SOFAR 3.
3K~12KTLX-G3
3.3 / 4.4 / 5.5 / 6.6 / 8.8 / 11 / 10 / 12 kW SOFAR SOFAR SOFAR SOFAR SOFAR SOFAR SOFAR SOFAR
Datasheet 3.3KTLX-G3 4.4KTLX-G3 5.5KTLX-G3 6.6KTLX-G3 8.8KTLX-G3 11KTLX-G3 10KTLX-G3-A 12KTLX-G3
THREE-PHASE DUAL MPPT
Input (DC)
Max. input voltage 1100V
Rated input voltage 650V
Start-up voltage 160V
Product advantages MPPT operating voltage range 140V~1000V
Number of MPPTs 2
Maximum efficiency 98.6% Number of DC inputs 1/1 1/2
Max. input MPPT current 15A/15A 15A/30A
Low start-up voltage, wide MPPT voltage Max. input short circuit current 22.5A/22.5A 22.5A/45A
Maximum DC input voltage 1100 V Output
Full (AC) voltage range (V)
power MPPT 200-500 210-500 260-500
Rated output power 3000W 4000W 5000W 6000W 8000W 10000W 10000W 12000W
Smart string level monitoring
Max. apparent power 3300VA 4400VA 5500VA 6600VA 8800VA 11000VA 10000VA 13200VA
Remote firmware upgrade Max. output current 5A 6.7A 8.3A 10A 13.3A 16.7A 15.2A 20A
Rated output voltage 3/N/PE, 230/400Vac
Natural cooling, no fans, low noise Output voltage range 310Vac-480Vac
Type II SPD for both DC and AC side Rated output frequency 50/60Hz
Output frequency range 45Hz-55Hz/55Hz-65Hz
Active power adjustable range 0~100%
THDi <3%
Power factor 1 (adjustable+/-0.8 )
22.5A/22.5A
Efficiency 0~100%
Max. efficiency 98.40% 98.40% 98.40% 98.40% 98.50% 98.50% 98.50% 98.50%
European efficiency 97.50% 97.50% 97.50% 97.50% 98.00% 98.00% 98.00% 98.00%
Protection
DC reverse polarity protection Yes
Anti-islanding protection Yes
Leakage current protection Yes
Ground fault monitoring Yes
PV-array string fault monitoring Yes
DC switch Yes
SPD PV: type II, AC: type II
General Data
Ambient temperature range -30~+60
Self-consumption at night <1W
Topology Transformerless
Degree of protection IP65
Allowable relative humidity range 0~100%
Max. operating altitude 4000m
Cooling Natural
Dimension (W×H×D) 430×385×182mm
Weight 17kg 18kg
Display LCD & Bluetooth +APP
Communication RS485/WiFi
IEC/EN 61000-6-1/3, IEC/EN 61000-3-2/3, IEC/EN 61000-3-11/12,
Standard IEC 62116, IEC 61727, IEC 61683, IEC 60068-1/2/14/30, IEC/EN 62109-1/2
G98/G99, CEI0-21, VDE-AR-N 4105, VDE V 0126-1-1, EN 50549-1, UNE 217002-2020
*All specifications are subject to change without notice. 03 / 2023——V2