Bitzer
Bitzer
CONDENSING UNITS
THE RIGHT CHOICE FOR YOUR APPLICATION
KP-261-2 EN
CLOSER TO YOU.
BITZER WORLDWI DE.
PREMIUM RANGE
air-cooled
ADVANCED RANGE
air-cooled
STANDARD RANGE
air- and water-cooled
INNOVATION
AIR CONDITIONING
DRIVER SINCE
HEAT PUMPS
1934
EMPLOYEES
4000
REFRIGER ATION
PROCESS COOLING
SITES
TR ANSPORT 75
COUNTRIES
37
Learn more at bitzer.de.
2 // KP-261-2 EN KP-261-2 EN // 3
CONTENTS FOR EVERY CUSTOMER
FOR EVERY REQUIREMENT
ECOSTAR APPLI- CAPACIT Y REF.
Features and applications / product details / technical data HOUSING Q o R ANGE
CATIONS CONTROL CLASS
Page 06–19
ECOLITE
LT
Features and applications / product details / technical data PREMIUM VARISPEED
1.2 up to 9.3 kW
or
Page 20–33 A1
ECOSTAR VARIPACK
MT
(air-cooled)
2.6 up to 26 kW
FI
LHE 25–87 Hz
Features and applications / product details / technical data
Page 34–55
K-SERIES
LT
Features and applications / product details / technical data ADVANCED
A1 1.3 up to 6.0 kW
VARISTEP
Page 56–71 +
ECOLITE
A2L MT
(air-cooled) CRII
3.2 up to 24 kW
10%–100%
GREEN COMPETENCE
BITZER Digital Network / BITZER Services / BITZER Green Point / SCHAUFLER Academy
BITZER Selection Software / BEST Software / eParts / BITZER Apps
Page 72–75
optional LT
STANDARD
VARISTEP A1 0.4 up to 23 kW
optional +
LHE
CRII A2L MT
(air-cooled)
10%–100% 0.8 up to 60 kW
optional LT
STANDARD
VARISTEP A1 0.3 up to 28 kW
– +
K-SERIES
CRII A2L MT
(water-cooled)
10%–100% 0.8 up to 89 kW
4 // KP-261-2 EN KP-261-2 EN // 5
ECOSTAR RETAIL +
THE PREMIUM CHOICE CONVENIENCE PHARMA/
WHETHER SUPERMARKET OR PROCESS COOLING – THE ECOSTAR SERIES
STORES LABS
GUAR ANTEES THE HIGHEST EFFICIENCY WHILE ENSURING SAFE OPER ATION
AND CONTINUOUS ADAPTATION TO THE COOLING DEMAND
>>
functions.
// Highest fan efficiency due to EC fans
controlled by ECOSTAR controller
HOTEL/
PROCESS
THE PREMIUM SOLUTION BISTRO
COOLING +
FOR YOUR APPLICATION
The ECOSTAR air-cooled condensing unit offers COLD STORAGE
intelligent technology for efficient and safe
operation at any time. It is the ideal solution for
customers who are looking for a sustainable,
robust and easy plug-and-play concept made The ECOSTAR, an IQ pro-
of proven BITZER components. It is a perfect duct, combines the highest
match for commercial refrigeration with different efficiency for low operating
applications, such as cold storage, hotels and Process cooling and cold storage rooms costs with individual user
pharmaceutical processes. require different cooling capacities with a profiles – to provide guests
wide application range of the evaporating with a warm welcome.
temperature. The ECOLINE VARISPEED
compressor or ECOLINE with VARIPACK
enables low and medium temperatures
with a large frequency band (from 25 [30]
up to 87 Hz).
6 // KP-261-2 EN KP-261-2 EN // 7
THE INTELLIGENT
SOLUTION: ECOSTAR
– FOR COMMERCIAL
The premium choice for commercial refrigeration
– no matter if single or multi-evaporator instal-
lation. The BI T ZER ECOS TAR wit h fre quenc y
READY TO USE
PLUG-AND-PLAY CONCEP T >> The ECOSTAR combines the latest technologies,
such as highly efficient EC fans, comprehensive
controller functions and optimised mini-channel
condensers.
SUSTAINABLE
The ECOSTAR enables low refrigerant charges due to the optimised
FAST COMMISSIONING condenser and receiver design. It is also Ecodesign-compliant thanks
to its ECOLINE semi-hermetic compressor with frequency inverter
QUICK START-UP WITH
combined with EC fan(s).
FIVE PAR AME TERS ONLY
8 // KP-261-2 EN KP-261-2 EN // 9
ECOSTAR: THE PREMIUM
AIR-COOLED CONDENSING UNIT
The product picture shows an almost fully equipped ECOSTAR Unit with ECOLINE VARISPEED compressor. *Exception LHV7E/4NE-14.FY with adjustable high-pressure switch
For the standard extent of delivery and optionally available equipment, please see the following pages.
10 // KP-261-2 EN KP-261-2 EN // 11
BITZER CONTROLLER: FUNCTIONS E XTENT OF DELIVERY
OPER ATION MODES COMMUNIC ATION
ECOSTAR
// Suction pressure control // Bluetooth via BEST Software
AIR-COOLED CONDENSING UNITS WITH ECOLINE VARISPEED LHV5E/.. LHV7E/..
// Cold room temperature control (via laptop or BEST App)
COMPRESSORS OR ECOLINE WITH VARIPACK
// Mini USB via BEST Software/
PUMP DOWN/OUT MODE BEST App Semi-hermetic ECOLINE VARISPEED with integrated frequency inverter
S S
reciprocating compressor or ECOLINE with VARIPACK*
AND PI-CONTROL MODE // Modbus RTU (RS485)
Oil heater 200 .. 260 V, PTC S S
LIMITER CONTROL AND // On integrated display Connection for pressure relief valve at receiver / condenser S S
APPLIC ATION LIMITS PROTEC TION with alarm number,
Sight glass and filter drier in liquid line S S
failure code and short text
e.g. min. evaporating/
// Via BEST Software - cartridge pressure switch (not adjustable)
max. condensing temperature
- LHV7E/4NE-14.FY:
High and low pressure switch S S
// Via status lamps adjustable high
pressure switch
EMERGENCY MODE
// HP/LP or cold room sensor FUNC TIONS - for suction gas temperature
Temperature sensor - for discharge gas temperature S S
// Frequency inverter // Winter start
- for ambient temperature
// EC fan(s) control
Pressure transmitters for high and low pressure S S
// Oil return mode
- discharge line
// Wet operation detection
Complete piping - liquid line S S
// .. - suction line (insulated)
Oil charge BSE32 (ester oil) for HFC and HFC/HFO refrigerants tc < 70 °C S S
This provides you with important product and application-related information on all the BITZER products, including, S = extent of delivery
among others, data analyses and compressor operation reports. (Subject to change without notice)
- LHV7E/4DE-7.FY
- LHV7E/4CE-9.FY
GATEWAY WITH SECURE
- LHV7E/4VE-7.FY
GSM MODULE CONNECTION INTERNET CLOUD - LHV7E/4TE-9.FY
- LHV7E/4PE-12.FY
- LHV7E/4NE-14.FY
USER DEVICES
ON THE INTERNET
12 // KP-261-2 EN KP-261-2 EN // 13
E XTR AORDINARY OPTIONAL EQUIPMENT APPLICATION R ANGE
TO FULFILL YOUR DEMANDS
in liquid line
Check valve* ● ●
- mounted
APPLICATION LIMITS
t amb [°C]
Tentative data
to [°C]
to Evaporating temperature [°C]
LHV7E/4FE-5.F1Y 80Hz R448A/R449A toh=20 °C t amb Ambient temperature [°C]
LHV7E/4CE-9.FY 80 Hz R134a/R513A toh=20 °C toh Suction gas temperature [°C]
14 // KP-261-2 EN KP-261-2 EN // 15
ASERCOM CERTIFIED PERFORMANCE DATA BITZER CONDENSING UNITS
The Association of European Refrigeration Component These high efforts result in the fact that only a limited
COMPLYING WITH THE EU ECODESIGN
Manufacturers (ASERCOM) has implemented a procedure
of certifying condensing units performance data.
number of condensing units can be submitted. Due to
this not all BITZER products are certified yet.
REGULATION 2015/1095
Performance data of condensing units which meet the strict
The high standard of this certification is assured by requirements carry the label “ASERCOM certified performance”. Acoording to MEPS Tier-2, for more details
COP SEPR
// plausibility checks of the data performed by experts All certified condensing units and further information are listed please see BITZER brochure A-530-1
// regular random tests at independent institutes on ASERCOM web site (www.ASERCOM.org).
MT (to-10 °C) - refrigeration capacity 0,2...≤5 kW 5...50 kW
In the BITZER Software the
appropriate condensing units LT (to-35 °C)- refrigeration capacity 0,1...≤2 kW 2...20 kW
are marked with this label.
