PRWPP Draft Wind Turbine Specifications Report
PRWPP Draft Wind Turbine Specifications Report
PRWPP Draft Wind Turbine Specifications Report
Prepared for:
Boralex Inc.
772 Sherbrooke St. West
Suite 200
Montreal QC H3A 1G1
In Association with:
Prepared by:
Record of Revisions
Revision Date Description
0 November 2012 Submission to Municipalities and Aboriginal
Communities
1 December 2012 Submission to Public
PORT RYERSE WIND POWER PROJECT
WIND TURBINE SPECIFICATIONS REPORT
Table of Contents
List of Tables
Table 1.1: Wind Turbine Specifications Report Requirements: O. Reg. 359/09 ....................... 1.2
Table 2.1: Siemens SWT-3.0-113 - Wind Turbine Specifications ............................................. 2.1
List of Appendices
i
PORT RYERSE WIND POWER PROJECT
WIND TURBINE SPECIFICATIONS REPORT
1.0 Introduction
Boralex Inc. (Boralex), in association with UDI Renewables Corporation (UDI), is proposing to
develop the Port Ryerse Wind Power Project (the Project) east of the hamlet of Port Ryerse in
Norfolk County , Ontario, in response to the Government of Ontario’s initiative to promote the
development of renewable electricity in the province. The Project was awarded a Feed-In-Tariff
(FIT) contract with the Ontario Power Authority (OPA) on February 25, 2011. Further
information on the Project can be found on the Project-specific website at http://www.udi-
canada.com. Boralex Inc. is a power producer whose core business is dedicated to the
development and operation of renewable energy facilities. Further information on Boralex can
be found at http://www.Boralex.com/en/.
The Renewable Energy Approval (REA) process for the Port Ryerse Project was originally
initiated by UDI, with the assistance of M.K. Ince and Associates Ltd. Boralex is considering
acquisition of the Project from UDI and retained Stantec Consulting Ltd. (Stantec) to complete
the REA Application, as required under Ontario Regulation 359/09 - Renewable Energy
Approvals under Part V.0.1 of the Act of the Environmental Protection Act (O. Reg. 359/09).
According to subsection 6(3) of O. Reg. 359/09, the Project is classified as a Class 4 Wind
Facility and will follow the requirements identified in O. Reg. 359/09 for such a facility.
The Project Study Area is generally bounded by i) Woolley and Gilbert Roads to the north; ii)
Port Ryerse Road to the west; iii) Hay Creek to the east and iv) Avalon Lane to the south. The
proposed Project Location includes all parts of the land in, on, or over which the Project is
proposed. The Project Location, including all Project infrastructure, is sited on privately-owned
lands, where landowners have entered into a lease agreement with Boralex/UDI. Permissions to
access these properties have been obtained through verbal discussions with landowners, as a
requirement of their signed agreements with Boralex /UDI.
Three wind turbine models were initially assessed as part of the REA process, the Siemens
SWT 3.0 113, ENERCON E-92 2.35 MW and ENERCON E-82 E2 2.3MW; however one turbine
model has been selected as the preferred alternative; the Siemens SWT 3.0 113.
The Project will include four Siemens SWT 3.0 113 wind turbine generators. The 3.0 MW
turbines will be customized to a nameplate capacity of 2.897 MW for this Project. The total
maximum installed nameplate capacity of all four turbines will not exceed 10 MW. Other basic
components include step-up transformers located adjacent to the base of each turbine (step up
voltage from approximately 0.69 kV to 27.6 kV), a 27.6 kV underground collector system, fibre
optic data lines, a distribution substation, a permanent parking lot (if required), a meteorological
tower and turbine access roads.
Temporary components during construction include laydown areas at the turbine locations and
crane pads. No operations and maintenance building or transmission line is anticipated to be
required for the Project. No Project components are located within municipal road Rights of
Way (ROWs).
1.1
PORT RYERSE WIND POWER PROJECT
WIND TURBINE SPECIFICATIONS REPORT
Introduction
December 2012
The 27.6 kV underground collector lines will transport the electricity generated from each turbine
to the distribution substation located on private property east of Port Ryerse Road. Directional
bore techniques will be used where the underground collector lines cross valleylands and
watercourses. At the substation, a dip-pole connection will be made directly into the local
distribution system.
This Wind Turbine Specifications Report is one component of the REA Application for the
Project, and has been prepared in accordance with Item 13, Table 1 of O. Reg. 359/09 which
sets out specific content requirements as provided in the Table 1.1.
1.2
PORT RYERSE WIND POWER PROJECT
WIND TURBINE SPECIFICATIONS REPORT
The Project will consist of four Siemens SWT-3.0-113 wind turbine generators. The 3.0 MW
turbines will be customized to a nameplate capacity of 2.897 MW for this Project. The total
maximum installed nameplate capacity of all four turbines will not exceed 10 MW. The
following table (Table 2.1) provides a description of the Siemens SWT-3.0-113 wind turbine
which will be used for the Project. Additional turbine specifications are provided in Appendix A.
