NDERGROUND SINGLE POLE CUTOUTS DIN TYPE BUSBAR DISTRIBUTION UNITS AND LOAD CENTERS 11 kV GANG OPERATED AIR BREAK SWITCHES
ASIATIC
The Cutouts are designed for 60/80/100A rating The product finds its application for protection of DIN Type TP Bus Bar Distribution Units are most
IN PORCELAIN & SILICONE RUBBER INSULATORS
with SP, SPN & TPN configurations complying with overhead/underground lines and serves to disconnect compact, convenient and reliable option of
BS 7657:1993 and ESI 12-10. a section of network during fault. Designed to BS 7656 distributing electrical energy. They find many
The Cutout housing is of DMC with a quality finish from & BS 88, the cutout is moulded in DMC compression applications in domestic as well as industrial circles
modern moulding tools thereby ensuring accuracy of moulding having high mechanical strength, is flame
retardant and provides excellent all round
i.e. Distribution boards, load centers and feeder
pillars etc. The product is designed for 200A, 3 phase
ELECTRICAL & SWITCHGEAR P. LTD.
various parts for interchangeability. The design and
construction of the cutout ensures high mechanical and impact strength ideally suited for outdoor/indoor power system complying with IEC:60439-1. Due
di-electric strength. The fuse carriers are designed for applications. Top cover is removable for ease of to its compact design, the overall dimensions of
standard BS 88/BS 1361 fuse links with standard copper installation and cabling. It is suitable for wedge type the distribution boards can be reduced to a great
contacts having uniform pressure to ensure effective fuse links to BS 88 with 82.5 mm fixing center. Robust extent. The unique design offers easy fitment of
contact with long service life. The Cutouts have been copper tinned contacts are designed to carry currents MCB’s directly on the bus bar systems coupled with
up to 300-400 amperes. A compact version of Pole din channels. The Gang Operated Air Break Switches are meant for outdoor application and are
type tested at KEMA Holland. suitable for horizontal or vertical mounting suitable for 11-33 kV 3 phase 4 wire
mounted cutout with same functionality is also available.
The product can also serve dual purpose of neutral link by network. They are designed for satisfactory performance in harsh atmospheric conditions of
connecting solid link of copper instead of fuse link. high/low temperatures & humidity. Their primary function is to isolate a line and are
available in single pole & three pole versions with 2 or 3 insulators per pole. Copper
STREET LIGHTING CUTOUTS BS TYPE VERTICAL FUSE WAYS UPTO 630A 11-36 kV, 100A EXPULSION FUSE CUTOUTS contacts are made of ETP grade high conductivity copper and are spring loaded for adequate
IN PORCELAIN & SILICONE RUBBER INSULATORS contact pressure. All MS parts and hardware are duly hot dip galvanized as per standard
Asiatic’s range of Street Lighting Cutouts are designed LV HRC Fuse ways to BS standards can be combined to specifications which imparts long life to the switch.
to meet BS 7654 and are designed for use by Electricity form distribution systems having desired number of The Expulsion Fuse Cutouts offer reliable mechanism for providing circuit protection in arial The air Break Switches in Silicone Rubber Insulators which have distinct advantages over
authorities. Manufactured in DMC, they are available in electrical circuits. The design is vertical with copper distribution systems for voltages ranging from 11 kV to 36 kV. It is designed to be installed conventional Porcelain Insulators. The Air Break Switches are available in current rating of 200,
two variants: contacts mounted on non-hygroscopic bakelite supports outdoors for vertical cross arm or pole mounting. An all copper current path is designed to 400 & 630A and have been type tested from CPRI India as per IS 9921 (part‑4) : 1985 and
Type-A: and suitable for accommodating fuse links of 82.5 or ensure efficient current flow. All contacts are in ETP grade copper and silver plated. IEC 62271-102
92 mm fixing centers as per BS 88. The fuse ways can be
Suitable for accepting one incoming & one outgoing- The heart center of the cutout is the fuse tube holder which has clearly distinguished outer
designed as per individual customer requirements.
two core cable. layer of fibre glass and inner layer of bone liner which effectively extinguishes the arc. SURGE ARRESTORS
The outer layer of the fuse tube has been given a layer of UV resistant paint to protect it
Type-B:
against the deteriorating effects of the UV rays. The Surge Arrestors are an indispensable
Suitable for accepting one incoming & one outgoing- protection devise needed to protect a transformer
Our range of expulsion fuse cutouts have been type tested at KEMA Holland & CPRI - India
four core cable. The cutouts accept tag type fuse links against natural lightning & switching surges in
as per IEC 60282-2.
from 2A to 25A. a high voltage networks. They are designed for
satisfactory performance in harsh atmospheric
conditions of high/low temperatures & humid-
ity. Asiatic offers the latest gap less metal oxide
HEAVY DUTY CUTOUTS IN CAST ALUMINUM/SHEET METAL/ FUSE CARRIERS WEDGE TYPE technology which is far superior to conventional
DMC HOUSING systems being used previously. Surge Arrestors
Our standard range of fuse carriers are made from DMC which has high impact & di-electric strength are available in rated voltages of 3-36 kV with
Asiatic’s has a wide range of Heavy Duty Cutouts in and are suitable for BS-88 HRC fuse links. The Fuse Carriers are available in 82.5 & 92 mm fixing centers discharge currents ranging from 5 -10 kA.
cast aluminum & sheet metal housing and DMC in Finger grip, and Through grip options. The fuse carriers are also available in porcelain with 82.5 mm
The Surge Arrestor in silicone rubber are compara-
housing. Various configurations are available as per fixing centers. The expulsion fuse cutouts with Silicone base insulators are compact, light weight and robust tively light weight & un-breakable, hydro phobic,
BS/DIN standards as per individual customer enough to withstand shocks due to frequent operation. Silicone rubber insulators offer distinct resistant to UV rays, chemicals, ozone & offers
requirements. The Cutouts are designed for indoor or advantages over its porcelain counterpart in terms of the following: excellent resistance to aging.
outdoor applications as per requirements.
• The insulators are light weight and as • Impact & vandal resistant. Un-breakable &
much as 30% lighter than their porcelain hence reduces the risk of transport damages. COMPOSITE INSULATORS
counterparts. • High surface resistance limits
• They have ability to achieve higher leakage currents & hence higher pollution Asiatic offers a wide range of Composite/Line
creepage distances in the given length. withstand. Insulators in Silicone Rubber with host of end
• Hydrophobic & hence high pollution • Highly resistive to Ozone & UV radiations. A LTL HOLDINGS
fittings to exact requirements of the customers GROUP COMPANY
resistance. • Resistant to earthquake shocks. from 11 - 36 kV. We are also manufacturing
• Fire retardant Composite Insulators for Indian Railways.