Comparative
Comparative
Comparative
Ref. Standards IS:9669, IS : 2720 (Part XVI), BS 1377; 1924; EN 13286-47/ ASTM D 1883; AASHTO 193
Digital Indicator Micro controller multi line alpha numeric LCD display for all simultaneously channel
Load Frame, with LVDT 20mm, 50 kN Capacity, Three Speed 1.5, 1.25 & 2.5 mm/min
Mould - Mild Steel 150mm ID x 175 mm H
Perforated Base Plate - Mild Steel, for 12001 Mould
4 C.B.R. Apparatus Extension Collar - Mild Steel,150 mm ID x 50 mm high
Penetration Piston 50 mm face dia
Adjustable Bracket for Penetration Dial Gauge
Circular Metal Spacer Disc, with detachable handle, 148 mm dia x 47.7 mm high
Annular Metal Weight 2.5 kg, 147 mm dia with 53 mm dia central hole
Slotted Metal Weight 2.5 kg, 147 mm dia, with 53 mm dia slot
Perforated Plate 148 mm dia, with adjustable stem and lock nut
Cutting Collar
Rammer 2.6 kg, 310 mm controlled drop
Rammer 4.9 kg, 450 mm controlled drop
Requirements of Equipments in concrete technology Labs of Civil Department
Sl. No Name of Equipment’s &
Experiments
2 Trowel
3 G.I. Test Sieves 18"dia of 50 mm,
31.5 mm, 25 mm, 8 mm
Brass Test Sieves of 300 µm, 425 µm, 600 µm, 1.70 mm, 4 mm (2 set) as per relevant Indian Standard
Enamel Tray 10”x12”, Made of High Quality Enamel, White Porcelain Coated, Sturdy And Easy To Clean
Enamel Tray 12”x18”, Made of High Quality Enamel, White Porcelain Coated, Sturdy And Easy To Clean
Requirements of Equipments in ENVIRONMENTAL ENGINEERING Labs of Civil Department
Sl. No Name of Equipment’s &
Experiments
1 Desiccattor
2 BOD Bottle
3 Chloroscope
4 Muffle Furnace
ments of Equipments in ENVIRONMENTAL ENGINEERING Labs of Civil Department
Specifications
Made of Borosil , Desiccator used in labs are circular and made of heavy glass. These desiccators have two
compartments: a lower
compartment that stores a desiccant and an upper compartment where the reagent is placed
Chamber Size 200 mm x 200mm x 300 mm, Max temperature 1100°C, Continuous operating temp. 1000 0°C,
Heating element- Kanthal Al, Furnace Thermocouple- K Type, Chamber MOC-Ceramic fiberboard, Exterior
MOC- MS,SS, insulation- 1400 ZTL board, Temperature controller- PID controlled with SILICON Controlled
Rectifier. Power supply'-220 Volts 50Hz., Accessories-Asbestos Gloves SS tone.
Requirements of Equipments in STRENGTH OF MATERIAL Labs of Civil Department
Sl. No Name of Equipment’s & Specifications
Experiments
1 BEND REBEND TEST for ATTACHMENT Following attachments for AIMIL Make, Digital UTM,
ONLY, Model: AIM-653DG-1000, S. No. 24222 Universal
Digital UTM, Model:AIM-653DG-1000, S. No. Testing Machine, 1000 kN, Computerised
24222, Universal Testing Machine, 1000 kN, Bend and Rebend Test Attachment:
Computerised For Bend test and Re-bend test (accessories as per IS
1599 & IS 1708),
Bend and Re-bend test attachments for specimens up to
40 mm diameter as per the requirement of IS-1599-
1976,
Mandrel Diameters (Loading elements) in mm: 16, 20,
24, 30, 32, 36, 40, 48, 50, 56, 60, 64, 70, 72, 75, 80, 84, 96,
100, 108, 112, 120, 125, 128, 140, 144, 150, 168, 175, 180,
192, 200, 216, 224, 240, 252, 256, 270, 280, 288, 320, 324,
360 mm.