Data sheet 6XV1850-2GH20

product description Patch cable, preferred length, preassembled with two RJ45 connectors
(10/100MB)
Industrial Ethernet TP Cord RJ45/RJ45, TP cord pre-assembled with 2 RJ45 plug,
length 2 m.

suitability for use Easy connection of terminal devices to the IE FC cabling system
cable designation LI 02YSCY 2x2x0,15/0,98 PIMF ICCS GN
wire length 2m
electrical data
number of electrical connections 2
attenuation factor per length
● at 10 MHz / maximum 0.09 dB/m
● at 100 MHz / maximum 0.285 dB/m
● at 300 MHz / maximum 0.495 dB/m
● at 600 MHz / maximum 0.75 dB/m
impedance
● at 1 MHz ... 100 MHz 100 Ω
● at 10 MHz … 600 MHz 100 Ω
relative symmetrical tolerance
● of the characteristic impedance at 1 MHz … 100 MHz 15 %
● of the characteristic impedance at 10 MHz … 600 MHz 6%
transfer impedance per length / at 10 MHz 10 mΩ/m
loop resistance per length / maximum 300 mΩ/m
insulation resistance coefficient 150 GΩ·m
operating voltage
● RMS value 80 V
mechanical data
number of electrical cores 4
design of the shield Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated
copper wires
core diameter
● of AWG26 insulated conductor 0.48 mm
outer diameter
● of inner conductor 0.48 mm
● of the wire insulation 0.98 mm
width / of cable sheath 5.8 mm
symmetrical tolerance of width / of cable sheath 0.2 mm
thickness / of cable sheath 3.7 mm
symmetrical tolerance of thickness / of cable sheath 0.2 mm
material
● of the wire insulation polyethylene (PE)
● of cable sheath PVC
color
● of the insulation of data wires white/blue, white/orange

6XV18502GH20 Subject to change without notice


11/11/2024
Page 1/3 © Copyright Siemens
● of cable sheath green
bending radius
● with single bend / minimum permissible 24 mm
● with multiple bends / minimum permissible 42 mm
weight per length 32 kg/km
ambient conditions
ambient temperature
● during operation -40 ... +70 °C
● during storage -40 ... +70 °C
● during transport -40 ... +70 °C
● during installation -40 ... +70 °C
fire behavior flame resistant according to IEC 60332-2-1
chemical resistance
● to mineral oil oil resistant according to IEC 60811-2-1 (4 h / 70°C)
● to grease Conditional resistance
protection class IP IP20
product features, product functions, product components / general
product feature
● halogen-free No
● silicon-free Yes
standards, specifications, approvals
UL/ETL listing / 300 V Rating No
UL/ETL style / 600 V Rating No
certificate of suitability
● EAC approval Yes
● UL approval Yes
standard for structured cabling Cat5
Marine classification association
● American Bureau of Shipping Europe Ltd. (ABS) No
● French marine classification society (BV) No
● Det Norske Veritas (DNV) No
● Germanische Lloyd (GL) No
● Lloyds Register of Shipping (LRS) No
● Nippon Kaiji Kyokai (NK) No
● Polski Rejestr Statkow (PRS) No
reference code
● according to IEC 81346-2 WG
● according to IEC 81346-2:2019 WGB
further information / internet links
internet link
● to website: Selection guide for cables and connectors https://support.industry.siemens.com/cs/ww/en/view/109766358
● to web page: selection aid TIA Selection Tool https://www.siemens.com/tstcloud
● to website: Industrial communication https://www.siemens.com/simatic-net
● to web page: SiePortal https://sieportal.siemens.com/
● to website: Image database https://www.automation.siemens.com/bilddb
● to website: CAx-Download-Manager https://www.siemens.com/cax
● to website: Industry Online Support https://support.industry.siemens.com
security information
security information Siemens provides products and solutions with industrial cybersecurity functions
that support the secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber
threats, it is necessary to implement – and continuously maintain – a holistic,
state-of-the-art industrial cybersecurity concept. Siemens’ products and
solutions constitute one element of such a concept. Customers are responsible
for preventing unauthorized access to their plants, systems, machines and
networks. Such systems, machines and components should only be connected
to an enterprise network or the internet if and to the extent such a connection is
necessary and only when appropriate security measures (e.g. firewalls and/or
network segmentation) are in place. For additional information on industrial
cybersecurity measures that may be implemented, please visit
www.siemens.com/cybersecurity-industry. Siemens’ products and solutions
undergo continuous development to make them more secure. Siemens strongly
recommends that product updates are applied as soon as they are available
and that the latest product versions are used. Use of product versions that are
no longer supported, and failure to apply the latest updates may increase
customer’s exposure to cyber threats. To stay informed about product updates,

6XV18502GH20 Subject to change without notice


11/11/2024
Page 2/3 © Copyright Siemens
subscribe to the Siemens Industrial Cybersecurity RSS Feed under
https://www.siemens.com/cert. (V4.7)
Approvals / Certificates
General Product Approval

Manufacturer Declara- Declaration of Con-


tion formity

For use in hazardous locations Test Certificates Environment Industrial Communication

Special Test Certific- Confirmation PROFINET


ate

last modified: 8/8/2024

6XV18502GH20 Subject to change without notice


11/11/2024
Page 3/3 © Copyright Siemens

You might also like