IR Imager Changelog

----------------------------------

Version 3.21.3113.0
Fixed:
- Impeding false alarms at the end if initialisation phase.
- The false color images of snapshots (magnified) are taken after entering the
file name in the file dialog. This fixed and the false color image now is from the
same time es the radiometzric values.
- Updating the PIFTexts after changing the measuring mode (Min, Max,
Distribution...) to ensure the we have the correct unit (�C or %).
- Fixing problems with writing PIF-Configuration to autonomous devices.
- Fixing crashes when using the extended temperature range.

Version 3.20.3111.0
Fixed:
- Erroneous saving of the PIF-Type in the configuration dialog
- Crash with snapshot sequence (interval=0 -> fast as possible). The fix was to
ensure we don't start a new snapshot if the pending one is still not finished.
- Problem with wrong comparison in Autonomous.cpp when changing settings of Alarm
or Failsafe on PIFDO/AO. It could happen that the arrow of the send-to-device-
button remains red.
- Fixing the problem that AutoSkim was not executed with Ethernet-devices (e.g.
with TIM41).
- Correcting the display of the value next to measure area in case of mode "area
within limits".
- Preventing an exception that is raised if we access on PIFAI channels that we
recently deleted in the configuration dialog.
- Fixing problem when reading back the autonomous configuration simultaneously
with fast setting the PIFAO.
- Correct actualizing of the PIF-description in about box dialog after changing
the PIF-type in the configuration dialog.
- Problem with reading back autonomous configuration with a 1x1 pixel measure
area.
Added:
- Now there are two auto-modes for the temperature scaling of the temperature
profiles (same like in temperature time diagram they are called local and global).
- Staggering measure areas in single-line formats
- Displaying the Ethernet MAC address in the TCPIP settings dialog.
- Self updating the Software via FTP download.
- Supporting new Wiesemann & Theis USB-Server Gigabit with extended temperature
range. New TB number TB901160.
Changed:
- Updating Wiesemann & Theiss Software (USB Redirector, and WuTility)
- Now TIM M-1 is set to "Conditional AutoSkim" by default. So TIM M-1 behave like
the PI-imagers.
- Prevent start recording or snapshotting while direct temperature mode is
enabled.
- Now the combobox of the direct temperature mode is also visible if a format is
selcted that does not support this mode. But it is greyed out and a remark is
shown.
- The message "The port'COMx' does not exists" will only shown one time for the
not existing port. And if the port not exists the combobox for the comport in the
configuration dialog will be filled with the not existing port (and the remark that
it is not available).
- Calculating the average of a measure area on black-body-temperature-level. This
has also the consequence that we can present overlapping measure areas with
different emissivity's on the same pixels.
- The decision to decrease the minimum temperature scaling difference from 4K to
1K now only depends from the fact this temperature range is calibrated for high
temp resolution. Is does not depend from the setting in the configuration any
longer.

Version 3.19.3107.0
Fixed:
- Ensuring that after switching the PIF-Mode from Stackable to Intern the analog
PIF-Output-Mode is not set to 0..10V
(because internal PIF does not support voltage output).
- Ensuring a time delay of 500 ms after clicking the button "Set configuration to
device" (TIM41) between the set and subsequently reading of the
configuration. This is to prevent corrupted data if the reading is done to
quickly after writing the configuration.
- Setting of recording framerate had no effect in advanced recording mode.
- Comparison of TChip-mode and TChip-fixed-value for autonomous devices is not
needed as TIM41 and TIM8 don't have a chip heater.
- Fixing the problem that the firmware update only works if the new firmware is
on the first entry in firmware section of downloadlinks.xml
- Ensuring that after downloading a configuration from an autonomous device the
Radial Distortion Correction is disabled.
This is because the autonomous devices do not support radial distortion
correction and it would cause a warning message when opening configuration dialog.
- Suppress warning for "incompatible settings in autonomous devices" for all
devices that are non-autonomous.
- Wrong moving direction of the horizontal ruler while continuous line scanning
with presentation "left to right".
- Crash during screen capture if temporary filename is missing or corrupted.
- Fixing a crash occurring when an Ethernet device is physically disconnected and
no other Ethernet adaptors are available at the computer.
- Since fixing of Version 3.18.3103 the actualization of the hotspot coordinates
did not work any longer.
- Smartphones and PC browsers can stream now TIMConnect content whatever is
required. Connection was slowed down before.
- On replaying a ravi that was created by a merged line scan the coordinates of
the self-trigger-rectangle in the second view were
limited to a senseless range.
- Fixing a crash if polygone areas and hotspots are used simultaneously.
- Erroneous showing of the (!)-sign beside calculated line rate in line scanner
dialog.
- Making the advanced recording group invisible if the recording mode is not
Video Sequence.
- Play rate limit is sometimes set to 0.0.
- If an older normalization directory exists after actualizing the normalization
files this was not taken to the calibration directory.
- Problems with hot/coldspot temperature readings.
- Fixing problems with Flag forecast with TIM M-1 imagers.
- Ensuring that the software is not closed until flashing of configuration to the
device is ready.
- All decimal separators that are not a point were presented as a comma in CSV
files. On a de-DE-system a point was used a decimal separator if it was set
to "system". Both is fixed.
Added:
- Optional deleting measure areas after switching to a narrow format with 1M
imagers
- Optional possibility to widen presentation of narrow formats of 1M imagers
- Enabling and disabling termination resistor for TIM8/TIM41
- Improved ConnectSDK sample (C#) to demonstrate managing of maesure areas.
Changed:
- Extra window for flashing configuration to an autonomous device and for "line
scanner trigger extra time"
- Rejecting serial commands that are longer than 255 characters. (Responding with
"Unknown Command").
- Changed PIF-type-behavior. Until now the PIF-Type (internal, stackable ...) was
stored in the device (TIM8, TIM41) only.
Now the device is stored in the layout. For TIM8 it will be written to the
device immediately. For TIM41 it is written after using the write button
(this will work as of firmware 3818).
- New formats.def file (version 22) to support TIM41 MT.
- Removing RawToRavi-converter.
- Making "IR Image Only" as a possible mode of the WebServer more prominent.
- Using the decimal and value separator setting for the time/temperature diagram
too (same as for CSV snapshots).

