANGE MIN. TO STUD AND ATTACHED TO
STUD STUD PIECE, SIZE AND VERIFY GAP DEPTH.
CONCRETE AS REQ'D BY DESIGN
GAGE AS REQUIRED
6" METAL TRACK
ClarkDietrich BUILDING SYSTEMS TYPICAL STUD 2040 EAST 5TH
STREET

DEFLECTION
TYPICAL STUD TYPICAL TRACK TYPICAL JAMB BROOKLYN, NY

ALLOW FOR
1/2" GAP TO
SCREW EDGE
TYPICAL

VERTICAL
DISTANCE
3/4" MIN.
WALL STUD
ELEV. VIEW
BASE DETAIL SPLICE CONNECTION AND SILL DETAIL ClarkDietrich BUILDING SYSTEMS
S-SERIES CLIP WITH SCREWS 11223
TO STUD AS REQ'D
BY DESIGN AND
FASTENED TO CONCRETE
AS REQ'D BY DESIGN

SSMA STUD SECTION CONCRETE SLAB BY OTHERS


TYPICAL TRACK W/(1)
#10 TEK SCREW @ #10 TEK SCREW @ #10 TEK SCREW @ #10 TEK SCREW @ #10-16 SCREW PER STUD FLANGE
12"o.c. TYP. 12"o.c. TYP. 12"o.c. TYP. 12"o.c. TYP. MEMBER DEPTH: 600 S 162-54
(EXAMPLE: 6" = 600 x 1100 INCHES) MATERIAL THICKNESS: NO. DATE ISSUE/REVISION BY
ALL MEMBER DEPTHS
(2)600T125-43 (2)600T125-54 (2)600T125-68 (2)600T200-97 (EXAMPLE: 0.054" = 54 MILS; 1 MIL = 1100"). MATERIAL THICKNESS IS THE MINIMUM 1 XX/XX/XX PERMIT JB
ARE TAKEN IN 1100 INCHES. BASE METAL THICKNESS IN MILS.
FOR ALL "T" SECTIONS,
MINIMUM BASE METAL THICKNESS REPRESENTS 95% OF THE DESIGN THICKNESS
MEMBER DEPTH IS
TYPICAL JAMB CONNECTION
600S162-43

600S162-43

600S162-54

600S162-54

600S162-68

600S162-68

600S162-68

600S162-68

INSIDE-TO-INSIDE DIMENSION.

STYLE:
(EXAMPLE: STUD OR JOIST SECTION = "S").
TOP AND BOTTOM
THE FOUR ALPHA CHARACTERS FLANGE WIDTH:
OPENING OPENING OPENING OPENING
UTILIZED BY THE DESIGNATOR SYSTEM ARE:
600T125-43 600T125-54 600T125-68 600T200-97 (EXAMPLE: 15 8" = 1.625" = 162 x 1100 INCHES)
S = STUD OR JOIST SECTION
ALL FLANGE WIDTHS ARE TAKEN IN 1100".
T = TRACK SECTION
H1 H2 H3 H4 U = CHANNEL SECTION NON LOAD BEARING - COLD FORMED FRAMING NOTES:
F = FURRING CHANNEL SECTION
#10 TEK SCREW @ #10 TEK SCREW @ 1. ALL PRODUCT SHALL MEET THE REQUIREMENTS OF THE CURRENT EDITION OF ASTM
12"o.c. TYP. 12"o.c. TYP. A 1003M/15 "SPECIFICATION FOR COLD-FORMED FRAMING MEMBERS".

600T125-43 600T125-54 600T125-68 600T125-54 600T125-68 2. ALL COLD-FORMED STEEL SHALL CONFIRM TO SPECIFICATIONS ASTM A 1003M/15. DRAWING TITLE:
OPENING OPENING OPENING OPENING OPENING MINIMUM STEEL YIELD FY(MIN) SHALL BE, AS FOLLOWS:
600S162-54 600S162-68
600T125-54 600T125-68 MINIMUM STEEL YIELD FY(MIN)=33 KSI FOR 18 AND 16 GAUGE STUDS AND FLOOR
JOISTS. MINIMUM STEEL YIELD FY(MIN)=50 KSI FOR 14 GAUGE STUDS AND FLOOR
S1 S2 S3 S4 S5 JOISTS.

