21 05 - IFC Drawings - Mechanical Legend
21 05 - IFC Drawings - Mechanical Legend
21 05 - IFC Drawings - Mechanical Legend
TW TEMPERED HOT WATER 200 QUANTITIES AS Written dimensions shall have precedence over scaled dimensions. Contractors
PLUG VALVE CAM COMPRESSED AIR METER shall verify and be responsible for all dimensions and conditions on the job, and IBI
FIRE HOSE CABINET (FHC) 400 INDICATED) Group shall be informed of any variations from the dimensions and conditions
IW IRRIGATION WATER SURFACE MOUNTED shown on the drawing. Shop drawings shall be submitted to IBI Group for general
BUTTERFLY VALVE PUMP DIFFUSERS conformance before proceeding with fabrication.
BRIN BRINE WATER
IBI Group Professional Services (Canada) Inc.
CHEM CHEMICAL WATER FIRE HOSE CABINET (FHC) BALL VALVE F&T STEAM TRAP - FLOAT & THERMOSTATIC TYPE (SEE THROAT SIZE is a member of the IBI Group of companies
AIR DISTRIBUTION L/s TOTAL
SEMI-RECESSED D SPEC)
SW SOFT WATER DIAPHRAM VALVE BOX (AIR ISSUES
B STEAM TRAP - INVERTED BUCKET QUANTITIES EQUAL No. DESCRIPTION DATE
SAN SANITARY DRAIN - ABOVE GRADE XX-150-450
FIRE HOSE CABINET (FHC) HOSE END VALVE IN ALL DIEACTIONS) 00 ISSUED FOR 2021-10-19
SAN SANITARY DRAIN - BELOW GRADE RECESSED T STEAM TRAP - THERMOSTATIC
CONSTRUCTION
SAN-P PUMPED SANITARY DRAIN BOILER BLOWDOWN VALVE LINEAR DIFFUSER
FS TH STEAM TRAP - THERMODYNAMIC
STM STORM DRAIN - ABOVE GRADE WH WALL HYDRANT
FIRE STOP VALVE No OF SLOTS PATTERN PLENUM
STM STORM DRAIN - BELOW GRADE AUTOMATIC DRAIN TRAP - COMPRESSED AIR LENGTH AIR
RHH ADT A=1/2" SLOT 1=1 WAY QUANTITY SIZE
ROOF HOSE HOUSE RUPTURE DISC B=3/4" SLOT 2=2 WAY
STM-P PUMPED STORM DRAIN [L/s]
AE AIR ELIMINATOR D=DOWNBLAST
PW PROCESS DRAIN - ABOVE GRADE VALVE IN RISER
FH FIRE HYDRANT WATER HAMMER ARRESTOR
PW PROCESS DRAIN - BELOW GRADE 3000-3A-D-250-200X150
PRESSURE REDUCING VALVE
PW-P PUMPED PROCESS DRAIN FIRE DEPARTMENT CONNECTION HS HYDRAULIC SEPERATOR
W WEEPER DRAIN (SUB-DRAIN) PRESSURE RELIEF VALVE - ELEVATION FINNED TUBE LINEAR CONVECTORS
S AAV AUTOMATIC AIR VENT
V VENT SUPERVISED VALVE
PRESSURE RELIEF VALVE TYPE FINNED ENCLOSURE KW
COND CONDENSATE DRAIN FS LENGTH HEIGHT
DRAIN OVERFLOW DRAIN FLOW SWITCH
PRESSURE RELIEF VALVE - PLAN
FLOOR DRAIN (LETTER A-900-600-0.9
FD-A FLOAT ACTIVATED SIGNAL TRANSMITTER
INDICATES TYPE SEE SPRINKLER ALARM CHECK WET VALVE
SPECIFICATION)
FFD-A
FUNNEL FLOOR DRAIN (LETTER
INDICATES TYPE SEE
FLOAT OPERATED VALVE HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT IDENTIFICATION
SPECIFICATION) SPRINKLER ALARM CHECK DRY VALVE BACK PRESSURE VALVE ITEM UNIT COUNTER
ROOF DRAIN (CONVENTIONAL) DUCTWORK