PERFORMANCE DATA
E XPLANATION OF T YPE DESIGNATION
REFRIGERATION CAPACITY Q o @ t amb 32 °C
R404A
R448A
MT, -10 °C, mid-point
R404A
R448A LHV7E / 4CE-9.F1 Y
R449A R449A condenser type compressor type
LH V5 E/2 DES-3 .F1 Y 11,74 10,77 7,81 6,44 7,38 3,76 2,96 5 = small housing
LH V5 E/4 FE-5 .F1 Y 14,89 14,14 9,81 8,13 9,28 5,27 4,17 7 = large housing
LH V5 E/4 EE-6 .F1 Y 17,34 16,65 12,42 10,5 11,89 6,34 5,09 frequency inverter size
LH V7 E/4 FE-5 .F1 Y 16,13 15,01 10,09 8,31 9,51 5,38 4,26 F = VARIPACK
F1 = VARISPEED
LH V7 E/4 EE-6 .F1 Y 19,13 18,01 13,03 10,84 12,38 6,51 5,23
LH V7 E/4 DE-5 .F1 Y 14,81 12,37 14,09 oil charge
LH V7 E/4 C E-6 .F1 Y 17,68 14,94 16,92 Y=ester oil
LH V7 E/4 DE-7.FY 21,5 19,92 14,81 12,36 14,08 7,71 5,85
LH V7 E/4 C E-9 .FY
LH V7 E/4 VE-7.FY
25 23,9 17,68
18,25
14,94
15,44
16,92
17,44
9,21 7,62
TECHNICAL DATA
LH V7 E/4 TE-9 .FY 21,2 18,12 20,4
LH V7 E/4 PE-1 2 .FY 23 19,75 22,1 weight in kg
max fan power max condenser receiver volume max. operating sound pressure
LH V7 E/4 NE-1 4.FY 26 22,5 25,2 Typ e (standard extent
in W air flow in m³/h in dm³ current in A level*
of delivery)
MT, -10°C, mid-point LT, -35°C, mid-point LHV5E/4EE-6.F1Y 312 1 x 350 5200 21 23 43
LH V5 E/4 EE-6 .F1 Y 3,3 3,2 3,5 3,44 3,48 1,84 1,77 LHV7E/4CE-6.F1Y 330 2 x 350 10400 21 24 47,5
LH V7 E/4 FE-5 .F1 Y 3,58 3,29 3,81 3,68 3,77 1,91 1,82
LHV7E/4DE-7.FY 330 2 x 350 10400 21 30 47
LH V7 E/4 EE-6 .F1 Y 3,39 3,25 3,76 3,74 3,78 1,95 1,85
LH V7 E/4 DE-5 .F1 Y 3,64 3,66 3,65 LHV7E/4CE-9.FY 330 2 x 350 10400 21 36 47,5
LH V7 E/4 CE-6 .F1 Y 3,44 3,47 3,45 LHV7E/4VE-7.FY 390 2 x 350 10400 21 25 47,5
LH V7 E/4 DE-7.FY 3,32 3,23 3,6 3,59 3,61 1,95 1,83
LHV7E/4TE-9.FY 390 2 x 350 10400 21 28 48
LH V7 E/4 C E-9 .FY 3,2 3,13 3,44 3,47 3,45 1,94 1,79
LH V7 E/4 VE-7.FY 3,41 3,36 3,41 LHV7E/4PE-12.FY 390 2 x 350 10400 21 32 48,5
Tentative data
Tentative data
LH V7 E/4 TE-9 .FY 3,37 3,29 3,35 LHV7E/4NE-14.FY 390 2 x 350 10400 21 36 49,5
LH V7 E/4 PE-1 2 .FY 3,39 3,29 3,36
*= in dB(A) at to -10 °C/tamb +32 °C 80 Hz at 10 m distance
LH V7 E/4 NE-1 4.FY 3,32 3,27 3,3 (Subject to change without notice)
16 // KP-261-2 EN KP-261-2 EN // 17
DIMENSIONS ACCESSORIES
LHV5E/LHV7E 12
1243
54
650
456
bottom view
vue de dessous
30
KEEPS THE COMPRESSOR LUBRICATED
The right oil supply to the compressor at any time with the
102
20
12
1188 81 optional oil separator with check valve in the discharge line.
CONDENSER WITH
PLASTIC-COATED/COPPER FINS
FOR IMPROVED CORROSION PROTECTION
1564
1661
1 For safe installation worldwide even in a challenging environment.
ØA
// Optional accessory
X
Y
97
RI SYSTEM
106 152
4 10 683
ØB
FOR LOW TEMPERATURE APPLICATION
ØA ØB X Y
Type OIL LEVEL MONITORING/
mm inch mm inch mm mm DIFFERENTIAL OIL PRESSURE SWITCH
LH V5 E/2 DES-3 .F1 Y 22 7/8 16 5/8 372 310 FOR SAFE ECOSTAR OPERATION
LHV5E/4FE-5.F1Y 28 1 1/8 16 5/8 375 310
LHV5E/4EE-6.F1Y 28 1 1/8 16 5/8 375 310 // Optional accessory
LHV7E/4FE-5.F1Y 28 1 1/8 16 5/8 375 310 // OLC-K1 for LHV5E/2DES-3.F1(Y)
LHV7E/4EE-6.F1Y 28 1 1/8 16 5/8 375 310 // Delta-PII for LHV5E/LHV7E
LHV7E/4DE-5.F1Y 35 1 3/8 22 7/8 383 308
LHV7E/4CE-6F.1Y 35 1 3/8 22 7/8 383 308
LHV7E/4DE-7.FY* 35 1 3/8 22 7/8 383 308
LHV7E/4CE-9.FY* 35 1 3/8 22 7/8 383 308
LHV7E/4VE-7.FY* 42 1 5/8 22 7/8 383 308
LHV7E/4TE-9.FY* 42 1 5/8 22 7/8 383 308
LHV7E/4PE-12.FY* 42 1 5/8 22 7/8 383 308
LHV7E/4NE-14.FY* 42 1 5/8 22 7/8 383 308
Tentative data
Connection positions: 1= Suction gas line, 4= Refrigerant outlet, 10= Sight glass
18 // KP-261-2 EN KP-261-2 EN // 19
ECOLITE PETROL
STATION
ALWAYS THE RIGHT CHOICE! PHARMA/
WHETHER FOR PETROL STATIONS OR CORNER SHOPS – THE BITZER ECOLITE
GUAR ANTEES EASY HANDLING AND A TIME-SAVING INSTALLATION
LABS
A perfect match: ECOLITE and petrol
stations worldwide. Always connected
with your unit and up to date thanks
to the BITZER DIGITAL NETWORK.
YOUR NEEDS
// Use in urban areas is easily possible thanks Regulation 2015/1095. The ECOLITE is the right
to the low sound level choice for long pipe runs
and varying cooling loads
// Designed for all climate zones even in rural
thanks to the oil return mode
areas: even at high ambient temperatures
and integrated VARISTEP
up to 55°C, the cooling temperature remains
>>
capacity regulation.
constant
COLD
// Heat recovery can be used to achieve the
highest system efficiency
20 // KP-261-2 EN KP-261-2 EN // 21
ALL-IN-ONE
PACK AGE: Highly efficient BITZER ECOLINE compressors with mechanical capacity
c ont r ol c ombine d wit h s ys te m- opt imis e d c onde ns e r s and
speed-controlled fans make all seven types suitable for low and
PROVEN BITZER medium temperature applications as standard.
COMPONENTS
COMI
SOON
NG
>> Due to its versatility and future-proof design,
this new series is a state-of-the-art and affor-
dable line of condensing units featuring the
latest BITZER technology.
OPER ATION AND heart of our ECOLITE. The solid and robust design combined with
proven BITZER components and versatile software functions offer a
SUSTAINABLE
RE ADY TO USE
Thanks to the large service door, all components are accessible and
maintenance is made easy. In addition, the semi-hermetic design
of the ECOLINE compressor makes repair possible, which increases
HIGHEST the sustainability of the ECOLITE condensing unit by prolonging the
operating lifetime. The option of heat recovery connections is certainly
FLE XIBILITY an additional plus for a small carbon footprint.
SUITABLE FOR thereby ensuring more efficient operation of the system, which results
in lower operation costs. The ECOLITE adapts automatically to system
ALL AREAS demands 365 days a year.
LOW SOUND
22 // KP-261-2 EN KP-261-2 EN // 23
ECOLITE: THE ADVANCED
AIR-COOLED CONDENSING UNIT SOUNDPROOF DESIGN
// The robust housing and
compressor compartment including
sound insulation is developed for
maximum sound protection
The product picture shows a fully equipped ECOLITE LHL5E unit. For the standard extent of delivery and optionally available equipment, please see the following pages.
24 // KP-261-2 EN KP-261-2 EN // 25
BITZER CONDENSING UNIT: CONTROLLER FUNCTIONS E XTENT OF DELIVERY
G
C O M IN
SOON
OPER ATION MODES VARISTEP CONTROL ECOLITE
AIR-COOLED CONDENSING UNITS LHL3E/.. LHL5E/.. LHL7E/..
