AXIAL VIBRATION LIMITS FOR SAFE ENGINE OPERATION
Axial Vibration Monitor AVM-KM30-13 User's Manual
SYSTEM DESCRIPTIONS
The AVM-KM30-13 (Axial Vibration Monitor The "Power Fail Output", an on/off signal
with 30mm diameter probe) is a control and with a potential-free contact(NO) or normal
monitoring system capable of measuring axial -close contact(NC), is set if the power
crankshaft vibrations on diesel engines. The source is lower than 18V or higher than
system is designed to be mounted directly 29V. In an occasion, "99.11" is displayed on
onto the main engine. The system consists an internal four-digit display. When the
of a control unit based on analog and digital power is normal "99.11" will automatically
technology and an inductive analog proximity reset and activated contact will release.
sensor(probe). The "Vibration High Alarm Output", an on/off
The AVM-KM30-13 is capable of measuring signal with a potential-free contact(NO) or
0.00~13.00 mm peak-to-peak displacement. normal-close contact(NC), is activate if the
The probe supplied by KOMECO delivers a peak-to-peak signal exceeds a setpoint of
current signal directly proportional to the the high vibration for mare than the "Slow
between the probe and the crankshaft to the Down Delay Time". The reset of the "VIB.
control unit. HIGH" output occurs as soon as the
peak-to-peak signal has dropped below the
setpoint. The setpoint for "Vibration High
Alarm Output" is shown on the display by
FUNCTIONAL DESCRIPTIONS pressing the "HIGH VIB. VIEW" button.
Setting of the setpoint for "High Vibration
The control unit converts the current signal Output" is done by pressing the "HIGH VIB.
from the probe to a value of 1 volt per mm VIEW" and adjusting the "VIB. HIGH"
displacement of the crankshaft. This signal is potentiometer.
sent to the "Crankshaft Position Output" The "Slow Down Output", an on/off signal
primary used for test. with a potential-free contact(NO) or normal-
The sampling time is 500㎲. So, this close contact(NC), is set if the peak-to-peak
converted signal is real value to raw signal. signal exceeds a setpoint for more than the
The peak-to-peak value of the displacement "Slow Down Delay Time". The setpoint and
is displayed on an internal four-digit display the "Slow Down Delay Time" are internal
with a resolution of 0.01mm and sent
adjustable. The reset of the "Slow Down
through a voltage-to-current converter, to
Output" and the "Slow Down Delay Time"
the "Alarm/ Monitoring Current Output", as a
occurs as soon as the peak-to-peak signal
4~20mA current signal. If a vibration is over
has dropped below the setpoint.
than 10.00mm then a output current is 4mA.
The setpoint for "Slow Down Output" is
However, a indication is enable to display
over 0 ~ 13.00 mm. shown on the display by pressing the "SLOW
When the peak-to-peak displacement signal DOWN VIEW" button. Setting of the setpoint
from the probe decreases, the value of the for "Slow Down Output" is done by pressing
display and the "Alarm/Monitoring Current the "SLOW DOWN VIEW" button and
Output" will not follow immediately, but fall adjusting the "SLOW DOWN" potentiometer.
slowly to the actual peak-to-peak displace- Setting of the slow down delay time is done
ment. The converted signal is processed in a by setting the "SLOW DOWN TIME
analytical method. This output signal is not SETTING" switch to one of the following
real value to raw signal, because it is not positions.
processed on real time base.
1
Axial Vibration Monitor AVM-KM30-13 User's Manual
0 = 0 sec. 6 = 120 sec. C = 240 sec. 2.00 : Scanning the set value of vibration
1 = 20 sec. 7 = 140 sec. D = 260 sec. high alarm
2 = 40 sec. 8 = 160 sec. E = 280 sec.
3.00 : Scanning the set value of user range
3 = 60 sec. 9 = 180 sec. F = 300 sec.
4 = 80 sec. A = 200 sec. low
5 = 100 sec. B = 220 sec. 4.00 : Scanning the set value of user range
Recommended initial setting : 100 sec. high
5.00 : Scanning the set value of slow down
User range setting provide advantage that time
end users can easily mount a probe(sensor) Check the voltage on K21(+), K23(-).
onto engine without a special mount jig. If For the AVM-KM30-13 the Vp readout
an end user mounts a probe (sensor) closer should be 14.5~15.5 V.
from the crankshaft than low set value, If not, the circuit board may be defective
"99.33" is displayed on an internal four-digit and should be replaced.
display. And if an end user mounts a
probe(sensor) far away from crankshaft than
high set value, "99.44" is displayed on an
internal four-digit display. User range low or
high setting can only done by KOMECO.
The short-circuit/disruption of the probe
cable will be indicated on the display by
"99.22". The "99.33" and "99.44" error
messages can be recovered by pressuring
two view buttons simultaneously.
TROUBLE SHOOTING
I. Standard procedures
In case of suspected malfunction, a structur-
ed system test should be carried out. By
following the below steps, a complete
system test is carried out, and an
identification of the problem should be
possible.
2
Axial Vibration Monitor AVM-KM30-13 User's Manual
3
Axial Vibration Monitor AVM-KM30-13 User's Manual
III. Check of the electronic cabinet After the scanning is terminated the display
during power on will return to normal condition and indicate
Connect resistor Res1 to K21 and K22(Res1 0.00~0.05mm.
