Netelligent 1017A/B 10Base-T Hub User Guide
Netelligent 1017A/B 10Base-T Hub User Guide
10Base-T Hub
User Guide
NOTICE
The information in this publication is subject to change without notice.
This publication contains information protected by copyright. No part of this publication may be
photocopied or reproduced in any form without prior written consent from Compaq Computer
Corporation.
The software described in this guide is furnished under a license agreement or non-disclosure agreement.
The software may be used or copied only in accordance with the terms of the agreement.
Product names mentioned herein may be trademarks and/or registered trademarks of their respective
companies.
Compaq
Registered United States Patent and Trademark Office.
Contents
Chapter 1
Overview
Features......................................................................................................................... 1-1
Chapter 2
Hardware Description
Front Panel.................................................................................................................... 2-2
LED Indicator Panel .............................................................................................. 2-2
Station Ports........................................................................................................... 2-6
Daisy-Chain Switch............................................................................................... 2-7
Back Panel .................................................................................................................... 2-7
Port Connections.................................................................................................... 2-8
Power Socket ......................................................................................................... 2-8
Power Switch......................................................................................................... 2-9
Chapter 3
Installing the Hub
Site Requirements ......................................................................................................... 3-1
Connecting the Hub System ......................................................................................... 3-2
Chapter 4
Configuration
Stand-alone Configuration............................................................................................ 4-1
Connecting Multiple Hubs............................................................................................ 4-2
Using the RJ-45 Daisy-Chain Port ........................................................................ 4-2
Using Crossover Twisted-Pair Cable .................................................................... 4-3
Backbone Connection ................................................................................................... 4-4
Using the BNC Port............................................................................................... 4-4
Writer: Chris Seiter Project: Compaq Netelligent 1017A/B 10Base-T Hub User Guide Comments:
File Name:1017A_T.DOC Last Saved On:6/26/97 3:02 PM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vi
Appendix A
Troubleshooting
Diagnosing Hub Indicators .......................................................................................... A-1
System Diagnostics...................................................................................................... A-2
Installation ............................................................................................................ A-2
Configuration........................................................................................................ A-2
Hub Integrity ........................................................................................................ A-3
Appendix B
Port and Cable Assignments
Appendix C
Specifications
Appendix D
Regulatory Standards Compliance
Index
Writer: Chris Seiter Project: Compaq Netelligent 1017A/B 10Base-T Hub User Guide Comments:
File Name:1017A_T.DOC Last Saved On:6/26/97 3:02 PM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vii
Preface
This user guide is designed for the experienced network installer. It covers the
following information to help in the installation and operation of the Netelligent
1017A/B 10Base-T Hub:
Q Hardware description and summary of features
Q Hardware installation and configuration
Q Troubleshooting tips
Package Checklist
Carefully unpack the contents of the package and verify them against the
checklist given below.
Q 1017A/B 10Base-T Hub
Q BNC T-type connector
Q AC power cord
Q Compaq Netelligent User Guide CD
Q Compaq Netelligent 10Base-T Hub Quick Install Guide
Q Warranty registration card
If there are any incorrect, missing, or damaged parts, contact your Compaq
Authorized Reseller. If possible, retain the carton, including the original
packing materials, in case you need to repack the contents and return the hub for
repair.
Chapter 1
Overview
The Netelligent 1017A/B 10Base-T Hub is a 16-port Ethernet hub which
features an on-board microprocessor designed to monitor network utilization,
collisions, link and port partition status. The hub’s comprehensive LED
indicator panel simplifies installation and network troubleshooting by showing
network utilization and collision levels at the hub ports.
Features
The hub also provides the following features:
BNC and AUI Port – lets you connect the hub to 10Base2 (BNC) cabling and
10Base5 or fiber optic cabling via a suitable transceiver connected to the AUI
Flexible Installation – lets you mount the hub on desktop or in a standard 19-
inch rack
Chapter 2
Hardware Description
The 1017A/B 10Base-T Hub is a highly reliable network concentrator that
complies with IEEE 802.3 specifications. By passing data signals received on
any port to all other ports, without modification, this hub meets the
requirements for both Ethernet and IEEE 802.3 networks.
This chapter describes the main hub components. For easier management and
control of the hub, familiarize yourself with the front panel indicators. Figure
2-1 shows the front panel of the hub where the comprehensive LED indicators,
16 RJ-45 station ports and the uplink switch are located. Figure 2-2 shows the
trunk ports, power connector and power switch on the hub's back panel.