// Evaporating temp. control // 1× VARISTEP
WITH ECOLINE COMPRESSORS
// Room temp. control → 50%–100% capacity modulation
// 2× VARISTEP with capacity regulator CRII (1x) S
- with 2 fans
EMERGENCY MODES Air cooled condenser with fans S
INPUTS - AC motors, speed controlled
e.g. setpoint adjustment Transducers/sensors - with 4 fans
S
- AC motors, speed controlled
Discharge line S S S
BITZER DIGITAL NETWORK:ALL-ROUND VIEW OF Unit controller fully wired switch board S S S
S = extent of delivery, *= Large application envelope - even for low temperature application no refrigerant injection needed
UP TO TEN BITZER PRODUCTS
USER DEVICES
ON THE INTERNET
26 // KP-261-2 EN KP-261-2 EN // 27
E XTR AORDINARY OPTIONAL EQUIPMENT APPLICATION R ANGE*
TO FULFILL YOUR DEMANDS
in liquid line
- mounted
Check valve* ● ● ●
- sight glasses and connection for
Condenser improved
●= option available, ○= option without extra charge, *= retrofitting not possible, 1= for R1234ze(E) tc > 70 °C/t0 > 15 °C on
to [°C]
request
Tentative data
(Subject to change without notice) LHL5E/4DES-5Y 50 Hz R134a/450A toh=20°C to Evaporating temperature [°C]
LHL7E/4NE-14Y 50 Hz R513A/R1234yf toh=20°C t amb Ambient temperature [°C]
LHL5E/4FES-3Y 50 Hz R448A/449A/454C toh=20°C toh Suction gas temperature [°C]
28 // KP-261-2 EN KP-261-2 EN // 29
ASERCOM-CERTIFIED PERFORMANCE DATA SEPR // COP
COP
The Association of European Refrigeration Component These high efforts result in the fact that only a limited MT, -10 °C, mid-point LT, -35 °C, mid-point
SEPR
Manufacturers (ASERCOM) has implemented a procedure number of condensing units can be submitted. Due to
R448A R448A
of certifying condensing units performance data. this not all BITZER products are certified yet. R134a R450A R513A R1234yf R404A R407A R407F R454C R455A R404A R407A R407F R454C R455A
R449A R449A
Performance data of condensing units which meet the strict LH L3E/
2,59 2,54 2,59 2,55 3,42 3,44 3,4 3,43 3,61 3,2 1,41 1,24 1,27 1,27 1,3 1,23
The high standard of this certification is assured by requirements carry the label “ASERCOM certified performance”. 2EES-2Y
// plausibility checks of the data performed by experts All certified condensing units and further information are listed LH L3E/
2,53 2,5 2,53 2,49 3,21 3,26 3,2 3,24 3,42 3,01 1,93 1,26 1,28 1,28 1,32 1,23
// regular random tests at independent institutes on ASERCOM web site (www.ASERCOM.org). 2D ES-2Y
LH L3E/
In the BITZER Software the 3,5 2,48 3,49 3,49 2,97 3,04 2,98 3,01 3,2 2,79 1,92 1,78 1,79 1,81 1,85 1,74
2CES-3Y
appropriate condensing units
LH L5E/
are marked with this label. 3,56 3,47 3,61 3,6 3,48 3,48 3,45 3,48 3,61 3,25 1,87 1,69 1,7 1,72 1,73 1,71
4FES-3Y
LH L5E/
3,73 3,66 3,76 3,73 3,22 3,31 3,25 3,28 3,45 3,06 1,93 1,77 1,79 1,81 1,82 1,76
4EES-4Y
LH L5E/
3,61 3,58 3,61 3,62 3,06 3,18 3,12 3,15 3,34 2,94 1,92 1,79 1,8 1,83 1,87 1,75
PERFORMANCE DATA 4D ES-5Y
LH L5E/
3,49 3,51 3,47 3,47 2,81 2,94 2,88 2,91 3,09 3,25 1,87 1,79 1,8 1,82 1,86 1,73
4CES-6Y
LH L7E/
REFRIGERATION CAPACITY Q o @ t amb 32 °C 4V E-7Y
3,67 3,54 3,7 3,71 3,34 3,5 3,48 3,55 3,51 3,18 1,94 1,85 1,88 1,88 1,82 1,81
Tentative data
30 // KP-261-2 EN KP-261-2 EN // 31
DIMENSIONS
E XPLANATION OF TYPE DESIGNATION 11 4 11
LHL3E
M8x30 (max.) Ø12 M8x30 (max.)
LHL3E / 2DES–2Y
1
Ø22
830
condenser type compressor type
568
3 = small housing
520
5 = medium housing
7 = large housing oil charge
Y=ester oil
46 459
700 Ø12
648
12 13
M20x1,5 1296 78
M25x1,5
TECHNICAL DATA 20
12
5
weight in kg max fan power
449
508
472
air flow con- receiver volume max operating sound pressure
Type (standard extent consumption in
334
denser in m³/h in dm³ current in A level*
of delivery) kW
1299
LH L3 E/2 EES-2 Y 157 0,12 3000 7,8 6,6 36,0 1310
1a
LH L5 E/4 FES-3 Y 210 0,24 6000 15 10,0 37,0 Ø22
4
Ø16
LH L5 E/4 EES-4 Y 214 0,24 6000 15 12,8 38,0 1
Ø28
1230
LH L5 E/4 C ES-6 Y 218 0,24 6000 15 18,3 39,0
775
723
575
520
LH L7 E/4 VE-7 Y 347 0,48 12000 25 17,6 41,0
12
*= in dB(A) at -10/32 °C 50 Hz at 10 m distance for R513A
5
(Subject to change without notice)
449
508
472
332
1299
1310
CONNECTIONS
1 Refrigerant inlet (suction gas line), SL
1a Heat recovery inlet (optional)
4 Refrigerant outlet, DL
4a Heat recovery outlet (optional)
Tentative data
32 // KP-261-2 EN KP-261-2 EN // 33
DIMENSIONS ACCESSORIES
G
C O M IN
319 1190
LHL7E SOON
12
1308
and opening the heat recovery piping
851
799
655
590
OIL SEPAR ATOR WITH CHECK VALVE
DEMANDING APPLICATIONS ARE
59
1190
367 529 538
NO PROBLEM
13 1824 78
No matter if there is a long pipe run or multiple evaporators,
M32x1,5
the right oil supply is provided to the compressor at all times.
11
1838
RECEIVER WITH SIGHT GLASSES,
PRESSURE RELIEF VALVE CONNECTION
AND CHECK VALVE
FOR THE HIGHEST FLEXIBILITY
CONNECTIONS // Optional accessory for LHL3E/LHL5E/LHL7E
// Check valve in liquid line
1 Refrigerant inlet (suction gas line), SL
1a Heat recovery inlet (optional) // Max. allowable pressure 32 bar
4 Refrigerant outlet, DL
4a Heat recovery outlet (optional)
11 Load suspension points
ADJUSTABLE HP/LP SWITCH
12 Plug for srewed cable gland The standard cartridge pressure switches can be replaced with
13 Cable bushing (for cables 9–17mm) adjustable HP/LP switches.
34 // KP-261-2 EN KP-261-2 EN // 35
LHE AGRI FOOD
COLD
INDIVIDUAL, EASY, STORAGE
INDUSTRY
ROOMS
HIGHLY EFFICIENT!
WHETHER FOR LOW OR MEDIUM TEMPER ATURE APPLICATIONS OR HIGH AMBIENT
T EMPER AT UR ES – T HE BITZER LHE SER IES WIT H ITS MODUL A R SYST EM Food processing industries, such as
GUARANTEES LARGE COOLING CAPACITIES, HIGH FLEXIBILITY AND SUSTAINABILITY bakery, confectionery, chocolate and
ice cream production as well as others, No matter what variety of items
require refrigeration systems. These are stored in the cold room – with
sectors need stable and accurate cool- the LHE and its semi-hermetic
ing systems that operate reliable in ECOLINE compressor technology,
all conditions globally, which the LHE the performance and reliability
series can guarantee. are ensured with the perfect cold
room temperature.
SCALABLE PERFORMANCE
VERSATILE APPLICATION AN OFFER FOR EVERY
POSSIBILITIES TYPE OF APPLICATION ACCORDING TO
// Wide variety of accessories and options, such
as VARISTEP capacity control and weather
The LHE series and its six families with BITZER
ECOLINE compressors cover a range from 0.8 to YOUR NEEDS
protection housing 60 kW in medium temperature and 0.4 to 23 kW in
// L arge range of refrigerants – including low low temperature evaporation, as well as a very low
GWP refrigerants of the A2L safety group temperature range with 2-stage compressors. LHE
offers the best options and variants regardless
// Low and medium evaporating temperature
PROCESS FLORISTRY
the installation needs. Futhermore, the series
application ranges with high ambient
fully complies with the EU Ecodesign Product
temperature up to 50°C
Regulation 2015/1095.
COOLING
36 // KP-261-2 EN KP-261-2 EN // 37
PRECISE COOLING
The LHE series is approved for operation in different applications,
WITH THE such as LT/MT and challenging environments with high ambient
temperatures. The basic version of the condensing unit is equipped
WORLDWIDE
EASY ACCESS TO
COMPONENTS
>>
ROBUST
Due to its future-proof design, this
standard series is a reliable and well-
recognised condensing unit featuring
up-to-date BITZER technology.
