03 408301 4800000882 FHD Mec DRG 600003

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5 6

GENERAL KEY PLAN: N

VJA-PS-ME Review: (17-10-2024):


QIBLA

No Comments 29 29 29
ROAD ROAD

CONTROL UNIT
ODOR

DIM
DISINFECTION
6.34

)x:m
(L
3.95TANK

(W
)m
SHADED
AIR BLOWERS
AREA FOR

30 30

6.44

SHT
DIM
7.5
AERATION TANK
m (

mW
)(W
.Dm
3
x

)Xm
(L

)X
3
(.
D

)
EQUALIZATION

&
29

DIM
MBR TANK
2.2
2.54

W
)x:m
(L
EQUALIZATION TANK

(TH
4
MBR TANK

)m
DIM

)X 20
:m
(L
13

(W
)X
3 m
W

.D
)
DIM

TH
4
2.2
2.54

W
x):m
(L

6.44
DIM
7.5
AERATION TANK
m

)Xm
(L
(

m
:

3
(.W
)X
D

)
(6.34

3.95
SLUDGE BREAK
DIM

:Lm
3
x
)W TANK

(W
).D
x m
ANOXIC TANK

6.1
DIM

)X
5 :m
(L
m

m
3(W
)X
.

D
)
ROAD

17 ROAD

DIM
SLUDGE HOLDING
DIM

)x 10
:m
(L
4 TANK

(W
)m
UTILITY BUILDING
10

5
)x:m
(L
(

W
)
(W
m

(W
m
.3
x
D

.D
) 3
x
30 30 29 29 30 COMPACTOR

COMPACTOR

24
16

29

. 10 . 10
18
30

UNIT MODEL / GENERAL CONSTRUCTION SUPPLY FAN DATA SUPPLY MOTOR DATA . 12 13
22
Warehouse Facility +
Workshop
Laundry
21

.
NO AHU REFERENCE No ID Unit Material Name AHU Rev No Unit Qty Length Width Height Weight SFPv (clean filters) SFPe (medium filters) Panel Thick. Insulation Mat. Panel Inner Skin Panel Outer Skin Profile Flat Roof Supply Air Flow No of fans Model ESP Total Static Pressure Discharge Velocity Rotation Speed Work Rotation Speed Max Fan Shaft Power Motor Type Nominal Motor Power Nominal Motor Current Electrical Power Input Efficiency Class No of poles Power supply 30 28

. 23ADMIN 500sqm

mm mm mm kg W/(m3/s) W/(m3/s) mm m3/h Pa Pa m/s RPM RPM kW kW A kW


1 SUPERMARKET1500sqm

.
PUMP ROOMFOR
WATER & FIRE

. WATERTANK FUTUREWATER

5
VET150
sqm 5000M3 TANK5000M3

RECREATIONAL POOL
240.00
m

FIRE TANK 600M3

FIRE TANK 600M3


1 FAHU-01 1931077 ADN02HGD5 1 1 3340 1000 930 524 1556 1828 62 FOAM Precoated 1 mm Precoated 1.2 mm Aluminium Natural Thermal Break YES 2520 1 SYQ250-R 325 816 6.8 3107 4100 1.02 AC 1x1.5 1x3.43 1x1.28 IE3 4 380V/3Ph/60Hz 8c. 9

.
8c. 16-MEP BOH Utilities

2 FAHU-02 1931078 ADN04HGD5 1 1 3155 1500 1060 730 1938 2168 62 FOAM Precoated 1 mm Precoated 1.2 mm Aluminium Natural Thermal Break YES 6120 1 SYQ315-K 548 1253 10.4 2935 4000 3.03 AC 1x4 1x7.4 1x3.69 IE3 2 380V/3Ph/60Hz
. 4GYM 8 b. GENSET
16-MEP BOH Utilities

DT
11.25

3
11.25m
DT 3

GENSET 90m ST

3
EXERCISING POOL 90m ST

3
11.25

3
11.25m 3

500m GENSET GENSET

DT
²
DT

8c. 90m ST

3
11.25

3
GENSET GENSET

DT
11.25m
DT 3

9 90m ST

3
4 inch Supply Header
.