Front Panel
This section describes the 1017A/B hub’s front panel.
Power
Color: Green
Label: Power
Function: Power indicator
CPU
Color: Green
Label: CPU
Function: Power indicator
Utilization
There are five LEDs that represent the percentage of network utilization. The
corresponding LEDs light to show that the percentage utilization of LAN
bandwidth has reached this level. When active, these LEDs look like a stereo's
equalizer display.
For example, if network utilization reaches 1%, the LED labeled 1% lights.
However, if network utilization rises above 1% (for example, 30%), the LED
labeled 30 and all the other LEDs before it (that is, 1, 5, and 15) light in rapid
succession.
These LEDs monitor the share of valid network frames transmitted by this hub
within a 10Mb/s bandwidth. They provide a quick way to monitor the current
traffic load relative to the network's capacity.
Collision
The Collision LEDs assist the network manager in monitoring the percentage of
packet collisions occurring relative to the total packets received by the hub.
Similar to Utilization LEDs, the Collision LEDs have five numbers that
represent collision percentage. When collisions reach a level marked on the
LED display, the corresponding LED lights.
For example, if packet collisions reach 1%, the LED labeled 1% lights.
However, if collisions go beyond 1% (for example, 15%), the LED labeled 15+
and all the other LEDs before it (that is, 1, 3, 5, and 10) also light in rapid
succession.
There are 18 pairs of port status LED indicators. Each pair consists of a
Partition LED (top row) and Link/Traffic LED (bottom row). Each pair (or
column) has a label referring to the port number the LEDs monitor. For
example, the port status LED pairs labeled AUI and BNC monitor the AUI and
BNC ports on the back panel. The other 16 pairs are for the RJ-45 ports on the
front panel of the hub.
Partition
A port is temporarily partitioned when a line error or too many collisions are
detected on the attached segment. While it is automatically partitioned, the port
continues to transmit data to the segment. However, bad data is not repeated
from the segment. When the problem is corrected or a valid data packet is
received through the port, the port is automatically reconnected. When
partitioning occurs, the port's corresponding Partition LED will be continually
lit (YELLOW light). Otherwise, this LED should be OFF (unlit).
Link/Traffic
Link
Traffic
Traffic refers to the movement of packets being received by the port. A port's
corresponding Link/Traffic LED flashes (ON) in proportion to the rate of traffic
passing through the port. Through this LED, the network manager can easily
view the activity on a port.
Station Ports
The hub has 16 RJ-45 station ports. Using straight-through twisted-pair cable,
connect your workstation (via the network interface card's port) to any available
station port.
You can easily convert Port 16 into an uplink port by moving the uplink switch
to the MDI position (see “Setting the Uplink Switch” for related information).
This lets you expand your network by connecting the 1017A/B hub to another
compatible hub using straight-through twisted-pair cable.
To connect to another hub, you can also run straight-through twisted-pair cabling
from a station port on this hub to a crossover port on another hub. However, if you
must connect to another hub via stations ports at both ends of the cable, use
crossover cabling.
Back Panel
This section describes the hub's back panel components.
Port Connections
This hub has a built-in BNC transceiver for a connection using thin coaxial
cable. The BNC port can link up to 30 hubs on a thin coaxial cable segment.
The thin coaxial cable that links the BNC ports may be extended up to 185
meters and have computers or other Ethernet devices attached to it. When
connecting two hubs via BNC ports, there should be at least 0.5 meters (about
two feet) of coaxial cable between the two BNC ports. If the hub is at the end of
an Ethernet cable, plug and lock a 50-ohm (Ω) terminator to the T-type
connector on the BNC port.
NOTE : Terminate an open end of any T-type connector that is plugged into a BNC port
with a 50-ohm (Ω) terminator. In particular, when a hub using the BNC port connection
is at the end of an Ethernet segment, terminate the open end of the T-type connector
with a 50-ohm (Ω) terminator. Also, if the BNC port is not used, plug a T-type
connector to it and terminate both ends with a 50-ohm (Ω) terminator.
The AUI trunk port on the back panel can be used to further expand your
network by connection to -
Q Thin Ethernet cable (10Base2)
Q Thick Ethernet cable (10Base5)
Q Fiber-optic Ethernet cable
Attach an appropriate transceiver directly to the AUI port for thin Ethernet or
fiber-optic connection, or to the backbone itself for thick Ethernet connection.
(Connection to thick Ethernet is normally made by running an AUI drop cable
from the hub to a 10Base5 transceiver attached to the trunk line.)