DIFFERENTIAL BACK PRESSURE VALVE (RECTANGULAR) DUCTWORK (ROUND) XX-XXX
PR PREACTION SPRINKLER ALARM CHECK VALVE
FUNNEL DRAIN - ELEVATION
NEEDLE VALVE AIR CONDITIONING AIR COOLED
M AC ACCU
HB HOSE BIBB DL DELUGE SPRINKLER ALARM CHECK VALVE BALANCING VALVE ACOUSTIC DUCT UNIT CONDENSING UNIT
MOTORIZED DAMPER INSULATION - INTERNAL
NFWH HYDRANT - NON-FREEZE BS BOILER (STEAM) BW BOILER (HOT WATER)
ALARM GONG FLOW METERING FITTING (UNDER 75mm)
SHOWER HEAD COMPUTER ROOM
FLOW METERING FITTING (75mm AND LARGER) OPPOSED BLADE DAMPER C AIR COMPRESSOR CAC
% PARALLEL BLADE DAMPER A/C UNIT
PITCH-INDICATES DOWN SLOPE
HOSE HEADER 6 x 62Ø c/w HOSE CAP CONTROL VALVE - ELECTRIC CC COOLING COIL CT COOLING TOWER
CO CLEANOUT - ABOVE GRADE FD SD
CONTROL VALVE - PNEUMATIC COMPRESSED
CO FIRE DAMPER SMOKE DAMPER D DH DOOR HEATER
CLEANOUT - ABOVE GRADE AIR DRYER
POST INDICATOR VALVE THREE-WAY CONTROL VALVE - ELECTRIC EVAPORATOR
E EAO EXHAUST AIR OUTLET
CO CLEANOUT - BELOW GRADE VD FD/SD REFRIGERATION
THREE-WAY CONTROL VALVE - PNEUMATIC
CO O.S. & Y. VALVE VOLUME DAMPER COMBINATION FIRE & EVAPORATOR
CLEANOUT - BELOW GRADE SMOKE DAMPER EC EF EXHAUST FAN
M MOTORIZED VALVE CONDENSER
RUNNING TRAP O.S. & Y. VALVE-IN RISER FAI FRESH AIR INTAKE EH ELECTRIC HEATER
S
BFP PUMP CONTROL VALVE REDUCER
VOLUME EXTRACTOR FINNED-TUBE
BACKFLOW PREVENTOR INSPECTORS TEST CONNECTION FLC LINEAR FC FAN COIL
GLOBE CONTROL VALVE - PNEUMATIC CONSULTANTS
CONVECTOR
BACK WATER VALVE (FOR SEWAGE) GRAVITY VENTILATOR
BUTTERFLY CONTROL VALVE - PNEUMATIC H HUMIDIFIER GV
TURNING VANES ELBOW (ROOF VENTILATOR)
BACKFLOW PREVENTER
(ANTI-SIPHON DEVICE 25mm &
MECHANICAL PIPING PNEUMATIC ACTUATOR DWH
DOMESTIC
HC HEATING COIL
M WATER HEATER
LARGER) ELECTRIC ACTUATOR DOMESTIC WATER
"X" PIPE SIZE NPS
X-YYY AHU AIR HANDELING UNIT DWH-I HEATER
BACKFLOW PREVENTER "Y" PIPE SERVICE CONICAL TEE FITTING
M ELECTRIC MOTOR TAP-IN FITTING INSTANTANEOUSLY
(ANTI-SIPHON DEVICE UNDER 25mm) HWS HEATING WATER SUPPLY
ELECTRIC SOLENOID M METER HX HEAT EXCHANGER
HWR HEATING WATER RETURN S
WATER CLOSET (WALL HUNG, FLUSH VALVE)
HCS HEATING / CHILLED WATER SUPPLY T ROOM THERMOSTAT MAU MAKE-UP AIR UNIT MAH MAKE-UP AIR HEATER
WATER CLOSET (FLOOR MOUNTED, FLUSH TANK) HCR HEATING / CHILLED WATER RETURN FS WYE-TEE SPLITTER DAMPER
FLOW SWITCH (HARD WIRED) MZ MULTI-ZONE UNIT MS MOISTURE SEPARATOR
GLY-HWS GLYCOL HEATING WATER SUPPLY
URINAL (WALL HUNG, FLUSH VALVE ) HLS HIGH LIMIT HUMIDITY SENSOR
GLY-HWR GLYCOL HEATING WATER RETURN GI GEASE INTERCEPTOR OI OIL INTERCEPTOR
CHWS CHILLED WATER SUPPLY DPS ROUND DUCT TURNING ROUND DUCT TURNING
DIFFERENTIAL PRESSURE SENSOR
LAVATORY (WALL HUNG ) TOWARD AWAY PHC PRE-HEAT COIL P PUMP
CHWR CHILLED WATER RETURN MS MEDIA RUN-OUT SWITCH
PCHWS PROCESS CHILLED WATER SUPPLY SUPPLY DUCT TURNING RETURN DUCT TURNING REFRIGERATION PRESSURE
LAVATORY (COUNTER TOP ) RC PRV
ELBOW TURNED TOWARD TOWARD TOWARD COMPRESSOR OR CHILLER REDUCING VALVE
PCHWR PROCESS CHILLED WATER RETURN SEAL
CTWS COOLING WATER SUPPLY ELBOW TURNED AWAY RETURN DUCT TURNING RF RETURN AIR FAN RV RELIEF VALVE
SUPPLY DUCT TURNING
SERVICE SINK AWAY AWAY
CTWR COOLING WATER RETURN TEE TURNED AWAY RP RADIANT PANELS RHC REHEAT COIL
HPST HIGH PRESSURE STEAM ACOUSTIC DUCT
GROUP WASHFOUNTAIN INSULATION INTERNAL - SILENCER RTU ROOFTOP UNIT
TEE TURNED TOWARD SF SUPPLY FAN
LPST HIGH PRESSURE STEAM SINGLE LINE
DRINKING FOUNTAIN COOLER S.COND STEAM CONDENSATE CONCENTRIC REDUCER TANK (WITHOUT BUILT- SL SILENCER
DFC-1 FLEXIBLE T
(NUMBER INDICATES TYPE - SEE SPECS.) S.COND-P PUMPED STEAM CONDENSATE FLEXIBLE DUCTWORK IN HEATER) 2021-10-19
ECCENTRIC REDUCER CONNECTION SP SUBMERSIBLE PUMP
RefL REFRIGERANT LIQUID TUF TERMINAL UNIT - FAN
ESS SAFETY SHOWER & EYE WASH STATION PIPE CAP THREADED VAV BOX WITH RHC &
RefG REFRIGERANT GAS VAV BOX WITH ATTENUATOR TU TERMINAL UNIT
ATTENUATOR WF WALL FIN RADIATION
EW EYE WASH STATION FUEL FUEL PIPE PIPE CAP WELDED PRIME CONSULTANT
UH UNIT HEATER
FOS FUEL OIL SUPPLY SM SNOW MELTING MANIFOLD IBI GROUP
PLUG VAV BOX CV CONSTANT VOLUME
FOR FUEL OIL RETURN RADIANT FLOOR 175 Galaxy Blvd, Unit 100
VM VENDING MACHINE BOX RFH
FAC CABINET FORCE FLOW HEATER HEATING MANIFOLD Toronto, ON M9W 0C9, Canada
FOV FUEL OIL VENT FLEXIBLE CONNECTION tel 416 679 1930 fax 416 675 4620
SUPPLY AIR DIFFUSER (SEE RETURN AIR GRILLE (SEE ibigroup.com
CB1 600 X 600 X 700 (H) CATCH BASIN H HUMIDIFIER LINE UNION
SPECIFICATION FOR TYPE) SPECIFICATION FOR TYPE)
ABBREVIATION
C:\Users\bingxi.liao\Documents\REVIT2020\122260-TAU-G08-General-R20_bingxi.liao.rvt
ENGINE OIL ENGINE OIL FLANGE CONNECTION DOOR GRILLE - AIR FLOW A.F.F. ABOVE FINISHED FLOOR PROJECT TITLE
CB2 IN LINE C.B. SOL 'B' SOLUBLE 'B' OIL 100 INV. EL. INVERT ELEVATION
FIGURE INDICATES
HONE HONE OIL
BLIND FLANGE
L/s
MEASURING STATION
BOTTOM OF DUCT
CITY OF TORONTO
B.O.D.EL. N.C. NORMALLY CLOSED
TD TRENCH DRAIN WITH CONTINUOUS SLOPE GASO GASOLINE ORIFICE FLANGES - ELEVATION ACCESSIBILITY UPGRADES
FAN CC COOLING COIL BOTTOM OF PIPE NON-FREEZE ROOF
MCS(LP) MACHINE COOLANT SUPPLY (LOW PRESSURE) B.O.P.EL. NFRH
QUICK CONNECTION FITTING ELEVATION HYDRANT
MCS(HP) MACHINE COOLANT SUPPLY (HIGH PRESSURE) HUMIDIFIER
+
FIRE PROTECTION MCR MACHINE COOLANT RETURN PIPE ANCHOR
PHC PREHEAT COIL ₵ EL.
CENTER LINE OF PIPE
ELEVATION
N.I.C. NOT IN CONTRACT
PROJECT ADDRESS
FP FIRE STANDPIPE N.GAS NATURAL GAS PIPE LINE GUIDE DEW POINT SENSOR +
C.C. COOLING COIL N.O. NORMALLY OPENED
DP RHC REHEAT COIL
PR PROPANE & TRANSMITTER
SP SPRINKLER PIPE PIPE LINE TRAPEZE HANGER
DFP DRY FIRE STANDPIPE CA COMPRESSED AIR PRESSURE SENSOR & CO CLEANOUT O.A. OUTSIDE AIR
EJ T THERMOSTAT P
VACU VACUUM PIPE PIPE LINE EXPANSION JOINT TRANSMITTER OPPOSED BLADE BALANCING
DSP DRY SPRINKLER PIPE O.B.B.
CTE CONNECT TO EXISTING
PREACTION PRE-ACTION PIPE MDG MEDICAL GAS PIPE EXPANSION LOOP
H HUMIDISTAT HS EF FMN SWITCH
DELUGE DELUGE PIPE O2 OXYGEN CW COLD WATER (DOMESTIC) O.E.D. OPEN ENDED DUCT
Y-TYPE STRAINER PROJECT NO:
CAG DRY SPRINKLER PIPE NO NITROUS OXIDE
LS LEVEL SWITCH CO CO SENSOR DOMESTIC WATER HEATER PHC PREHEAT COIL
9119- 19- 0162 / IBI 122260
N NITROGEN BASKET TYPE STRAINER DWH
(STORAGE TANK) DRAWN BY: CHECKED BY:
PENDENT SPRINKLER HEAD
CO2 CARBON DIOXIDE DUPLEX BASKET TYPE STRAINER M DAMPER ACTUATOR VOC VOC SENSOR DOMESTIC WATER R.A. RETURN AIR K.DURUKAN B.LIAO
DWH-I
UPRIGHT SPRINKLER HEAD CO CARBON MONOXIDE (INSTANTANEOUS)
IN-LINE SIGHT GLASS PROJECT MGR: APPROVED BY:
He HELIUM NO2 SENSOR E.A. EXHAUST AIR RHC REHEAT COIL F.BOLOURIAN S. LIU
T TEMPERATURE SENSOR NO2
CONCEALED SPRINKLER HEAD
H2 HYDROGEN GAUGE GLASS RWL RAINWATER LEADER SHEET TITLE
ARGON ARGON F.F.L. FINISHED FLOOR LEVEL
SIDEWALL SPRINKLER HEAD
DRIP PAN ELBOW MECHANICAL LEGEND
2021-10-19 10:25:49 AM
10mm
FUXTURE UNITS
EXISTING PIPING / DUCTWORK TO REMAIN F.U.