DT
11.25

3
11.25m
DT 3

GENSET GENSET
90m ST

3
11.25

3
11.25m 3

GENSET GENSET

DT
90m ST

3
DT

8c. .9 Duplex
GPMGearPump 90m ST

3
SUPPLY AIR INLETS DX COIL SUPPLY PRIMARY FILTER SUPPLY SECONDARY FILTER ELECTRIC HEATER
GENSET GENSET

100
DT
BUILDING
11.25

3
11.25m
DT 3

6CLINIC 90m ST

3
11.25

3
11.25m 3

GENSET GENSET

DT
DT

90m ST

3
11.25

3
GENSET GENSET

DT
90m ST

3
11.25m
DT 3

DT
90m ST

3
11.25

3
11.25m
DT 3

GENSET GENSET
90m ST

4
11.25

3
11.25m 3

GENSET GENSET

inch Filling Header


DT
DT

90m ST

3
GENSET GENSET

DT
. 2FOOD COURT
11.25

3
11.25m
DT

3
90m ST

3
NO Inlet 1 Type Inlet 1 Mat. Inlet 1 Mounting Inlet 1 Dim. Inlet 1 Press. Drop Function Model Row No Fin space Fin Material Total Capacity Sensible Capacity Air Velocity APD EDB EWB LDB LWB Fluid Evap. Temp. Fluid Volume Face Velocity Type Model Grade QTYxDIM3 QTYxDIM5 Press. Drop Selection Type Model Grade QTYxDIM3 QTYxDIM5 Press. Drop Selection Step No Air On Temp. Air Off Temp. Power Electrical Connection
. MOSQUE 640sqm

DT
90m ST Filling Cabinet

3
11.25

3
11.25m

3
GENSET GENSET DT

Duplex Gear Pump


200GPM

Pa mm kW kW m/s Pa °C °C °C °C °C dm3 m/s DB°C DB°C kW


E
33 SCHOOL

.
1 DAMPER Aluminium EXTERNAL LEFT 660 x 880 5 COOL 1022P1908066020EO108 8 2 ALPR 0.1 mm 27.8 20.5 2.23 158 32.8 21.2 9.5 9.5 R410A 6 7.2 1.52 PLAN Chevronet ISO Coarse 60%(G4) 1x(490x592x48) 1x(287x592x48) MEDIUM SOFTBAG DriPak GX ePM1 65%(F7) 1x(490x592x510) 1x(287x592x510) MEDIUM 2 11.6 22 9 380V/3Ph/60Hz
2 DAMPER Aluminium EXTERNAL LEFT 790 x 1380 5 COOL 1022P2408111020EO1(9+10) 8 2 ALPR 0.1 mm 67.9 50.6 2.55 196 33.2 21.3 9.5 9.5 R410A 6 2 x 7.9 2.27 PLAN Chevronet ISO Coarse 60%(G4) 2x(490x592x48) 1x(287x592x48) MEDIUM SOFTBAG DriPak SX ePM2,5 65%(F7) 2x(490x592x390) 1x(287x592x390) MEDIUM 2 11.6 22 22 380V/3Ph/60Hz 33
SALON &FB-1&FB-2&FB-3

3 3 3

CAFE
G
01-000
106.58

m
²
3 3 3

Micro-mobilityCHARGING AREA

NEV Pick-up / Drop-off

OUT
Parking = 10

Micro-mobility eScooters Parking = 25 Micro-mobility eBikes Parking = 15

GATE OVERNIGHT
SHADED PARKING AREANEV
GENERAL PARKING ( 35 spaces ) PARKING (10 SPACES)
Fire Extinguisher

27 20 OUT OF SCOPE NEV SERVICE , CLEANING


A = ~1000 m2 & MAINTENANCE AREA

2
RIDE-HAILING STAGING(10
A ~ 300 m
CHARGING

IN
GENERAL PARKING (18 spaces)