Version 3.18.3103.0
Fixed:
- Software crashed occasionally while configuring a merger.
- The auto-start function of the webserver wasn't working with "IR Image Only" as
data source.
- Fixing Problem with finetuning the offset with merged line-scanning
- The Webserver will be disabled now in case if the user changes the IPCS Mode
while the Webserver is still running.
- Fixing a problem with the last entry in the temperature table.
- Advanced recording was not able to record TIM M-1 1000Hz
- Solving problems with snapshotting images with TIM M-1 imagers
- Fixing som rounding errors in linescanner configuration doalog
- Displaying the correct serial number on starting the software, if the camera
was changed meanwhile.
- Fixing problems with coordinates of measure areas after loading a merger
layout.
- Ensuring that in the eventgrabber-window on showing a snapshot the temperatures
under the mouse cursor will be shown.
- Problem with Reading a stored a (automatic) line scanner slit that was written
to a file before.
- Fixing a problem with starting FastCaptureRecording.
- Correcting image artefacts at top and bottom of the 125Hz format of TIM640.
- Fixing the problem that getting/setting the mask for a measure area from an
autonomous device results in senseless pixel information.
- ConnectSDK gets notified now in case recording is finished and the recorded
file was copied into its final destination.
- Software crashed when a TIM41 is used with a layout that contains polygone-
shaped measure areas.
- Correcting image artefacts at top and bottom of the 125Hz format of TIM640 if
radial distorsion correction is enabled.
- Preventing that the software get stuck if with an autonomous device polygone
measure areas and a hotspot is used in the same time. This prevents always
comparing the measure area matrices of polygones after every updating of the
hotspot location.
- "Avoid Flag while recording" is now also working for Advanced Recording.
- Crash while layout change.
Changed:
- TIM40 as of HW3401 is working with classical auto-skim algorithm
- If two decimal places are available for a temperature range it will also export
two decimal places to csv files.
- Webserver mode IR Imager only streaming capability added which also works, if
TIMConnect is minimized or hidden by other windows.
**********************
Version 3.17.3097.0
Fixed:
- The influence of the non-linear palette optimization was dependent from
enabling the extended temperature range.
- If in the IR arranging zoom and rotated was enabled, on starting up the
software the image remained black.
- A difference of failsafe configuration in software and TIM41 device was not
detected.
- Fixing a bug with the time stamps in event.log file.
- Wrong screen section if screen captured with "imager only" or "application" if
a scaled screen was used (other than 100%).
- Wrong screen section in webserver with "imager only" or "application" if a
scaled screen was used (other than 100%).
- Fixing a black screen if opening a snapshot with referencing enabled.
- The option in configuration dialog to set the video index used to make a
snapshot was not stored in the configuration.
- In snapshots from event grabbing the PIF values were not correct.
- Ravis recorded from a merged instance: PIF values were not correct.
- Advanced recording controlled by ConnectSDK - the software did not respond with
the path of the recorded file
- With ConnectSDK: Recording, stop recording and replaying caused a crash of
TIMConnect.
- Faulty recording of TIM M-1/05M/08M imagers.
- Fixing index problems when displaying the uncommitted value in connection with
calculated object in the second view
- Fixing a number of different memory leaks
- Fixing a crash behavior with capture screen function.
- Problem with slow baud rates: software did not recognize any command on some
computers (not on all).
- Loosing manual temperature scaling after switching the linescanner to sighting
view.
- ConnectSDK: Supplement 2x2 measure area shape to MeasureAreaShape enumeration
in ImagerIPC2.h to support shape 2x2.
- ConnectSDK: Fixing the crash issue after changing the shape of a measure area
from a single point to rectangle or ellipse by the SetMeasureArea command.
- Loosing the proper measure area size and position when switching a TIM VGA or
TIM M-1 to a clipped format.
Added:
- Writing "Dropped Frames" to Event protocol and Event log file.
- Focus adjustment per mouse wheel.
- Fast measure areas and alarms of measure areas on ConnectSDK.
- Fast response on PIF AO of the temperature reading of measure areas.
- Since rotated or zoomed IR arranging does not work in autonomous mode (of
TIM8/41), the software pops up a warning message if a user tries to set this up.
- New function GetRecordingStartTime in ConnectSDK
- Reporting function for serial communication.
Changed:
- Recording time limit is 10sec by default now (instead of 0).
- Default path for screen capturing changed to C:\Users\[user]\Documents\Imager
Data.
- Limiting the number of frames/flag-cycle to the device framerate. This is to
ensure the time of flag closed is not longer than 1sec.
- Implementing separate threads for snapshotting and updating snapshot history to
relieve the UI thread.
- Rearrangement of some elements on the measure area tab of the configuration
dialog (include/exclude hot/cold spots, hide measure area).