SUSTAINABLE
The easy access to all components and the semi-hermetic
LOW OPER ATION design of the ECOLINE compressor enables fast and
COSTS
convenient maintenance. The combination of all these
attributes increases the sustainability by prolonging the
operating lifetime.
HIGHEST EFFICIENCY IN CLASS
C APACIT Y CONTROL
The refrigeration capacity, which perfectly matches the
HIGHEST SYSTEM/ system’s demands and its operating conditions via the
mechanical stepless capacity control VARISTEP, reduces
APPLICATION operating costs to a minimum.
38 // KP-261-2 EN KP-261-2 EN // 39
LHE: THE STANDARD ACCESSORY PACK
// Made of steel
WIRING OF ELEC TRIC AL COMPONENTS
// To terminal box of compressor
// To junction box (mounted)
// Optional mounted and wired ex-factory
ELEC TRONIC SPEED CONTROL BITZER LIQUID RECEIVER WE ATHER PROTEC TION HOUSING
DEVICE FOR CONDENSER FAN // Optional: larger volume // Simple to assemble
(WINTER CONTROLLER)
// PRV connection // Robust design with compact dimensions
// Pressure range 5 to 15 bar
// Sight glass and shut-off valve
// Pressure range 8 to 25 bar
40 // KP-261-2 EN KP-261-2 EN // 41
BITZER LHE CONDENSING UNIT: BITZER DIGITAL NETWORK: ALL-ROUND VIEW
HIGH AMBIENT TEMPER ATURE OF THE HEART OF REFRIGER ATION AND A/C SYSTEMS
This provides you with important product and application-related information on all the BITZER products,
RELIABLE OPER ATION SYSTEM-OP TIMISED including, among others, data analyses and compressor operation reports.*
// At high ambient temperatures MINI-CHANNEL CONDENSER
// For best heat exchange and
HIGH REFRIGER ATION low refrigerant charge
HIGHLY EFFICIENT
E ASY HANDLING AND
ECOLINE COMPRESSORS
COMMISSIONING
// Well-known and proven
// Easy service thanks to directly
BITZER technology USER DEVICES
accessible system components
ON THE INTERNET
SPEED-CONTROLLED
EC FANS
// For efficient and low sound operation *= in combination with IQ MODULE - CM-RC-01
(optionally available/exception:
not available for LH265E)
E XTENT OF DELIVERY
LHE WITH 2-STAGE COMPRESSORS: LHE – AIR-COOLED CONDENSING UNITS LH32E/.. - LH104E/..
LH265E/..
FOR LOW TEMPER ATURE APPLICATIONS INCLUDING HIGH AMBIENT TEMPERATURE TYPES LH84E/.. - LH135E/..
- ECOLINE compressors
Semi-hermetic reciprocating compressor S S S
- 2-stage compressors
The air-cooled condensing units with
Q0 @ t0 -45 °C/ Q0 @ t0 -45 °C/
2-stage compressors from BITZER are tamb +32 °C 50 Hz in kW tamb +32 °C 50 Hz in kW - mini channel design with 1 fan
Ty p e S
convincing thanks to a compressor design, - EC motor, capable for speed control
R404A R448A/R449A, mid-point
made especially for low temperature - mini channel design with 2 fans
Air-cooled condenser S
applications. They are well combined with LH104E/S4T-5.2Y 4,05 3,36 - EC motors, capable for speed control
components like efficient condenser and LH104E/S4N-8.2Y 5,72 4,79 - with 2 fans
S
fans. Futhermore, low GWP refrigerants - AC 3 phase motors
LH124E/S4G-12.2Y 9,24 7,23
are approved for increased sustainability. Liquid receiver with shut-off valve S S S
LH135E/S6J-16.2Y 13,19 10,85
Eight types with displacement LP/HP from at receiver
LH135E/S6H-20.2Y 15,17 12,23 LH32E .. LH84E:
19.70 / 12.60 m³/h .. 101.10 / 50.50 m³/h Connection for pressure relief valve S S
additional connections at
LH135E/S6G-25.2Y 17,25 13,89
50 Hz receiver required (accessory)
LH265E/S6G-25.2Y 17,55 14,44
Discharge line - S S S
LH265E/S6F-30.2Y 20,8 17,28
BSE32 (ester oil) for HFC and HFC/HFO
Oil charge S S S
refrigerants tc < 70 °C
S = extent of delivery
(Subject to change without notice)
Tentative data
42 // KP-261-2 EN KP-261-2 EN // 43
E XTR AORDINARY OPTIONAL EQUIPMENT
TO FULFIL YOUR DEMANDS
mounted ● ● ● ● ● ●
High and low pressure switch (adjustable)
with HP safety pressure cut-out, mounted ● ● ● ● ●
1) for LH44E/..
- sight glass / sight glasses
Additional connections at receiver* ● 1)
● ● S 2) S S S 2) Standard for LH104E/..
- connection for pressure relief valve
; LH114E/..
●= option available, ○= option without extra charge, S= extent of delivery, *= retrofitting not possible, 1= for R1234ze(E) tc > 70 °C/t0 > 15 °C on request
(Subject to change without notice)
44 // KP-261-2 EN KP-261-2 EN // 45
E XTR AORDINARY OPTIONAL EQUIPMENT
TO FULFIL YOUR DEMANDS
2KES .. 2FES 2EES .. 2CES 4FES .. 4CES 4TES .. 4NES 4JE .. 4GE 6JE .. 6HE S4T .. S4N S4G S6J .. S6G
46 // KP-261-2 EN KP-261-2 EN // 47
APPLICATION R ANGE ASERCOM-CERTIFIED PERFORMANCE DATA
refrigeration capacity [kW] according to EN 13215
The Association of European Refrigeration Component These high efforts result in the fact that only a limited
Manufacturers (ASERCOM) has implemented a procedure number of condensing units can be submitted. Due to
of certifying condensing units performance data. this not all BITZER products are certified yet.
Performance data of condensing units which meet the strict
The high standard of this certification is assured by requirements carry the label “ASERCOM certified performance”.
// plausibility checks of the data performed by experts All certified condensing units and further information are listed
to=-10 °C, t amb=32 °C, toh=20 °C
please refer to
BITZER Software
APPLICATION LIMITS
t amb [°C]
60
40
30
20
LH44E / 2GES-2 Y-40S
condenser type compressor type
10
0 oil charge
Y=ester oil
-10
-45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30
motor code
Tentative data
to [°C]
LH265E/4GE-30Y 50 Hz R448A/R449A toh=20 °C to Evaporating temperature [°C]
LH135E/4PES-15Y 50 Hz R448A/R449A toh=20 °C t amb Ambient temperature [°C]
LH84E/4FES-5Y 50 Hz R134a/R513A toh=20 °C toh Suction gas temperature [°C]
48 // KP-261-2 EN KP-261-2 EN // 49
PERFORMANCE DATA TECHNICAL DATA
S TANDARD TYPES STANDARD TYPES
refrigeration sound pressure
refrigeration weight in kg
capacity Qo max fan power max condenser receiver volume max. operating level at -10/32 °C
capacity Qo best efficiency MT best efficiency LT Typ e (standard extent
Type LT to -35/tamb 32 in W air flow in m³/h in dm³ current in A 50 Hz at 10 m in
MT to-10/tamb with refrigerant with refrigerant of delivery)
°C mid point dB(A)
32 °C R513A
R448A
LH32E/2KES-05Y 71 135 1650 3 4,2 45,4
LH32E/2KES-05Y 1,26 0,43 2,09 R448A 0,99 R407F