3. ALL DETAILS OF THE COLD FORMED FRAMING CONNECTIONS SHOWN ARE TYPICAL FOR
THIS INSTALLATION HOWEVER IT IS CONTRACTOR RESPONSIBILITY TO DESIGN LIGHT
TYPICAL
FRAMING CONNECTIONS AND TO PROVIDE SHOP DRAWINGS FOR EOR REVIEW.
#10 TEK SCREW @
12"o.c. TYP.
#10 TEK SCREW @
12"o.c. TYP.
#10 TEK SCREW @
12"o.c. TYP.
#10 TEK SCREW @
12"o.c. TYP.
WALL AND OPENING FRAMING SCHEDULE 4. ALL FIELD CUTTING OF STUDS MUST BE DONE BY SAWING OR SHEARING. TORCH
INFILL
CUTTING OF COLD-FORMED MEMBERS IS UNACCEPTABLE.

LIGHT-GAGE
600S162-54
600S162-43

600S162-68

600S162-68

600S300-68

600S300-68

600S300-68
600S162-54

600T125-68
600T125-68
600T125-68

600T125-68
600T125-68

REGULAR L/600
600T125-54
600T125-43
600S162-43

5. NOTCHING OR COPING IS NOT PERMITTED UNLESS STATED OR SHOWN WITHIN SHOP


STUD SPAN 10 FT MAX 12 FT MAX 14 FT MAX 10 FT MAX 12 FT MAX 14 FT MAX DRAWINGS.
WALL
BOTT TRACK
600S162-43 @16" O.C.
600T125-43
600S162-54 @16" O.C.
600T125-54
600S162-68 @16" O.C.
600T125-68
800S162-43 @16" O.C.
800T162-43
800S162-54 @16" O.C.
800T162-54
800S162-54 @16" O.C.
800T162-54
6. ENDS OF STUDS SHALL SEAT FIRMLY WITHIN TRACK WITH THE EXCEPTION OF
DEFLECTION TRACK. TRACK MUST HAVE FULL BEARING ON STRUCTURE.
DETAILS
OPENING OPENING OPENING OPENING OPENINGS
7. SPLICING OF WALL STUDS IS NOT PERMITTED UNLESS OTHERWISE STATED OR SHOWN
4 FT WIDE MAX 4 FT WIDE MAX WITHIN SHOP DRAWINGS.
J1 J2 J3 J4
HEADER H1 H1
NOTES: 8. ENSURE PUNCHOUT ALIGNMENT FOR LATERAL BRACING/BRIDGING. LATERAL BRACING/
SILL S1 S1 BRIDGING SHALL BE SPACED AT 48-INCHES ON-CENTER MAXIMUM. LATERAL BRACING/
1. ALL HEADER, SILL AND JAMB MATERIAL TO BE UN-PUNCHED TRACK AND STUD. BRIDGING SHALL BE INSTALLED AT THE TIME THE WALL IS ERECTED. FAILURE TO
2. ALL HEADER, SILL AND JAMB MATERIAL MUST BE CONTINUOUS. DO NOT SPLICE MEMBERS JAMB J1 J2 INSTALL BRACING MAY COMPROMISE THE STRUCTURAL INTEGRITY OF THE FRAMING.
TOGETHER INCLUDING TRACKS. OPENINGS
9. JOIST OR ROOF MEMBERS MUST BEAR DIRECTLY OVER WALL STUDS. OTHERWISE,
8 FT WIDE MAX 8 FT WIDE MAX A STRUCTURAL MEMBER (BY OTHERS) IS REQUIRED ON TOP OF RUNNER TRACK FOR SEAL AND SIGNATURE DATE: 04/15/22
PROPER BEARING AND ANCHORAGE. NO NOTCHING OR COPING OF JOISTS OR RAFTERS
HEADER H2 H2
IS ALLOWED.
PROJECT No: BGM 22-029
SILL S2 S3
10. ALL HEADERS / BUILT-UP BEAMS ARE TO BE CONSTRUCTED WITH UNPUNCHED
JAMB J2 J3 MATERIAL ONLY. SPLICING OF HEADERS IS NOT PERMITTED. DRAWING BY: IK
OPENINGS
11. SCREWS: MAINTAIN A MINIMUM OF 3/4" CLEARANCE FROM ALL EDGES OF STEEL CHK BY: AK
12 FT WIDE MAX 12 FT WIDE MAX MEMBERS AND ¾” MINIMUM FROM ON CENTER SPACING BETWEEN ADJACENT
HEADER H3 H4 SCREWS. DWG No:

SILL S4 S5
JAMB J3 J4
S-300.00
BGM 22-029 X of X

DOB JOB #
1 1/2 "x12 "x16ga., 50ksi
SUPPORT CLIP, 5" LONG
WITH (2) #10-16 SCREWS
PER LEG
STUD
STUD
2 SCREWS PER ROW
EVERY 24" O.C.
BGM
ENGINEERING, LLC
2123 45TH ROAD, LONG ISLAND CITY, NY 11101
24 CANFIELD DRIVE STAMFORD, CT 06902
2" OR 4"x16 GA. TEL: 203.452.9408 and 646.499.0685
CONTINUOUS FLAT STRAP
E-MAIL: [email protected]
DRYWALL SCREWS AS AT EACH SIDE
REQUIRED FOR DESIGN (3) #10-16 SCREWS
AT EACH SIDE TO
ClarkDietrich BUILDING SYSTEMS EACH SOLID BLOCK
SPAZZER TM 9200

TRACK

SECTION ATTACH TRACK TO EACH STUD


FLANGE
(1) #10-16 SCREW AT EACH
SIDE AT EACH
ATTACH AT EACH STUD
ClarkDietrich INTERSECTION , SEE NOTE 2
BUILDING SYSTEMS
TYPICAL STUD ATTACH TRACK TO
EACH STUD FLANGE TRACK
ClarkDietrich BUILDING SYSTEMS
SPAZZER TM 9200 ATTACH AT EACH STUD
2" LAP AT PUNCHOUT BRIDGING/SPACER BAR INSTALL SOLID BLOCK FIT SNUG IN FIRST
PER MANUFACTURER'S AND LAST 2 BAYS, REPEAT IN 1
INSTRUCTIONS. BAY AT EVERY 8'-0" O.C.
STUDS IN PLACE BACK-TO-BACK-STUDS
DRYWALL SCREWS AS 1 1/2"x4"x16ga., 50ksi
REQUIRED FOR DESIGN SUPPORT CLIP, 5" LONG WITH
(2) #10-16 SCREWS PER LEG

RIM TRACK TO MATCH FLOOR JOIST


GAUGE ATTACHED TO EXIST
MASONRY WALL (AT FLOOR JOIST)
CONT. TRACK PROJECT:
NOTE: WITH HILTI HLC SLEEVE ANCHOR 21"Ø
1. USE 1-1/2" x 4" x 16ga., 50ksi SUPPORT CLIP, 5" LONG WITH (2) #10-16 SCREWS @16" O.C. MIN. EMBED. 1.5"
PER LEG AT BRIDGING FOR DOUBLE STUDS.
2. TWO (2) SCREWS EACH SIDE, AXIALY LOADED WALL ONE (1) SCREW EACH FASTEN WEB STIFFENER W/ (3) #10-16 FASTEN WEB STIFFENER W/
SIDE, ACCEPTABLE IF NONAXIAL LOADED WALL (CURTAIN WALL). TEK SCREWS AT EACH JOIST (3) #10-16 TEK SCREWS AT
EACH JOIST

STUD JOIST JOIST 2040 EAST 5TH


BLOCK AND STRAP BRIDGING REQUIRED
ON ALL LOAD BEARING WALLS @ 4'-0" ANCHOR RIM JOIST TO WALL W/ #10-16
TEK SCREWS
STREET
BUILT-UP POST
ANCHOR RIM JOIST TO
WALL W/ #10-16 TEK SCREWS BROOKLYN, NY
LAP JOINT, COPE FLANGES
TRACK 11223
ATTACH WTIH OF TRACK AS REQUIRED CONT. JAMB END BEARING WALL
SCREWS AT AT CORNER SEE PLAN
SILL END BEARING WALL
CORNER ATTACH EACH SIDE
(1) #10-16 SCREW STUD PIECE FOR SILL ATTACHMENT. SEE PLAN
AT EACH STUD FASTEN TO SILL AND JAMB USING #10 ALIGN JOIST WITH
TEK SCREWS. (ALTERNATIVE USE WALL STUD ALIGN JOIST WITH
S685 w/ (4) #10 TEK SCREWS EA. LEG.) WALL STUD

NO. DATE ISSUE/REVISION BY


ATTACH TRACK TO NOTE: LOAD BEARING WALL FRAMING ABOVE AND
1 XX/XX/XX PERMIT JB
EACH STUD FLANGE BELOW MUST ALIGN WITH JOISTS OTHER WISE NOTIFY
ENGINEER OF RECORD
CRIPPLE TRACK
STUDS
NOTE: FASTEN BUILT-UP MEMBER TOGETHER AT 12" O.C. MAX

