Data Sheet - 100KD - 65m2 - De-Ion Systems - 10115R1

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Q.NO: MHT/MKTG/ME- 10115R1/2024-25 Dated 22.05.

2024
`
TEAM
UF MEMBRANE DATA SHEET – 100 KD
SPECIFICATION UNIT 225 MM DIA

ULTRA FILTRATION SKID


No. of Membrane per Skid No. 2
No. of Skids / Stream No. 1
No of Streams No. 1
PROCESS PUMP DETAILS
Feed Pump Capacity m3/hr 7.5
Backwash Pump Capacity m3/hr 22
Forward flush Pump Same UF feed pump shall be used.
CIP Pump Same UF feed pump shall be used.
Feed Pump - MOC SS 316
Backwash Pump - MOC SS 316
ULTRAFILTRATION PLANT CAPACITY
Feed Flow m3/hr 6.7
Permeate Flow m3/hr 6
Recovery Rate % 90
Design Flux LMH 46
Backwash Flux LMH 170
UF MEMBRANE SPECIFICATION
Model No RDMT-EM-65XVI-MBM–100KD (3 - Ports)
Housing OD Mm 225
Housing Length Mm 1830 + 2.0
Length with End Block Mm 2040 + 5.0
Housing Material UPVC
End Cap Material PPGF
Feed / Permeate Inch 2 " Victaulic
Backwash IN / Out Inch 2 " Victaulic
Membrane Area / Element m2 65
Total No. of Modules Nos. 2
Total Area of Membranes m2 130
Empty Weight with End Block Kg 34
Frontal Pipes & Manifolds UPVC
CHEMICAL DOSING PUMP CAPACITY
HCl Dosing Pump LPH 0 – 35
Caustic Dosing Pump LPH 0 – 25

UF MEMBRANE TYPE
Material Modified Polyether Sulphone
Type Capillary Multi bore
Flow IN to OUT
Capillary per fibre Nos 7
fiber OD Mm 4
Capillary ID Mm 0.8
MWCO KD 100
Active Surface Area m2 65
Hydrophilic or Hydrophobic Hydrophilic
Chlorine Resistance
Normal 2 to 3 ppm
Instantaneous 200 ppm for short duration
Max. 200,000 ppm hrs

UF OPERATIONAL DATA 1
Operating Temperature o C 15 – 45
Mode of operation
Q.NO: MHT/MKTG/ME- 10115R1/2024-25 Dated 22.05.2024
`
TEAM
UF MEMBRANE DATA SHEET – 100 KD

UF MEMBRANE OPERATING PRESSURE CONDITIONS


Feed Pressure (Maximum) Kg/cm2 2.5
Backwash pressure (Maximum) Kg/cm2 2.5
Trans Membrane Pressure (Maximum) Kg/cm2 1 to 1.4
UF OPERATION PHILIOSOPHY*
Filtration Time Min 20 - 30 min*
Forward Flush - A Duration Sec 15 - 45 sec*
Backwash duration Sec 30 - 60 sec*
Forward Flush - B Duration Sec 15 - 45 sec*

CHEMICAL CLEANING DATA Chemical Dosing Rate % Conc, Frequency


Caustic 500 ppm 45
CIP Cleaning Twice in a Month*
HCL 500 ppm 33
Caustic 500 ppm 45
CEB – Cleaning Twice in a Week*
HCL 500 ppm 33
Chemical dosing level to be set on the backwash flow rate
CEB Operating Data
Chemical Dosing Time
(Caustic - pH – 12 to 13) 2 - 5 Minutes*
(HCL – pH – 3 to 4)
Soaking time 10 – 20 Minutes*
After Soaking, Backwash with permeate
2 - 3 minutes*
water
After the above CEB process take UF System in service mode ensure neutral pH
CIP Operating Data
CIP Chemicals Caustic / HCL
Chemical Circulation 10 – 20 Minutes*
Soaking time 10 – 20 Minutes*
After Soaking , Backwash with permeate
2 - 3 minutes*
water
After the above CIP process take UF System in service mode ensure neutral pH
In case of heavy bio fouling add 20 – 50 ppm Hypo in the CIP tank.

UF FEED WATER QUALITY


pH < 6.8 - 7.5
TSS < 10 ppm
Turbidity < 10 NTU
COD < 70 ppm
BOD < 20 ppm
Oil & Grease NIL
Iron < 0.3 ppm

UF PERMEATE QUALITY
SDI <3
Turbidity < 0.5 NTU

Note : * Operation Philosophy & CEB / CIP timings and frequency may vary based on fluctuations in
feed water quality.

• Minimum 1 ppm of residual free chlorine to be maintained in UF Feed water.

2
Q.NO: MHT/MKTG/ME- 10115R1/2024-25 Dated 22.05.2024
`
TEAM
DISCLAIMER

• Pressure required at the inlet of Backwash skid main header should be minimum - 2 kg / cm2
• Dosing pump capacity shall be in excess of 20 % over the chemical flow rate as mentioned in the
above Table.
• MHT shall not be responsible for any deterioration in the quality of UF permeate due to chemical
Precipitation.
• The Cycle Timings mentioned above “Operation Philosophy” table are liable to change in accordance
to feed water Characteristics.
• Operation shall be through PLC automation with adjustable timer provision in order to change the
operation sequence to suit field condition.
• RO permeate or soft water is to be used for CEB / CIP in case of high hardness feed water.