To configure your 590 DRV Digital DC Drive for the motor with the details you provided, follow

these
steps:

### Initial Setup


1. **Enter Configuration Mode**
- Press the "M" (Menu) button to access the main menu.
- Navigate to "CONFIGURE I/O" using the up (▲) or down (▼) buttons.
- Press "M" to enter the "CONFIGURE I/O" menu.
- Set "CONFIGURE ENABLE" to "ENABLE".

### Setting Motor Parameters


2. **Set Motor Voltage**
- Navigate to "Motor Parameters".
- Select "Motor Voltage" and set it to 440 V.
- Save the setting.

3. **Set Motor Current**


- Select "Motor Current" and set it to 397 A.
- Save the setting.

4. **Set Motor Power**


- Select "Motor Power" and set it to 160 kW (if applicable).
- Save the setting.

5. **Set Motor Speed**


- Select "Motor Speed" and set it to 1500 rpm.
- Save the setting.

### Setting Field (Excitation) Parameters


6. **Set Field Voltage**
- Navigate to "FIELD PARAMETERS".
- Select "FIELD VOLTAGE" and set it to 180 V.
- Save the setting.

7. **Set Field Current**


- If the motor documentation specifies the field current, enter that value in the "FIELD CURRENT"
setting.
- Save the setting.

8. **Set Field Control Mode**


- Navigate to "FIELD CONTROL MODE".
- Ensure it is set to "SEPARATELY EXCITED".
- Save the setting.

### Configuring Analog Input for Potentiometer


9. **Set Analog Input Destination Tag**
- Navigate to the input you want to configure (e.g., "ANIN 4" for the analog input connected to the
potentiometer).
- Select "DESTINATION TAG" and set it to control the speed setpoint (e.g., "0" for speed control).
- Save the setting.
10. **Calibrate Analog Input**
- Ensure the 0-10 V input from the potentiometer maps correctly to the speed range (0-1500 rpm).
- Adjust scaling as necessary.

### Setting Speed Parameters


11. **Set Max Speed**
- Navigate to "CONTROL PARAMETERS".
- Select "Max Speed" and set it to 1500 rpm.
- Save the setting.

12. **Set Min Speed**


- Select "Min Speed" and set it to 0 or the minimum operating speed required.
- Save the setting.

### Adjusting Deceleration Settings


13. **Increase Deceleration Time**
- Navigate to "CONTROL PARAMETERS".
- Select "DECELERATION TIME" and increase the value to allow for smoother deceleration.
- Save the setting.

### Final Steps

14. **Verify Settings**


- Double-check all the settings to ensure they are correct.

15. **Save and Exit**


- Save all the changes.
- Use the "E" (Escape) button to exit back to the main display.

16. **Test the Drive**


- Start the motor and gradually adjust the speed using the potentiometer.
- Monitor the drive and motor for any alarms or unusual behavior.

### Summary

1. Enter configuration mode.


2. Set motor voltage, current, power, and speed.
3. Configure field (excitation) parameters.
4. Set analog input destination tag for the potentiometer.
5. Calibrate analog input scaling.
6. Set speed parameters.
7. Adjust deceleration settings.
8. Verify and save all settings.
9. Test the drive.

By following these steps, you should be able to configure your 590 DRV Digital DC Drive to work with
your motor, ensuring that all necessary parameters are correctly set.