LH32E/2JES-07Y 71 135 1650 3 5,1 45,5
LH32E/2JES-07Y 1,57 0,63 2,02 R448A 0,99 R407F
LH33E/2HES-1Y 70 135 1650 3 5,2 45,6
LH33E/2HES-1Y 2,12 0,85 2,07 R134a 1,19 R407F
LH33E/2HES-2Y 72 135 1650 3 5,9 45,6
LH33E/2HES-2Y 2,12 0,85 2,09 R407A 1,17 R407F
LH33E/2GES-2Y 72 135 1650 3 6,4 42,4
LH33E/2GES-2Y 2,45 1,01 2,05 R513A 1,21 R407F
LH44E/2GES-2Y 78 155 2000 5,6 6,4 42,4
LH44E/2GES-2Y 2,52 1,02 2,1 R513A 1,2 R407A
LH44E/2FES-2Y 77 155 2000 5,6 6,7 43
LH44E/2FES-2Y 3,07 1,29 2,19 R513A 1,25 R407F
LH44E/2FES-3Y 78 155 2000 5,6 7,5 43
LH44E/2FES-3Y 3,05 1,29 2,05 R513A 1,24 R407F
LH44E/2EES-2Y 96 155 2000 5,6 7,4 43,1
LH44E/2EES-2Y 3,66 1,61 2,27 R134a 1,3 R404A
LH53E/2DES-2Y 109 155 2600 5,6 9 44
LH53E/2DES-2Y 4,51 1,97 2,35 R134a 1,34 R404A
LH64E/2EES-3Y 121 330 4300 7,8 9 45
LH64E/2EES-3Y 4,02 1,67 2,25 R448A 1,21 R404A
LH64E/2DES-3Y 121 330 4300 7,8 10,1 45,1
LH64E/2DES-3Y 4,73 2 2,29 R513A 1,58 R449A
LH64E/2CES-3Y 119 330 4300 7,8 10,6 45,2
LH64E/2CES-3Y 5,71 2,64 3,09 R513A 1,75 R404A
LH64E/4FES-3Y 131 330 4300 7,8 11 45,6
LH64E/4FES-3Y 5,89 2,83 3,07 R513A 1,7 R404A
LH64E/4EES-4Y 133 330 4300 7,8 13,7 46,8
LH64E/4EES-4Y 7,44 3,43 3,08 R1234ze(E) 1,71 R448A
LH84E/2CES-4Y 123 340 4600 13 11,5 45,3
LH84E/2CES-4Y 5,93 2,65 3,37 R513A 1,83 R404A
LH84E/4FES-5Y 140 340 4600 13 12,3 45,7
LH84E/4FES-5Y 6,16 2,86 3,36 R513A 1,69 R449A
LH84E/4EES-6Y 140 340 4600 13 15,1 46,9
LH84E/4EES-6Y 7,86 3,56 3,37 R513A 1,82 R404A
LH84E/4DES-5Y 143 340 4600 13 16 48
LH84E/4DES-5Y 8,93 3,97 3,3 R134a 1,84 R404A
LH84E/4CES-6Y 147 340 4600 13 19,2 48,2
LH84E/4CES-6Y 10,68 5,09 3,18 R450A 1,82 R404A
LH104E/4DES-7Y 188 2 x 330 8000 15 18 48,3
LH104E/4DES-7Y 9,36 3,69 3,22 R513A 1,73 R404A
LH104E/4TES-9Y 235 2 x 330 8000 15 21,4 48,7
LH104E/4TES-9Y 13,95 6,21 3,2 R513A 1,83 R404A
LH114E/4CES-9Y 199 2 x 330 9300 15 21,7 48,6
LH114E/4CES-9Y 11,52 5,31 3,36 R513A 1,82 R404A
LH114E/4TES-12Y 251 2 x 330 9300 15 26,6 48,7
LH114E/4TES-12Y 14 6,3 3,3 R513A 1,87 R404A
LH114E/4PES-12Y 249 2 x 330 9300 15 24,2 50
LH114E/4PES-12Y 15,87 6,72 3,31 R513A 1,88 R404A
LH124E/4NES-14Y 284 2 x 330 9800 30 28,1 55,3
LH124E/4NES-14Y 18,7 8,43 3,35 R450A 1,86 R448A
LH135E/4PES-15Y 303 2 x 340 10400 30 29,8 53,4
LH135E/4PES-15Y 16,52 6,67 3,6 R513A 1,96 R404A
LH135E/4NES-20Y 306 2 x 340 10400 30 34,8 55,5
LH135E/4NES-20Y 19,42 8,67 3,52 R513A 1,98 R404A
LH135E/4JE-15Y 343 2 x 340 10400 30 32,4 50,5
LH135E/4JE-15Y 22,2 10,36 3,57 R134a 1,98 R449A
LH135E/4JE-22Y 343 2 x 340 10400 30 38,8 50,5
LH135E/4JE-22Y 21,8 9,63 3,58 R134a 1,97 R404A
LH135E/4HE-18Y 352 2 x 340 10400 30 38,3 50,9
LH135E/4HE-18Y 25,7 12,3 3,49 R1234ze(E) 1,95 R449A
LH135E/4HE-25Y 356 2 x 340 10400 30 45,6 50,9
LH135E/4HE-25Y 25,3 11,72 3,48 R1234ze(E) 1,95 R404A
LH135E/4GE-23Y 345 2 x 340 10400 30 45,5 53,5
LH135E/4GE-23Y 28,2 14,49 3,48 R1234ze(E) 1,92 R448A
LH135E/6JE-25Y 381 2 x 340 10400 30 48 52,1
LH135E/6JE-25Y 30,4 14,74 3,35 R1234ze(E) 1,94 R448A
LH135E/6HE-28Y 381 2 x 340 10400 30 54,8 54,2
LH135E/6HE-28Y 34,8 17,12 3,23 R1234ze(E) 1,86 R449A
2-STAGE
HIGH AMBIENT TEMPERATURE LH104E/S4T-5.2Y 252 2 x 330 9800 15 16 on request
LH265E/4JE-15Y 23,3 10,41 3,51 R513A 1,86 R404A
LH104E/S4N-8.2Y 257 2 x 330 9800 15 19 on request
LH265E/4JE-22Y 22,9 8,89 3,5 R513A 1,85 R404A
LH124E/S4G-12.2Y 348 2 x 330 9800 30 26 on request
LH265E/4HE-18Y 27,2 12,63 3,59 R513A 1,89 R404A
LH135E/S6J-16.2Y 395 2 x 340 10400 30 33 on request
LH265E/4GE-23Y 30,2 15,1 3,53 R513A 1,87 R449A
LH135E/S6H-20.2Y 406 2 x 340 10400 30 39 on request
LH265E/4GE-30Y 30,7 14,11 3,47 R513A 1,9 R404A
LH135E/S6G-25.2Y 419 2 x 340 10400 30 47 on request
LH265E/4FE-28Y 36,1 17,77 3,33 R513A 1,89 R448A
LH265E/4FE-35Y 35,3 17,37 3,37 R134a 1,9 R449A
LH265E/6JE-25Y 32,8 15,5 3,48 R513A 1,94 R404A
LH265E/6HE-28Y 37,9 18,16 3,43 R450A 1,92 R404A
Tentative data
Tentative data
50 // KP-261-2 EN KP-261-2 EN // 51
TECHNICAL DATA DIMENSIONS
G
LH44E/2HES-2Y 81 155 2000 5,6 5,9 43
C
LH53E/2GES-2Y 92 155 2600 5,6 6,4 44
D
LH64E/2FES-2Y 104 330 4300 7,8 7,1 45
LH64E/2EES-2Y 127 330 4300 7,8 7,8 45
30 R Ø12 T
~S
LH64E/2DES-2Y 127 330 4300 7,8 9,3 45 15 F 50 E
A H
LH84E/2CES-3Y 136 340 4600 13 10,8 45,3
4 3
LH84E/4FES-3Y 148 340 4600 13 11,2 45,7
LH104E/2DES-3Y 182 2 x 330 8000 15 10,4 46
LH104E/2CES-4Y 182 2 x 330 8000 15 11,8 46
STANDARD UNIT (high ambien t uni t s on request)
LH104E/4EES-4Y 196 2 x 330 8000 15 14 47
LH64E/4FES-3(Y) .. LH84E/4DES-5(Y) / LH84E/4CES-6(Y)
2 1 5* * 2
LH104E/4EES-6Y 198 2 x 330 8000 15 15,4 47 N B
LH114E/4FES-5Y 212 2 x 330 9300 15 12,6 48,6
LH114E/4DES-5Y 212 2 x 330 9300 15 16,3 48,6
LH114E/4DES-7Y 215 2 x 330 9300 15 18,3 48,6
LH124E/4CES-6Y 254 2 x 330 9800 30 19,5 55,3
G
LH124E/4CES-9Y 254 2 x 330 9800 30 22 55,3
C
LH124E/4TES-9Y 300 2 x 330 9800 30 21,7 55,3
LH124E/4TES-12Y 307 2 x 330 9800 30 26,9 55,3
D
LH135E/4PES-12Y 323 2 x 340 10400 30 24,7 53,4
~S
LH135E/4NES-14Y 325 2 x 340 10400 30 28,6 55,3 30 R Ø12 T
15 F 50 E
LH265E/4JE-15Y 551 2 x 760 26000 39 33 on request A H
Refrigerant outlet
LH265E/6JE-33Y 603 2 x 760 26000 39 55,5 on request
LH265E/6HE-28Y 596 2 x 760 26000 39 55,5 on request
* Option set
G
C
LH265E/6HE-35Y 607 2 x 760 26000 39 66,7 on request
D
LH265E/6GE-34Y 600 2 x 760 26000 39 67,8 on request
4
5
LH265E/6GE-40Y 610 2 x 760 26000 39 76,2 on request
~S
Connection positions:
2-STAGE
3 Condensate line
LH265E/S6G-25.2Y 605 2 x 760 26000 39 52 on request
2 Discharge line
1 Suction valve
R Ø18 T
Tentative data
Tentative data
52 // KP-261-2 EN KP-261-2 EN // 53
DIMENSIONS LH104E/S4T-5.2Y .. LH135E/S6G-25.2Y
Connections
Dimensions in mm Refrige-
Suction
Type rant
valve
outlet
A A1 B B1 C C1 D E F G H L N R S T mm inch mm inch
LH 32E/
650 630 607 645 466 574 102 505 620 406 605 62 440 82 66 133 12 1/2 10 3/8
2KES-0 5 ( Y)
LH32E/
650 630 607 645 466 574 102 505 620 406 605 62 440 82 66 133 12 1/2 10 3/8
2JES-07(Y)
LH33E/
650 630 607 645 466 574 102 505 620 406 605 62 440 82 66 133 16 5/8 10 3/8
2HES-1(Y)
LH33E/
650 630 607 645 466 574 102 505 620 406 605 62 440 82 66 133 16 5/8 10 3/8
2HES-2(Y)
LH33E/
650 630 607 645 466 574 102 505 620 406 605 62 440 82 66 133 16 5/8 10 3/8
2GES-2(Y)
LH44E/
