0% found this document useful (0 votes)
54 views5 pages

Software Upgrade Procedure SIAE

COMO ATUALIZAR RADIO SIAE

Uploaded by

aranhatelecom
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
54 views5 pages

Software Upgrade Procedure SIAE

COMO ATUALIZAR RADIO SIAE

Uploaded by

aranhatelecom
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

SIAE MICROELETTRONICA

HEADQUARTERS

VIA MICHELANGELO BUONARROTI, 1

20093 COLOGNO MONZESE MILANO – ITALY

TEL. +39 0227325.1

FAX +39 0225391585

Software upgrade procedure

29/07/2021
1. FOREWORD.............................................................................................................................3

2. SCOPE.....................................................................................................................................3

3. TOOLS NEEDED........................................................................................................................3

4. WARNINGS..............................................................................................................................3

5. PROCEDURE............................................................................................................................4

5.1 BOOT DOWNLOAD.......................................................................................................................4


5.2 System Version Download..........................................................................................................4

AGS20 Software Upgrade

SIAE MICROELETTRONICA Proprietary and Confidential. All rights reserved. The copyright of this document is the
property of SIAE MICROELETTRONICA. No part of this document may be copied, reprinted or reproduced in any material
Page 2 of 5 form, whether wholly or in part, without the written consent of SIAE MICROELETTRONICA. Further, the contents of this
document or the methods or techniques contained therein must not be disclosed to any person.
1. FOREWORD

Guidelines for updating firmware for Siae equipments are as follows:

1. Upgrade between minor releases is guaranteed, e.g 1.y.z to 1.y.z+n is ok

2. Upgrade between major releases is guaranteed by SIAE between successive versions,


e.g 1.y.z to 1.y+1.z

Also upgrades to 1.y+n with n>1 are normally possible but not guaranteed by SIAE.
Not guaranteed means that it has not been tested in all conditions and with all HW.

In this case SIAE should be contacted for a common assessment of the


situation.

2. SCOPE

Scope of this document is to provide a procedure that describes, step by step, how to perform
the software upgrade of AGS-20 equipment.

3. TOOLS NEEDED

A PC equipped with the “WebLCT Console” (WLC) software

Software version folders:

 bin (containing the system version)

 boot_e82115_xxyyzz (containing the boot firmware version xx.yy.zz)

The above mentioned version folders are contained in the distributed N31030 XXX.zip file
(where XXX varies depending on the distributed version).

4. WARNINGS

Before proceeding with the upgrade, the running boot version shall be verified against the one
provided. If the running version is included in the Mandatory Update list in the Release Note of
this system version, a boot download must be performed before upgrading the system version.
If the running version is not included in the Mandatory Update list in the Release Note of this
system version, the boot download must not be performed.

AGS20 Software Upgrade

SIAE MICROELETTRONICA Proprietary and Confidential. All rights reserved. The copyright of this document is the
property of SIAE MICROELETTRONICA. No part of this document may be copied, reprinted or reproduced in any material
Page 3 of 5 form, whether wholly or in part, without the written consent of SIAE MICROELETTRONICA. Further, the contents of this
document or the methods or techniques contained therein must not be disclosed to any person.
During the boot firmware download, the connection to the equipment must not be
interrupted.

5. PROCEDURE

5.1 Boot Download

Follow the steps below to perform the boot software upgrade of AGS-20 equipment.

1. Unzip files N31030 XXX.zip in a suitable directory of the PC used to perform the
upgrade.

2. Connect to the equipment using the WebLCT (login as 'System').

3. Open the Software Download window.

4. Select the file E82115.dwl (boot firmware) from the directory boot_e82115_xxyyzz.

5. Select "Only difference or not present/peripheral" as download mode.

6. Start the download and confirm by clicking on the window that pops-up.

7. At the end of the boot firmware download, the equipment Controller will automatically
restart. Wait for the restart to be completed.

5.2 System Version Download

1. Unzip files N31030 XXX.zip in a suitable directory of the PC used to perform the
upgrade.

2. Connect to the equipment using the WebLCT (login as 'System').

3. Open the Software Download window.

4. Select the file N31030.dwl (system version) from the directory bin.

5. Select "Forced" as download mode.

6. Start the download and confirm by clicking on the window that pops-up.

7. At the end of the system version download, to activate the new system version a bench
switch is required: click on “Bench switch” confirm by clicking on the window that pops-
up. Warning: the bench switch may be traffic affecting, depending on the system
version previously running

AGS20 Software Upgrade

SIAE MICROELETTRONICA Proprietary and Confidential. All rights reserved. The copyright of this document is the
property of SIAE MICROELETTRONICA. No part of this document may be copied, reprinted or reproduced in any material
Page 4 of 5 form, whether wholly or in part, without the written consent of SIAE MICROELETTRONICA. Further, the contents of this
document or the methods or techniques contained therein must not be disclosed to any person.
Note 1

On GAI0239 two different dwl have to be used

1) N31030.dwl if native TDM usage is requested

2) N31030_MonoPWE3 if PWE3 usage is requested

Note 2

Coming from a SYV less than 01.15.04, on GAI equipped with IF or E1 interfaces (GAI0239
excluded), the following upgrade procedure is required.

1) Download N31030 01.15.04 using N31030_ARI4NoPWE3.dwl

2) Bench switch

3) After restart SW_Mismatch alarm could be reported, since PWE3 is not working

4) Download N31030 01.16.00 using N31030.dwl

5) Bench Switch

AGS20 Software Upgrade

SIAE MICROELETTRONICA Proprietary and Confidential. All rights reserved. The copyright of this document is the
property of SIAE MICROELETTRONICA. No part of this document may be copied, reprinted or reproduced in any material
Page 5 of 5 form, whether wholly or in part, without the written consent of SIAE MICROELETTRONICA. Further, the contents of this
document or the methods or techniques contained therein must not be disclosed to any person.

You might also like