SIZING HORIZONTAL TWO PHASE SEPARATOR

1. Data
Gas flow rate MMSCFD 10
Gas specific gravity 0.6
Oil flow rate (Qgo) BPD 2000
Oil specific gravity API 40
Operating pressure psia 1000
Operating temperature F 60

2. Other Properties
Z factor 0.83 (From graph)
Gas viscosity (μg) cP 0.013 (From graph)

3. Calculate K (Constant that depends on the gas and liquid properties)


S.P/T 1.154
K berdasarkan grafik 0.28 (From graph)

4. Gas Capacity Constraint


d in 24.68

5. Liquid Capacity Constraint


Liquid capacity constraint for various retention time for liquid (t r)
tr (minute) d2h (in3)
1 16666.67
2 33333.33
3 50000.00

6,7,8. Seam-to-seam length for various retention time for liquid capacity constraints & slenderness ratio

tr (minute) Internal h (in) Effective Length, Leff (ft)


diameter, d
(in)

3 24 86.8 86.8
3 30 55.6 55.6
3 36 38.6 38.6
3 42 28.3 28.3
3 48 21.7 21.7
2 24 57.9 57.9
2 30 37.0 37.0
2 36 25.7 25.7
2 42 18.9 18.9
1 24 28.9 28.9
1 30 18.5 18.5
1 36 12.9 12.9

9. Graph

36

32
meter (in)

28
36

32

Vessel diameter (in)


28

24

20
5 6 7 8 9 10 11 12 13 14
Vessel length (ft)

tr = 3 min tr = 2 min tr = 1 min


Case:

& slenderness ratio

Seam-to-seam Slendernes
Length, Lss (ft) s ratio (12
Lss/d)

13.6 6.8
11.0 4.4
9.5 3.2
8.7 2.5
8.1 2.0
11.2 5.6
9.4 3.8
8.5 2.8
7.9 2.3
8.7 4.4
7.9 3.2
7.4 2.5
13 14
D 1250 49.2126
L 3750 147.6378