EXTERIOR CORNER TIE TYPICAL SILL TO JAMB CONNECTION BUILD-UP POST RIM JOIST DETAIL
TOP TRACK

ATTACH TOP & RUNNER TRACK


BOTTOM TRACK (BY DESIGN) TRACK
USING: (2)#10-16 STUD
DRAWING TITLE:
SCREWS @ 24"o.c.
ATTACH 24' O.C. MAX.
(2) UNPUNCHED STUDS. HEADER ATTACHMENT
(BY DESIGN)
BUILD-UP
HEADER (BY
DESIGN)
TYPICAL
UTILITY CLIP ANGLES,
(BY DESIGN) CRIPPLE STUDS UTILITY CLIP ANGLES
(BY DESIGN)
STRUCTURAL
JAMB STUDS ATTACH TOP &
(BY DESIGN) BOTTOM TRACK
USING: (2)#10-16
LIGHT-GAGE
SCREWS @ 24"o.c.
CRIPPLE STUDS.
(BY DESIGN)
DETAILS
(1)#10-16 SCREW JAMB ASSEMBLY
RUNNER TRACK (1)#10-16 SCREW
TYP. EACH FLANGE
(BY DESIGN) TYP. EACH FLANGE
HEAD TRACK.
(BY DESIGN) JAMB STUDS
(BY DESIGN)
HEADER ATTACHMENT TRACK
ATTACH TRACK TO
(2) UNPUNCHED STUDS. EACH STUD
(BY DESIGN) FLANGE
NOTE: FASTEN BUILT-UP MEMBER TOGETHER AT 12" O.C. MAX

BOX HEADER CONNECTION THREE STUD CORNER BEARING HEADER SEAL AND SIGNATURE DATE: 04/15/22

PROJECT No: BGM 22-029

DRAWING BY: IK

CHK BY: AK
NOTE: DWG No:
ALL COLD FORM SHOWN ON STRUCTURAL DRAWINGS IS FOR CONCEPT ONLY. SUBMIT SHOP
DRAWINGS, CALCULATIONS, AND ALL PROPOSED PRODUCT DATA FOR REVIEW INCLUDING S-301.00
STUD AND TRACK SIZES AND MANUFACTURERS AS WELL AS ACCESSORIES, FRAMING
CONNECTIONS, FASTENERS, AND COATINGS. SHOP DRAWINGS AND CALCULATIONS SHOULD BE
BGM 22-029 X of X
SIGNED, SEALED AND PREPARED BY A LICENSED ENGINEER IN THE STATE OF NEW YORK.

DOB JOB #
BUILT-UP HEADER
BGM
ENGINEERING, LLC
2123 45TH ROAD, LONG ISLAND CITY, NY 11101
JOIST HANGER
24 CANFIELD DRIVE STAMFORD, CT 06902
TEL: 203.452.9408 and 646.499.0685
3"x3" ANGLE
SELF-DRILLING E-MAIL: [email protected]
3"x3" ANGLE CONNECT SCREWS 2" o.c. & 1"
TRACK FLANGE TO JOIST FROM EA. END
JOIST BRIDGING ANGLE LENGTH FLANGE WITH
14" 12" JOIST SELF-DRILLING SCREW @ DOUBLE TRACK
11-1/2" 12" o.c. TOP & BOTTOM & SECONDARY STAIR GIRDER
12" 10" 9-1/2" EA. END
JOIST 10" DOUBLE JOIST
8" 7-1/2" TRACK WEB STIFFINERS @
ALL BEARING POINTS, SECONDARY
9-1/4" 8" 7-1/2" STAIR GIRDER
ATTACH W/SELF-DRILLING
8" 5-1/2" 5 SCREW 1" FROM TOP &
BOTTOM AND 1 @ CENTER
TRACK SEE CHART 6" 3-1/2" 3 StiffClip LS as
CONTINIOUS BRIDGING manufactured by The
2-#10x3/4" TEK SCREWS TO END TO END DOUBLE TRACK Steel Network, Inc.
EA. ANGLE LEG @ 8' o.c. MIN PRIMARY STAIR GIRDER (888) 474-4876

NOTE: DOUBLE FLOOR JOIST


1. FASTEN BUILT-UP MEMBERS TOGETHER AT 12" O.C. MAX.
2. ALL SCREWS MUST BE INSTALLED

BRIDGING AND BRACING - FLOOR BRIDGING FLOOR SYSTEMS - CONNECTION TO GIRDER GIRDER ASSEMBLY DETAIL

CLIP ANGLE JOIST HANGER

BUILT-UP HEADER PROJECT:


PRIMARY STAIR GIRDER USE SINGLE TRACK IF 3'-6" OR LESS
USE TRACK AND JOIST FOR 3'-7" TO
7'-0" SECONDARY STAIR GIRDER
TRACK JOIST DOUBLE CONNECT TRACK
JOIST ON SIMPLE SPAN FLANGE TO JOIST
RIM TRACK FLANGE WITH 1 - #10 x 3/4" TEK
EXTEND TRACK 2' PAST CONNECT TRACK FLANGE SCREW @ 12" o.c TOP
SECONDARY STAIR
GIRDER
SEE TYPICAL DETAIL
TO JOIST FLANGE WITH
1 - #10 x 3/4" TEK SCREWS
@ 12" o.c. TOP AND BOTTOM
3" x 3" ANGLE,
@ EACH SIDE,
& BOTTOM AND EACH END
TRACK FOR PRIMARY
2040 EAST 5TH
CUT 1/2" LESS
FLOOR JOIST
StiffClip JC as manufactured
by The Steel Network, Inc.
AND EACH END THEN JOIST DEPTH
STAIR GIRDER MUST
EXTEND 2' PAST
SECONDARY GIRDER
STREET
ANGLE DOUBLE JOIST CONNECT
JOIST (TALLPLECES)
JOIST
ANGLE TRACK JOIST (888) 474-4876
FLOOR
JOIST
StiffClip LS as manufactured
by The Steel Network, Inc.
(888) 474-4876
WEBS BACK TO BACK

W/2-#10x16 TEK
BROOKLYN, NY
BUILT-UP JOIST TRIMMER
TAIL JOIST
SECOND COMMON JOIST
TRACK TRACK
SECONDARY
STAIR GIRDER
SCREWS @ 12" o.c. & 1"
FROM TOP & BOTTOM &
EA. END
11223
#10 x 3/4" SELF-DRILLNG SCREWS 1" MAY BE ELIMINATED
# 10 x 3/4" TEK SCREWS @ 2" FLOOR
FROM ENDS & 2" o.c. ALONG FOUNDATION JOIST
NOTE: FASTEN BULT-UP MEMBERS TOGETHER AT 12" O.C. MAX. o.c. AND 1" FROM EACH END #10 x 3/4" TEK SCREW @ 2" o.c.
SEE TYPICAL AND 1" FROM EACH END
DETAIL

TYPICAL FLOOR OPENING FRAMING STAIRS PARALLEL TO FLOOR JOIST FLOOR JOIST TO GIRDER GIRDER ASSEMBLY DETAIL
NO. DATE ISSUE/REVISION BY
1 XX/XX/XX PERMIT JB

FLOOR SYSTEM
(BY OTHERS)
RIM TRACK

SEE TYPICAL DETAIL


STEEL BEAM
ATTACH RIM
TAIL JOIST COMMON TRACK TO WALL
JOIST SIMPSON STRONG TIE S/BA CLIP. (BY DESIGN)
SEE TYPICAL DETAIL INSTALL PER MANUFACTURES
SPECIFICATIONS. FASTEN TO STEEL
JOIST CONNECT
BEAM WITH (4) 1/8"X2" FILLET WELD
W/(1)#10 TEK SCREW
OR WITH (6)-.157X 5/8" PAT.
FROM HANGER TO CONCRETE WALL.
(ENGINEERS APPROVAL REQUIRED
JOIST (BY OTHERS) DRAWING TITLE:
SECONDARY GIRDER FOR ALTERNATIVE HANGERS PRIOR
TO CONSTRUCTION)
PRIMARY GIRDER

JOIST TRACK
WEB STIFFENER
TYPICAL
TRACK
JOIST TRACK NOTE:
1. WELD, SCREW, OR P.A.F. ATTACH BRIDLE HANGER TO BEAM
STRUCTURAL
2. ATTACH BRIDLE HANGER TO WEB OF JOIST
LIGHT-GAGE
ATTACH WEB STIFFENER
@ EACH JOIST LOCATION.
ATTACH TO TRACK
DETAILS
WITH SCREWS.

FLOOR JOISTS

ATTACH TO JOIST
WITH SCREWS
IN PRE-DRILLED HOLES.

STAIRS PERPENDICULAR TO JOIST FLOOR SYSTEMS - CONNECTION TO WF BEAM JOIST BEARING ON CONCRETE WALL SEAL AND SIGNATURE DATE: 04/15/22

PROJECT No: BGM 22-029

DRAWING BY: IK

CHK BY: AK

DWG No:

S-301.00
BGM 22-029 X of X

DOB JOB #