Power Connector
The power connector accepts AC power from 100~240V at 50~60 Hz. The hub
is equipped with a universal full-range power source.
Power Switch
The power switch is located at the right side of the back panel. It is used to
power the hub on and off.
Chapter 3
Installing the Hub
This chapter describes how to install the 1017A/B 10Base-T Hub. It describes
specific installation requirements, installation procedures, and basic network
connections.
Site Requirements
Consider the following site requirements before you install the hub.
Q Verify that the power source meets the following electrical
specifications.
AC Power Frequency
100 to 240V (+/- 10%) 50 to 60Hz (+/- 3Hz)
The hub is equipped with a power supply that automatically detects the
input voltage level.
Q Leave at least 10 cm. of space at the front and back of the hub for
ventilation. We recommend that you install the hub in a cool, dry area.
Q If you plan to mount the hub in a rack, be sure you have all the required
screws, brackets and tools you need for proper installation.
Q Be sure the installation location is either a level surface (for example, a
table or shelf) or a standard, 19-inch equipment rack. A good location is
at the center of all the devices you want to link, close to the trunk
segment, and near a power outlet.
Q Be sure you connect the hub only to another 1017A/B or compatible
10Base-T hub.
NOTE : Do not plug in a phone jack connector to the RJ-45 port. This may
damage the hub. Instead, use only twisted-pair cables with RJ-45 connectors
that conform with FCC standards.
BNC - Plug the BNC T-type connector into the BNC port of the hub, and
use this port to connect the device to a 10Base2 Thin Ethernet trunk. If the
hub is at the terminal end of a trunk segment, then connect a 50-ohm (Ω)
terminator to the open end of the "T" connector. If the Ethernet BNC
trunk port has no connection, plug in the BNC T-type connector and lock
both ends with a 50-ohm (Ω) terminator.
AUI to BNC or fiber-optic - If you plan to use the hub's AUI port for
connecting to 10Base2 or fiber-optic cable, attach an appropriate MAU
converter to the AUI port. (Use an AUI to 10Base2 transceiver for
10Base2 cabling, or AUI to fiber optic transceiver for fiber-optic
cabling.) Connect the transceiver to the corresponding cable.
NOTE : If your transceiver provides an SQE (Signal Quality Error) test, then it
must be disabled.
NOTE : You can also connect a workstation to the AUI or BNC ports located on
hubs panel if required. However, be sure you use a proper transceiver when
connecting to these ports.
Plug the power cord into the power socket at the rear of the hub. Then
connect one end of the cord to an electric outlet.
Power on the hub by pressing the power switch to ON. Check the LED
indicator marked PWR on the front panel. It should be on.
The hub automatically selects the setting that matches the input voltage
connected. Therefore, no additional adjustments are necessary when
connecting it to any input voltage within the range marked on the back
panel.
NOTE : The hub supports a "hot remove" feature which lets you connect or
disconnect cables while the hub is powered on without disrupting operation.
The hub monitors link status for each port. If any device is properly
connected to the hub and transmitting a link beat signal, the Link
indicator lights for the corresponding port. If valid traffic is being
transmitted by the connected device, the same indicator (now referred to
as the Traffic indicator) flashes to indicate network activity.
If the Link indicator fails to light (or the Partition indicator does light)
when you connect a device to the hub, check the following items:
Be sure the twisted-pair cable is properly attached to the connected
device and the hub. Verify that the RJ-45 plug snaps into place
when attached.
See if the twisted-pair cable is functioning properly by using it for
another port and attached device that displays valid indications
when connected to the network.
Check the length of the twisted-pair cable to be sure it does not
exceed 100 meters.
Verify that the workstation’s adapter card is functioning properly by
trying it in another computer that has been successfully connected to
the network.
Chapter 4
Configurations
The 1017A/B 10Base-T Hub allows flexibility in configuring your network.
You can use the hub in a stand-alone or multiple hub configuration. The hub’s
RJ-45 uplink port (Port 16) lets you cascade multiple hubs using Category 3, 4
or 5 unshielded twisted-pair cable, or you can connect multiple hubs through a
backbone connection.
You can install the 1017A/B hub in a standard wiring closet or in a workgroup.
The only limitation is that all end-node devices (for example, workstations or
servers) must be within 100 meters of the connected hub.
Stand-alone Configuration
The 1017A/B hub can function as a simple stand-alone configuration as shown
below. Based on IEEE 802.3 standards, the maximum cable distance between
the hub and any workstation is 100 meters.
