ProxySG SWG Gen2 Initial Configuration Guide
ProxySG SWG Gen2 Initial Configuration Guide
ProxySG SWG Gen2 Initial Configuration Guide
Virtual Appliance
Initial Configuration Guide
for High-Performance Models
Platform: VMware vSphere Hypervisor
Broadcom, the pulse logo, Connecting everything, and Symantec are among the trademarks of Broadcom. The term “Broadcom” refers to
Broadcom Inc. and/or its subsidiaries.
The term “Broadcom” refers to Broadcom Inc. and/or its subsidiaries. For more information, please visit www.broadcom.com.
Broadcom reserves the right to make changes without further notice to any products or data herein to improve reliability, function, or
design. Information furnished by Broadcom is believed to be accurate and reliable. However, Broadcom does not assume any liability
arising out of the application or use of this information, nor the application or use of any product or circuit described herein, neither does
it convey any license under its patent rights nor the rights of others.
Additional Restrictions
ProxySG Appliances
Within sixty (60) days of the date from which the User powers up the ProxySG appliance (“Activation Period”), the Administrator must
complete the ProxySG licensing requirements as instructed by the ProxySG to continue to use all of the ProxySG features. Prior to the
expiration of the Activation Period, the ProxySG software will deliver notices to install the license each time the Administrator logs in to
manage the product. Failure to install the license prior to the expiration of the Activation Period may result in some ProxySG features
becoming inoperable until the Administrator has completed licensing.
Proxy Client:
The Administrator may install the Proxy Client only on the number of personal computers licensed to them. Each personal computer shall
count as one “user” or “seat.” The ProxyClient software may only be used with Blue Coat ProxySG appliances. The Administrator shall
require each user of the Blue Coat ProxyClient software to agree to a license agreement that is at least as protective of Blue Coat and the
Blue Coat ProxyClient software as the Blue Coat EULA.
The ProxySG Virtual Appliances (MACH5 or Secure Web Gateway edition) are licensed on either a perpetual or subscription basis for a
maximum number of concurrent users. Support for the Virtual Appliances will be subject to the separate support agreement entered into
by the parties if the Administrator licenses the Virtual Appliances on a perpetual basis. The Virtual Appliances will (a) not function upon
expiration of the subscription if the Administrator licenses the Virtual Appliances on a subscription basis; or (b) if the traffic exceeds the
maximum number of concurrent users/connections, features may not function beyond the maximum number of concurrent
users/connections. This means that, in these cases, the network traffic will only be affected by the default policy set by the Administrator
(either pass or deny). Such cessation of functionality is by design, and is not a defect in the Virtual Appliances. The Administrator may not
install the same license key or serial number on more than one instance of the Virtual Appliance. The Administrator may move the Virtual
Appliance along with its license key and serial number to a different server, provided that server is also owned by the Administrator and
the Administrator permanently deletes the prior instance of the Virtual Appliance on the server on which it was prior installed. The
Virtual Appliances require a third party environment that includes software and/or hardware not provided by Blue Coat, which the
Administrator will purchase or license separately. Blue Coat has no liability for such third party products.
ii
Contents
Contents
Chapter 1: Overview
About This Guide ............................................................................................................................... 8
Conventions Used in This Guide ..................................................................................................... 9
Terminology ...................................................................................................................................... 10
iii
Initial Configuration Guide for SWG VA High-Performance Models
iv
Chapter 1: Overview
The Secure Web Gateway Virtual Appliance (SWG VA) is a software solution
that can be installed and deployed on a server running VMware vSphere
Hypervisor. SWG VA facilitates server consolidation by co-existing with other
virtual machines on a single hardware platform, including Symantec Content
Analysis and Blue Coat ProxySG Virtual Appliance MACH5 Edition. With the
SWG VA providing security, the other virtual machines can provide branch
office services (such as Domain Controller, print, DNS, and DHCP), as well as
any VMware-certified software applications.
Symantec is VMware Ready™, having worked closely with VMware to ensure
that the SWG VA runs efficiently in the virtual environment and meets all
technical criteria and specifications.