650 630 607 645 516 574 102 505 620 456 605 62 490 82 66 133 16 5/8 10 3/8
2GES-2(Y)
LH44E/
650 630 607 645 516 574 102 505 620 456 605 62 490 82 66 133 16 5/8 10 3/8
2FES-2(Y)
LH44E/
650 630 607 645 516 574 102 505 620 456 605 62 490 82 66 133 16 5/8 10 3/8
2FES-3(Y)
LH44E/ Connection positions
650 630 702 740 516 574 121 600 620 456 700 62 490 146 82 174 22 7/8 10 3/8 1 Suction valve 5 Connection for pressure relief valve
2EES-2(Y)
2 Discharge line internal thread: 3/8-18 NPTF
LH64E/ 3 Condensate line external thread: 1 1/4-12 UNF
1000 982 672 693 687 915 121 570 970 607 670 72 750 160 102 157 22 7/8 12 1/2
2EES-3(Y) 4 Refrigerant outlet * Option set
LH53E/
1000 982 671 693 536 915 121 570 970 456 670 72 750 160 102 157 22 7/8 10 3/8
2DES-2(Y)
LH64E/
1000 982 672 693 687 915 121 570 970 607 670 72 750 160 102 157 22 7/8 12 1/2
2DES-3(Y) Connections
LH64E/ Dimensions in mm
1000 982 672 693 687 915 121 570 970 607 670 72 750 160 102 157 22 7/8 12 1/2 Suction Refrigerant
2CES-3(Y) Type
valve outlet
LH84E/
1000 982 672 693 837 915 121 570 970 757 670 72 850 160 102 157 22 7/8 12 1/2 A A1 B B1 C C1 D E F G H N R S T mm inch mm inch
2CES-4(Y)
LH64E/
1000 982 672 693 687 915 125 570 970 607 670 72 750 129 99 157 22 7/8 12 1/2 LH104E/4DES-7(Y) 1140 1280 920 1060 723 795 125 870 1060 658 886 1100 326 282 215 28 1 1/8 16 5/8
4FES-3(Y)
LH84E/
1000 982 672 693 837 915 125 570 970 757 670 72 850 129 99 157 22 7/8 12 1/2 LH114E/4CES-9(Y) 1356 1480 920 1060 773 845 125 870 1270 708 886 1310 431 282 215 28 1 1/8 16 5/8
4FES-5(Y)
LH64E/
1000 982 672 693 687 915 125 570 970 607 670 72 750 129 99 157 28 1 1/8 12 1/2 LH104E/4TES-9(Y) 1140 1280 920 1060 773 795 142 870 1060 658 886 1100 289 297 215 35 1 3/8 16 5/8
4EES-4(Y)
LH84E/
1000 982 672 693 837 915 125 570 970 757 670 72 850 129 99 157 28 1 1/8 12 1/2 LH114E/4TES-12(Y) 1356 1480 920 1060 773 845 142 870 1270 708 886 1310 394 297 215 35 1 3/8 16 5/8
4EES-6(Y)
LH84E/
1000 982 672 693 837 915 125 570 970 757 670 72 850 129 99 157 28 1 1/8 12 1/2 LH114E/4PES-12(Y) 1356 1480 920 1060 773 845 142 870 1270 708 886 1310 394 297 215 35 1 3/8 16 5/8
4DES-5(Y)
LH84E/
1000 982 672 693 837 915 125 570 970 757 670 72 850 129 99 157 28 1 1/8 12 1/2 LH135E/4PES-15(Y) 1591 1720 1000 1140 998 1070 142 950 1500 908 961 1550 502 368 230 42 1 5/8 22 7/8
4CES-6(Y)
LH124E/4NES-14(Y) 1591 1720 1000 1140 848 920 142 950 1500 758 961 1550 502 368 230 35 1 3/8 22 7/8
WE ATHER PROTECTION HOUSING LH32E .. LH135E (no t av ail able for LH265E) LH135E/4NES-20(Y) 1591 1720 1000 1140 998 1070 142 950 1500 908 961 1550 502 368 230 42 1 5/8 22 7/8
LH135E/4JE-15(Y) 1591 1720 1000 1140 998 1070 158 950 1500 908 961 1550 495 373 230 42 1 5/8 22 7/8
A1 B1
LH135E/4JE-22(Y) 1591 1720 1000 1140 998 1070 158 950 1500 908 961 1550 495 373 230 42 1 5/8 22 7/8
LH135E/4HE-18(Y) 1591 1720 1000 1140 998 1070 158 950 1500 908 961 1550 495 373 230 42 1 5/8 22 7/8
LH135E/4HE-25(Y) 1591 1720 1000 1140 998 1070 158 950 1500 908 961 1550 495 373 230 54 2 1/8 22 7/8
C1
A1, B1, C1: LH135E/4GE-23(Y) 1591 1720 1000 1140 998 1070 158 950 1500 908 961 1550 495 373 230 54 2 1/8 22 7/8
Dimensions of the appropriate
Tentative data
Tentative data
weather protection housing LH135E/6JE-25(Y) 1591 1720 1000 1140 998 1070 158 950 1500 908 961 1550 495 373 230 54 2 1/8 22 7/8
L
54 // KP-261-2 EN XX-123-1 EN // 55
DIMENSIONS ACCESSORIES
Connection positions 5 Connection for pressure relief valve
1 Suction valve internal thread: 3/8-18 NPTF
2 Discharge line external thread: 1 1/4-12 UNF
3 Condensate line 7 Refrigerant inlet at liquid subcooler
4 Refrigerant outlet 8 Refrigerant outlet at liquid subcooler
1 2
2085
ACCESSORY PACK
ALL-IN-ONE PACKAGE AND READY FOR USE
The accessory pack makes life more convenient: with its wired
and mounted components (selected kits), commissioning is not
only easy but also saves time and money.
1308
// HP/LP switches (mounted)
// Wiring to junction box/terminal box
// Liquid line with sight glass and filter dryer
// Insulated suction line to outer unit edge with LH32E .. LH84E
4 5 3
VARISTEP – MECHANICAL CAPACITY CONTROL
ADAPTATION ACCORDING TO SYSTEM
LH265E-4JE .. LH265E-4FE
2085 REQUIREMENTS
With the mechanical capacity control VARISTEP, changing
1 2
cooling demands are no problem. It prevents high switching
2085
frequencies of the compressor and ensures efficient operation
of the compressor. It is based on the principle of blocked
suction.
1150
2025 1050 BITZER: it saves time and money for the installer as well as for
the owner.
2075 1150
4 5 3
// To terminal box of compressor
// To junction box (mounted)
LH265E-S6G .. LH265E-S6F
2085
2 7 1
with the optional oil separator with check valve in the discharge line.
Tentative data
2025 1050
2075 1150
8 4 5 3
2085
56 // KP-261-2 EN KP-261-2 EN // 57
K-SERIES GROCERY
STORE +
PHARMA/
WATER-COOLED SOLUTION AT ITS BEST! SUPERMARK ET
LABS
FOR ALL COMMERCIAL REFRIGER ATION APPLICATIONS, FROM 0.3 KW UP TO
CITY
THE K-SERIES GUAR ANTEES THE BEST EFFICIENCY WHILE ENSURING HIGH WA
TER
HORECA
condenser is easy thanks to the BITZER selection
in all conditions software.
WAREHOUSE/
// Approved for common refrigerants as well as
HFO and HFC/HFO blends
COLD
// Condenser: approval according to the EU SEA
STORAGE
WA
TER
WA
IN
G
Furthermore varying cooling
Commercial refrigeration and A/C applications, loads are no problem thanks to
TO
WER
such as low and medium temperatures, are feas- the optional VARISTEP mechan-
ible. It’s a perfect fit for cold storage rooms, city ical capacity control.
Even demanding applications are no
grocery stores and convenience stores. The K-se-
problem for the K-Series. We combine
ries water-cooled condensing unit is the perfect
low and medium temperature appli-
answer to system needs and connects efficiency
cations in one condensing unit with a
and durability.
wide range of refrigerants.
58 // KP-261-2 EN KP-261-2 EN // 59
K-SERIES:
THE COMPACT
The water-cooled condensing unit is equipped with
>>
COMPACT
UNIT DESIGN
Perfectly designed for indoor or even outdoor
commercial refrigeration installations, K-series
condensing units are the answer for your system
SMALL SPACE REQUIREMENTS requirements and possible space restrictions.
