Example Problem 3.3 Chapter 3

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 1

Determination of pipe drain spacing using

ERNST method for two-layer aquifer.


Discription units Data Remarks
Depth of upper layer D1 m 22.5 Roll No 18
hydroluic conductivity K1=Kr=Kv m/d 19.6
Depth of lower layer D2 m 21.5
hydroluic conductivity K2 m/d 21.2
Diameter of drain pipe m 0.15
depth of ground surface to drain pipe m 2.5
Required root zone depth m 1.5
Constant recharge rate R m/d 0.0228
H m 1
Dv m 0.5
Do m 20
D1 m 20.5
K2/K1 1.0816327
Do/D1 1.075
a 2 from table
∑(KD)h m2/d 857.6
raduis of drain pipe m 0.075
Parameter (µ) m 0.2356125
Part 1 0.0005816
Part 2 0.0000033
Part 3 0.0019012
a 1
b 572.1043286896
c -33849.33
S With (+) m 54.0583628759
S with (-) m -626.1626915655 Ignore