CABLE FAULT LOCATOR


TDR-TA4.7
Application
• High resolution cable fault location with various methods
(TDR, ARM, ICM, DECAY)
• Fault location range 1 to 256 kilometers
• Cable length measurement and cable integrity tests
• Measurement of the distance to the heterogeneity of the
cable impedance or low-resistance fault, using TDR method
• Measurement of the distance to the high-resistance fault,
using the Arc Reflection Method (ARM) in complex with the
high-voltage pulse generator (HVPG)
• Measurement of the distance to the high-resistance fault,
using the Impulse Current Method (ICM) or Decay Method in
complex with the high-voltage pulse generator (HVPG)

SPECIFICATIONS
TDR-TA4.7
Implemented measurement methods TDR, ARM, ICM, DECAY
Display color 10.4" TFT 640 x 480 pixels, LED-backlight 400 cd/m2
Distance measurement range PF=1.500: 1 m … 256 km
Pulse Width 10 ns …100 us
Pulse Amplitude 18 V, 86 V (on open circuit)
Distance measurement relative error 0.01% ... 0.2% (depending of sub-range)
Distance measurement absolute error 0.125 m (on sub-ranges <= 1 km) … 32 m (on 256 km sub-range)
Effective sampling rate 800 MHz
Input impedance Input impedance
Attenuation overlap 73 dB
Asynchronous noise suppression averaging 1 … 64 times
Propagation Factor(PF) range PF=1.000 … 3.000
Synchronization ARM external (TRIG), internal (delay 0 …50 ms, step 0.2 ms)
Synchronization ICM, DECAY threshold level (-165 V … +165 V, step 2 V)
Non-volatile internal memory 300 waveforms, 500 PF values
Data exchange via USB-Flash
File types waveform (*.tdr, up to 8000 px), screenshot ( *.jpg)
User interface language English
Connectors TDR (BNC), TRIG (BNC), WAVE (BNC), USB-A
Power AC 12 V, built-in Li-Ion battery (7,2 ± 0,7)V 7,0A
Continuous running from the battery at least 6 hours. Continuous running via AC adapter is not limited
Overall dimensions 363 mm * 295 mm * 170 mm
Weight 3.7 kg
- operating temperature range from -20 to 40 °C;
Working conditions - relative humidity 98%, at 25 °C;
- transportation and storage conditions from -50 to 50 °C
BASIC SET OPTIONAL ACCESSORIES
Cable Fault Locator Transitional Device
AC Adapter 12 V Arc Discharge Generator GI-TA
Connecting cables
CD-ROM with software
User manual in English
Carrying bags

Office 6, 10A (bl.2),1-Vladimirovskaya Str, Moscow, 111123, Russia


www.technoac.com Tel: +7 (495) 258-86-49 E-mail: [email protected] Skype:ntc_technoac

You might also like