The 1017A/B hub provides an uplink port you can use to connect to another
hub. You can convert Port 16 to an uplink port by sliding the uplink switch to
the right (MDI) position. When the switch is in this position, you cannot use
Port 16 as a station port. Figure 4-2 shows an example configuration.
If you cascade hubs, IEEE 802.3 standards suggest limiting the maximum chain
length to four hubs. However, physical restrictions depend on actual repeater
delay. Therefore, if all your hubs are from Compaq, you can cascade up to five
hubs for a maximum LAN size of 75 nodes (using ports 1~15 on each available
hub). However, you can configure a larger network if you use a star or
hierarchical star configuration as described under “Guidelines for Multiple Hub
Configuration.”
NOTE : When using the uplink port to connect to another hub, use straight-through
(normal) twisted-pair cable. This cable is the same as that used for connecting the
hub to a workstation. For more information, see Appendix B - Cable Pin
Assignments.
With a crossover twisted-pair cable, you can connect the 1017A/B hub to a
compatible hub using any available RJ-45 port. Note that you should not enable
the uplink function when you use a crossover cable to connect Port 16 to a
compatible hub.
Backbone Connection
There are two trunk ports on the back panel to enable AUI and BNC
connections. You can use either type to link to an Ethernet backbone, depending
on the media type required.
The 1017A/B hub can be stacked with other hubs using the BNC port on the
back panel. Through this port, you can connect hubs via thin coaxial cable
(10Base2). A Thin Ethernet segment can run up to 185 meters and connect up to
30 nodes. However, an Ethernet trunk can contain no more than three coaxial
segments (10Base2 or 10Base5) if each segment extends to the maximum
length (allowed for Thin or Thick Ethernet). To further extend the trunk line,
you can use fiber-optic cable.
To control the number of hubs in a path, we recommend that you use one hub to
connect to several other hubs. By using a star configuration, you can link more
workstations together in a network than would be possible with a normal uplink
configuration. Also, be sure there is only one path between any two
workstations on the network to avoid corrupting data.
Appendix A
Troubleshooting
Diagnosing Hub Indicators
You can easily monitor the 1017A/B 10Base-T Hub using its comprehensive
panel indicators. These indicators help you identify problems the hub may
encounter. This section describes common problems and possible solutions.
Symptom: CPU indicator displays a steady green light long after power on.
Solution: Have the hub’s CPU replaced. Ask for dealer assistance.
Causes:
a. Hub has partitioned 10Base-T (RJ-45), 10Base2 (BNC), or 10Base5
(AUI) port.
b. Workstation’s network adapter, cable or hub port is defective.
c. If BNC cabling is used, the BNC connector may not be terminated.
Solution:
a. If port partitioning has occurred, the hub automatically enables the
port when the faulty condition disappears.
b. The most common cause of disconnection from a network or port
partitioning is a defective network adapter or cable connection.
Check the corresponding cable connections, or the workstation’s
network adapter for possible defects. Replace the defective cable or
adapter.
c. If a BNC cable connection is used, be sure the open ends of the BNC
segment are properly terminated with 50-ohm terminators.
NOTE : The BNC Partition LED also lights if the BNC port is not used (that is, no BNC
cable connected). Ignore the BNC Partition LED if you did not connect a BNC cable.
System Diagnostics
Installation
Verify that all system components have been properly installed. If one or more
components appear to be malfunctioning, test them in an alternate environment
where all the other components are functioning properly.
Cabling
1. Verify that the cabling type is correct. Be sure all cable connectors are
securely seated in the required ports. Straight-through cable should be
used for all standard twisted-pair connections.
2. When cascading two hubs using RJ-45 station ports at both ends of the
cable (that is, not the uplink port), be sure a crossover cable is used. You
should use crossover cable only if the uplink port is not available on
either hub.
3. When using Thin Ethernet cabling, be sure both ends are closed off with
50-ohm terminators.
4. Be sure all devices are connected to the network. Equipment may have
been unintentionally disconnected from the network.
External Adapters
1. Be sure the network adapter cards installed in the workstations are in
good working condition.
2. Be sure the media transceivers are functioning properly and the SQE test
has been disabled for all transceivers attached to the hub’s AUI port.
Configuration
If problems occur after altering the network configuration, restore the original
connections, and try to track the problem down by implementing the new
changes, one step at a time. Ensure that cable distances, repeater limits, and
other physical aspects of the installation do not exceed recommendations.
