Theoretical Calibration of a Centrifuge Tube and Volumetric Flask

Introduction:

Calibration of laboratory glassware is critical to obtaining accurate volumetric measurements.


Appropriate calibration establishes a known relationship between the actual volume of a container and
the volume indicated by the markings on it. The centrifuge tube and volumetric flask are commonly used
laboratory glassware with volumetric scales. The purpose of this report is to provide a theoretical basis
for the calibration of these instruments.

Centrifuge Tube Calibration:

A centrifuge tube typically contains graduations etched at equal intervals along its length, to enable the
measurement of liquid volume within it. Calibration is the process of determining the relation between
the actual volume of a flask and the volume indicated by the graduation marks on it.

The accuracy of centrifuge tubes is affected by manufacturing tolerances, such as the accuracy of the
gradations and the uniformity of the tube’s cross-section. The calibration of centrifuge tubes requires
reference standards such as a certified volume, high-quality balance or density measurement apparatus,
and distilled water. The volume of distilled water in each graduation can be calculated by weighing the
tube before and after adding the specific volume of water. The density of the water must first be
determined, typically by obtaining it from literature at a given temperature or by using a density
measurement apparatus.

Volumetric Flask Calibration:

Volumetric flasks are precision glassware with a single volume measurement marked on the neck of the
flask, at a fixed temperature typically at 20°C. The mark indicates the volume of water in the flask that
will produce a precise amount of the desired concentration when the solution is prepared.

Calibration of volumetric flasks involves the use of a certified volume, a density measurement
apparatus, and distilled water. Distilled water is added to the flask until the absolute temperature-
corrected meniscus is level with the mark, and the stopper is inserted to prevent evaporation or
contamination. Determination of the weight of the flask and its contents yields the density of the liquid.
The volume of water in the flask can be calculated based on the density of the water, weight of the flask,
and weight of the flask filled with water.

Conclusion:
Calibration of laboratory glassware is fundamental in the quantity determination of liquid volumes for
many scientific applications. Calibration of instruments, such as centrifuge tubes and volumetric flasks,
ensures accurate and reproducible results. Proper calibration procedures require the use of reliable
reference standards, such as certified volumes, high-quality balances and density measurement
instruments, and distilled water.

References:

1. ASTM E542-01 (2016), “Standard Practice for Calibration of Laboratory Volumetric Apparatus,” ASTM
International, West Conshohocken, PA.

2. Lide, D. R. (Ed.). (2021). CRC Handbook of Chemistry and Physics, 101st Edition. CRC Press.