Version 3.16.3092.0
Fixed:
- Problem with dropping many UDP packets of the Ethernet connection.
- Fixing a crash when opening the Linescanner configuration dialog
(FormConfigLinescanner) if no imager is connected.
- The menu items for image subtraction didn't work.
- Fixing a problem with older TIM8-FW (older than 3021) presenting a black image.
- Firmware numbers 2600 and above did not support Industrial PIF.
- Fixing the flag-timeout problem after loading a layout with TIM41 at USB.
- Fixing a initialization problem after loading a layout with TIM QVGA, when a
initialization of the TIM40 is needed after that. Softawre hung with the green init
progressbar until the next flag cycle.
Added:
- New serial commands: ?TMA, ?TCO, ?MACount and ?COCount to support querying all
measure areas and calculated objects with a single command

Version 3.15.3090.0
Fixed:
- Mainform is started twice and loading the imager takes a long time at the
beginning if connected to a TIM41 via Ethernet.
- Wrong color of the alarm bars in digital display group if temperature reading
is exactlxy on the alarm threshold.
- Limit the slope scaling to 4mA (when used in 4..20mA mode) of a slope that is
read back from TIM8 and TIM41.
- Fixing an occasionally crash after disabling Ethernet in "Device menu".
- Preventing the download of calibration data from device or internet while
imager is in "direct temperature mode".
- Fixing problems with length of screen capture video (wmv)
- Problems when switching between imagers with and without enabled temperature
mode (TIM8 and TIM41)
- Occasionaly crash if enabling/disabling Ethernet devices
- Problems with reading the configuration out of a TIM8 device. The PIF
configuration get lost.
- ScreenCapture had accidently the ability to change registry key in
HKEY_CURRENT_USER\Control Panel\Desktop\WindowsMetrics\AppliedDPI without
permission (and developers awareness) and thus causing TIMConnect appearing with
mixed DPI settings.
- Problems with TIM200
Added:
- Option in configuration dialog to set the video index used to make a snapshot.
- Supporting the "Digitale PIF" mode.
Changed:
- Improving scale settings in adjust slope dialog.
- Preventing to set clipped format while image is zoomed or rotated.
- Disabling FW-Update via Ethernet.

Version 3.14.3087.0
Fixed:
- External triggering of event grabber via PIFAI was not working (in opposite to
PIFDI)
- Without any measure area configured the use of button "Hide this measure area"
or "include in" or "exclude in " caused a crash.
- Very old file (recorded with recording version 1) couldn't replayed because it
didn't set the NormtableIndex to 0 to enable the old temperature calculation. Also
the frame reducer didn't operate because there were no CounterHW values.
- Problems with auto-sync of external triggered line-scanning due to a change
3.12.3073.0 (Delay at Linescanner Triggering)
- Software hangs if there are corrupted snapshot files in the snapshot directory
- The layout mismatch dialog for the TIM8 appears again and again also if the
"never ask me again" button was enabled
- Workaround for users who use external controled flag with TIM40 (HW 3400).
- After changing the order of the measure areas (by "Up" and "Down" keys) or
after deleting a measure area the self-trigger area of the event grabber is not
still the same.
- Applying alternative emissivity for measure areas that are matrices (areas in
matrix shape that are read back from the TIM8).
- Problem that calculated objects didn't operate in the second view.
- Preventing checksum error for TIM8/TIM41: Checksum error for PIF's with an
EEPROM only.
- Preventing that on NTFS-formatted SD-Cards the software run into problems while
listing directories for the snapshot history. NTFS volume always have an protected
directory with the name "System Volume Information" that have no access.
- Fixing problems that occur when using multiple Ethernet devices on one
computer.
- Fixing the problem with applying the temperature range that was read back from
autonomous configuration.
- If a measure area that is routed to a certain PIFAO is removed this PIFAO
should not be assigned to another measure area.
- Problems with merging with multiple imagers
- Enabling TIM41 for extended layout setting

Added:
- Supporting TIM41
- Temperature mode for TIM8 and TIM41, inclusive demonstartion samples for
Ethernet and USB.
- Warning-message added for the case if the user choses Task planer and selects a
Duration > Repeat any - if this is the case the dialog can't be closed until the
mistake is corrected.
- Advanced recording with the ability to start a recording on time an also in the
past (pre-triggering).
- WebServer as an additional method of external communication
- New function "Super area" to combine existing multiple measure areas to a
single one.
- Implementing the ProgressBar for displaying the progress of flashing the
configuration especially after changing the temperature range (this takes nearly
20sec.).
- Listing the serial numbers and firmware revision numbers in the "About box".
- Question to upload the (changed and unsaved) configuration to the TIM41 device
when closing the software or switching to another imager.
- Buttons to start and stop all merged sub-instance with one click in merger
configuration

Changed:
- Redesign of help window (prompt /?)
- extension of Norm-1.prn up to 1825 C
- The deleting of the pixels on re-triggering a line-scan is optional now.
- Acceleration of opening the device menu by asynchronous seeking of Ethernet
devices
- Simplifying Ethernet-settings (it is all in one dialog now).
- Ensuring that alarm states are not changed/reset while starting and stopping
the software
- Ensuring that fail-safe edges come with an interval less than 200ms while
starting and stopping the software.
- Change of the algorithm to calculate the substitute pixels for the dead pixels.
- Change of glass-sheet-edge-detection: We detect the hot edges of glass-sheets
not only by the hot edge itself but by the cold background of the glass-sheet
- When we use a merged device the checkbox "Play after recording" is ignored.
- No splash-screen for merged instances.
- Configurable delay between start of merged instances and start of instances in
an separate thread.
- Reducing flag cycles for merged instances during initialization.
- Moving "Image Subtraction" from Device-menu to Tools/Extended.
- Moving Merging Setup from Tools/Extended to Tools and renaming all German terms
"Verbundger t" into "Merger".
- Change of default settings of the the tool bar.
- New release of formats.def to support TIM41.
- The ConnectSDK sample "Start IPC Extensive" supports starting of the TIMConnect
now.

