Requirements of Equipments in GEOTECHNICAL ENGG.

Labs of Civil Department


COMPARATIVE STATEMENT
Sl. No Name of Equipment’s & Specifications QUANTITY ADVANCED ETHER TECHNOSYS VANS
Experiments MICRO DESIGNS ENGINEERS SYSTEM SYSTEM
Used for grain size analysis of soils where more than 10% of the material will pass through 75 microns I. S. Sieve.
1 Hydrometer Apparatus Manufactured from clear transperent glass having uniform clarity throughout the upper end on which density scale is
engraved. The scale range is 0. 995 to 1. 030 density (gms/cc) at 27°c. Smallest division on the scale is 0.0005.
As per the IS: 2720 (Part 2)
The speed of drying (about 30 min), The infrared radiation is controlled by a
voltage regulator. The instrument is provided with an indicator lamp. The balance scale (drum) is divided in terms of moisture percentage on wet weight basis, which are read directly
from it. Graduations are from 0 to 100% in 0.2 % divisions.
Suitable for operation on 220 V, 50 Hz, Single phase,AC Supply.
Capacity: min 5g approx.
Sensitivity : min 10 mg approx.
Range : 0 to 100% moisture content
Infra - Red Moisture
2 on wet weight basis.
Metre
Reading accuracy : min ± 0.20%
Probable error : min ± 0.25% in the lower range upto compared to 25% and ± 1% for moisture contents
Oven methods : above 50% Equipment consisiting of :- Infra Red Lamp
Thermometer (L-shaped)

Grain Size Analysis Apparatus (Pipette Method)


Specifications : The apparatus consists of a sliding panel which moves up and down by means of a screw allowing
Anderson pipette fixed to it to be raised or lowered vertically. A sedimentation tube is held by a laboratory clamp
provided on the stand below the pipette. The depth of immersion is measured by a scale graduated in mm at the side
of the sliding panel. Supplied complete with Anderson pipette 10 ml. at the side capacity made from glass, and a
sedimentation tube also of glass of 500 ml capacity and 50 Nos Test forms.
Grain Size Analysis Accessories & Spares :
3 1) Sedimentation pipette (Anderson pipette) 25ml.
Apparatus
2) Sedimentation tube 1000ml.
3) Sedimentation pipette 10ml.
4) Sedimentation tube 500ml.
5) Test forms pad of 50

Ref. Standards IS:9669, IS : 2720 (Part XVI), BS 1377; 1924; EN 13286-47/ ASTM D 1883; AASHTO 193
Digital Indicator Micro controller multi line alpha numeric LCD display for all simultaneously channel
Load Frame, with LVDT 20mm, 50 kN Capacity, Three Speed 1.5, 1.25 & 2.5 mm/min
Mould - Mild Steel 150mm ID x 175 mm H
Perforated Base Plate - Mild Steel, for 12001 Mould
4 C.B.R. Apparatus Extension Collar - Mild Steel,150 mm ID x 50 mm high
Penetration Piston 50 mm face dia
Adjustable Bracket for Penetration Dial Gauge
Circular Metal Spacer Disc, with detachable handle, 148 mm dia x 47.7 mm high
Annular Metal Weight 2.5 kg, 147 mm dia with 53 mm dia central hole
Slotted Metal Weight 2.5 kg, 147 mm dia, with 53 mm dia slot
Perforated Plate 148 mm dia, with adjustable stem and lock nut
Cutting Collar
Rammer 2.6 kg, 310 mm controlled drop
Rammer 4.9 kg, 450 mm controlled drop
Requirements of Equipments in concrete technology Labs of Civil Department
Sl. No Name of Equipment’s &
Experiments

Automatic Mortar Mixer,


1
Digital, Capacity 5 L

2 Trowel
3 G.I. Test Sieves 18"dia of 50 mm,
31.5 mm, 25 mm, 8 mm

4 Brass Test Sieves 8"dia of 300 µm,


425 µm, 600 µm, 1.70 mm, 4 mm

5 Enamel Tray 10”x12”


6 Enamel Tray 12”x18”
Requirements of Equipments in concrete technology Labs of Civil Department
Specifications

Automatic/Manual Mortar Mixer, 4.75 litre nominal capacity (Bowl)


