EC-12S Resting and Stress ECG System Labtech Ltd. Technical specification

TECHNICAL SPECIFICATIONS OF EC-12S RECORDER


Leads I, II, II, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6, NEHB
BP measurement method Auscultational
BP interval of measurement 30-260 mmHg; Device’s measuring limit: 20-280 mmHg
BP measurement’s accurary ± 3 mmHg
PC connection Bluetooth (wireless type)
Patient protection EN 60601 (IEC-601-1), CF type
Power supply / Can be exchanged during 2 x 1,2 V rechargeable batteries
recording! / (or 2 x 1.5 V AA alkaline battery)
Dynamic interval ±20 mV
DC offszet range ±1000 mV
Frequency response 0.05 Hz … 150Hz
Sampling rate 1000 Hz
A/D resolution 16 bit
Input impedance ≥ 120 MΩ
Common Mode Rejection Ratio > 120 dB
Size 125 x 70 x 33 mm
Weight ~ 200 g (wireless type)

STRESS SOFTWARE FUNCTIONS


 Lead-off warning  Precise QRS classification  colour-coded ST level, slope and
ST loop graphs
 Store the Indication and  SAECG  Smoothing, baseline, mains
medication of the patient filters
 MET and VO2 computation  HR, BP, LOAD, MET graphs  Customizable alarm and stop
criteria
 Ergometer and treadmill  Show T-wave deviation: QT, QTc  Vectorcardiography in stress-
database trends continuous test
 Arrhythmia analysis  Weber amd Morris function  Bayes theorem in the analysis
classification
 Duke-nomogram  Borg rank  QRS frontal axis
 Exercise and condition plan  Pacemaker detection  Paper speed: 5-12,5-25-50-100-
200 mm/s
 Amplitude: 2,5, 5-10-20-40  Gender and age-specific ECG  Full Disclosure ECG recording
mm/mV analysis software
 Modifiable protocols under  standard stress protocols,  Automatic, manual, end of
Load custom protocols stage blood pressure measure
 Speed measure km/h and mph  BMI and BMI prime  Adjustable infoboxes
 Rhythm curves  Templates analysis  Event screen
 QT, QTc, QT%  QRS Axis  Ectopic rate
 Average view  ECG contrast  Milimeter paper settings
 Display channels: 3, 6, 12,  
additionally: Cabrera, Custom

Labtech Ltd. Homepage: www.labtech.hu Phone: +36-(52)-500-128


Address: Vág utca 4. H-4031, Debrecen, Email: [email protected] Fax: +36-(52)-500-129
Hungary
EC-12S Resting and Stress ECG System Labtech Ltd. Technical specification

REST SOFTWARE FUNCTIONS


 5, 10, 20 sec and long ECG  Rhythm curves  Lead-off warning
record
 Precise QRS classification  Store the Indication and  Smoothing, baseline, mains
medication of the patient filters
 Arrhythmia analysis  QRS frontal axis  Full Disclosure ECG recording
 Paper speed: 5-12,5-25-50-100-  Amplitude: 2,5, 5-10-20-40  BMI and BMI prime
200 mm/s mm/mV
 Automatic diagnosis  Average vire  ECG contrast
 Milimeter paper settings  Display channels: 3, 6, 12,
additionally: Cabrera, Custom

BASIC FUNCTIONS OF SOFTWARE


DATABASE FUNCTIONS
 Common database for all  Record recycle bin function  Search records
Labtech system
 Acquire Patient ID from barcode  System log  Local database, Network
reader database: Microsoft SQL Server
database, SQLite database
 Acquire Patient ID using  Filter records  Different date format
magnetic card reader
 Medical record for patients  Import – export records  Password protected software
starting
 Access control  Import – export records by date
BASIC FUNCTIONS
 Automatic update  Normal and MSI install  Full screen mode
 HIS integrations: GDT, DICOM  Two display mode  Cubios HRV export
MODALITY WORKLIST,
Cardiospy SDK
 FTP integration  Email function  AHA / IEC electrode placement
PRINT AND EXPORT FUNCTIONS
 Report printing and exporting  Automatic print  Selectable reports
 Color and Black and white  Contrast settings  Resizable resolution
reports
 Customizable company logo  Automatic diagnosis  Custom report
 Adjustable paper speed and  Import /Export settings  Export ECG data to CSV, SCP,
amplitude Dat format
 Export QRS data  Export N-N intervals  Export R-R intervals

Labtech Ltd. Homepage: www.labtech.hu Phone: +36-(52)-500-128


Address: Vág utca 4. H-4031, Debrecen, Email: [email protected] Fax: +36-(52)-500-129
Hungary
EC-12S Resting and Stress ECG System Labtech Ltd. Technical specification

SOFTWARE MINIMUM CONFIGURATION


Processor minimum: Intel® Core™ i3
recommended: Intel® Core™ i5 or better (Sandy Bridge or newer architecture)
RAM minimum: 4 GB;
recommended: 8 GB
Graphics card DirectX 10 compatible, min. 128 MB video memory
Display minimum: min. 1280x800 resolution
recommended: 22” monitor
1920 x 1080 resolution (Full HD)
HDD 500 GB (SATA II or newer recommended)
Interface 1 USB port for the EC-2H/3H/12H/ABP recorder
1 USB port for the USB-02 key
1 USB port for the printer
Printer Laser (printing speed: 15-20 page/min, color printer recommended)
Operating system Windows 7, Windows 8, Windows 8.1, Windows 10
(32-bit or 64-bit versions)
*Windows XP is no longer supported by Microsoft. Labtech provides only limited support for previously installed
systems.

Labtech Ltd. Homepage: www.labtech.hu Phone: +36-(52)-500-128


Address: Vág utca 4. H-4031, Debrecen, Email: [email protected] Fax: +36-(52)-500-129
Hungary