Version 3.13.3080.0
Fixed:
- Ensuring correct order of triggered snapshots in snapshot history with
different prefixes like "Record" and "Record2" with respect to the following "_"
after the prefix.
- Better connecting a imager after switching from a merger layout to the standard
layout.
- Sometimes occurs a resetting of optics and temperature range to the first
available ones after loading a merger layout.
- Problems reading back polygone/spline measure areas from TIM8. Software
crashes.
- When the software starts with a ravi file as argument this causes the unability
to proceed as the question for loading the layout is overlayed by the splash
screen.
- Preventing to close sub-instances in merger operation if an opened viewer
instance is closed.
- Snapshot history was unable to search all subdirectories list the most recent
files.
- Software crash if ConnectSDK calls SetMeasureArea.
Added:
- Threshold for preventing new referencing for the external sensor in addition to
the threshold for the reference area.
Changed:
- Preventing the message "frame timeout" in status line while loading a merger
configuration.
- The configuration of the presentation of linescanning can no be done in this
modes: Length/Width and Linecount.
- In Options-Dialog: Moving the possibility to setup the behavior after
connecting a device into debug mode.
- When merging more than two devices only the first two serial numbers are shown
in the status line.

Version 3.12.3079.0
Fixed:
- When recording in LineScanner mode, don't reduce framerate
- When start Recording (TIM40) wrong temperature were shown at start
- On lower quality the size of measure areas in live image couldn't be changed
- In linescanner, changing the camera resolution cause bad format clip
- In Replay of LineScanner the measure areas are at the wrong place
- Changing PIF-AI Mode causes crash of TIMConnect
- Ensuring that the line scan auto snap shot is done with updated referencing and
the correct color palette.
- Problems with referencing if the reference measure area intersects with an
other measure area.
- Crash if the main area is a calculated and the alarm thresholds of this area
are bound to the measuring color threshold and thes are changed in the reference
bar.
- If we dont enable the high speed temperature calculation the peak/valley hold
time is shorter than enabled.
- Accidental drifting of the linescanner scan line in the linescanner view.
- Spot exclude/include areas could setup while paused play mode.
Added:
- Delay at Linescanner Triggering
- TIM41 Implemented in TIM40 Mode
- Linescanner prelines can be determint by given metric distance
- Explicitely scan length could overwrite the calculated scan length
- Changes in configuration dialog regarding spot exclusion areas
Changed:
- Double click on Snapshot History starts new instance
- Linescanner preline now don't have negativ values
- Redesign of referencing operation. It is now based on the radiation values
itself and should not be dependant from past calculation (this was unreliable with
strongly changing emissivities)
- Thresholds for self-triggered referencing based on Eps=1.0 (BB temperatures).
- Thresholds for preventing new referencing based on Eps=1.0 (BB temperatures).
- In hidden mode the short appearing of the main window is now prevented.

Version 3.12.3072.0
Fixed:
- If TIMConnect was used with TIM8 then it was nearly impossible to grab the
gripper symbols of the Measure areas - this is now fixed.
- Enabling and disabling of hot spot or cold spot in configuration dialog will
not auto-apply even if the auto-apply checkbox is marked.
- Hot and coldspots did not operate properly in the event grabber window.
- For replaying the button "selection only" did not operate without "infinity
play".
- Wrong behavior: If we turned the image by an user defined angle and we attained
the angle of 90 or -90 the image turned black.
- After loading a layout (or the standard layout) the motor focus position shown
in tool diastance was not the same as before. Mostly it was at the upper or lower
limit.
- If using triggered line scanning with pre-carriage lines the line scanner image
will not be erased with triggering a new line scan.
- Inconsistent results temperature time diagram while repeated replaying.
- Asking for the measure area settings (GetMeasureArea) with an index of an
calculated object via ConnectSDK causes TIMConnect to crash.
- Problems with synchronization of diagram resolution and framerate of the data
that will be written to the diagram.
Added:
- A visualizer was added to visualize Spot Include and Exclude Areas
- Possibility to hide and show any measure area individually.
- Saving of measure areas as csv file (instead of the whole image).
- ConnectSDK: Setting of fixed value of the reference temperature.
- Possibility to setup line scanning with keeping aspect ratio in infeed and
inline direction
- Keeping aspect ratio vor snapshot history.
Changed:
- The Measure Areas Objects can now also used as a Spotsearch- Include or Exclude
areas.
- Changing the list of auto-colors of the graphs in temperature time diagram.
- Updating the french translation.
- Changes on Tab "Snapshots/Copy to Clipboard": If resolution is "Genuine" the
label "Draw overlay information" is not visible any longer. (It was just disabled
until now).
- Removing GPS functioality.
Version 3.11.3070.0
Fixed:
- Peaks in temperature reading if device framerate is low (e.g. with USB server
connection)
Added:
- Ethernet reconnection after if the device is present again
Changed:
- After changing TCP/IP parameters of a TIM8 only if it is connected via Ethernet
the device will be disconnected

Version 3.10.3069.0
Fixed:
- Asking for the calculated object name via ConnectSDK does not work and causes
TIMConnect to crash.
- Emissivity was not applied when temperatures are referenced in offset mode
- Fixing problems with interfering of autoskim and flag forecast.
- Problems with showing TIFFs with referencing. Temperatures change when clickung
on the measure areas.
- An emissivity of a measure area while replaying is not applied in the first
replay. Starting with the second run it is applied.
- Prevent multiple rereferencing after a referenced line scan has finished.
Added:
- Signaling auto bias change on PIFAO/PIFDO
- Possibility to freeze frames after auto bias change
- Improvement of event planer with recording duration for each item
Changed:
- Reduce frequency of auto bias changes
- Since remote applications use the USB-Server (WuT), remote device aren't
supported by TIMConnect any longer.