Application: Preparation of standard prisms with Automatic/Manual mixing procedure in accordance with IS:10890, EN 196-1 & EN 196-3 This apparatus has specially been designed to prepare cement mortar for strength determination as specified in IS:4031. It can also
be used in mixing lime with pozzolonic materials for determination of lime reactivity (as per IS: 1727) and for uniform mixing of soils with additives such as lime, cement, etc.
Special Features :
• Water Burette
• Choice of automatic mixing cycles as per EN Standard
• Automatic or Manual modes
• User defined Mixing cycle
• Microprocessor Control
• Sand Dispenser
The mixer is designed to mix mortars and cement pastes primarily to the requirements of EN 196. The mixing paddle has a planetary motion and is driven by a motor with a microprocessor based speed and program controller. The mixer can be operated either in an
automatic or manual mode. When the mixer is used in the manual mode, the two mixing speeds can be changed by means of a soft touch button, without switching off the motor. In the automatic mode any one of the pre-set mixing programmes may be selected.
It has been designed to prepare cement mortar for strength determination as specified in IS: 4031. It can also be used in mixing lime with pozzolonic materials for determination of lime reactivity (as per IS: 1727) and for uniform mixing of soils with additives such as lime,
cement.
Standard Supply includes:
Basic unit with stainless steel mixing bowl and stirrer, Program controller with status indicators to run the Mixer in fully Automatic or Manual mixing mode.
Low Speed 140+/-5 , 62+/-5
High Speed 285+/-10, 125+/-10
Suitable for operation on 220V, 50Hz, single phase, AC supply.

Made of iron, standard size


G.I. Test Sieves of 50, 31.5, 25, 8 mm (2 Set) as per relevant Indian Standard

Brass Test Sieves of 300 µm, 425 µm, 600 µm, 1.70 mm, 4 mm (2 set) as per relevant Indian Standard

Enamel Tray 10”x12”, Made of High Quality Enamel, White Porcelain Coated, Sturdy And Easy To Clean
Enamel Tray 12”x18”, Made of High Quality Enamel, White Porcelain Coated, Sturdy And Easy To Clean
Requirements of Equipments in ENVIRONMENTAL ENGINEERING Labs of Civil Department
Sl. No Name of Equipment’s &
Experiments

1 Desiccattor

2 BOD Bottle

3 Chloroscope

4 Muffle Furnace
ments of Equipments in ENVIRONMENTAL ENGINEERING Labs of Civil Department
Specifications

Made of Borosil , Desiccator used in labs are circular and made of heavy glass. These desiccators have two
compartments: a lower
compartment that stores a desiccant and an upper compartment where the reagent is placed

300ml bottle , made of borosil


Square unbreakable test tube - 2 Nos, glass dropper with rubber test-1No, O-Toluidine reagent-125ml, packed in
thermocol box, to check chlorine in drinking water from 0.25ppm to 2ppm

Chamber Size 200 mm x 200mm x 300 mm, Max temperature 1100°C, Continuous operating temp. 1000 0°C,
Heating element- Kanthal Al, Furnace Thermocouple- K Type, Chamber MOC-Ceramic fiberboard, Exterior
MOC- MS,SS, insulation- 1400 ZTL board, Temperature controller- PID controlled with SILICON Controlled
Rectifier. Power supply'-220 Volts 50Hz., Accessories-Asbestos Gloves SS tone.
Requirements of Equipments in STRENGTH OF MATERIAL Labs of Civil Department
Sl. No Name of Equipment’s & Specifications
Experiments
1 BEND REBEND TEST for ATTACHMENT Following attachments for AIMIL Make, Digital UTM,
ONLY, Model: AIM-653DG-1000, S. No. 24222 Universal
Digital UTM, Model:AIM-653DG-1000, S. No. Testing Machine, 1000 kN, Computerised
24222, Universal Testing Machine, 1000 kN, Bend and Rebend Test Attachment:
Computerised For Bend test and Re-bend test (accessories as per IS
1599 & IS 1708),
Bend and Re-bend test attachments for specimens up to
40 mm diameter as per the requirement of IS-1599-
1976,
Mandrel Diameters (Loading elements) in mm: 16, 20,
24, 30, 32, 36, 40, 48, 50, 56, 60, 64, 70, 72, 75, 80, 84, 96,
100, 108, 112, 120, 125, 128, 140, 144, 150, 168, 175, 180,
192, 200, 216, 224, 240, 252, 256, 270, 280, 288, 320, 324,
360 mm.

2 EXTENSOMETER for Extensometer: Electronic extensometer


Digital UTM, Model: strain gauge type with 2.5 mm extension and
AIM-653DG-1000, S. No. 24222, Universal gauge length 25 & 50 mm for tension test.
Testing Machine, 1000 kN, Computerised