Please refer to Appendix A Turbine Specifications from the Manufacturer for additional acoustic
emissions data, in accordance with the International Electrotechnical Commission (IEC)
Standard 61400-11:2002 (equivalent to the CAN/CSA-C61400-11-07, “Wind Turbine Generator
Systems-Part II: Acoustic Noise Measurements Techniques” (October 2007), for the Siemens
SWT 3.0-113 turbine with a maximum power rating of 2.897 MW.
2.1
PORT RYERSE WIND POWER PROJECT
WIND TURBINE SPECIFICATIONS REPORT
Wind Turbines
December 2012
The tower supports the nacelle which houses the main components of the wind turbine
(comprised of electrical generator and housing). The nacelle cover is made of glass-fibre
reinforced plastic and is accessible from the tower via a hatch in the base frame. A step-up
transformer, located adjacent to the base of each wind turbine, is required to transform the
electricity created in the nacelle to a standard operating power line voltage (27.6 kV). The
converter is located within the nacelle and controls the energy conversion in the generator by
feeding power to and from the grid.
The 113 m rotor supports three blades, equipped with lightening protection, and a hub. The
blade design comprises a strong structure to face high wind loads but also lightweight
construction to minimize the load transmission of the nacelle. This is achieved by the use of
glass-fibre reinforced plastic sandwich construction. The blades are 55 m in length. The pitch
of the blades is adjustable, allowing maximum energy input from the wind and also acting as a
braking system. They are designed to cut-out when wind speeds exceed 25 m/s (90 km/h).
2.2
PORT RYERSE WIND POWER PROJECT
WIND TURBINE SPECIFICATIONS REPORT
3.0 Closure
The Port Ryerse Wind Power Project Wind Turbines Specifications Report has been prepared
by Stantec Consulting Ltd. for Boralex/UDI in accordance with Item 13, Table 1 of O. Reg
359/09.
This report has been prepared by Stantec for the sole benefit of Boralex/UDI, and may not be
used by any third party without the express written consent of Boralex/UDI. The data presented
in this report are in accordance with Stantec’s understanding of the Project as it was presented
at the time of reporting.
Respectfully submitted,
STANTEC CONSULTING LTD.
rpt_60773_wtsr_201212_dft_fnl.docx
3.1
PORT RYERSE WIND POWER PROJECT
WIND TURBINE SPECIFICATIONS REPORT
4.0 References
O. Reg. 359/09. 2009. Ontario Regulation 359/09 made under the Environmental Protection Act
Renewable Energy Approvals Under Part V.0.1 of the Act, as amended by O. Reg.
333/12 on November 2, 2012.
4.1
PORT RYERSE WIND POWER PROJECT
WIND TURBINE SPECIFICATIONS REPORT
Appendix A
SWT-3.0-113
Technical Specifications
Rotor Generator
Type ................................... 3-bladed, horizontal axis Type ................................... Synchronous, PMG
Position .............................. Upwind Nominal power .................... 3000 kW
Diameter ............................ 113 m
Swept area ......................... 10.000 m² Grid Terminals (LV)
Speed range ....................... 6-15.5 rpm Nominal power .................... 3000 kW
Power regulation ................. Pitch regulation with variable Voltage ............................... 690 V
speed Frequency .......................... 50 Hz or 60 Hz
Rotor tilt ............................. 6 degrees
Yaw System
Blade Type ................................... Active
Type ................................... Self-supporting Yaw bearing ....................... Externally geared
Blade length ....................... 55 m Yaw drive ........................... 8 (optional 10) electric gear
Tip chord ............................ 0.63 m motors
Root chord ......................... 4.2 m Yaw brake .......................... Passive friction brake
Aerodynamic profile ............ NB1-7, SWPNA1_XX12,
FFAxxx Controller
Material .............................. GRE Type ................................... Microprocessor
Surface gloss ..................... Semi-gloss, < 30 / ISO2813 SCADA system ................... WPS
Surface colour .................... Light grey, RAL 7035 Controller designation ......... SWTC, STC-1, SCS-1
Siemens Wind Power A/S reserves the right to change the above specifications without previous notice.
Up to
Wind speed [m/s] 4 5 6 7 8 9 10 11 12 cut-
out
Sound power level 96.5 102.3 103.6 104.0 104.0 104.0 104.0 104.0 104.0 104.0
Table 1: Noise emission, L WA [dB(A) re 1 pW]
O t
Octave b d centre
band, t ffrequency [H[Hz]] 63 125 250 500 1000 2000 4000 8000
Sound power level 84.7 90.7 97.6 97.3 98.0 95.6 84.6 66.9
Table 2: Typical octave band for 6 m/s, L WA [dB(A) re 1 pW]
Octave band, centre frequency [Hz] 63 125 250 500 1000 2000 4000 8000
Sound power level 86.5 94.1 96.9 97.6 97.6 96.6 89.9 73.6
Table 3: Typical octave band for 8 m/s, L WA [dB(A) re 1 pW]
Measurement Uncertainty
A margin corresponding to -1.5dB(A) and +1.5dB(A) is applicable.
Tonal Audibility
As measured in accordance with IEC 61400-11, tonal audibility produced by the SWT-3.0-113 at 99.5m Hub
height will not be more than 2dB.
p 1/1
Siemens Wind Power A/S SWT-3.0-113 99.5 m Acoustic Emission extended CAN ver
© All Rights Reserved 2012 T20110701