UF MEMBRANE DATA SHEET – 100 KD
SPECIFICATION UNIT 225 MM DIA
UF MEMBRANE TYPE
Material Modified Polyether Sulphone
Type Capillary Multi bore
Flow IN to OUT
Capillary per fibre Nos 7
fiber OD Mm 4
Capillary ID Mm 0.8
MWCO KD 100
Active Surface Area m2 65
Hydrophilic or Hydrophobic Hydrophilic
Chlorine Resistance
Normal 2 to 3 ppm
Instantaneous 200 ppm for short duration
Max. 200,000 ppm hrs
UF OPERATIONAL DATA 1
Operating Temperature o C 15 – 45
Mode of operation
Q.NO: MHT/MKTG/ME- 10115R1/2024-25 Dated 22.05.2024
`
TEAM
UF MEMBRANE DATA SHEET – 100 KD
UF PERMEATE QUALITY
SDI <3
Turbidity < 0.5 NTU
Note : * Operation Philosophy & CEB / CIP timings and frequency may vary based on fluctuations in
feed water quality.
2
Q.NO: MHT/MKTG/ME- 10115R1/2024-25 Dated 22.05.2024
`
TEAM
DISCLAIMER
• Pressure required at the inlet of Backwash skid main header should be minimum - 2 kg / cm2
• Dosing pump capacity shall be in excess of 20 % over the chemical flow rate as mentioned in the
above Table.
• MHT shall not be responsible for any deterioration in the quality of UF permeate due to chemical
Precipitation.
• The Cycle Timings mentioned above “Operation Philosophy” table are liable to change in accordance
to feed water Characteristics.
• Operation shall be through PLC automation with adjustable timer provision in order to change the
operation sequence to suit field condition.
• RO permeate or soft water is to be used for CEB / CIP in case of high hardness feed water.