SMP Products Internal Storage Slim SATA Installation Guide
SMP Products Internal Storage Slim SATA Installation Guide
MN912161EN, version 1
MN912161EN, version 1
Chapter
1
Introduction
In this chapter: Some of Eaton's SMP products share similar features; this is the
case of the bottom panel enclosure which is identical for both the
• Getting assistance SMP SC-2200 computing platform and the SMP SG-4260 automation
• Safety information platform.
• The SMP device bottom panel This document provides the information related to the installation
of an optional Slim Sata SSD for additional storage on an SMP
device. For specific informaton related to other features and use of the
SMP device like for example: system configuration and setup, LED
identification, dimension drawings, system points and settings, refer
to the User Manual that is related to the SMP device in which you are
installing the Slim SATA drive.
Eaton •1
Chapter 1: Introduction
Technical Support
Eaton
Energy Automation Solutions
Business hours are from 8 a.m. and 5 p.m. CST, Monday to Friday.
Power LED
Watchdog timer and general status
LED
Safety Precautions
Before attempting to install or use the SMP device, review the safety precautions that are included in the
related SMP device's User Manual.
The following safety precautions are mainly related to the power supplies connections and handling; they
are listed as a reminder to help prevent injury or damage to equipment:
Caution: Only qualified personnel should work on the SMP device. Installation and maintenance
personnel should be familiar with the technology and hazards associated with electrical equipment.
Caution:
The SMP device is a double pole/neutral fusing system: it has a fuse on the Neutral line.
Danger: Connecting the SMP device to a power source that does not respect the power supply
specifications may damage the unit.
Caution:
A switch or circuit-breaker must be included as part of the installation: It must be located in close
proximity to the SMP device and within easy reach of the operator. It must also be marked as the
disconnecting device for the SMP device.
Warning:
Before attempting the installation or maintenance of the SMP device, other than the hot swapping of
the power supply or RAID storage drives, turn off the corresponding power supply equipment.
Warning:
Make sure that the hot-swapping of the power supplies or the storage SSD drives on the SMP
device are performed by qualified personal only.
Note: SSD storage drives are used only with the SMP SC-2200.
Danger:
The power supply terminal block is IP20 finger proof. Direct contact (e.g., using a tool) may cause
electrical shock that can cause injury or death.
Warning:
The SMP device contains devices sensitive to electrostatic discharge (ESD). Work surfaces and
the personnel must be grounded before installing or replacing a communication module. The
same recommendation applies if you have to open the SMP device case; however, remember that
opening the case voids the warranty.
Eaton •3
Chapter 1: Introduction
The following figure shows the SMP SC-2200 computing platform bottom panel enclosure (cover plate
removed, one Slim SATA inserted with its ESD shield); the bottom panel enclosure is identical on the SMP
SG-4260 automation platform.
ID Description
1 SlimSSD 1 Built-in SSD slim SATA drive bay used for basic internal storage.
When only one SSD slim SATA drive is installed on the SMP device platform, it must be
placed in the SlimSSD 1 bay.
Note: An optional Slim SATA drive can only installed in the SlimSSD 1 bay on
the SMP SG-4260 automation platform.
2 SlimSSD 2 Built-in SSD slim SATA drive bay used for optional internal storage.
Note: This drive bay is not functionnal on the SMP SG-4260 automation
platform.
ID Description
3 S3 Control switches (dip switches) used to setup some options for the SMP device . The
four (4) control switches are used as follow:
SMP device
control Note: The control switches description on the board correspond to the switches
switches behavior for the ON position.
4 ON: Dual power supplies, Main - Used only when the optional dual
Backup mode power supply is installed.
OFF: Dual power supplies, Alternate ON: Dual power supplies, Main -
mode Backup mode
OFF: Dual power supplies, Alternate
mode
4 Shield This shield must be used to be complient with EMI standards. It is factory installed if
the SMP device is ordered with the SSD slim SATA drive(s). If a SSD Slim Sata drive
is ordered separatly by the customer, Eaton provides the shield and four (4) screws
together with the drive.
Note: Ordering SSD Slim Sata drives from Eaton ensures that the SMP device stays substation-
grade. A third party drive provides no warranty with respect to the substation-grade compliancy.
Eaton •5
Chapter 1: Introduction
2
Slim SATA installation
In this chapter: The SMP devices use the Slim SATA SSD differently; for the SMP
SC-2200 computing platform, the Slim SATA SSD drives inserted in
• Installing SSD Slim SATA drives the SlimSSD 1 and SlimSSD 2 bays are used for basic internal storage
for internal storage memory for operating system and user data applications.
On the SMP SG-4260 automation platform, the optional Slim SATA
SSD drive can be inserted only in the SlimSSD 1 bay and is used as
additional storage for data logging applications.
Table 2: Slim SATA memory size allowed for the SMP units in the
bottom panel bays
Eaton •7
Chapter 2: Slim SATA installation
Note: The picture shown in this section does not show the ESD protective covers installed over the
Slim SATA drives. Refer to the bottom panel section for a picture with an installed shield.
The installation procedure is simple, it must however be exercised with care to prevent accidental damage
caused by static electricity.
Warning:
The SMP device contains devices sensitive to electrostatic discharge (ESD). Work surfaces and
the personnel must be grounded before installing or removing a drive into or from the bottom panel
drive bay. Opening the SMP device's bottom panel does not void the warranty.
Warning:
If you add a drive to the SMP device configuration, its operating temperature will change. For
complete temperature derating information, refer to the device's Catalog Data document.
Instructions:
1. Place the SMP device upside-down on a flat surface and make sure it is grounded.
2. Remove the six (6) screws keeping the bottom panel's protective cover in place.
Eaton •9
Chapter 2: Slim SATA installation