L99DZ100G - Eval - GUI
L99DZ100G - Eval - GUI
v1.0
Body Smart Power BU
Door Zone
L99DZ100G(P): DZ2015 Demo Board 22
ST Confidential
uC Section – SPC560B54L3
Door Zone
3
ST Confidential
Door Zone
FTDI-USB Interface 4
The two sections, the one with PC and the one with uC
(USB/UART) are interconnected with opto-couplers in order to
achieve Galvanic insulation and to protect PC in case of possible
short circuits on the pcb during tests.
ST Confidential
Door Zone
Chipboard Interface 5
The Chipboard interface is a small separated pcb hosting either L99DZ100G or L99DZ120.
On the back side some ceramic capacitors are accommodated.
These capacitor are connected to LDO1, LDO2, CP, VS.
ST Confidential
Door Zone
Power Supply Section 6
ST Confidential
Door Zone
Output Section 1/2 7
ST Confidential
Door Zone
Output Section 2/2 8
ST Confidential
Door Zone
L99DZ100G(P): Graphical User Interface 99
ST Confidential
Door Zone Main window (1/2) – Overview
10
Menu
Comminication Board Status
Exit
Communication Last data exchanged with GUI
WDC Trigger, GSB(N), FS, CM …
View Status Registers Clear
Settings
Testing
Debug
Help
GUI Version
ST Confidential
Door Zone
Main window (2/2) – Menu Items 11
Menu Structure
Exit – Closes the GUI Periodical Status Refresh - en/dis. periodical refresh
Communication of status registers if Tab Standard control active
Periodical Status Clear – en/ dis periodical refresh and
clear of status registers if Tab Standard control active
View
Periodical Status Refresh - en/dis. periodical refresh
Settings
of status registers if Tab Output control active
Periodical Status Clear – en/ dis periodical refresh and
clear of status registers if Tab Output control active
ST Confidential
Door Zone
SPI Registers Map Overview 12
Registers Addresses
Registers Names
Registers Values
(hexadecimal)
Registers Values
(binary)
ST Confidential
Door Zone
Standard Controls TAB (1/2) 13
The Standard Control Tab provides several controls related to the general settings of the device.
Here you can find controls for:
- V2 Settings
- Timers
- WU Settings
- WDC Settings
- Transceivers Settings
- Supply Voltage Monitoring
- Mode Control
ST Confidential
Door Zone
Standard Controls TAB (2/2) – Device Diagnosis 14
Error Flags
Visualization of all
error flags
ST Confidential
Door Zone
Outputs Controls TAB (1/5) 15
Current Monitor
Settings
Automatic DC
Compensation –
VLed Settings
Over Current
Recovery Frequency FSO LS Over High Side Outputs
Mirror Heater Control DIR Control
Current Control
ST Confidential
Door Zone
Outputs Controls TAB (2/5) – Half Bridge Outputs 16
Miroro Positioning
Virtual keyboard for mirror
position adjustment:
Up, Down, Left, Right
Error Signalisation
Yellow flag = Open Load Lock Control
Mirror Foldering
Autorecovery
Error Signalisation
Control of folding mirror
Enable auto-recovery
Red flag = Over Current
feature at Output
ST Confidential
Door Zone
Outputs Controls TAB (3/5) – HS Outputs Controls 17
OUT RON
Error Signalisation
Select HI / LO
RDS ON Red flag = Over Current
(OC @ Out 5 HS)
Error Signalisation
Yellow flag = Open Load
( OL @ Out 7)
Diag Setting
Open Load Level
Over Current Level
ST Confidential
Door Zone
Outputs Controls TAB (4/5) – PWM Configuration / DC
Compensation – VLed Settings 18
VLed Settings
VLed Settings
Automatic Duty Cycle
compensation VLED Automatic Duty Cycle
voltage set compensation Enable
ST Confidential
Door Zone
Electro Chrome Mirror Control TAB 19
Error flags
ECM System Control Indication of Low or
High EC voltage
Overview of ECM
system configuration
SPI bits indicator
and actual state
Visualization of
important control bits
Autorecovery
Enables auto recovery
feature for output
EC Enable
Brigthness Control
Set voltage on EC
glass = brightness
ST Confidential
Door Zone
Power H-Bridge Control TAB (1/3) 20
H-Bridge Circits
visualisation
Overview of
H-Bridge control system
configuration. (current
flow, Decay Mode)
H-Bridge control
Power H-Bridge
control and
configuration
H-Bridge control
Power H-Bridge Enable
Dual Motor Mode
Error Flags
Error flags related
to Power
H-Bridge
Drain – source
monitoring
ST Confidential
Door Zone
Power H-Bridge Control TAB (2/3) 21
Direction
Start
Select if HS1-LS2 or
Starts generate
HS2-LS1 bridge
PWM signal to
branch to be used for
drive the H-Bridge
motor supply
PWM Frequency
PWM Duty Cycle Sets PWM
Select PWM duty frequency in range
cycle = motor 1 .. 20kHz
rotation speed
OL Test
Decay Mode Select configuration
selection for H-Bridge
Select Decay on diagnosis
LS or HS; free
wheeling
D-S Threshold
Sets D-S monitoring
voltage threshold
ST Confidential
Door Zone
Power H-Bridge Control TAB (3/3) 22
Motor Current
Visualization of
current through
motor
Decay
Decay current
visualization
Error Flags
Error flags related to
Power
H-Bridge
Drain – source
monitoring
H-Bridge control
Clear Power H-Bridge Enable
Clears Dual Motor Mode
corresponding SPI
status register
ST Confidential
SPI Control Registers – an example
Door Zone
23
Bold Font
Bold are marked all
values what were
changed from Value change
previous state Click to any of these
(after receive from fields to change
L99DZ100P ) Register value
(available for all
control registers)
ST Confidential
Door Zone
SPI Status Registers – an example 24
ST Confidential
Door Zone
Watchdog/POR settings TAB 25
ST Confidential
Door Zone
L99DZ1xx: References 26
26
ST Confidential