DROP OFF(3
GENERAL PARKING (

SPACES)
CLUSTER

SPACES )
26 spaces ) Bus bays – Outdoor passenger waiting area

18- PARKING LOT


BUS 6 BUS 5
BUS 4

DROP OFF(3
GENERAL PARKING ( GENERAL PARKING (

SPACES)
19- Regional Transit Hub

EMERGENCY LANE
26 spaces ) 26 spaces )

BUS 1 BUS 2
BUS 3

ONLY BUS LANE

ONLY BUS LANE


LANE
CARSHARING ( 35 spaces )
Additional bus parking / overnight

EMERGENCY
parking area

VARIABLE REFRIGERANT VOLUME - INDOOR UNIT SCHEDULE


CONNECTED TO: SUPPLY FAN COOLING CAPACITY HEATING CAPACITY ELECTRICAL DIMENSIONS WEIGHT
BASIS OF ZONE Max
TAG ROOM DESIGN TYPE CHANGEOVER AIR FLOW RATE SENSIBLE ENTERING AIR TOTAL ENTERING AIR POWER SUPPLY Min Circuit Amps Overcurrent WxHxD Net
(DAIKIN) CONDENSING UNIT TOTAL kW Protection
DEVICE l/s kW kW °Cdb
°C DB °C WB Voltage - Phase MCA MOP mm kg

CASSTTE16-1-M.CHANG-G021-VRV03 MALE CHANGE FXFSQ32ARV1 Ceiling mounted cassette (Round flow) VRV03-ODU No 216.67 3.6 3.2 27.0 19.0 4.0 20.0 230V 1ph 0.3 16.0 840 x 256 x 840 19.0 NOTES:

CASSTTE15-2-M.BREAK-G020-VRV03 MALE BREAKOUT FXFSQ63ARV1 Ceiling mounted cassette (Round flow) VRV03-ODU No 391.67 7.1 6.0 27.0 19.0 8.0 20.0 230V 1ph 0.6 16.0 840 x 256 x 840 22.0
1. ALL MECHANICAL DRAWINGS SHALL BE READ IN CONJUNCTION WITH GENERAL NOTES,
SPECIFICATION, DETAILS AND ARCHITECTURAL, STRUCTURAL AND ELECTRICAL FINAL
CASSTTE13-2-F.BREAK-G019-VRV03 FEMALE BREAKOUT FXFSQ63ARV1 Ceiling mounted cassette (Round flow) VRV03-ODU No 391.67 7.1 6.0 27.0 19.0 8.0 20.0 230V 1ph 0.6 16.0 840 x 256 x 840 22.0
DESIGN DRAWING.
2. ALL DUCT SIZES MENTIONED ON PLANS ARE CLEAR SIZES, EXCLUDING THE THICKNESS OF
CASSTTE14-1-F.CHANG-G022-VRV03 FEMALE CHANGE FXFSQ32ARV1 Ceiling mounted cassette (Round flow) VRV03-ODU No 216.67 3.6 3.2 27.0 19.0 4.0 20.0 230V 1ph 0.3 16.0 840 x 256 x 840 19.0
INSULATION AND OTHER DUCT LINING.
CASSTTE17-3-F&B(1)-G028-VRV05 F&B (1) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV05-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0 3. UNLESS OTHERWISE INDICATED, ALL DIMENSIONS ARE IN MILLIMETERS.
4. ALL BOTTOM OF DUCT (BOD) ARE FROM FINISH FLOOR LEVEL (F.F.L.) UNLESS OTHERWISE
CASSTTE18-3-F&B(1)-G028-VRV05 F&B (1) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV05-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0 SPECIFIED.
5. DUCTWORK, FITTINGS, HANGERS AND ACCESSORIES SHALL BE AS PER SMACNA
CASSTTE19-3-F&B(1)-G028-VRV05 F&B (1) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV05-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0 RECOMMENDATIONS AND AS SPECIFIED IN THE SPECIFICATION AND APPROVED MATERIAL
SUBMITTAL.
CASSTTE20-3-F&B(1)-G028-VRV05 F&B (1) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV05-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0 6. ACCESS DOOR SHALL BE PROVIDED FOR ALL VD, FD, SMD, MVD,VALVES AND ALL
ELECTRICAL EQUIPMENT/COMPONENTS INSTALLED IN CONCEALED AREAS.
CASSTTE21-3-F&B(1)-G028-VRV05 F&B (1) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV05-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0 7. ALL DUCTWORKS TERMINATING WITH BELL MOUTHS SHALL BE PROVIDED WITH AN
INSECT SCREEN.
CASSTTE22-3-F&B(1)-G028-VRV05 F&B (1) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV05-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0 8. AIR OUTLETS SHOWN ON DRAWING ARE LISTED SIZES UNLESS OTHERWISE INDICATED,
FOR NECK AND FACE SIZE REFER TO MATERIAL SUBMITTAL MANUFACTURER'S MATERIAL
D CASSTTE23-3-F&B(2)-G029-VRV06 F&B (2) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV06-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0 CATALOGUE.
9. ALL MECHANICAL EQUIPMENTS SIZES SHOWN ON DRAWING ARE APPROXIMATE. FINAL
CASSTTE2-3--F&B(2)-G029-VRV06 F&B (2) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV06-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0 SIZES SHALL BE AS PER APPROVED MATERIAL SUBMITTAL EQUIPMENT SELECTION.
10. ACCESS PANEL SHALL BE PROVIDED FOR EACH AHU, FCU, FOR VALVES AND
CASSTTE25-3-F&B(2)-G029-VRV06 F&B (2) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV06-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0 MAINTENANCE.