Version 3.9.3064.0
Fixed:
- Colorpalette does change with toggling between linescanner view and linescanner
sighting view.
- Taking into account the offset and factor of internal sensors (TChip...) during
converting raw to ravi file.
- No uncommitted values could be displayed if we use calculated objects at the
same time.
- Functionallity with combination of replaying/referencing/linescanning was not
consistent.
- Software does not show a loaded snapshot if this is opened while no imager is
connected. On closing the software crashes.
- Fixing problems with replaying a RAVI file with temperature referenced
triggered line scanning.
Added:
- Referencing by external temperature probe connected by I C to PIF socket of the
imager. This function overlays PIFAI1 of a parallel connected PIF (via Y-adaptor).
- Radiation distorsion correction with a second coefficient.
- Firmware-Update: Forcing the user to disconnect all imagerrs except of the
imager thatt is to be updatet
- Scalebility of measure areas with polygone ans spline curve shape.
- Possibiltity to mark some measure areas (SHIFT key) and move and scale it
grouped.
- Reading back the autonomous configuration of TIM8 after displaying a selection
dialog after connecting the imager.
Changed:
- Increasing resolution of the the normalization tables (to have enough
resolution in first part of the table if temp-ranges are extended up to 1500 C).
- Moving the temperature range extension buttons in the "adjust slope dialog" to
the bottom of the slope diagram.

Version 3.8.3060.0
Fixed:
- Extended calibration (field calibration) didn't work while replaying a RAVI and
TIFF files.
- Crash after adding an auxiliary linescanner point after TIMConnect was started
first time.
- The layout files "Linescanner 4xx.xml" and "Linescanner self-triggered 4xx.xml"
were not listed with a TIM QVGA or TIM QVGAHD imager.
- After enabling the showing of reference temperature in digital display group
the value is 0.0 C until it is changed.
- Change Checkbox "High speed temperature calculation" to "Keep device framerate
for temp/time diagram, external communication and PIF outputs"
- Bug in creating the effective color palette in optimized mode (with non-linear
color table). It could happen that the last few entries are not created and used
from the last color table.
- Flickering in Linescanning (left-right-presentation) when buffered linescanning
is enabled.
Changed:
- Support of TIM160 (as of HW-Rev 22)
- Improving Consider-Flag-Functionality while referencing.
- Checkbox "Consider flag" on referencing tab in config dialog is removed. Flag
will always be considered.
- Improving referencing to support flawless referencing after flag cycle.
- Deactivation of palette optimization if extended measuring colors are used.

Version 3.8.3056.0
Fixed:
- Error message (Could not connect filter pins of "OF_ClC1" and "Grabber Test
IR1") when using line scanning and start-mode "minimized" or "invisible"
- Problems with invalid temperatures after multiple mouse moving in a complete
calculated linescanning image with referencing and visualisation of ignored pixels.
- Some language issues
Added:
- Loading califiles from TIM8 via Ethernet (supported with FW 3018).

Version 3.8.3055.0
Fixed:
- Only show internal Filtergraph menu item if in debug mode.
- Black screen after repeated layout load (especially with TIM8 connected by
Ethernet).
- Filenames of triggered recording were not listed in the list of most recently
used files.
- In merging operation the extended temperature range setting is now applied to
the sub instances to prevent temperature calculation problems if merger instance
and sub instance using different settings.
- If a recorded file or snapshot from a TIM450 in the lower temperature range
(20..100) is replayed and the high temperature resolution is disabled there are
non-sense temperatures.
- Fixing the problem that the drag and drop feature of the merger arranging was
crashing sometimes.
- Arbitrary jumping of temperature reading with referencing in the lower
temperature range (20..100). The threshold to start new referencing is reduced to
0.04K in this temperature range (0.2K for other ranges).
- Explicitly disconnect the ethernet device when TCP/IP settings are changed in
the connected device. Otherwise a WinSocket timeout error with a subsequent crash
is occurring on some systems now and then.
Added:
- Check if windows Permissions to access camera are granted and link to windows
settings if not
- The limits of the nominal temperature range (in status bar) are completed by
the limits calculated with the emissivity.
Changed:
- Default display reducing mode is now averaging.
- Updated DirectSDK sample.
- In merging operation the flag automatic of the subinstances is disabled now.
- Changing way to count the points on a user defined line-scanning line (for five
points from P1-P3-P4-P5-P2 to P1-P2-P3-P4-P5).

Version 3.8.3054.0
Fixed:
- Fixing a problem with autonomous mode (TIM8): using a device with zero measure
areas.
Added:
- Resetting Peak/Valley-Hold in autonomous mode of TIM8
Changed:
- Improving dialog for TCP/IP settings.

Version 3.8.3052.0
Fixed:
- Loosing PIFAO settings after changing a measure area via ConnectSDK.
- Fixing Problems with !AreaShap command in Serial Communikation
- Fixing a crash when a measure area is added (just for TIM8 in a special case)
Changed:
- Installation script is now made by Inno Setup 6.0.3 (WinXP is no longer
supported by Installer)
- Also the Win7 Installation is no based on .NET frame work 4.5 and Visual Studio
toolset v120 (redistributable files)

Version 3.7.3051.0
Fixed:
- The autonomous failsafe settings on PIFAO can be wrong (TIM8).
- On some computers the software crashes after switching to another layout with
the serial communication.
Changed:
- The default analog output mode for PIFs with mA-outputs is noe 0..20mA, instaed
of 4..20mA

Version 3.7.3050.0
Fixed:
- In a replayed RAVI file in line scanner mode there are no temperatures if the
end-of-file is ahaed of end-of-line-scan.
- When merging and line scanning is combined and the line scanner scanns on a
userdefined line - sometimes the software crashes.
- Problems with alarm output on PIFAO/PIFDO if multiple measure areas are used in
the second view of the event grabber.
Added:
- RawToRaw converter supports G7 imagers now.
Changed:
- If "extended temperature range" is enabled all temperature ranges go at least
up to 1500 C
- For G7 imagers the string "sighting view" for the lowest temperature range is
changed to "Low energy range".