7
Initial Configuration Guide for SWG VA High-Performance Models
8
Overview
Convention Example
Terms that identify buttons, fields, menus, or options 1. Select Maintenance > Licensing > Install.
on the user are shown in bold Arial font. 2. Click Retrieve.
Text that you must type exactly is denoted using Enter https://
bold, Courier New font. <ProxySG_IP_address>:8082/mgmt
9
Initial Configuration Guide for SWG VA High-Performance Models
Section 3 Terminology
The following table lists the terms used in this guide.
Term Definition
Appliance Serial A string of numbers that uniquely identify a virtual appliance. On the first
Number bootup, you must enter the appliance serial number to begin initial
configuration on the SWG VA. High-performance model serial numbers have
“59” as the middle digits.
Enable Mode A mode that allows administrative privileges on the command line interface
(CLI) of the ProxySG appliance. You can make changes to the configuration in
this mode.
Enable Password A password used to enter enable mode so that you can modify settings and
configure an appliance. Enable mode is for administrators who are
authorized to configure an appliance.
VMware vSphere The physical computer (host server) on which VMware’s virtualization
Hypervisor product is installed. The vSphere Hypervisor provides CPU and memory
resources, access to storage, and network connectivity to multiple virtual
machines.
OVF Open Virtualization Format. A format for packaging and distributing virtual
machines. The OVF file in the Virtual Appliance Package (VAP) is an XML
text file that defines the attributes of a specific virtual machine package.
SWG VA A ProxySG with a Secure Web Gateway (SWG) license running as a virtual
appliance on VMware’s vSphere Hypervisor.
10
Overview
Term Definition
VAP The Virtual Appliance Package is the zip file that contains the OVF file and
the virtual disk file (.vmdk) required for creating the SWG VA. It also includes
a PDF of this guide, the Initial Configuration Guide for SWG VA High-
Performance Models.
Virtual Machine An instance of an operating system and one or more applications that run in
an isolated partition of a VMware vSphere Hypervisor. SWG VA is a virtual
machine.
VLAN Virtual Local Area Network. A local area network (LAN) that is created with
software. It maps clients (hosts) logically rather than physically, and extends
across LAN segments instead of remaining in one physical LAN.
11
Initial Configuration Guide for SWG VA High-Performance Models
12
Chapter 2: Before You Begin
This chapter assumes that you have configured your hardware platform as a
VMware vSphere Hypervisor, created datastores, and configured the vSphere
Hypervisor for network access. For information on setting up your vSphere
Hypervisor, refer to VMware documentation.
Before you proceed with creating the Secure Web Gateway Virtual Appliance
(SWG VA), perform the following tasks:
❐ "Verify Support for VMware Products" on page 14
❐ "Verify System Requirements" on page 15
❐ "Verify Resource Availability" on page 17
❐ "Retrieve Appliance Serial Numbers" on page 19
❐ "Create a Virtual Switch" on page 21
Note: The instructions in this document are for vSphere Client version 5.5.
13
Initial Configuration Guide for SWG VA High-Performance Models
6.7.x, 7.1.x, and 7.2.x ESXi 5.5, 6.0, 6.5, and 6.7
14
Before You Begin
Resource Requirement
The following table lists requirements for each model, including recommended
and alternate virtual drive configurations. Symantec recommends creating 100GB
virtual drives, although models with higher storage requirements can have larger
drives. Note that each virtual drive must be the same size.
Note: After you have deployed your virtual appliance, you should have the
number of virtual disks that the model requires (listed in the following table) plus
a boot disk. The boot disk is automatically created during deployment.
15
Initial Configuration Guide for SWG VA High-Performance Models
Note: With fewer disks, more throughput is required per disk. See “Throughput
Requirements Per Virtual Disk” on page 55 for disk read and write throughput
rates per disk.
16
Before You Begin
17
Initial Configuration Guide for SWG VA High-Performance Models
2. To display the summary of the vSphere Hypervisor’s resources, select the ESX
server and click the Summary tab.
18
Before You Begin
Note: Be sure to use the correct serial number for your SWG VA. It helps ensure
that your license is valid.
b. Click Next.