CASSTTE26-3-F&B(2)-G029-VRV06 F&B (2) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV06-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0
CASSTTE27-3-F&B(2)-G029-VRV06 F&B (2) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV06-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0
CASSTTE28-3-F&B(2)-G029-VRV06 F&B (2) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV06-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0
CASSTTE29-3-F&B(3)-G030-VRV07 F&B (3) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV07-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0
CASSTTE30-3-F&B(3)-G030-VRV07 F&B (3) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV07-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0
CASSTTE31-3-F&B(3)-G030-VRV07 F&B (3) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV07-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0
CASSTTE32-3-F&B(3)-G030-VRV07 F&B (3) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV07-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0
CASSTTE33-3-F&B(3)-G030-VRV07 F&B (3) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV07-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0
CASSTTE34-3-F&B(3)-G030-VRV07 F&B (3) FXFSQ100ARV1 Ceiling mounted cassette (Round flow) VRV07-ODU No 558.33 11.2 9.0 27.0 19.0 12.5 20.0 230V 1ph 1.4 16.0 840 x 298 x 840 25.0
G00-004 TREATMENT RM-2 FXFSQ50ARV1 Ceiling mounted cassette (Round flow) VRV02-ODU No 383.33 5.6 5.0 27.0 19.0 6.3 20.0 230V 1ph 0.6 16.0 840 x 256 x 840 24.0
G00-001 MALE SERVICE FXFSQ80ARV1 Ceiling mounted cassette (Round flow) VRV02-ODU No 408.33 9.0 7.0 27.0 19.0 10.0 20.0 230V 1ph 1.0 16.0 840 x 256 x 840 22.0
G00-001 MALE SERVICE FXFSQ80ARV1 Ceiling mounted cassette (Round flow) VRV02-ODU No 408.33 9.0 7.0 27.0 19.0 10.0 20.0 230V 1ph 1.0 16.0 840 x 256 x 840 22.0
G00-011 TREATMENT RM-4 FXFSQ32ARV1 Ceiling mounted cassette (Round flow) VRV02-ODU No 216.67 3.6 3.2 27.0 19.0 4.0 20.0 230V 1ph 0.3 16.0 840 x 256 x 840 19.0
G00-008 TREATMENT RM-5 FXFSQ32ARV1 Ceiling mounted cassette (Round flow) VRV02-ODU No 216.67 3.6 3.2 27.0 19.0 4.0 20.0 230V 1ph 0.3 16.0 840 x 256 x 840 19.0
G00-009 TREATMENT RM-3 FXFSQ32ARV1 Ceiling mounted cassette (Round flow) VRV02-ODU No 216.67 3.6 3.2 27.0 19.0 4.0 20.0 230V 1ph 0.3 16.0 840 x 256 x 840 19.0
G00-007 STAFF ROOM FXFSQ50ARV1 Ceiling mounted cassette (Round flow) VRV02-ODU No 383.33 5.6 5.0 27.0 19.0 6.3 20.0 230V 1ph 0.6 16.0 840 x 256 x 840 24.0
G00-000 RECEPTION FXFSQ63ARV1 Ceiling mounted cassette (Round flow) VRV02-ODU No 391.67 7.1 6.0 27.0 19.0 8.0 20.0 230V 1ph 0.6 16.0 840 x 256 x 840 22.0
G00-010 TREATMENT RM-6 FXFSQ32ARV1 Ceiling mounted cassette (Round flow) VRV02-ODU No 216.67 3.6 3.2 27.0 19.0 4.0 20.0 230V 1ph 0.3 16.0 840 x 256 x 840 19.0
C
G00-002 FEMALE SERVICE FXFSQ80ARV1 Ceiling mounted cassette (Round flow) VRV02-ODU No 408.33 9.0 7.0 27.0 19.0 10.0 20.0 230V 1ph 1.0 16.0 840 x 256 x 840 22.0
G00-002 FEMALE SERVICE FXFSQ80ARV1 Ceiling mounted cassette (Round flow) VRV02-ODU No 408.33 9.0 7.0 27.0 19.0 10.0 20.0 230V 1ph 1.0 16.0 840 x 256 x 840 22.0
G00-003 TREATMENT RM-1 FXFSQ50ARV1 Ceiling mounted cassette (Round flow) VRV02-ODU No 383.33 5.6 5.0 27.0 19.0 6.3 20.0 230V 1ph 0.6 16.0 840 x 256 x 840 24.0