OR P PRESSURE GAUGE T.O.P. TOP OF PIPE
FE EXPOSED FIRE EXTINGUISHER X X X X NEW PIPING / DUCTWORK
HW HOT WATER (DOMESTIC) U.C. UNDER CUT SHEET NUMBER ISSUE
SCALE CHECK
FE&CAB FIRE EXTINGUISHER WITH CABINET T THERMOSTAT GAUGE
HWR HOT WATER RETURN U/S UNDER SIDE G08-G3001 00
1 in
CLIENT
OR OVERRIDE ISSUES
P PRESSURE No. DESCRIPTION DATE
SS START / STOP 00 ISSUED FOR 2021-10-19
CONSTRUCTION
ST STATUS
T TEMPERATURE
V VELOCITY / SPEED
WT WINDING TEMPERATURE
X POSITION
Y SERIAL COMM'S
BMS POINT
NOTE: IF AN INSTRUMENT IS NOT DESIGNATED AS A TRANSMITTER "X" OR AN INDICATING TRANSMITTER "Z", IT IS A SENSOR OR SWITCH, DEPENDING ON POINT TYPE.
GENERAL NOTES
1. FOR ROOF OPENING AND ROOF CURB DETAILS SEE ARCHITECTURAL DRAWINGS.
2. ALL FRESH AIR OR EXHAUST AIR LOUVRES IN BUILDING WALLS BY GENERAL TRADES UNLESS OTHERWISE NOTED. FOR DETAILS SEE ARCHITECTURAL DRAWINGS.
3. ALL STORM COLLAR FLASHINGS BY MECHANICAL FOR DETAILS OF FLASHINGS SEE ARCHITECTURAL DRAWINGS.
4. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND MEASUREMENTS AT THE SITE AND REPORT TO THE OWNER'S REPRESENTATIVE ANY DISCREPANCIES OR UNSATISFACTORY
CONDITIONS WHICH MAY ADVERSELY AFFECT THE PROPER COMPLETION OF THE WORK.
5. DIMENSIONS SHOWN ARE FOR PREFERRED LOCATION AND GENERAL ARRANGEMENT OF MECHANICAL SYSTEMS. IT SHALL REMAIN THE CONTRACTORS RESPONSIBILITY TO ENSURE
OVERALL COORDINATION OF HIS WORK WITH OTHER TRADES. SHOULD DEVIATION FROM LOCATIONS SHOWN ON DRAWINGS BECOME NECESSARY DUE TO CONFLICTS WITH OTHER
TRADES OR LOCAL PROBLEMS THEY MUST BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE FOR APPROVAL PRIOR TO PROCEEDING WITH WORK.
6. THIS IS THE STANDARD SHEET FORM NOT ALL ITEMS ARE ASSOCIATED WITH THIS PROJECT.
7. ALL EXISTING SERVICES TO REMAIN UNLESS NOTED OTHERWISE.
8. ALL SYSTEMS TO REMAIN FUNCTIONAL UNLESS PERMISSION FOR SHUTDOWN IS GRANTED BY THE OWNER.
CONSULTANTS
1. ALL SANITARY DRAINS NPS 4 SIZE & LARGER SHALL SLOPE AT 1.0%. ALL SANITARY DRAINS NPS 3 & SMALLER SHALL SLOPE AT 2%.
2. ALL PLUMBING, DRAINAGE & VENTING SHALL BE IN CONFORMANCE WITH PART 7 OF THE O.B.C. AND IS THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR.
3. ALL VENTING AND TRAP SEAL PRIMER NOT SHOWN BUT REQUIRED, SHALL BE BY PLUMBING CONTRACTOR.
4. ALL DOMESTIC COLD AND HOT WATER PIPING SHALL BE THERMALLY INSULATED.
5. ALL ABOVE GROUND HORIZONTAL RAIN WATER LEADER AND STORM DRAIN SHALL BE THERMALLY INSULATED.
1. ALL MATERIAL SHALL BE UNDERWRITER'S LABORATORIES OF CANADA (ULC) LISTED AND SHALL COMPLY WITH THE OWNER'S INSURER'S STANDARDS AND REQUIREMENTS AND LOCAL
AUTHORITIES HAVING JURISDICTION.
2. FIRE PROTECTION CONTRACTOR TO COORDINATE ON SITE WITH OTHER TRADES BEFORE ANY WORK IS DONE. ANY SERVICE RELOCATION DUE TO INSUFFICIENT COORDINATION TO BE DONE AT NO
SEAL
EXTRA COST TO THE OWNER. BEFORE PROCEEDING WITH WORK, DUCTWORK, PIPING AND ELECTRICAL DRAWINGS TO BE STUDIED BY FIRE PROTECTION CONTRACTOR. SHOP DRAWINGS TO
REFLECT COORDINATED ELEVATIONS.
3. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR SIZE AND LOCATION OF DUCTWORK, PIPING, AND LIGHTING FIXTURES, ETC.
4. DETAILED FIRE PROTECTION DESIGN SHOP DRAWINGS TO BE STAMPED BY PROFESSIONAL ENGINEER LICENSED IN ONTARIO AND TO BE SUBMITTED TO CONSULTANT AND AUTHORITY HAVING
JURISDICTION FOR REVIEW.
5. PROVIDE TYPE ABC FIRE EXTINGUISHERS AS PER ONTARIO FIRE CODE. FINAL LOCATION TO BE COORDINATED ON FIELD.
6. FIRE PROTECTION CONTRACTOR TO PROVIDE PIPE HANGERS AS PER NFPA 13.
7. FIRE PROTECTION SYSTEM SHALL BE SUPPLIED AND INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF NFPA 13. 2021-10-19
8. CONTRACTOR TO CONDUCT FLOW TEST AND USE THE RESULTS FOR HYDRAULIC CALCULATIONS.
9. HYDRAULIC CALCULATION SHALL START AT FIRE MAIN BUILDING CONNECTION. MAXIMUM SYSTEM PRESSURE TO BE 35KPA (5 PSI) LESS THAN THE PRESSURE TEST RESULT AT REQUIRED FLOW
RATE, TO ACCOUNT FOR FUTURE FLUCTUATION IN WATER SUPPLY PRESSURE .
10. PIPE DIMENSIONS TO BE DETERMINED BY THE RESULTS OF HYDRAULIC CALCULATION.
11. SPRINKLER SYSTEMS TO BE HYDRAULICALLY DESIGNED TO DELIVER THE DENSITIES OVER THE MOST REMOTE AREA AS LISTED IN THE SCHEDULE PRIME CONSULTANT
12. SPRINKLER COVERAGES INDICATED ARE TO BE CONFIRMED BY FIRE PROTECTION CONTRACTOR. IBI GROUP
13. PROVIDE SPRINKLER PROTECTION UNDER ALL PLATFORMS INCLUDING BUT NOT LIMITED TO CONVEYORS, STAIRS, CATWALKS, SHELVING PLATFORMS, OVERHEAD DOORS, MEZZANINES, DUCTS OR 175 Galaxy Blvd, Unit 100
ANY OBSTRUCTIONS WIDER THAN 1200MM. Toronto, ON M9W 0C9, Canada
14. SPRINKLER SHOWN ARE FOR COORDINATION PURPOSE ONLY. FINAL LOCATION OF THE SPRINKLERS TO BE DETERMINED BY FIRE PROTECTION CONTRACTOR BASED ON HYDRAULIC CALCULATIONS. tel 416 679 1930 fax 416 675 4620
ibigroup.com
15. USE UPRIGHT SPRINKLER IN SPACE WITHOUT CEILING.
16. LOCATE SPRINKLER HEADS IN THE CENTRE OF CEILING TILES.
C:\Users\bingxi.liao\Documents\REVIT2020\122260-TAU-G08-General-R20_bingxi.liao.rvt
17. SPRINKLER HEAD LOCATION TO BE COORDINATED WITH ARCHITECT PRIOR TO SHOP DRAWING PRODUCTION.
PROJECT TITLE
18. PIPING AND SPRINKLER HEADS MARKED FOR DEMOLITION TO BE REMOVED AND DISPOSED OF FROM SITE UNLESS OTHERWISE NOTED.
19. REFER TO EXISTING SHOP DRAWINGS. CITY OF TORONTO
20. ALL EXISTING SPRINKLERS TO BE ADJUSTED TO SUIT NEW BUILDING LAYOUT IN ACCORDANCE WITH NFPA 13.
21. PROVIDE FIRE WATCH DURING SHUT DOWN.
ACCESSIBILITY UPGRADES
SHEET 2 OF 2
10mm
SHEET NUMBER ISSUE
SCALE CHECK
G08-G3002 00