Hub Integrity
As a last resort verify the hub’s integrity with a power-on reset. Turn the power
to the hub off and then on. If the problem still persists and you have completed
all the preceding diagnoses, then contact your Compaq Authorized Reseller for
further assistance.
Appendix B
Port and Cable Assignments
Assignment Assignment
Pin
(Port 1 ~ 16) (Daisy-Chain Port)
1 Input Receive Data + Output Transmit Data +
2 Input Receive Data - Output Transmit Data -
3 Output Transmit Data + Input Receive Data +
6 Output Transmit Data - Input Receive Data -
4, 5, 7, 8 Not Used Not Used
Table B-1 . RJ-45 Pin Assignments
Schematics for both straight and crossover twisted-pair cable are shown below.
Straight-Through Crossover
(Hub) (Adapter) (Hub) (Hub)
1 IRD+ 1 OTD+ 1 IRD+ 1 IRD+
2 IRD- 2 OTD- 2 IRD- 2 IRD-
3 OTD+ 3 IRD+ 3 OTD+ 3 OTD+
6 OTD- 6 IRD- 6 OTD- 6 OTD-
Writer: Chris Seiter Project: Appendix B: Port and Cable Assignments Comments:
File Name:1017A_B.DOC Last Saved On:6/26/97 3:11 PM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B-2 Appendix B: Port and Cable Assignments
AUI Port
The following table shows pin assignments for the AUI port.
Pin Assignment
1 Collision In Shield
2 Collision In +
3 Data Out +
4 Data In Shield
5 Data In +
6 DC Power Common
9 Collision In -
10 Data Out -
11 Data Out Shield
12 Data In -
13 DC Power +
14 Power Shield
7, 8 ,15 No Connection
Writer: Chris Seiter Project: Appendix B: Port and Cable Assignments Comments:
File Name:1017A_B.DOC Last Saved On:6/26/97 3:11 PM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C-1
Appendix C
Specifications
Product Specifications
Network Specifications
Appendix D
Regulatory Standards
Compliance
EMI Warning
FCC Class A Certification
Compaq Computer Corporation
Model Number: 1017A/B
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference
that may cause undesired operation.
WARNING: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from the one
which the receiver is connected to
- Consult the dealer or an experienced radio/TV technician for help
You are cautioned that changes or modifications not expressly approved by the
party responsible for compliance could void your authority to operate the
equipment.
You may use unshielded twisted-pair (UTP) for RJ-45 connections. However,
use only shielded cable to connect I/O devices to this equipment via BNC
connection.
Warning:
• When connecting this hub to a power outlet, connect the field ground lead
on the tri-pole power plug to a valid earth ground line to prevent electrical
hazards.
www.fcc.gov/Bureaus/Compliance/WWW/tvibook.html
NOTE : In order to maintain compliance with the limits of a Class B digital device,
Compaq requires that you use a quality interface cable when connecting to this
device. Changes or modifications not expressly approved by Compaq could void the
users authority to operate this equipment. Suggested cable type is:
connection 2-8
Index devices 2-8
segment 2-8
trunk 3-2, 4-4, 4-5
A
F
AUI
attaching 3-2 FCC standards 3-2
drop cable 2-8, 3-2, 4-5 Fiber-optic
port 1-1, 2-8, 3-2, 4-5 cabling 1-1, 3-2
port connection 4-5 connection 2-8
AUI/BNC backbone ports 2-4 Ethernet cable 2-8
Automatic partitioning 1-1
Automatic polarity detection 1-1 I
B IEEE 802.3
networks 2-1
BNC recommendations 4-6
connections 4-4 specifications 2-1
monitor 2-5 standards 4-1, 4-2
port 1-1, 2-5, 2-6, 2-8, 3-2, 3-3, Indicator panel 1-1
4-4
port connection 2-8 J
T-type connector 3-2
Jabber lockup protection 1-1
C Jack connector 3-2
P
Partition LED 2-5
Power function 2-2
R
RJ-45
connectors 3-2
plug 3-3
port 1-1, 2-1, 2-4, 2-5, 2-6, 3-2,
3-3, 4-3
uplink port 4-1, 4-2
S
SQE test 3-3
T
Thick Ethernet 4-5
cable 2-8
segment 4-5
trunk 3-2
Thin Ethernet cable 2-8
segment 4-4
trunk 3-2
Traffic condition 2-6
Transceiver 1-1, 2-8, 3-2, 3-3, 4-5
BNC 2-8
optic 3-2
T-type connector 2-8
Twisted-pair cable 4-3
U
Utilization LEDs 2-3, 2-4
V
Ventilation 3-1