ALLOW E ASY AND FLE XIBLE
PLACEMENT OF THE UNIT
PERFORMANCE
With a large range of cooling capacities from 0.3 kW up to 28 kW for
low temperatures and from 0.8 kW up to 89 kW for medium temper-
WIDE R ANGE OF atures, the ECOLINE compressor ensures the best efficiency over the
REFRIGER ATION
entire operating envelope. The optional VARISTEP mechanical capacity
modulation offers additional flexibility.
CAPACITY
COMPAC T DESIGN
E ASY SELEC TION DUE TO Horizontal shell and tube condenser, equipped with compressor and
E XTENSIVE PRODUC T PORTFOLIO several unit options, enables a very compact design with limited foot-
print for easy integration into any machine room or basement location.
VARIETY OF
COOLING AGENTS
R ANGING FROM SE AWATER, TO
FRESH WATER AND MANY MORE
60 // KP-261-2 EN KP-261-2 EN // 61
K-SERIES:
THE STANDARD WATER-COOLED
CONDENSING UNIT
The product picture shows a fully equipped K-series. For the standard extent of delivery and optionally available equipment, please see the following pages.
62 // KP-261-2 EN KP-261-2 EN // 63
BITZER KB-SERIES: BITZER DIGITAL NETWORK: ALL ROUND VIEW
SEAWATER-RESISTANT OF THE HEART OF REFRIGER ATION AND A/C SYSTEMS.
This provides you with important product and application-related information on all the BITZER products,
RELIABLE OPERATION SYSTEM-OPTIMISED including, among others, data analyses and compressor operation reports.*
// Even with seawater WATER-COOLED CONDENSER
// For best heat exchange and
HIGH REFRIGERATION low refrigerant charge
HIGHLY EFFICIENT
EASY HANDLING AND
ECOLINE COMPRESSORS
COMMISSIONING
// Well-known and proven
// Easy service thanks to directly
BITZER technology
accessible system components USER DEVICES
ON THE INTERNET
The water-cooled condensing units with SEA-WATER COOLED UNIT WITH ECOLINE
Q0 @ t0 -35°C/tc +40 °C 50 Hz in kW WATER-COOLED UNIT WITH 2-STAGE COMPRESSOR K../.. K..B*/..
2-stage compressors from BITZER are
Ty p e
convincing thanks to a compressor de- R448A, mid-point - ECOLINE compressors
Semi-hermetic reciprocating compressor S S
sign layout, made especially for low - 2-stage compressors
64 // KP-261-2 EN KP-261-2 EN // 65
E XTR AORDINARY OPTIONAL EQUIPMENT APPLICATION R ANGE
TO FULFIL YOUR DEMANDS
Warranty extension
details see price list ● ● ● ● ● ● ● ● ●
up to 5 years
mounted ● ● ● ● ●
High and low pressure switch
(adjustable) with HP safety pressure cut-out,
● 1)
● ● ● ●
mounted
Oil heater ● ● ● ● ● ● ● ●
PERFORMANCE DATA
Discharge gas temperature
PTC 140 (included in SU) ● ● ● ● ● ●
sensor
SINGLE STAGE COMPRESSORS 2-STAGE COMPRESSORS
cylinder head with PTC sensor,
Start unloader (SU) mounted control valve, enclosed ● ● ● All performance data are based on the All performance data are based on 20°C
check valve required
European Standard EN 13215: suction suction gas temperature according to
cylinder head, mounted control gas temperature 20°C with no liquid EN 12900 at 50 Hz, including system
Capacity regulator CRII (1x) valve, enclosed possible equipment ● ● ● ● ● subcooling inherently liquid subcooling based on
see KT-101
optional liquid subcooler.
Oil service valve ● ● ● ● ● ●
- liquid injection valve sized for ope- The standard performance data for water cooled condensing units according to
Liquid subcooler
ration with subcooler EN 13215 are determined at 40°C condensing temperature. With the BITZER
- complete with piping ● ● ●
- mounted SOFTWARE the data are easily calculated for many refrigerants as compressor For further details
- components assembled and
data at the same condensing temperature using the above mentioned values for please refer to
insulated
BITZER Software
suction gas temperature and liquid subcooling.
CM-RC-01 Compressor
details see price list ● ● ● ●
Module Add-on
Performance data for individual operating conditionsand 60 Hz operation see
BITZER Digital Network only with CM-RC-01 ● ● ● ● BITZER SOFTWARE.
Tentative data
●= option available, ○= option without extra charge, *= retrofitting not possible, 1) = K373H(B)/4NES-14Y / K573H(B)/4NES-20Y, Scan for
1= for R1234ze(E) tc > 70 °C/t0 > 15 °C on request, *) Exception: K1053H(B)/6FE-44(Y), K1353T(B)/6FE-50(Y) on request for A2L refrigerants additional
(Subject to change without notice)
information
66 // KP-261-2 EN KP-261-2 EN // 67
PERFORMANCE DATA TECHNICAL DATA
Capacity at MT t0 -10 °C/ tc 40 °C R134a Capacity at LT t0 -35 °C/ tc 40 °C R448A Condenser weight in kg
Type Type max. operating current in A
in kW mid- point in kW volume in dm³ (standard extent of delivery)
K073H(B)/2KES-05(Y) 1,14 0,36 K073H(B)/2KES-05(Y) 3,4 54 2,8
K073H(B)/2JES-07(Y) 1,46 0,55 K073H(B)/2JES-07(Y) 3,4 54 3,7
K073H(B)/2HES-1(Y) 2,06 0,74 K073H(B)/2HES-1(Y) 3,4 55 3,8
K073H(B)/2HES-2(Y) 2,06 0,74 K073H(B)/2HES-2(Y) 3,4 56 4,5
K073H(B)/2GES-2(Y) 2,43 0,9 K073H(B)/2GES-2(Y) 3,4 56 5
K073H(B)/2FES-2(Y) 3,06 1,15 K073H(B)/2FES-2(Y) 3,4 56 5,3
K123H(B)/2FES-3(Y) 3,04 1,15 K123H(B)/2FES-3(Y) 5,1 61 6,1
K123H(B)/2EES-2(Y) 3,75 1,5 K123H(B)/2EES-2(Y) 5,1 82 6
K123H(B)/2EES-3(Y) 3,75 1,5 K123H(B)/2EES-3(Y) 5,1 85 7,5
K123H(B)/2DES-2(Y) 4,5 1,8 K123H(B)/2DES-2(Y) 5,1 82 7,5
K123H(B)/2DES-3(Y) 4,5 1,8 K123H(B)/2DES-3(Y) 5,1 85 8,6
K123H(B)/2CES-3(Y) 5,57 2,4 K123H(B)/2CES-3(Y) 5,1 84 9,1
K203H(B)/2CES-4(Y) 5,57 2,4 K203H(B)/2CES-4(Y) 11,8 95 10
K203H(B)/4FES-3(Y) 5,78 2,58 K203H(B)/4FES-3(Y) 11,8 107 9,5
K203H(B)/4FES-5(Y) 5,77 2,58 K203H(B)/4FES-5(Y) 11,8 111 10,8
K203H(B)/4EES-4(Y) 7,65 3,2 K203H(B)/4EES-4(Y) 11,8 109 12,2
K203H(B)/4EES-6(Y) 7,65 3,2 K203H(B)/4EES-6(Y) 11,8 111 13,6
K203H(B)/4DES-5(Y) 8,85 3,62 K203H(B)/4DES-5(Y) 11,8 111 14,5
K203H(B)/4CES-6(Y) 10,97 4,82 K203H(B)/4CES-6(Y) 11,8 116 17,7
K283H(B)/4DES-7(Y) 8,85 3,62 K283H(B)/4DES-7(Y) 11,3 116 16,5
K283H(B)/4TES-9(Y) 14,04 5,68 K283H(B)/4TES-9(Y) 11,3 161 19,9
K373H(B)/4CES-9(Y) 10,97 4,82 K373H(B)/4CES-9(Y) 14,5 126 20,2
K373H(B)/4TES-12(Y) 13,68 5,67 K373H(B)/4TES-12(Y) 14,5 176 25,1
K373H(B)/4PES-12(Y) 15,87 6,01 K373H(B)/4PES-12(Y) 14,5 174 22,7
K373H(B)/4NES-14(Y) 18,89 7,72 K373H(B)/4NES-14(Y) 14,5 176 26,6
K573H(B)/4PES-15(Y) 15,49 5,93 K573H(B)/4PES-15(Y) 29,4 206 28,2
K573H(B)/4NES-20(Y) 18,67 7,81 K573H(B)/4NES-20(Y) 29,4 209 33,2
K573H(B)/4JE-15(Y) 21,8 9,39 K573H(B)/4JE-15(Y) 29,4 249 30,8
K573H(B)/4JE-22(Y) 21,3 8,58 K573H(B)/4JE-22(Y) 29,4 249 37,2
K573H(B)/4HE-18(Y) 25,9 11,46 K573H(B)/4HE-18(Y) 29,4 249 36,7
K573H(B)/4GE-23(Y) 29,2 13,86 K573H(B)/4GE-23(Y) 29,4 251 43,9
K573H(B)/6JE-25(Y) 32 14,08 K573H(B)/6JE-25(Y) 29,4 287 46,4
K813H(B)/4HE-25(Y) 25,4 10,84 K813H(B)/4HE-25(Y) 27,7 256 44
K813H(B)/4GE-30(Y) 29,6 12,78 K813H(B)/4GE-30(Y) 27,7 268 51,2
K813H(B)/6JE-33(Y) 32,2 12,63 K813H(B)/6JE-33(Y) 27,7 293 53,2