= 2k2 = 2.2㏀, not part of KOMECO A/S If not, the circuit board may be defective
scope of supply) and should be replaced.
When the power is turned on the display will
indicate 88.88. After one second the control
will scan the value user's of setting.
4
Axial Vibration Monitor AVM-KM30-13 User's Manual
5
Axial Vibration Monitor AVM-KM30-13 User's Manual
6
Axial Vibration Monitor AVM-KM30-13 User's Manual
VI. Check of the electronic cabinet for Adjust the "SLOW DOWN" to approximately
Slow Down Output 2.0mm.
Connect an ohm-meter to K42 and K43 for By continuously disconnecting and connecting
Normal-Open(NO), to K41 and K42 for Res2 the display will change indication.
Normal-Close(NC). By permanently disconnecting or connecting
Adjust the "SLOW DOWN TIME SETTING" to Res2 the display will return slowly to an
position "0". indication of 0.00-0.05mm.
Connect the power source to K11(+) and
K13(-).
7
Axial Vibration Monitor AVM-KM30-13 User's Manual
At display indications higher than the adjusted VII. Check of the electronic cabinet
SLOW DOWN the Slow Down Output relay will for Vibration High Alarm Output
be activated: Rsd = 0Ω Connect an ohm-meter to K52 and K53 for
for Normal-Open(NO), Normal-Open(NO), to K51 and K52 for
Rsd = ∞Ω Normal-Close(NC).
for Normal-Close(NC). Connect the power source to K11(+) and
At display indications lower than the adjusted K13(-).
SLOW DOWN the Slow Down Output relay will Adjust the HIGH VIB. to approximately 2.00
be deactivated : Rsd = ∞Ω mm.
for Normal-Open(NO), By continuously disconnecting and connecting
Rsd = 0Ω Res2 the display will change indication.
for Normal-Close(NC). By permanently disconnecting or connecting
If not, the circuit board may be defective Res2 the display will return slowly to an
and should be replaced. indication of 0.00-0.05mm.
At display indications higher than the
adjusted HIGH VIB. the Vibration High Alarm
Output relay will be activated:
Rsd = 0Ω for Normal-Open(NO),
Rsd = ∞Ω for Normal-Close(NC).
At display indications lower than the
adjusted HIGH VIB. the Vibration High Alarm
Output relay will be deactivated :
Rsd = ∞Ω for Normal-Open(NO),
Rsd = 0Ω for Normal-Close(NC).
If not, the circuit board may be defective
and should be replaced.
8
Axial Vibration Monitor AVM-KM30-13 User's Manual
VIII. Check of the electronic cabinet Rsd = 0Ω for Normal-Open(NO), Rsd = ∞Ω for
for Power Fail Output Normal-Close(NC).
Connect an ohm-meter to K62 and K63 for By setting the power source between 18V
Normal-Open(NO), to K61 and K62 for and 29V the display will return to an
Normal-Close(NC). indication of 0.00~0.05mm and the Power
Connect the power source to K11(+) and Failure Alarm Output relay will be
K13(-). deactivated : Rsd = ∞Ω for Normal-Open
By falling the power source down below 18V (NO), Rsd = 0Ω for Normal-Close(NC).
or raising it up above 29V the readout will If not, the circuit board may be defective
be "99.11" and the Power Failure Alarm and should be replaced.
Output relay will activated:
9
Axial Vibration Monitor AVM-KM30-13 User's Manual
IX. Check of the Probe If Ip varies, check Ip vs. the distance to the
Connect the power supply and an amp-meter metal. If measurements(mA vs. mm) differ
to the probe. significantly from the calibration data found
First, check the connection by moving a on the probes calibration sheet, the probe
piece of metal back and forth in front of the should be replaced.
probe. If no variation in Ip is found, the
probe or the probe cable may be defective.
10
Axial Vibration Monitor AVM-KM30-13 User's Manual
X. Check of the electronic cabinet for The measurement range is from 0.00 to
Voltage Output 13.00 V and the value is linear on the range
Connect the probe cable to K21,22,23. from 3.50 to 13.0V. If Vp is not significantly
Connect an voltmeter to the BNC. proportional to the distance the circuit board
By connecting Res1 the voltage output will may defective and should be replaced.
be 7.40V. By connecting Res1 and Res2 the
voltage output will be 10.60V.
By continuously connecting and disconnecting
Res2 the voltage output will change from 7.4
to 10.6V.
11
Axial Vibration Monitor AVM-KM30-13 User's Manual
SYSTEM SET-UP
After mounting the probe and connecting the
circuit board, the Axial Vibration Monitor is
ready for set-up.
12
Axial Vibration Monitor AVM-KM30-13 User's Manual
13
Axial Vibration Monitor AVM-KM30-13 User's Manual
SPECIFICATIONS
OPERATING
TEMPERATURE RANGE : -10℃ to 60℃
PROTECTION : IP67
WEIGHT : 3.3kg
Note
1) : The user can install a probe at wanted mounting distance only if a distance between the crankshaft and the probe
is not absolutely over the normal range. For example, it is 8.50 mm for an Man B&W diesel engine and is 6.50
mm for a sulzer type diesel engine. It is at user's option to select a cable length of the probe.
14