REFERENCE NUMBER DESCRIPTION


VARIABLE REFRIGERANT VOLUME - AIR-COOLED CONDENSING UNIT SCHEDULE
ELECTRICAL
COOLING CAPACITY HEATING CAPACITY REFRIGERANT CHARGE MAX OVERCURRENT DIMENSIONS
BASIS OF CONNECTION MIN CIRCUIT RUNNING
PROTECTION (MOP) FREQ PI
TAG: ROOM DESIGN DESCRIPTION RATIO VOLTAGE- AMPS (MCA) CURRENT(RLA)
(DAIKIN) AMBIENT DESIGN (%)

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF NEOM. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT FROM NEOM.
PHASE (WxHxD) WEIGHT
kW AMBIENT DESIGN (°C DB) kW (°C DB / Factory Charge (kg) Add'l Refrigerant (kg) mod #1 mod #2 mod #3 total mod #1 mod #2 mod #3 total mod #1 mod #2 mod #3 total Hz kW
(mm) (kg)
WB)
STAGE:
3D TENDERING STAGE & IFC
VRV03-ODU RXYTQ10U5YF Air cooled heat pump (1) 24.9 43.9 22.9 0.0 / -0.7 10.3 2.0 75.0 400V 3Nph 22.0 22.0 25.0 25.0 9.3 9.3 60 7.2 1,240 x 1,685 x 765 244.0
VRV05-ODU RXYTQ28U5YF Air cooled heat pump (2) 60.8 43.9 60.4 0.0 / -0.7 22.2 14.7 85.7 400V 3Nph 31.0 24.0 55.0 40.0 32.0 72.0 19.3 12.7 32.0 60 23.2 1,240 x 1,685 x 765 / 1,240 x 1,685 x 765 299.0 / 244.0
VRV06-ODU RXYTQ28U5YF Air cooled heat pump (2) 62.3 43.9 60.9 0.0 / -0.7 22.2 11.7 85.7 400V 3Nph 31.0 24.0 55.0 40.0 32.0 72.0 19.3 12.7 32.0 60 23.2 1,240 x 1,685 x 765 / 1,240 x 1,685 x 765 299.0 / 244.0
VRV07-ODU RXYTQ28U5YF Air cooled heat pump (2) 63.5 43.9 61.3 0.0 / -0.7 22.2 9.1 85.7 400V 3Nph 31.0 24.0 55.0 40.0 32.0 72.0 19.3 12.7 32.0 60 23.2 1,240 x 1,685 x 765 / 1,240 x 1,685 x 765 299.0 / 244.0 A 3D-TENDERING STAGE & IFC EH 21-09-2024
VRV02-ODU RXYTQ32U5YF Air cooled heat pump (2) 72.0 43.9 70.4 0.0 / -0.7 23.6 9.4 82.2 400V 3Nph 31.0 31.0 62.0 40.0 40.0 80.0 19.3 19.3 38.6 60 27.4 1,240 x 1,685 x 765 / 1,240 x 1,685 x 765 299.0 / 299.0 REV DESCRIPTION APP DATE
PURPOSE OF ISSUE:

