MOUNTING SCREW AND SHIELD

CASHIER
LOCK NUT
IMPELLER GONG SHELL
BODY BACK PLATE ASSY.
GASKET
COVER SHEET LOCK WASHER
KEY WRENCH
MACHINE SCREW ACCORDION NUT COVER TAPE FOR SWITCH ACTUATOR LEVER
WASHER (OPTIONAL)
FLANGE BUSHING RETARD ADJUSTMENT COVER
DUAL SWITCH DIAL
STRIKER ASSEMBLY
CAP SCREW
COVER SCREW
ACTUATOR COLLAR
STRIKER SHAFT BUSHING
WASHERS
SUMP SLUG 12 MM CONDUIT HOLE SADDLE
STRIKER SHAFT SADDLE SPRING
ORIFICE BUSHING RESET SPRING
DRIVE SHAFT
LABEL SADDLE GASKET
CONNECTING NIPPLE
IMPELLER SHAFT BUSHING MOUNTING PLATE
SECTIONAL ELEVATION VANE GASKET T-BOLT
DRAIN TO NEAREST LOCATOR
SUMP OR CATCH BASIN

ARM
AL
IF VANE

BELL
EXTERIOR SIGN
RINGS
CALL
B E LL FIRE DEPT.
DETAIL OF WATER FLOW SWITCH MOUNTING DETAIL OF PORTABLE
ELEVATION FIRE EXTINGUISHER
DETAIL OF ALARM GONG
DETAIL OF FIRE DEPT. CONNECTION

UPRIGHT TYPE FLOOR SLAB


SPRINKLER HEAD

BEAM/
OBSTRUCTION
0.00 LESS THAN 0.3M 0.00M
MAXIMUM DISTANCE BEAM OR 0.30 TO LESS THAN 0.6M 0.02M
DEFLECTOR ABOVE OBSTRUCTION SUPERVISORY
BOTTOM OF BEAM 0.60 TO LESS THAN 0.76M 0.05M CROSSMAIN 65mm dia.
NOT TO EXCEED B.I. SCHED. 40 SWITCH 75mm dia.
MAX. SPECIFIED 0.76 TO LESS THAN 0.91M 0.08M
FOR TYPES OF
CONSTRUCTION 0.91 TO LESS THAN 1.10M 0.10M

1.10 TO LESS THAN 1.22M 0.15M OS & Y GATE VALVE


DRY STAND PIPE 100mm dia. WATER FLOW SWITCH 75mm dia.
RISING TYPE & FLANGE TYPE
1.22 TO LESS THAN 1.37M 0.18M
75mm dia. BUTT WELD.
1.37 TO LESS THAN 1.52M 0.23M 'W' x 'T'
UNISTRUT VERTICAL
PROVIDE PIPE
SLEEVES
1.52 TO LESS THAN 1.70M 0.28M 100mm dia.x 65mm dia. FEEDMAIN PIPE 75mm dia. PIPE CLAMP OR
DISTANCE FROM NEAR WALL
SIDE OF BOTTOM 1.70 TO LESS THAN 1.80M 0.36M FIRE HOSE VALVE W/ 100MM dia. AFSS RISER APPROVED EQUAL
BRANCH LINE CAP & CHAIN
MOUNTING DETAIL OF SPRINKLER HEAD
WITH RESPECT TO OBSTRUCTION
100 dia. DRY STAND PIPE FLANGED CONNECTION

VICTAULIC COUPLING
BRANCH LINE

FINISH FLOOR LINE


RISER NIPPLE
100MM
LONG NIPPLE
VICTAULIC COUPLING

INSPECTOR
TEST VALVE
DETAIL OF FIRE HOSE VALVE 25 MM dia. SIGHT GLASS CAP CROSSMAIN
VARIES SIZES OF HAND-
HOSE CONNECTION LINE:
32mm dia. AUXILLARY
SCHEDULE:
25 dia.: 6m & below
DRAIN PIPE
100mm dia. AFSS RISER
DETAIL OF FLUSHING CONNECTION
32 dia.: 7m & above
40 dia.: 25m & above
40mm. ANGLE VALVE
WITH COMBINATION 40 dia. ANGLE VALVE
TYPE RESTRICTING
BRASS POLISHED
ANGLE VALVE AT FLR. FIRE FOG ADJUSTABLE
LVL W/ EXCEEDING HOSE NOZZLE
DOWNSTREAM PRESSURE
OF 100 PSI ADJUSTIBLE
BOTTOM OF BEAM DETAIL OF FLOOR CONTROL VALVE
6MM.THK. ANGULAR BAR
PRESSURE RESTRICTING
ANGLE VALVE SHOULD 40 mm dia.x 30.00 long
U-BOLT W/ NUTS & WASHERS
BE POTTER-ROEMER RUBBER LINE COTTON FIRE
MODEL-4080-4085 HOSE JACKETED W/ CHROME
OR EQUAL PIN LUG COUPLING THREAD LATERAL BRACE HORIZONTAL PIPE (VER. SIZE)
15MM X 50MM BOLTS & NUTS SPRINKLER RISER CLAMP
W/ LOCKNUTS & WASHER
ALUMINUM TRIM
HORIZONTAL PIPE (VER. SIZE) SPRINKLER RISER
8MM X 50MM X 50MM ANGLE BAR
10 LBS DRY CHEMICAL
TYPE ABC PORTABLE U-BOLT W/ NUTS & WASHERS
FIRE EXTINGUISHER 15MM X 22.5MM BOLTS & NUTS 15MM X 22.5MM BOLTS & NUTS
W/ LOCKNUTS & WASHER W/ LOCKNUTS & WASHER
PULL FLUSH MOUNTING DOOR 6MM.THK. ANGULAR BAR
WITH TRIM FOR ALL GLASS
PLATE SHALL BE GAUGE #18
VICTAULIC COUPLING PIPE SLEEVES VICTAULIC COUPLING
PIPE PIPE

CHB / CONCRETE

MOUNTING DETAIL OF PIPE DETAIL OF RISER SWAY BRACE


DETAIL OF FIRE HOSE CABINET DETAIL OF SWAY BRACING
PASSING THRU/CONCRETE WALL