The License Agreement page displays.
5. Read and accept the License Agreement.
a. Read the license agreement.
b. Select I accept at the bottom of the page.
c. Click Next.
A serial numbers page displays.
6. Record the appliance serial number(s). You will refer to the serial number
when you perform initial configuration on the SWG VA.
Perform one of the following tasks to note the appliance serial number:
• Write down the serial number(s) listed on the screen.
• Download a comma-separated values (CSV) file containing all of the serial
numbers. Click the link beside Download as CSV file and save the file to disk.
19
Initial Configuration Guide for SWG VA High-Performance Models
For future reference, record the location and name of the SWG VA with the
serial number.
Connection Limits
The SWG VA supports a maximum number of concurrent connections and
enforces this by limiting the number of unique clients. Connections will be
queued after the connection limit is reached.
Use the show license CLI command to verify the number of concurrent users (i.e.,
connections) your SWG VA is licensed for.
To upgrade the connection limit for your SWG VA, see "How do I upgrade the
connection limit for the SWG VA?" on page 51. Note that you will need to reboot
after upgrading the license to reset the connection limits.
20
Before You Begin
Note: If you use VLANs for segregating traffic within the vSphere Hypervisor or
across your network, you must enable VLAN trunking on all interconnecting
devices such as switches or routers. This guide does not include information on
VLAN configurations.
Note: This guide assumes that you do not use VLANs. If you use VLANs,
select All (4095) to enable VLAN trunking. This value enables Virtual Guest
Machine Tagging mode on the switch, and allows the virtual switch to
preserve VLAN tags between the virtual machine and the external switch/
router.
8. Click Next.
21
Initial Configuration Guide for SWG VA High-Performance Models
22
Chapter 3: Create the SWG VA
Note: The instructions in this chapter are for vSphere Client version 5.5.
23
Initial Configuration Guide for SWG VA High-Performance Models
Note: If the VM is running ESXi 6.x, use the OVF file with “ESXi6.x” in its name
in "Deploy a SWG VA" on page 26.
Note: If you have already downloaded the VAP, skip this procedure and
proceed to "Deploy a SWG VA" on page 26.
Note: The first time you download files, you are prompted to install the
Download Manager. Follow the onscreen prompts to download and run the
installer. For more information, refer to https://www.symantec.com/
support-center/getting-started.
24
Create the SWG VA
Note: Because the .ovf file includes a pointer to the .vmdk file, you must
extract and store the contents of the .zip file within the same folder. Do not
rename the files.
25
Initial Configuration Guide for SWG VA High-Performance Models
Note: The equivalent command in VI Client is File > Virtual Appliance >
Import.
c. In the Deploy from a file or URL field, browse to the location of the OVF
file.
Alternatively, copy and paste the URL of an OVF file.
Click Next.
d. Verify the OVF template details and click Next.
e. Enter a name for the SWG VA, such as SGVA_Sydney. (The default
name is ProxySG Model SWG). You should enter a name that is unique
within your vSphere Hypervisor host.
f. Select an Inventory Location. Click Next.
g. In the Configuration dialog, select the SWG VA model, for example, SG-
VA-C2S.
26
Create the SWG VA
h. In the Storage dialog, select a datastore with sufficient free space for
your SWG VA model. See Table 2–2, "Model-Specific Requirements" on
page 16 for disk space requirements. Click Next.
i. In the Disk Format dialog, select one of the thick provisioning types for
the virtual disk format and click Next.
j. In the Network Mapping dialog, specify the networks for each interface.
k. Click Next.
l. Review the deployment settings and click Finish to begin creating the
SWG VA.
See the Recent Tasks panel for the progress bar indicating the
percentage complete.
2. (Required only if you plan to use the third and fourth interfaces) Enable the
vSwitch for the third and fourth interfaces.
a. Select the SWG VA on the vSphere Hypervisor Server.
b. Right click and select Edit Settings.
c. Select Hardware > Network Adapter 3.
d. In the Device Status panel, mark the Connect at power on check box.
If necessary, repeat these steps for the fourth interface.
e. Click OK.