FOR APPROVAL
CLIENT: PROJECT MANAGEMENT CONSULTANT:
C:\Users\engeh\Desktop\30 COFFEE SHOP+SALON+F&B\02 SALON\01-SALON-HVAC-3D\01 RVT\03-408301-4800000882-FHD-MEC-3DM-000001-SALON-3D.rvt

B VARIABLE REFRIGERANT VOLUME - AIR-COOLED CONDENSING UNIT SCHEDULE


ELECTRICAL
COOLING CAPACITY HEATING CAPACITY REFRIGERANT CHARGE MAX OVERCURRENT DIMENSIONS
BASIS OF CONNECTION MIN CIRCUIT RUNNING
PROTECTION (MOP) FREQ PI
TAG: ROOM DESIGN DESCRIPTION RATIO VOLTAGE- AMPS (MCA) CURRENT(RLA)
(DAIKIN) AMBIENT DESIGN (%) PHASE (WxHxD) WEIGHT
kW AMBIENT DESIGN (°C DB) kW (°C Factory Charge (kg) Add'l Refrigerant (kg) mod #1 mod #2 mod #3 total mod #1 mod #2 mod #3 total mod #1 mod #2 mod #3 total Hz kW
(mm) (kg)
DB / WB)
DESIGN CONSULTANT NAME & LOGO (s): CONTRACTOR NAME & LOGO (s):

CU-FAHU-01 RXQ12ARYFK Air cooled cooling only (1) 29.8 43.9 0.0 0.0 / -0.7 9.3 0.6 83.3 400V 3Nph 26.9 26.9 0.0 0.0 60 9.5 1,240 x 1,657 x 765 220.0
CU-FAHU-02 RXQ28ANRYFK Air cooled cooling only (2) 68.3 43.9 0.0 0.0 / -0.7 21.1 3.5 85.7 400V 3Nph 38.9 26.9 65.8 0.0 0.0 60 22.7 1,240 x 1,657 x 765 / 1,240 x 1,657 x 765 285.0 / 220.0

DESIGN CONSULTANT / CONTRACTOR: NEOM'S REVIEW:


DRAWN: AL-FAHD 19/09/204
CHECKED: AL-FAHD 20/09/204 CHECKED: NEOM
APPROVED: AL-FAHD 21/09/204 APPROVED: NEOM

SCALE: NTS SHEET SIZE: A0


DISCIPLINE NAME:
MECHANICAL-HVAC
SALON &FB-1&FB-2&FB-3

HVAC EQUIPMENT SCHEDULE


PROJECT NAME:

A SOUTH BUSNIESS COMMUNITY EXPANTION

NEOM COMMUNITY EXPANSION


NEOM
KINGDOM OF SAUDI ARABIA
REGION ASSET CODE CONTRACT CODE

03 408301 4800000882
9/22/2024 4:49:19 AM

DRAWING NUMBER

ORIGINATOR DISCIPLINE DOCUMENT TYPE SEQUENTIAL NUMBER REV NO.

FHD MEC DRG 600003 A


NEOM-NEN-PRC-009_TMP12_02.00