Circuit breaker size S3 for starter combination Rated current 50 A N-release 650 A
screw terminal Standard switching capacity

product brand name SIRIUS


product designation Circuit breaker
design of the product For starter combinations
product type designation 3RV2
General technical data
size of the circuit-breaker S3
size of contactor can be combined company-specific S3
product extension auxiliary switch Yes
power loss [W] for rated value of the current
● at AC in hot operating state 27 W
● at AC in hot operating state per pole 9W
insulation voltage with degree of pollution 3 at AC rated value 1 000 V
surge voltage resistance rated value 8 kV
shock resistance according to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (operating cycles)
● of the main contacts typical 25 000
● of auxiliary contacts typical 25 000
electrical endurance (operating cycles) typical 25 000
reference code according to IEC 81346-2 Q
Substance Prohibitance (Date) 03/01/2017
SVHC substance name Lead - 7439-92-1
Weight 2.214 kg
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
● during operation -20 ... +60 °C
● during storage -50 ... +80 °C
● during transport -50 ... +80 °C
relative humidity during operation 10 ... 95 %
Environmental footprint
Global Warming Potential [CO2 eq] total 283.24 kg
Global Warming Potential [CO2 eq] during manufacturing 18.5 kg
global warming potential [CO2 eq] during sales 1.24 kg
Global Warming Potential [CO2 eq] during operation 265 kg
Global Warming Potential [CO2 eq] after end of life -1.5 kg
Siemens Eco Profile (SEP) Siemens EcoTech
Main circuit

3RV23414HC10 Subject to change without notice


11/6/2024
Page 1/6 © Copyright Siemens
number of poles for main current circuit 3
operating voltage
● rated value 20 ... 690 V
● at AC-3 rated value maximum 690 V
● at AC-3e rated value maximum 690 V
operating frequency rated value 50 ... 60 Hz
operational current rated value 50 A
operational current
● at AC-3 at 400 V rated value 50 A
● at AC-3e at 400 V rated value 50 A
operating power
● at AC-3
— at 230 V rated value 11 kW
— at 400 V rated value 22 kW
— at 500 V rated value 30 kW
— at 690 V rated value 45 kW
● at AC-3e
— at 230 V rated value 11 kW
— at 400 V rated value 22 kW
— at 500 V rated value 30 kW
— at 690 V rated value 45 kW
operating frequency
● at AC-3 maximum 15 1/h
● at AC-3e maximum 15 1/h
Protective and monitoring functions
product function
● ground fault detection No
● phase failure detection No
maximum short-circuit current breaking capacity (Icu)
● at AC at 240 V rated value 100 kA
● at AC at 400 V rated value 65 kA
● at AC at 500 V rated value 12 kA
● at AC at 690 V rated value 6 kA
operating short-circuit current breaking capacity (Ics) at AC
● at 240 V rated value 100 kA
● at 400 V rated value 30 kA
● at 500 V rated value 6 kA
● at 690 V rated value 3 kA
response value current of instantaneous short-circuit trip unit 650 A
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor
● at 480 V rated value 50 A
● at 600 V rated value 50 A
yielded mechanical performance [hp]
● for single-phase AC motor
— at 110/120 V rated value 5 hp
— at 230 V rated value 10 hp
● for 3-phase AC motor
— at 200/208 V rated value 15 hp
— at 220/230 V rated value 20 hp
— at 460/480 V rated value 40 hp
— at 575/600 V rated value 50 hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
fastening method screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
height 165 mm
width 70 mm

3RV23414HC10 Subject to change without notice


11/6/2024
Page 2/6 © Copyright Siemens
depth 176 mm
required spacing
● with side-by-side mounting at the side 0 mm
● for grounded parts at 400 V
— downwards 70 mm
— upwards 70 mm
— at the side 10 mm
● for live parts at 400 V
— downwards 70 mm
— upwards 70 mm
— at the side 10 mm
● for grounded parts at 500 V
— downwards 110 mm
— upwards 110 mm
— at the side 10 mm
● for live parts at 500 V
— downwards 110 mm
— upwards 110 mm
— at the side 10 mm
● for grounded parts at 690 V
— downwards 150 mm
— upwards 150 mm
— backwards 0 mm
— at the side 30 mm
— forwards 0 mm
● for live parts at 690 V
— downwards 150 mm
— upwards 150 mm
— backwards 0 mm
— at the side 30 mm
— forwards 0 mm
Connections/ Terminals
type of electrical connection
● for main current circuit screw-type terminals
arrangement of electrical connectors for main current Top and bottom
circuit
type of connectable conductor cross-sections
● for main contacts
— solid 2x (2.5 ... 16 mm²)
— solid or stranded 2x (2,5 ... 50 mm²), 1x (10 ... 70 mm²)
— finely stranded with core end processing 2x (2.5 ... 35 mm²), 1x (2.5 ... 50 mm²)
— finely stranded without core end processing 2x (10 ... 35 mm²), 1x (10 ... 50 mm²)
tightening torque
● for main contacts for ring cable lug 4.5 ... 6 N·m
outer diameter of the usable ring cable lug maximum 19 mm
tightening torque
● for main contacts with screw-type terminals 4.5 ... 6 N·m
Safety related data
product function suitable for safety function Yes
suitability for use
● safety-related switching on No
● safety-related switching OFF Yes
service life maximum 10 a
test wear-related service life necessary Yes
proportion of dangerous failures
● with low demand rate according to SN 31920 40 %
● with high demand rate according to SN 31920 50 %
B10 value with high demand rate according to SN 31920 5 000
failure rate [FIT] with low demand rate according to SN 50 FIT
31920
ISO 13849

3RV23414HC10 Subject to change without notice


11/6/2024
Page 3/6 © Copyright Siemens
device type according to ISO 13849-1 3
overdimensioning according to ISO 13849-2 necessary Yes
IEC 61508
safety device type according to IEC 61508-2 Type A
T1 value
● for proof test interval or service life according to IEC 10 a
61508
Electrical Safety
protection class IP on the front according to IEC 60529 IP20
touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front
Display
display version for switching status Handle
Approvals Certificates
General Product Approval

Confirmation KC

General Product Ap-


Test Certificates Marine / Shipping
proval

Type Test Certific- Special Test Certific-


ates/Test Report ate

Marine / Shipping other

Miscellaneous Confirmation

Railway Environment

Special Test Certific- Environmental Con-


ate firmations

Further information
Information on the packaging
https://support.industry.siemens.com/cs/ww/en/view/109813875
Information- and Downloadcenter (Catalogs, Brochures,…)
https://www.siemens.com/ic10
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2341-4HC10
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2341-4HC10
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RV2341-4HC10
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2341-4HC10&lang=en
Characteristic: Tripping characteristics, I²t, Let-through current
https://support.industry.siemens.com/cs/ww/en/ps/3RV2341-4HC10/char
Further characteristics (e.g. electrical endurance, switching frequency)
http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RV2341-4HC10&objecttype=14&gridview=view1

3RV23414HC10 Subject to change without notice


11/6/2024
Page 4/6 © Copyright Siemens
1/L1

3/L2

5/L3

-F

I> I> I>


2/T1

4/T2

6/T3

last modified: 11/6/2024

3RV23414HC10 Subject to change without notice


11/6/2024
Page 5/6 © Copyright Siemens
3RV23414HC10 Subject to change without notice
11/6/2024
Page 6/6 © Copyright Siemens

You might also like