Note: When the VA is first imported, it has one 100 GB data drive
attached. Depending on your SWG VA model, you may need to create
additional virtual disks. For example, the SG-VA-C16S requires 800 GB of
storage space so you must create additional drives, with each drive being
the same size. See Table 2–2, "Model-Specific Requirements" on page 16.
27
Initial Configuration Guide for SWG VA High-Performance Models
i. Click Finish.
j. Repeat steps 3a–3i for each virtual disk that your SWG VA model
requires.
4. Click OK to close the Virtual Machine Properties window.
28
Create the SWG VA
d. Specify the Reservation value for the CPU that you determined in Step
1e. Ensure this value is larger than the minimum specified in "Verify
System Requirements" on page 15 ; for example, change the Reservation
value to 5200 MHz.
Retain the default values for the other options.
3. Specify the memory reservation for the SWG VA.
29
Initial Configuration Guide for SWG VA High-Performance Models
b. Specify the Reservation value for memory allotted to the SWG VA.
Input the value for Virtual Memory recommended for your SWG VA
model; see Table 2–2, "Model-Specific Requirements" on page 16.
Retain the default values for the other options.
4. Recommended if the SWG VA’s datastore is shared by other virtual machines
on the vSphere Hypervisor Server:
Give the virtual disks on the SWG VA a higher priority access to the physical
disks on the vSphere Hypervisor Server.
a. On the Resources tab, select Disk.
b. For each virtual drive, change the value to High in the Shares field.
Setting this value to high ensures that the SWG VA gains higher
priority access to disk resources, as compared to other virtual
machines that use the same physical disks.
5. Click OK to save your settings.
For additional settings you may want to modify, see "Optional Settings for
Optimal Performance" on page 56.
30
Create the SWG VA
31
Initial Configuration Guide for SWG VA High-Performance Models
32
Chapter 4: Configure the SWG Virtual Appliance
This chapter describes how to perform the initial setup and configuration of the
Secure Web Gateway Virtual Appliance (SWG VA) for transparent redirection
of traffic. The following topics are covered in this chapter:
❐ "Prepare for Initial Configuration" on page 34
❐ "Complete Initial Configuration" on page 35
❐ "Verify Your Configuration" on page 39
❐ "Retrieve and Install the SWG VA License" on page 40
❐ "When to Power Off the SWG VA" on page 42
❐ "Monitor the SWG VA" on page 43
❐ "Additional References" on page 45
Note: The instructions in this chapter are for vSphere Client version 5.5.
33
Initial Configuration Guide for SWG VA High-Performance Models
Primary DNS server Provide the IP address for the primary DNS server.
Administrator The password you assign here will also be used for
username (ID) and accessing enable mode in the command line interface
password (CLI). Enable mode allows you to make
configuration changes.
The default enable username is admin.
34
Configure the SWG Virtual Appliance
2. Access the virtual console of the SWG VA on the vSphere Hypervisor Server.
a. Select the SWG VA on the vSphere Hypervisor Server.
b. Select the Console tab and click inside the console window to activate
your mouse.
3. The appliance serial number is unique for each appliance and must be used on
only one SWG VA. For more information, see "Retrieve Appliance Serial
Numbers" on page 19.
a. Enter the appliance serial number at the prompt.
Note: The leading zeros are significant for serial numbers. Enter all 10
digits at the prompt.
b. Press Enter.
4. Follow the prompts and enter the details in the setup script.
a. Press Enter three times to activate the serial console.
Note: To release the mouse from the VMware client’s Console tab, press
Ctrl+Alt.
b. When asked How do you plan to configure this appliance? specify your
preference for either configuring the SWG VA manually or using
Director.
If you are using Director, assign a registration password on Director
and enter the password in the setup console when prompted. For
information on setting up a registration password, refer to the
Symantec Director Configuration and Management Guide.
c. At the Enter interface number to configure prompt, specify an interface.
35
Initial Configuration Guide for SWG VA High-Performance Models
36
Configure the SWG Virtual Appliance
Note: If you have this type of deployment and do not perform these steps, the
SWG VA will be unable to connect to the server and the license may be
suspended.
