Power Optimizer: Solaredge'S Most Advanced, Cost
Power Optimizer: Solaredge'S Most Advanced, Cost
Power Optimizer
S1200
25
YEAR
WARRANTY
solaredge.com
Power Optimizer
S1200
S1200 Unit
INPUT
Rated Input DC Power(1) 1200 W
Absolute Maximum Input Voltage (Voc) 125 Vdc
MPPT Operating Range 12.5 – 105 Vdc
Maximum Short Circuit Current (Isc) of connected PV Module 15 Adc
Maximum Efficiency 99.5 %
Weighted Efficiency 98.8 %
Overvoltage Category II
OUTPUT DURING OPERATION
Maximum Output Current 20 Adc
Maximum Output Voltage 80 Vdc
(1) Rated power of the module at STC will not exceed the Power Optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed.
(2) For other connector types please contact SolarEdge.
(3) For S-Series models with long input cables (1.6m / 5.24ft), the Sense Connect feature is only enabled on the output cable connector.
(4) Option 1 fits best when modules are placed in landscape orientation or in portrait orientation with the power optimizers connected using the leapfrog wiring method.
Option 2 fits best when modules are placed in portrait orientation.
(5) For ambient temperatures above +65°C / +149°F power de-rating is applied.
230/400V Grid
PV System Design Using a SolarEdge 230/400V Grid 230/400V Grid 230/400V Grid 277/480V Grid
SE16K, SE17K,
Inverter(6)(7)(8)(9) SE27.6K* SE30K* SE33.3K* SE40K*
SE25K*
Compatible Power Optimizers S1200
Power Optimizers 14 14 15 14 15
Minimum String Length
PV Modules 27 27 29 27 29
Power Optimizers 30 30 30 30 30
Maximum String Length
PV Modules 60 60 60 60 60
Maximum Continuous Power per String 15000 15500 17000 15000 17000
1 string – 17250 1 string – 17750 1 string – 19250 1-2 strings – 17250 1-2 strings – 19250
Maximum Allowed Connected Power per String(9) 2 strings or more – 2 strings or more – 2 strings or more – 3 strings or more – 3 strings or more –
20000 20500 23000 20000 23000
Parallel Strings of Different Lengths or Orientations Yes
Maximum Difference in Number of Power Optimizers
Allowed Between the Shortest and Longest String 5 Power Optimizers
Connected to the Same Inverter Unit
* The same rules apply for Synergy units of equivalent power ratings, that are part of the modular Synergy Technology inverter.
(6) S1200 cannot be mixed with any other Power Optimizers models in the same string.
(7) For each string, a Power Optimizer may be connected to a single PV module if 1) each Power Optimizer is connected to a single PV module or 2) it is the only Power Optimizer connected
to a single PV module in the string.
(8) For SE16K and above, the minimum STC DC connected power should be 11KW.
(9) To connect more STC power per string, design your project using SolarEdge Designer.
© SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc.
All other trademarks mentioned herein are trademarks of their respective owners. Date: September 14, 2022 DS-000122-ROW. Subject to change without notice.