Performance Test On Reciprocating Pump
Performance Test On Reciprocating Pump
APPARATUS REQUIRED:
Reciprocating pump
Stopwatch
Pressure gauge
Vacuum gauge
CALCULATION:
1. Discharge:
Area of Tank =0.4×0.4m2 = 0.16m2
Rise of level (h) =10 cm = 0.1m
Volume of collected = A×h m3 =0.016m3
Time taken for 10 cm rise of water = t secs
Discharge Q = Volume / Time= 0.016 / t m3/s
2. Head
Total head H = 10(P+V/760) m of water
3. Output of pump
Pump output =(9.81×Q×H) kW
4. Input of pump
Energy meter constant, K =1200 revs per kW
Time taken for 10 pulses of Energy meter = T secs
Input to motor =(3600×10)(K×T) kW
Efficiency of motor = 80% assumed
= [3600×10×0.8 /1200×T] kW
= (24 / T) kW
Pump input =Motor output
= (24 / T) kW
5. Pump Efficiency
Pump efficiency = Pump Output/ Pump Input
TABULATION:
Result :
The characteristic test was conducted on the reciprocating pump and the following graphs were drawn:
i) H vs Qact
ii) H vs ηpump
iii) H vs Po &
2. Head
Total head H = 10(P+V/760) m of water
3. Output of pump
Pump output =(9.81×Q×H) kW
4. Input of pump
Energy meter constant, K =1600 revs per kW
Time for 10 pulses of Energy meter = T secs
Input to motor = (3600×10)(K×T) kW
Efficiency of motor = 80% assumed
Motor output = [3600×10×0.8/1600×T] kW
= 18/T
Pump input = Motor output
= 18/T
5. Pump efficiency
Pump efficiency = Pump Output/ Pump Input
TABULATION
1
2
3
4
5
Result:
The characteristic test was conducted on the centrifugal pump and the following graphs were drawn:
i) H Vs Qact
ii) H Vs η pump &
iii) H Vs Po