Optika ISview Manual
Optika ISview Manual
Instruction Manual
Key to the Instruction Manual
IS is shortened name used for OptikaISview
computer screen.
technical support:
be useful.
MAIN FEATURES OF IS........................................................................................................................4
SYSTEM REQUIREMENTS....................................................................................................................4
Image management
Image Stitching
System requirements
To use the OPTIKA camera, you need to install the camera driver and
file destination.
the desktop.
Driver installation:
check if the driver was installed properly. When the driver is installed
correctly, there is no yellow mark with the camera under the Imaging
Adjust camera parameter settings to get proper live image; live image
Start IS with the camera attached to a PC, the live image begins
IS supports multiple camera functions (Only for H series or later). Stopping the
Basic Control
White Balance to correct the live image color. To get better white
Or you can follow the [WB Wizard] to get better white balance result.
Taking Still Images and Videos
etc. If the image is in the color camera raw file format, color information
In [Use File Save Dialog] mode , a pop up file save configure window
the desired file name and directory path at this pop-up window.
[Use File Save Config] , allows the file save name to be pre-set,
format, image quantity, capturing interval time and the file save
set.
the day; “HH” indicates the hour; “mm” indicates the minutes; and
Click [Capture] to take one image with the pre-set file name.
Capturing and Saving a set of Images
executed.
interval time .
This set of image file names follows the same format as set for
In [Manual] mode, you need to click on [Video] button to start and stop
the recording.
In [Auto] mode, pre-set the number of frames or the time for videos and
compressors in PC.
Click [Browse...] to change file save destination. The default path is the
Files\OptikaISview\”.
This default destination might NOT be allowed storing files if the user is
not logged in as Administrator in Windows Vista, 7 or later. Image may not save
saving path or release this folder “Write” authority for other user
accounts.
Exposure Control
Change the Exposure time and Gain to adjust the image brightness.
Select frame speed to get different live image frame rate. Set 8-bit or 16-
Auto exposure target value: Set the reference exposure time for auto
Lock: will stop the auto exposure calculation. While auto exposure is working,
exposure time. During this, if you already see a good live image for
Adjust the exposure time manually. Two ways to change the exposure
time:
Key in the exposure time in the edit box directly , then click to
confirm it.
available for CCD cameras. For other cameras especially the CMOS
camera, the maximum exposure time is shorter than 1 second, then
previous exposure time and restart the new one immediately. For long exposure
new setting. This will help to get the new exposed image earlier. If the
exposure time is less than 2-3 seconds, it is not necessary to use it.
Gain, Frame Speed & Data Width
Color Control
To get better flat fielding result, Move the sample to a blank area first,
When the lighting is changed, re-do the [FlatFielding] to correct the uneven
or low light imaging. It helps to get better images easier and faster.
Black Level
Black level function defines the brightness level at the darkest part of the
image. In low light imaging, it can help to see more details in the dark
area.
In low light application, it usually needs quite a long exposure time to get
proper images. If you set a long exposure time at the beginning, you
might need quite a long time to find your target and get a proper image
(wait for finishing a long exposure to get a new frame image, adjust,
recommend to set a shorter exposure time, but make larger Gain and Black level first .
After you find the target, then reduce the Gain and Black level, and
increase the exposure time. This will aid in a better image acquisition.
Levels
To adjust the live image levels automatically: select [Auto] check box.
Pull the little triangles to adjust the live image levels. Move the white
move the black triangle towards right, it will reveal bright area information.
Capture Mode
include exposure time, gain, frame speed, data width, gamma, contrast,
level. It allows users to save 20 set parameters (available in Ver 3.6 or later).
Save parameter function: Enter a name for current parameter settings, click
to save it.
Calibrate Table Available calibration file list. Allow to add, edit and delete
calibration file.
2-points Circle Use center point and point on the circle to draw a circle. Give
the radius, area and perimeter of circle
3-points Circle Use 3 points on the circle to draw a circle. Give the radius,
area and perimeter of circle
Diameter Circle Draw a circle according to the diameter. Give the radius, area
and perimeter of circle
Concentric Circle Use center point and radius to draw concentric circles. Give
concentric circles’ radius, area and perimeter. Allow to do
multiple concentric circles measurement. Double clicking to
end concentric circles measurement
Polygon Measure polygon area and perimeter.
Double click on the scale to get its properties and make changes to it.
objectives and resolution (if a reducing lens is also used in your application, it also
requires you to take the calibration slide picture with the reduce lens attached).
If ONLY ONE objective and ONE resolution is used in the application, one
taken with exactly the same lens or microscope settings as the target
image taken.
length will give more accurate result than using 1 scale unit.
If you need more than one calibration file, using objective+reducing lens(if it is
scale unit and the Measure Unit used here. For example, the calibration scale
unit is 0.1mm; the Measure Unit is selected as µm; and the reference
1000 µm.
6. Click [OK] to confirm the calibration. The new calibration file named
Using the WRONG calibration file will make the measurement result
Measurement List
software allows you to export all the measurement data to TXT or Excel file.
Measurement
polygon, arc and angle measurement. The [Count] function allows you to
manually count the objects. And the [Annotate] function offers to add
Select [Annotate] and click on the image area which you prefer to add a
remark. It allows you to edit the comment, change the background color
Click [New] to create a new layer. Allow to key in the preferred name for
the new layer. It uses “Layer02”, “Layer03”... etc as the layer name by
default.
column, the selected check box means all the measurements in the
corresponding layers also display on the current layer. Uncheck the check
layer
The layer information is saved in a text file.
Click [Browse] to choose the text file saving directory and enter file
name. Then click [Save] to save the current layer information in the
text file. The layer information will be saved as “LayerInfo.txt” in Disk D by default
Click [Browse] to find the existed layer information text file. Click
[Load] to load the layer information to the current image.
On the right hand side of the live image window, some shortcuts are
View images in [Browse] panel, it displays the image File name, capturing
time, color depth (bit), picture resolution and image size. It also allows
you to add comments to any individual image. When you view this image next
Push [Levels] to get the image histogram. It allows you to adjust the
image levels. The level adjustment is the same as live image level
Push [Extend DoF] to get below dialog. Select the corresponding images
All the images in the folder will be listed on the left hand side. Click
Click [Add] to add the highlighted image to the right hand side (the
[Add all] button allows to add all the same size images in the left hand
Click [Fusion] to stack all the selected source images and get an
then click [Delete] to remove it. [Delete all] will remove all the selected
images.
Image stitching
high-resolution image.
1) Click [Open] browse the stitching source images. Select all the source
3) Click [Save] to save the stitched image in the same directory as the
Select [Use GPU] checkbox to speed up the stitching progress. This function
Then select the corresponding tools to measure the still images (get
Label
The label text will be displayed on the lower right corner of the image.
The date and time will be displayed on the top right corner of the image.
After clicking [Save], the image with the label will be saved as image
file name+ _bak. For example, the original image file name is “IS.jpg”,
then this image with a label will be saved as “IS_bak.jpg”. So the
HDR Image
High Dynamic Range (HDR) image is used to get greater dynamic range of
an image.
Take pictures for one same scene with different exposure time and load
the shortcut on the right hand side of the OptikaISview allows you to
Step 1: Open the images which are used for combination in IS, then click
Step 3: Click on one added image indicator to start applying color for it.
Click on one image indicator to select it (The selected one will be in dark
image.
Step 4: Click on [Apply All] to combine all the colored images.
[Sharp] function in [Image Processing] can help to get sharper images and see
If add wrong image or wrong color to selected image, just click on the
tiny cross beside each indicator to delete it. If want to cancel current
Original images:
Combined image: