POWER SYSTEMS 2

MODULE-2
3 MARKS
2022-JULY
1. Explain the terms with respect to Gauss Siedel method a) Acceleration factor b)
Convergence criteria c) Handling of PV buses.
2. State the static load flow problem.

2023-MAY

1. Explain how buses in a power system are classified?


2. Explain the principle of DC load flow.

2023-JUNE

1. Explain how are buses classified.


2. A power system network has 100 buses. The Y-Bus matrix is 90 % sparse. Determine
the number of transmission lines in the system

2024-JANUARY

1. Find the Y-Bus for the transmission line data given below

2. How slack bus differs from other buses in a power system? What is the significance of
slack bus in load flow analysis?
14 MARKS

2022-JULY
13. a) Consider the one line diagram of a power system as shown in Fig.l.Line (10)
impedances are marked in per unit on a 100MVA base. Obtain the load flow solution
using Gauss Siedel method. (REPEATED)

b) Write a brief note on fast decoupled load flow.


14. a) Derive the Newton Raphson power flow analysis algorithm and gives steps for
implementation of the algorithm.
b) What are the operating constraints in load flow analysis?

2023-MAY

13 a) An incomplete nodal admittance matrix for a 4 bus system is given. Find the missing
terms.

b) What is Jacobian matrix? How the elements of Jacobian matrix are computed? What are
the advantages and disadvantages of Newton-Raphson method?

14 a) Obtain the load flow solution at the end of first iteration of the system. The solution is
to be obtained for the following cases:
i) All buses except bus 1 are PQ buses
ii) ii) Bus 2 is a PV bus whose voltage magnitude is specified as 1.04.
iii) iii) Bus 2 is a PV bus with voltage magnitude is specified as 1.04 and 0.25≤ 𝑄2 ≤
0.8𝑝u

2023-JUNE

13) For the system shown, obtain the power flow solution by Fast Decoupled Load flow.
The voltage at bus 1 is adjusted to 1.05 p.u. Voltage magnitude at bus 3 is fixed at 1.04
p.u. with real power generation of 200MW. A load consisting of 400MW and
250MVAR is taken from bus 2. Line impedances are marked in per unit on a 100MVA
base and line susceptances are neglected. (REPEATED TWICE)
b) What is a Jacobian Matrix? How are the elements of the Jacobian matrix computed?

14) The following is the system data for a load flow solution. The line admittances are:

The schedule of active and reactive powers:

Using Gauss Seidel Method, determine the voltages, starting with a flat voltage profile
and assuming accelerating factor as 1.6

2024- JANUARY

13) The following is the system data for a load flow solution. The line admittances are:

The schedule of active and reactive powers:


The reactive power constraint at bus 2 is 0.1 ≤ Q2 1.0. Using Gauss Seidel Method,
determine the voltages, starting with a flat voltage profile and assuming accelerating
factor as 1.0

14) Draw and explain flowchart and algorithm of Newton- Raphson Load Flow
Analysis. Give a comparison of Newton- Raphson Method with respect to Gauss -
Seidel and Fast Decoupled Load Flow Methods.