IPS ACADEMY

INSTITUTE OF ENGINEERING AND SCIENCE


(A UGC Autonomous Institute, Affiliated to RGPV)
Electrical & Electronics Engineering Department
SESSION 2024-25
Home Assignment-1

CLASS - B.TECH. IV YEAR (VII SEM) BRANCH- EEE


Subject Name- Power System Protection Subject Code- PCC-EEE701

Q.1. A 50MVA, 33KV generator has a reactance of 0.1 pu referred to this rating as buses.
Determine the per unit reactance when referred to base KVA of 50,000 KVA and base KV of
66KV.

Q.2. Explain symmetrical components of three phase systems.


Q.3 . Derive the necessary equation to determine the fault current for a double line to ground fault.

IPS ACADEMY
INSTITUTE OF ENGINEERING AND SCIENCE
(A UGC Autonomous Institute, Affiliated to RGPV)
Electrical & Electronics Engineering Department
SESSION 2024-25
Home Assignment-2

CLASS - B.TECH. IV YEAR (VII SEM) BRANCH- EEE


Subject Name- Power System Protection Subject Code- PCC-EEE701

Q.1. Define the following terms:

a) Plug Setting Multiplier


b) Current Setting of a relay

c) Time Multiplier setting

Q.2. Explain the distance relay protection scheme.

Q.3. Explain V-I and Polar Characteristics of a directional relay.


IPS ACADEMY
INSTITUTE OF ENGINEERING AND SCIENCE
(A UGC Autonomous Institute, Affiliated to RGPV)
Electrical & Electronics Engineering Department
SESSION 2024-25
Home Assignment-3

CLASS - B.TECH. IV YEAR (VII SEM) BRANCH- EEE


Subject Name- Power System Protection Subject Code- PCC-EEE701

Q.1. Describe the protection scheme of for internal fault in a three phase delta/star connected
power transformer.

Q.2. Write short notes on the following

a) Bucholz Relay

b) Biased differential Protection


Q.3. Explain the protection of a three phase star-connected generator by means of a percentage
differential relay.

IPS ACADEMY
INSTITUTE OF ENGINEERING AND SCIENCE
(A UGC Autonomous Institute, Affiliated to RGPV)
Electrical & Electronics Engineering Department
SESSION 2024-25
Home Assignment-4

CLASS - B.TECH. IV YEAR (VII SEM) BRANCH- EEE


Subject Name- Power System Protection Subject Code- PCC-EEE701

Q.1. Explain the working principle of air break circuit breaker.

Q.2. Write short notes on the following

a) Classification of circuit breakers

b) Maintenance of oil circuit breakers


Q.3. Describe the properties of Sulphur hexafluoride circuit breakers.
IPS ACADEMY
INSTITUTE OF ENGINEERING AND SCIENCE
(A UGC Autonomous Institute, Affiliated to RGPV)
Electrical & Electronics Engineering Department
SESSION 2024-25
Home Assignment-5

CLASS - B.TECH. IV YEAR (VII SEM) BRANCH- EEE


Subject Name- Power System Protection Subject Code- PCC-EEE701

Q.1. Write shot notes on the following:


a) microprocessor and computer based protection schemes
b) Static relay
Q.2. Explain the procedure of testing of insulators and bushings, and testing of isolators.

You might also like