Version 3.7.3049.0
Fixed:
- The directory to store RAVI and TIFF files was not stored in the layout, if the
layout was a payload of RAVI's and TIFF's.
- Needless flag time out after stopping an external triggered recording.
- Bad temperature accuracy in merging instance.
- Midformed notification window at start-up if PIF is configured but not present.
- Instable referencing if configuration is updated (OK-button in configuration
dialog).
- Reference value controlled by PIFAI is not applied at startup.
Changed:
- Normalization of temperature tables is done by loading tables from files now
- Saturated areas can be excluded from referencing (e.g. hot appearance of the
chamfered edges of low emissivity glas sheets)
- Configuration of referencing is on a separat tab in config dialog now.
- Improved line scanner averaging.

Version 3.7.3048.0
Fixed:
- The possibility to setup whether the focus motor position comes from the camera
or layout is now visible for TIM series only
Changed:
- Extending device name "TIM M-1/05M" to "TIM M-1/08M/05M" to support TIM08M
imagers.

Version 3.7.3047.0
Fixed:
- Wrong temperatures in extended temperature range (below 150 C)
- In snapshots the colore page is one frame back to the radiometric information.

Version 3.6.3046.0
Fixed:
- Prevent flickering of line scanner sighting view

Version 3.6.3045.0
Fixed:
- Fixing wrong temperature reading in temperatur ranges over 250 C
- Wrong times in temperature time diagram if the diagram is already while
overwriting.
- Prevent the serial communication to successfully return "!Layout=Name!" if
layout "Name" does not exists.
- Enabling the extended calibration files for the file import dialog to import
the cali files. And German translation.

Version 3.6.3044.0
Fixed:
- Finetuning when merging with linescanning didn work whe an object was close to
the overlap region
- A single measure area is sometimes not usable in the eventgrabber
- Occasionally crashing when setting the alarm of an uncommitted value to PIFAO2.

Version 3.6.3043.0
Fixed:
- The software does not find a way to download formats.def if corporate.xml is
not present too. Software hangs.
- Green initial progress bar after stopping a recording.
- Unnecessary flag operation after start and stop of recording.
- Uncommitted value does not work if event grabber is used.
- Crash if a measure area is moved to the second view if event grabber is not
enabled.
Added:
- Merging with line scanner mode: Dealing with offsets if two objects are not at
the same imager and not in the overlap region.

Version 3.6.3042.0
Fixed:
- Eventgrabber didn't trigger before OK-Button in configurations dialog was
pressed.
- Eventgrabber didn't work correctly with the PIF-Outputs
- Hint that the radial distortion coorection didnt work in TIM8 autonomous mode
also appeared when the PIF is not configured.
Added:
- Extended calibration available for users
Changed:
- Formats.def -> Version 13 to support 9Hz variant of TIM8

Version 3.6.3041.0
Fixed:
- When loading a layout in the software and never before an imager was connected
the temperature range is always set to -20..100 C (without respecting the
temperature range used by the layout).
- Problem with linescanning with odd height.
- Ensuring to start the program with the correct temperature scaling when used
in merging mode.
Added:
- Two radio buttons on tab device in configurations dialog: Either the focus
motor position comes from the device or from layout file.
- Added user defined decimal and value separator for CSV Export of snapshots.
- Image improvement for merged linescaning (averaging and after scan re-
adjustment of offsets of secondary imagers).
Changed:
- Changing the standard value for active PIFAO voltages is set to 1000 (10V or
20mA).
- Reducing of standard entries in CurrentL.xml.
- Reducing start time if many layouts have to be checked.

Version 3.6.3040.0
Fixed:
- Wrong resetting to temperature range 0 when e camera is connected after loading
a layout.
Added:
- Line averaging after a complete linescan
- Finetuning when merging with linescanning
- Memorizing focus motor position in the layout
- Flexible decimal separator

Version 3.6.3039.0
Fixed:
- Editing TCP/IP settings not possible (since 3038)
- Linescanner sighting view was not usable while replaying a ravi file.
- Line averaging with vertical presentation was not working.
- Ensuring that we display the emissivity we calculated by reference in the
status line after program start.
- When using the secondary view in triggered line scanning mode the 2nd view
remains black after starting the software until the line scan is triggered for the
first time.
- The Delta-Sign is still displayed if the image subtraction is used and we
switch back to standard layout.
- Fixing the problem if the software is in difference mode and the recording is
started the difference mode ends.
- Fixing the problem if the main measure area is a difference (calculated object)
and we display the main measure temperature in Fahrenheit - it is shown correctly
in the main window but the overlay of the snapshot shows a wrong Fahrenheit
temperature.
- Crash if a calculated area is the standard measuring object and we add a new
measure area. The solution is to increment the index of the standard measuring area
in this case.
Added:
- Disabling a new temperature referencing as long as the compared area is below a
certain temperature
Changed:
- Preventing trigering of a line scan as long as the green initialization bar is
visible

Version 3.6.3038.0
Fixed:
- "Mergerd Device" in status line instead of "unknown device" for merged devices.
- Considering calculated objects as differences in Fahrenheit (TT-Diagram and
analog outputs).
- Rounding problem with writing the longitude value into the EXIF data of the
TIFF-File.
- Fixing a crash after setting calculated area to Off or setting it to difference
with no operands.
- Wrong reseting of values in merger configurations dialog when using cancel
button.
- Improving inline averaging of line scanner.
- If in the merger configuration dialog a imager rectangle is moved by drag and
drop it happens that the application crashes.
- Fix of the problem that an alarm condition is not reseted if the high alarm
limit changes and falls below the current value (and vice versa for low alarm).
Added:
- MenuItem to store current layout in CurrentL.xml (Ctrl+S)
- Simultaneous presentation of life and linescanner video.
- Automatic slit detection and scan line for line scanning.
- Adjustment wizard for linescanner slit
Changed:
- Making windows for TCP/IP-settings more user friendly.

Version 3.5.3037.0
Fixed:
- Crash when using not existing PIF channel numbers with ConnectSDK

Version 3.5.3036.0
Fixed:
- Software could crash if the software tries to communicate with the imager while
a firmware update is in process.
- On computers with touch capabilities, the user was not able to setup the
computer in desktop user mode.

Version 3.5.3035.0
Added:
- Optionally the software can keep communication via Connect SDK, also if a new
loaded layout didn t use this.
- RawToRavi-converter for TIM M-1/TIM M-05 imagers
Fixed:
- Software could crash if a layout is saved via Connect SDK and afterwards
another layout is loaded via Connect SDK.
- Calculated areas with event grabber didn't work properly.
- Pink background in trimmed Ravi's
Changed:
- Removing the option to set the shape of a measure area to "Off"

Version 3.5.3034.0
Added:
- Averaging of a line scanner line
- Area calculating
Fixed:
- Line scanning with temperature referencing is now working with buffered line
scanning too

Version 3.5.3033.0
Added:
- Supporting new TIM 400 / TIM 450 camera
- Line scan status on PIF AO and PIF DO
- Dummy lines in triggered line scans as pre-carriage lines
- Message to inform the user that the radial distortion correction cannot be used
in combination with autonomous measuring areas (TIM8)
Fixed:
- Problem that user was not able to replay data from PIF AI2 if it was recorded
with TIM Connect Rel. 2.18.2239.0
- Invalid pixels were presented with a wrong color (e.g. pink) in snapshots.

Version 3.5.3032.0
Added:
- Ethernet settings and operation with different port numbers (UDP) for any
connected imager
Fixed:
- Problems with line scanning in combination of temperature referencing.
- Resolving inconsistency of line scanner items in main menu and toolbar.
- Wrong temperatures in snapshots with extended temperature range.
Changed:
- If a snapshot is open, no line scanner items are available in main menu and
toolbar any longer.
- Extension of the temperature table for values higher than 2248 C.

Version 3.4.3031.0
Added:
- Choosing temperature ranges by PIF input
Fixed:
- Accidentally flag-timeout when using PIF

Version 3.4.3030.0
Added:
- In merging, the frame sync was working with rising edge signals only. It is now
configurable with rising, falling or both edges.
- Mirroring within line scanner line.
- Output of recording status on PIF AO and PIF DO
- Possibility to disable saving of triggered video recordings.
Fixed:
- Alignment of some elements on the Measuring colors tab in the configuration
dialog was wrong.
- Fixing the problem that after a time-limited recording a triggered recording
was not possible any longer.
- Some issues in configurations dialog in touch / tablet mode
Changed:
- The order of the firmware updates is changed (FPGA first).
- Allowing to interrupt a triggered recording by the recording time limit. -
Version 3.3.3029.0
Added:
- Avoid correcting based on internal temperature sensors while triggered line
scanning. This is to prevent spontaneous temperature jumps during scan.
Fixed:
- For some TIM40 the initial auto skim didn't operate properly (resulting in an
image out of scale)
- The image remained black after changing the IR arranging and auto skim was
active already.
- In Configuration/Measure Areas: Prevent selecting the separator (of measure
areas and calculated areas) after deleting the last measure area.
- Some functions (Configuration, Snapshot, Recording, ) were not available in
merging mode - since 3.3.3028.0.
Changed:
- Limit of the maximum recording duration in the alarm configuration was changed
to 86400.

Version 3.3.3028.0
Fixed:
- Crash on some merger-layouts as of version 3.3.3027.0
- Flag is triggered more often as setup in the configuration.
- Making a new snapshot from an opened snapshot cases a access denied exeption if
the same file name is used.
- In Tool "Distance" when used vertically for the focus motor position the null
and the infinite character are mixed up
Changed:
- Again improving TIM40-specific Auto skim support. The intermediate storing of
the skim values in a file isn't needed any longer.

Version 3.3.3027.0
Added:
- 0-20mA Output for internal PIF of TIM8
Fixed:
- The emissivity value that is stored with a TIFF snapshot was not used properly.
Changed:
- Emissivity setup down to 0.01.
- Improving TIM40-specific Auto skim support. Values that are used allready are
stored in a file and reused.

Version 3.3.3026.0
Changed:
- TIM40-specific Auto skim support.

