You are on page 1/ 8

Selection manual of RNC

industrial control relay Interface Relay Module

Ultra-slim, high sensitivity and low consumption, the maximum load power 6A.
Reasonable structure, meets environmental protection requirements, the control voltage range
can be extended with matching sockets.
Shenler industrial relays are widely used in the output signal and safety drive of PLC, CNC system,
robot, intelligent manufacturing and other control systems. It is the best choice to realize remote
control, production and processing, packaging, transportation, testing, storage and other
equipment and automatic assembly lines.

6.3mm wide
Save space.

Push handle
Convenient to replace and install. Bus jumper
To extend the circuit.

Recognizable LED
Easy to identify

Circuit protection design


Bridge rectifier circuit, built-in
surge absorber for AC and DC,
in avoid of overvoltage.

RoHS

03 / SHENLE CORPORATION LTD.


Selection manual of RNC
industrial control relay Interface Relay Module RoHS

RNC

Other options
Blank: Conventional
A: Gold plated contact

Coil voltage code

Terminal arrangement
O: Vertical pin
Relay
P: Horizontal pin

Contact form
+ 1A: (NO)
1C: (CO)

Series

Characteristics
Configuration 1A,1C
Load Resistance 6A/250VAC 30VDC
Max. switching capacity (resistive) 1500VA,180W
Min. switching capacity 170mW(17V/10mA)
Contact
Initial contact resistance ≤100mΩ (gold plated contact ≤ 30mΩ)
Material Ag alloy
4
Socket Electrical durability (normal tempe- NO: 6x10 Cycles (600 Ops/h);
4
rature)(frequency 1s on, 5s off) NC: 3x10 Cycles (600 Ops/h)
7
Mechanical durability ≥2 x 10 Cycles (18000 Ops/h)
Pick-up voltage (23℃) (Rated voltage) DC:≤75%
=
Drop-out voltage (23℃) (Rated voltage) DC:≥5%
Maximum voltage (23℃) (Rated voltage) 110%
Insulation resistance ≥1000MΩ (500VDC)
3~24 VDC approx. 0.175W
Coil operating power
48~60 VDC approx. 0.21W
Operate time (at nominal voltage) ≤8ms
Release time (at nominal voltage) ≤4ms
Initial breakdown Between open contacts 1000VAC/1min (leakage current 1mA)
voltage Between contacts and coil 4000VAC/1min (leakage current 1mA)
Insulation Rated voltage 250VAC
characteristics Pollution level 3
IEC 60664 UL840 Overvoltage level III
Impulse withstand voltage (waveform: 1.2/50μs ) 4000V
Relay module Protection level IP20
Storage temperature/ humidity -55~+85℃/ ≤85%RH (18 months)
Working temperature/ humidity -40~+85℃/ 5%~85%RH (No condensation)
Air pressure 86~106KPa
Shock resistance 10G (half-sine shock pulse: 11ms)
Vibration resistance 10~55Hz double-amplitude:1.0mm
Mounting PCB
Unit weight approx. 6g

/ 04
Selection manual of RNC
industrial control relay Interface Relay Module

Coil Specifications (23℃)


Nominal voltage V.DC (0.17W) 5 6 12 24
Coil resistance Ω 147 212 847 3250
Nominal voltage V.DC (0.21W) 48 60
Coil resistance Ω 10971 17143

Coil resistance: under coil voltage 110V are measured with tolerance of ±10%Ω.

Contact Specification
RNC1A, 1C
Electrical durability Maximum switching capacity

Contact current(A)
operating cycles)(x10 )

10
4
Durability(number of

AC resistive

DC resistive
1

0.5

0.1
1 5 10 50 100 200 300

current (A) Contact voltage(V)

Dimensions (mm)

Wiring Diagrams
1CO 1AO 1CP 1AP

Bottom view Bottom view

Side view Side view

05 / SHENLE CORPORATION LTD.


Selection manual of SNB05-E
industrial control relay RNC Socket

Characteristics
Model No. Input
SNB05-E-AR 6~24VDC 6~24VDC
SNB05-E-A 6~24V 6~24VDC
SNB05-E-B 48V
SNB05-E-C 110V
SNB05-E-D 48VDC
Characteristics
Current 8
Nominal load
Voltage
Dielectric Between coil and contact
strength Between contacts
Max. tightening torque
Wire size
Ambient temperature
Unit weight 19 5
Accessories
SNB05-E
Bus jumper Legend

Dimensions (mm)
6.3Max
72Max

35.5Max

76Max

Connection Diagrams

/ 06
Selection manual of SNB05-ST
industrial control relay RNC Socket

Characteristics
Model No. Input
SNB05-ST-AR 6~24VDC 6~24VDC
SNB05-ST-A 6~24V 6~24VDC
SNB05- ST-B 48V
SNB05-ST-C 110V
SNB05-ST-D 48VDC
Characteristics
Current 8
Nominal load
Voltage
Dielectric Between coil and contact
strength Between contacts
Wire size
Ambient temperature
Unit weight 19 5
press Accessories
Bus jumper Legend

SNB05-ST

Dimensions (mm)

6.3Max
72.5Max

35.5Max

88.5Max

Connection Diagrams

07 / SHENLE CORPORATION LTD.


Selection manual of SNC05-E
industrial control relay RNC Socket

Characteristics
Model No. Input
12~24V 12~24VDC
48~60V 48~60VDC

Characteristics
Current 8
Nominal load
Voltage
Dielectric Between coil and contact
strength Between contacts
Max. tightening torque
Wire size
Ambient temperature
Unit weight
Accessories
Bus jumper Legend Partition plate
SNC05-E

Dimensions (mm)

6.3Max
79.9Max

35.5Max

96.5Max

Connection Diagrams

/ 08
Selection manual of SNC05-S
industrial control relay RNC Socket

Characteristics
Model No. Input
12~24V 12~24VDC
48~60V 48~60VDC

Characteristics
Current 8
Nominal load
Voltage
Dielectric Between coil and contact
strength Between contacts
Wire size
Ambient temperature
Unit weight
Accessories
Bus jumper Legend Partition plate

SNC05-S

Dimensions (mm)

6.3Max
79.9Max

35.5Max

103.1Max

Connection Diagrams

09 / SHENLE CORPORATION LTD.


Selection manual of SNC05-P
industrial control relay RNC Socket RoHS

Characteristics
Current 8
Nominal load
Voltage

Dielectric Between coil and contact


strength Between contacts

Wire size
Ambient temperature
Unit weight 2.6

SNC05-P

Dimensions (mm)

33Max
33Max

6.2Max
4.2Max

1Max
0.5Max

Connection Diagrams

/ 10

You might also like