Note: If you do not want to forward all client HTTP requests to the hosts
specified in the sequence, do not enter the default-sequence add
<host_alias> command shown below. Instead, you will configure policy to
use the forwarding host. For more information on forwarding and proxy
chaining, refer to the SGOS Administration Guide.
#conf t
Enter configuration commands, one per line. End with CTRL-Z.
#(config)forwarding
#(config forwarding)create host <host_alias> <host_name> http proxy
ok
#(config forwarding)default-sequence add <host_alias>
ok
37
Initial Configuration Guide for SWG VA High-Performance Models
In the policy above, <host_alias> is the forwarding host you configured in the
CLI.
38
Configure the SWG Virtual Appliance
Note: When you enter the URL for the Management Console, the browser
may display an error about an untrusted connection or security certificate.
Depending on the browser you use, you must proceed with the connection to
access the Management Console or add an exception to allow access to the
web site. For specific instructions, refer to the documentation for the browser.
2. In the prompt that appears, enter the user name and password that you
created in "Complete Initial Configuration" on page 35. The Management
Console displays.
39
Initial Configuration Guide for SWG VA High-Performance Models
Note: If the SWG VA is a downstream proxy and cannot access these servers
directly, make sure you have performed the additional configuration steps in
"Upgrade and Downgrade Considerations" on page 53 before completing the
procedure below.
The SWG VA license contains data that is used to uniquely identify the SWG VA
as a Blue Coat appliance.
Note: If a license is not installed, after you power on the appliance, users who
open a browser window will see an exception page indicating that the device is
not licensed.
Note: If you have blocked the Symantec NTP servers, add a local server.
2. Click Retrieve.
40
Configure the SWG Virtual Appliance
Note: The Symantec WebFilter (formerly BCWF) license is not included with the
high-performance models of SWG VA and must be purchased separately.
41
Initial Configuration Guide for SWG VA High-Performance Models
Note: Symantec recommends that you use the shutdown command instead of
powering off the SWG VA using the vSphere client to avoid losing recent
configuration changes.
42
Configure the SWG Virtual Appliance
43
Initial Configuration Guide for SWG VA High-Performance Models
If the connection to the license validation server is lost, the State field (Statistics
> Health Monitoring > Licensing) displays the health state and the Value field
displays the number of days remaining until the license is suspended. The
health state depends on the threshold that is set:
• Warning—Default interval is six days before license suspension.
• Critical—Default interval is 0 days before license suspension.
If there is an error with the communication status, re-establish connection to
the license validation server. The state returns to OK if connection is successful.
If you do not re-establish the connection within seven days, the SWG VA
license is suspended. The SWG VA must communicate successfully with the
license validation server to restore proxy functionality.
❐ License Validation Status—Monitors the validity of the SWG VA license,
ensuring no duplicate serial numbers are in use.
If the license validation server detects a duplicate serial number, the State field
(Statistics > Health Monitoring > Licensing) displays the health state and the Value
field displays the number of days remaining until the license is suspended.
The health state depends on the threshold that is set:
• Warning—Default interval is 30 days before license suspension.
• Critical—Default interval is 0 days before license suspension.
If the license validation server detects a duplicate license and the license is not
disabled before the grace period expires, the license is suspended. You must
delete the SWG VA with the duplicate license to restore proxy functionality.
❐ Configured CPU Count— The number of configured CPUs on the virtual
appliance is compared to the number available on the license. For example, if
the SWG VA is licensed for eight CPUs and only six are configured, the
appliance has under-provisioned CPUs. Or if the SWG VA is licensed for two
CPUs and three are configured, the appliance has over-provisioned CPUs. Use
the show license CLI command to see the maximum CPU count in your
license.
• Warning:
The SWG VA has under-provisioned CPUs and is not taking
advantage of all CPUs included with the license.
• Critical: The SWG VA has over-provisioned CPUs and exceeds the licensed
maximum limit. The license is suspended until you reduce the configured
CPU count or install a different license that has a higher CPU count.
❐ Configured Memory— The amount of configured virtual memory is compared to
the amount allowed by the license. For example, if the SWG VA is licensed for
32 GB of virtual memory and is configured for 24 GB, the appliance has
under-provisioned memory.