Version 3.3.3025.0
Added:
- The ConnectSDK receives an event if a file command (play, pause or stop) was
executed.
- The difference value for calculating TAmbient from TBox is now defined device-
specific.
Fixed:
- Pause function in linescanner mode was not working properly.
- Presenting temperature profiles in event grabber mode. The profiles were not
shown before configuration dialog was reopened.
- Sometimes the application was crashed if the replay of a video was stopped and
no imager was connected.
- Sometimes the application was crashed when connected to a netbox (as a network
device).
- Problem with converting raw files.
- The resolution of the time temperature diagram could not be reduced while
replaying a ravi file.
- Problem with the emissivity adjustment in TIM8 (autonomous mode).
- After a snapshot the access to the file was blocked for a too long time.
- The position of the linescanner line was moved after activating and
deactivating the linescanner mode.
- In linescanner mode the data and time information could not be displayed over
the video.
Changed:
- If the flag is closed the snapshot will be done with the first frame after the
flag is open.
- Deactivation of the elements "optics", "temperature range" and "framerate" in
the status line if we are in a merged instance and the master source instance is
replaying a file.
- Improving autoskim functionality.

Version 3.2.3024.0
Added:
- Optional forcing a flag cycle after initialization of camera or changing
temperature range or video format (also if flag is controlled externally).
Fixed:
- Sometimes the software crashes if started with a layout that uses event
grabber.
- Deleting the history in temperatur time diagram while replaying a ravi file if
the user uses one of the range mode buttons (Manual, Min/Max, 1sigma, 3sigma or
Opt)

Version 3.2.3023.0
Added:
- Autonomous flag automatic configuration for TIM8
- Autonomous use of emissivity and ambient temperature for TIM8.
Fixed:
- Software freezed if application is setup as "always on top" and the user is
going to setup the "alarm to PIF" configuration.
- Setting of alarm threshold via Connect SDK was not possible.
- A measure area could be moved one pixel outside the IR image. Afterwards it was
not clickable any longer.
- Eventgrabber: After enabling temperature profiles in the menu it will appear
not before configuration dialog was opened.

Version 3.2.3022.0
Added:
- Japanease language.
Fixed:
- Uncommited value was not taken into account when replaying a ravi.
- Selftriggering in Fahrenheit was buggy.
- During installation: Multiple hint that a virus scanner is active.
- Wrong declaration of file managment function in DirectSDK (IPC2.h and IPC2.cs)
- Ethernet connected device: Error on re-selecting the same device.
- Ethernet connected device: Initializational progrssbar with same speed as with
USB connected devices.
- Global scaling of temperature-time-diagram: Proper memorizing values until next
software start.
- Adjust PIF-slope dialog: Exception when emissivity or uncommited value is used
as analog input.
- Inproper scaling of extended palette in measuring colors setting.
- Time stamp of temperature-time-diagram does not match stored values in ravi.
- No automatical connection after launching software if imager was changed.
- Some sample programs of the ConnectSDK didnt work.
- Crash after setting Ethernet activation checkbox in options dialog (if the
Ethernet device is connected).
Changed:
- Focusmotor setting just with setting point value, and 100% = infinite symbol.
- More flexibility in product branding for private labels.
- Peak- und valley-hold: hold time of 999s means infinity hold time.

Version 3.2.3020.0
Added:
- Support of Ethernet functionality of TIM8 devices
Fixed:
- In merging mode the source instances will not close on closing the merger
instance
- Setting up a display rate of 10Hz this can cause a crash on next software start

Version 3.1.3015.0
Fixed:
- screen capture (wmv) scaling issue
- issue with inverting signal on PIFAI1 (depending from the function of PIFAI2)
Changed:
- improving support for industrial PIF with current output(mA)

Version 3.1.3014.0
Fixed:
- no temperature information at mouse cursor position in event grabber window
- extended measuring colors differs for live view and event grabber view
Changed:
- change of classification for event "flag to short" from critical to warning

Version 3.1.3013.0
Added:
- setting of alarm threshold for single measuring areas via ConnectSDK
- Set standard layout via video context menu
Canged:
- set temperature display range for event grabber frame and main frame
simultaneously
- increasing maxium number of imagers to 32 for merging application
- optimized emissivity setting for live display and video replay
Fixed:
- switch of previous TIM400 light weight is not working
- hotspot metadata in frames via ConnectSDK is missing
- empty snapshot after stopping record
- incorrect temperature range for manual display range in merger instance

Version 3.1.3012.0
Added:
- support for industrial PIF with current output(mA)
- 4-20 mA operation mode for current output
Fixed:
- frames are not display in event grabber window for radiometric videos

Version 3.1.3011.0
Added:
- Support for new TIM product line
- Support for new TIM product line in ConnectSDK
- Motor focus control for TIM product line
- Completing russian language files
- Introduction of new Metadata frame structure in
Connect SDK
- Scaling of measure area label size
- Display device type of camera in device context
menu
- Tool control for displaying PIF input state
- Detection of cable break for new stackable PIF
- Switch temperature units via context menu
- Display of date and time in snapshot history
- Controlling TIM's focus motor via ConnectSDK and
serial interface
- Save current layout with name via ConnectSDK
- Create snapshots with event grabber
- Measuring in grabbed frames
- fixed measure area size (2x2 pixel)
Changed:
- Renaming of the software
- Redesign of PIF-configuration
- Redesign of Eventgrabber
- File filter for all radiometric file formats when
opening a file
- List all merged devices in event protocol
- Redesign context menu for loading calibration data
Fixed:
- Distribution mode's range for measure areas cannot
be set via ConnectSDK
- Issue with selecting trigger area for line scanner
- Software hangs after screen capture
- Cannot save video after trimming
- When replaying Ravi-Video a second time, the Temp-
Time-diagram is not updated
- Image artefacts when using extended colors
- Performance and display issues with for continuous
line scanner mode with TIM VGA@125Hz
- Issue with displaying value of measure area in
temperature time diagram
- Cannot record during line scan
- Effective start of external communication only after
software restart
- Issue with callbacks in ConnectSDK if connection
timeout and restart happens
- Start time of exported temperatures are temporal not
synchronous with temperature time diagram