K813H(B)/6HE-28(Y) 38 16,91 K813H(B)/6HE-28(Y) 27,7 290 53,2
K813H(B)/6GE-34(Y) 43,7 21,3 K813H(B)/6GE-34(Y) 27,7 290 65,5
K1053H(B)/6HE-35(Y) 37,2 15,97 K1053H(B)/6HE-35(Y) 40 320 64,4
K1053H(B)/6FE-44(Y) 52,9 24,8 K1053H(B)/6FE-44(Y) 40 326 83,2
K1353H(B)/6GE-40(Y) 43,5 18,85 K1353H(B)/6GE-40(Y) 37 333 73,9
K1353H(B)/6FE-50(Y) 51,6 23,1 K1353H(B)/6FE-50(Y) 37 336 96,2
2-STAGE
E XPLANATION OF TYPE DESIGNATION K373H(B)/S4T-5.2(Y) 14,5 171 14
K373H(B)/S4N-8.2(Y) 14,5 176 17
Tentative data
motor code
68 // KP-261-2 EN KP-261-2 EN // 69
DIMENSIONS DIMENSIONS
K073H/2KES-05(Y) .. K203H/2CES-4(Y) Dimensions in mm
Typ e
A B C E F Ø G H I Z
3 1 2 B K 073H /2K ES-05( Y ) 602 251 413 400 212 9 102 250 190 126
Z K073H/2JES-07(Y) 602 251 413 400 212 9 102 250 190 126
K073H/2HES-1(Y) 602 251 413 400 212 9 102 250 190 126
K073H/2HES-2(Y) 602 251 413 400 212 9 102 250 190 126
K073H/2GES-2(Y) 602 251 413 400 212 9 102 250 190 126
K073H/2FES-2(Y) 602 251 413 400 212 9 102 250 190 126
C
K123H/2FES-3(Y) 852 251 435 400 275 13 227 320 348 112
K123H/2EES-2(Y) 852 323 463 400 275 13 227 320 341 163
K123H/2EES-3(Y) 852 323 463 400 275 13 227 320 341 163
K123H/2DES-2(Y) 852 323 463 400 275 13 227 320 341 163
I 9 F
K123H/2DES-3(Y) 852 323 463 400 275 13 227 320 341 163
G E H
K123H/2CES-3(Y) 852 323 463 400 275 13 227 320 341 163
A
K203H/2CES-4(Y) 863 323 528 400 275 13 238 320 308 163
K203H/4FES-3(Y) 863 345 573 400 275 13 238 320 293 185
K203H/4FES-5(Y) 863 345 573 400 275 13 238 320 293 185
K203H/4FES-3(Y) .. K813H/4GE-30(Y) K203H/4EES-4(Y) 863 345 573 400 275 13 238 320 293 185
K203H/4EES-6(Y) 863 345 573 400 275 13 238 320 293 185
3 2 1 2 K203H/4DES-5(Y) 863 345 573 400 275 13 238 320 293 185
Dimension for seawater resistant condenser design and information to fixing plates and fixing rails see DP-200
B
Z K283H/4DES-7(Y) 863 345 573 400 275 13 238 320 293 185
K203H/4CES-6(Y) 863 345 573 400 275 13 238 320 293 185
K373H/4CES-9(Y) 1113 345 573 740 275 13 193 320 382 185
K283H/4TES-9(Y) 863 363 626 400 275 13 238 320 256 204
K373H/4TES-12(Y) 1113 363 626 740 275 13 193 320 382 204
K373H/4PES-12(Y) 1113 363 626 740 275 13 193 320 382 204
C
K573H/4PES-15(Y) 1176 363 672 740 305 18 218 360 360 204
K373H/4NES-14(Y) 1113 363 626 740 275 13 193 320 382 204
K573H/4NES-20(Y) 1176 363 672 740 305 18 218 360 360 204
K573H/4JE-15(Y) 1176 439 743 740 305 18 218 360 353 230
K573H/4JE-22(Y) 1176 439 743 740 305 18 218 360 353 230
I 13 F
K573H/4HE-18(Y) 1176 439 743 740 305 18 218 360 353 230
G E H
K813H/4HE-25(Y) 1176 439 743 740 305 18 218 360 353 230
A
K573H/4GE-23(Y) 1176 439 743 740 305 18 218 360 353 230
K813H/4GE-30(Y) 1176 439 743 740 305 18 218 360 353 230
Tentative data
Tentative data
Connection positions:
1 Suction gas line
4 Refrigerant outlet
10 Sight glass
70 // KP-261-2 EN KP-261-2 EN // 71
DIMENSIONS Connection positions:
1 Suction valve
2 Discharge line
3 Refrigerant outlet
K573H/6JE-25(Y) .. K1353T*/6FE-50(Y) ACCESSORIES
3 2 1
Dimension for seawater resistant condenser design and information to fixing plates and fixing rails see DP-200
C VARISTEP – MECHANICAL CAPACITY CONTROL
ADAPTATION ACCORDING TO SYSTEM
OUT
4 Pass
REQUIREMENTS
IN
I 18 F
G E H With the mechanical capacity control VARISTEP, changing
A cooling demands are no problem. It prevents high switching
frequencies of the compressor and ensures efficient
operation of the compressor. It is based on the principle of
Dimensions in mm blocked suction.
Type
A B C E F Ø G H I Z // Refrigeration capacity range from 10%-100%
K573H/6 JE-2 5 ( Y) 1176 458 736 740 305 18 218 360 353 231 (details see KT-101) or with CM-RC-01
K813H/6JE-33(Y) 1176 458 736 740 305 18 218 360 353 231
K813H/6HE-28(Y) 1176 458 736 740 305 18 218 360 353 231
K1053H/6HE-35(Y) 1634 517 735 900 305 18 367 360 551 291
K813H/6GE-34(Y) 1176 458 736 740 305 18 218 360 353 291
K1353T/6GE-40(Y) 1634 517 797 900 305 18 367 360 551 291
K1053H/6FE-44(Y) 1634 517 735 900 305 18 367 360 551 291
K1353T/6FE-50(Y) 1634 517 797 900 305 18 367 360 551 291
Images are for illustration purposes only
K573H/S6H-20.2(Y) 1176 ~547 ~814 740 305 18 218 360 353 284
K813H/S6G-25.2(Y) 1176 ~547 ~814 740 305 18 218 360 353 284
K813H/S6F-30.2(Y) 1176 ~547 ~814 740 305 18 218 360 353 284
72 // KP-261-2 EN KP-261-2 EN // 73
BITZER DIGITAL NETWORK THE SCHAUFLER ACADEMY
CONNECTED TO YOUR BITZER PRODUCTS PRACTICABLE SOLUTIONS FOR A
BITZER Digital Network (BDN) offers you easy access to valuable digital services
CHALLENGING INDUSTRY
relating to BITZER products for refrigeration and air conditioning. This provides
you with important product and application-related information on all the BITZER At the SCHAUFLER Academy, the international seminar and training centre of BITZER, you will find German
products you’re using, including, among others, data analyses and compressor // 360° product information and English seminars and training courses regarding the handling of refrigeration and air conditioning com-
operation reports. And with it, usable findings with which you can optimise the ponents and alternative refrigerants. Not only service and installation specialists can rely on our training
// Tracking of service activities
most important aspects of the cooling systems. courses but also project engineers, planners and technical engineers.
// Operation report
// Real-time data
BITZER // Notification
PRODUCTS
The SCHAUFLER Academy offers you
// Flexible access rights training courses in small groups with
theoretical contents and practical
exercises on real training systems.
Motivated and experienced teaching
staff are available to answer questions
and respond to your needs. This
and the pleasant and professional
// Warranty extension for up to five years // Assessment services for extented lifetimes
// Free one-year warranty extension for BITZER IQ products // Retrofitting solutions for secure investments
Standing for education and knowledge
// Commissioning assistance for excellent results // Refrigerant compliance and strategy consulting
transfer, we consider it as our re-
sponsibility to provide information
about our products, applications,
tools and basics. In cases where in-
person training is not possible, we can
still provide you with some content to
learn from home or in the office with
our e-learning seminars.
bitzergreenpoint.com
74 // KP-261-2 EN KP-261-2 EN // 75
A PLUS FOR YOU
BITZER SOFTWARE
CHOOSE THE RIGHT PRODUCTS AND
FIND MORE DETAILED TECHNICAL DATA
SOFTWARE
FIND SUITABLE SPARE PARTS
log for easy maintenance and service.
LOCALLY ANCHORED.
E ASILY
76 // KP-261-2 EN KP-261-2 EN // 77