• Warning:
The SWG VA has under-provisioned memory and is not taking
advantage of all virtual memory included with the license. To reprovision
memory, edit the hardware settings for the SWG VA.
44
Configure the SWG Virtual Appliance
45
Initial Configuration Guide for SWG VA High-Performance Models
46
Appendix A: Supplemental Information
This appendix answers some questions you may have about the following
topics and the SWG VA:
❐ "Features" on page 48
❐ "Serial Numbers and Licensing" on page 50
❐ "Upgrade and Downgrade Considerations" on page 53
❐ "Throughput Requirements Per Virtual Disk" on page 55
❐ "Optional Settings for Optimal Performance" on page 56
47
Initial Configuration Guide for SWG VA High-Performance Models
Section 1 Features
This section covers the following topics:
❐ "How do features vary between the various ProxySG editions and licenses?"
on page 48
❐ "Can I manage SWG VA using Sky UI?" on page 49
48
Supplemental Information
Table A-1
49
Initial Configuration Guide for SWG VA High-Performance Models
50
Supplemental Information
Note: You cannot request a user limit upgrade and renew a subscription on a
single order; the upgrade and renewal must be on separate orders.
51
Initial Configuration Guide for SWG VA High-Performance Models
9. To verify that the connection limit for the SWG VA has been upgraded, click
the View tab and confirm that the number of concurrent users has increased.
Note: You cannot request a connection limit upgrade and renew a subscription
on a single order; the upgrade and renewal must be on separate orders.
52
Supplemental Information
Note: Upgrading a MACH5 VA or SWG V100 to SGOS 6.7 will not convert the
VA to a high-performance model. You must purchase a new license to use a high-
performance model.
• You do not require a VAP to upgrade SGOS on the VA; VAPs are used for initial
configuration only. The upgrade process for a VA is the same as for a physical
appliance. See the ProxySG Upgrade/Downgrade WebGuide for details.
Upgrade SGOS
Upgrading the SGOS version consists of associating the activation code with the
existing serial number, and then rebooting the appliance to apply changes.
Use the procedure outlined in "Upgrade the VA Model" below, but skip steps 7
through 9 because they are needed only for VA model upgrades.
53
Initial Configuration Guide for SWG VA High-Performance Models
9. Follow the instructions in "Reserve Resources for the SWG VA" on page 29 to
specify additional CPU cores, memory, and disks as allowed by the upgraded
model. Note that over-provisioning CPUs can cause license suspension, but
under-provisioning can cause sub-optimal VA performance and operation.
See "Verify System Requirements" on page 15 for details.
10. Reboot the appliance.
11. Check the appliance health status. If you encounter health warnings or errors,
see in "Serial Numbers and Licensing" on page 50. Alternatively, search for
Symantec knowledge base articles:
https://support.symantec.com/en_US/proxysg.html
54
Supplemental Information
Model Number of Drive Size Disk Read Disk Write Read Request Write
Drives (GB) Throughput Throughput Rate (IOPS) Request Rate
(Mbps) (Mbps) (IOPS)
Model Number of Drive Size Disk Read Disk Write Read Request Write
Drives (GB) Throughput Throughput Rate (IOPS) Request Rate
(Mbps) (Mbps) (IOPS)
Model Number of Drive Size Disk Read Disk Write Read Request Write
Drives (GB) Throughput Throughput Rate Request Rate
(Mbps) (Mbps) (IOPS) (IOPS)
55
Initial Configuration Guide for SWG VA High-Performance Models
Note: The following settings could negatively impact other virtual machines on
your ESX server.
56
Supplemental Information
Set the CPU Scheduling Affinity to the logical processors on the same CPU. For
example, if the host has 24 processors per socket, the scheduling affinity is set to
any of the 24 logical processors on CPU0.
The NUMA Memory Affinity should be set to use memory from Node 0.
57
Initial Configuration Guide for SWG VA High-Performance Models
58
Supplemental Information
59
Initial Configuration Guide for SWG VA High-Performance Models
60