Specimen Dimensions For - Testing
Specimen Dimensions For - Testing
Specimen Dimensions For - Testing
Tensile Strength
Fiber Orientation Width, mm [in.] Overall Length, mm [in.] Thickness, mm [in.] Tab Length, mm [in.] Tab Thickness, mm [in.] Tab Bevel Angle, ° Test Samples
0° unidirectional 25 [1.0] 250 [10.0] 2.5 [0.040] 25 [1.0] 1.5 [0.062] 90 5
90° unidirectional 25 [1.0] 250 [10.0] 2.5 [0.080] 25 [1.0] 1.5 [0.062] 90 5
Compressive Strength
Fiber Orientation Width, mm [in.] Overall Length, mm [in.] Thickness mm Gage Length mm [in.] Tab Length, mm [in.] Tab Thickness, mm [in.] Test Samples
0°, unidirectional 25 [1.0] 150 2.5 20 65 [2.5] 1.5 [0.06] 5
90°, unidirectional 25 [1.0] 150 2.5 20 65 [2.5] 1.5 [0.06] 5
Flexural Strength (Three-Point Bending)
Fiber Orientation Width, mm [in.] Overall Length, mm [in.] Thickness, mm [in.] Span Length, mm [in.] Span-to-Thickness ratio Test Samples
0° unidirectional 13 [0.5] 153.6 [6.14] 4.0 [0.16] 128 [5.12] 32 ; 1 5
90° unidirectional 13 [0.5] 153.6 [6.14] 4.0 [0.16] 128 [5.12] 32 ; 1 5
Shear Strength (Inter-Laminar)
Fiber Orientation Width, mm [in.] Length-L, mm [in.] Thickness, mm [in.] Test Samples
0° unidirectional 8 24 4 5
90° unidirectional 8 24 4 5
Shear Strength (In-Plane)
Stacking Sequence Width, mm [in.] Length mm [in.] Thickness mm [in.] Test Samples
[45/-45]n 25 250 2 5
Total Samples 45
Composite Laminate