ITM509
ITM509
Qualitrol Contact Information: [email protected] (USA) 585-586-1515, option “1” Fax: 585-377-0220
* L & M are for self-powered transducers, N & O are for unpowered transducers.
INPUT 9 X
INPUT 10 X
INPUT 11 X
INPUT 12 X
INPUT 13 X
INPUT 14 X
INPUT 15 X
INPUT 16 X
Please mark ALL boxes.
Choose X for Empty slots. Can be changed in
Please show amps after configuration
C_ or I_, e.g. C10 for 10 software
amp CT.
0 to 125 VDC
0 to 48 VDC
+/- 5 VDC
0 to 1 VDC
OR
0 to 1mA DC
Current Output
(Requires a “Third Party” Device that
generates a current output proportional
4 to 20mA DC
to Tap Position)
FRONT PANEL LAYOUT SECTION
PHASE A
PHASE B
PHASE C
SPARE
SPARE
SPARE
SPARE
SPARE
* The first 16 fiber inputs are digitally connected to the 509. If more than 16 inputs are needed, please contact your Applications Engineer.
** Optical Feed Through connectors (CON-659-1) are available separately as well.
COMMUNICATIONS SECTION
(Multimode Transducer)
(Purchase of FX includes TX)
Required for IEC 61850
Fiber Optic Ethernet FX, SC Connection;1300 nm
(Single mode Transducer- Only 1 FX module may be
installed)
(Purchase of FX includes TX)
*Only one Ethernet(Copper or Fiber optic) port can be active at one time – either TX or FX.
NERC-CIP COMPLIANCE MODULE(* REQUIRES ETHERNET)
Below table lists the NERC-CIP sections and their description that our ITM509 monitor will be compliant with if the above module is purchased.
SECTION DESCRIPTION
TransLife™ Includes automatic Consumed Life, Critical Forecast, and Temperature Profiler functions
(Included)
Low Temperature Lockout – minimizes static electrification and arcing by ensuring pumps remain off (ambient
sensor sold separately) (Included)
Pre-cooling – limits damaging high temperatures produced by overloads by initiating cooling early
Advanced Cooling (Included)
Control Seasonal Setback – customize cooling schemes based on the time of the year (ambient sensor sold
separately)
Adaptive Ambient Control – adaptive cooling based on ambient temperature forecast (ambient sensor sold
separately)
Logs up to 20 parameters with a selectable sample rate and 256 Mb of non-volatile internal memory
Data Logging
(e.g., 14 parameters, sampled and stored once a minute, will be logged for 90 days before being overwritten.)
Event Recording Records time and date or a complete system snap shot, capable of storing over 60,000 events
All the following software options are field configurable and are not
required to create a model number.
Default options shown will be preselected.
Yes
Hard Copy of Instruction Manual (All units come standard with an electronic copy)
Quantity
100 Ω 103-023-01
Traditional RTD Sensor Standard RTD Well Mount 7/8 - 14 thread, 513/16 Feet
inch length Meters
10 Ω 103-022-01
Gas DGA-150-G-1 ea
Single Gas Hydrogen Sensor Drain valve mount, 1 ½” NPT thread union fitting – THREAD MOUNT
Oil DGA-150-L-1 ea
Gas DGA-250-G-1 ea
Single Gas Hydrogen Sensor, with Pressure Sensor, 2 ½” NPT thread union fitting – THREAD MOUNT
Oil DGA-250-L-1 ea
Gas DGA-400-G-1 ea
Single Gas Hydrogen Sensor, with Pressure Sensor – FLANGE MOUNT
Oil DGA-400-L-1 ea
Hydrogen Sensor Universal Power Supply – 24VDC – 1 per DGA sensor required PWR-025-1 ea
RS232 Cable, 6 ft. (CAB-044-1 will appear as separate line item) Yes?
RS232 Cable, 10 ft. (CAB-044-2 will appear as separate line item) Yes?
USB to DB-9, 1 ft. (CAB-049-1 will appear as separate line item) Yes?
USB-A TO USB-B, 6 ft. (CAB-050-1 will appear as separate line item) Yes?
Select the following properties for each relay: RELAY 1 RELAY 2 RELAY 3 RELAY 4 RELAY 5 RELAY 6 RELAY 7 RELAY 8
SETTINGS Input 1
Input or Relay # Input or Relay # Input or Relay # OR Input or Relay #
OR
Set Point 50 OR
Relay 1
SETTINGS Input 1
Input or Relay # Input or Relay # Input or Relay # OR Input or Relay #
OR
Set Point 60 OR
Relay 2
SETTINGS Input 1
Input or Relay # Input or Relay # Input or Relay # OR Input or Relay #
OR
Set Point 70 OR
Relay 3
SETTINGS Input 1
Input or Relay # Input or Relay # Input or Relay # OR Input or Relay #
OR
Set Point 80 OR
Relay 4
SETTINGS Input 1
Input or Relay # Input or Relay # Input or Relay # OR Input or Relay #
OR
Set Point 100 OR
Relay 6
SETTINGS Input 1
Input or Relay # Input or Relay # Input or Relay # OR Input or Relay #
OR
Set Point 110 OR
Relay 7
SETTINGS Input 1
Input or Relay # Input or Relay # Input or Relay # OR Input or Relay #
OR
Set Point 120 OR
Relay 8
#1 Custom Range
Maximum
Input #
MINUS
Yes No
Minimum Input # Input #
Enabled Yes No st
1 Input # nd
2 Input # rd
3 Input #
0 — 1 mA
Current Loop Type 4 — 20 mA
Loop Output Other 1
OR OR
#2 Custom Range
Maximum
Input #
MINUS
Yes No
Minimum Input # Input #
Enabled Yes No st
1 Input # nd
2 Input # rd
3 Input #
0 — 1 mA
Current Loop Type 4 — 20 mA
Loop Output Other 1
OR OR
#3 Custom Range
Maximum
Input #
MINUS
Yes No
Minimum Input # Input #
Enabled Yes No st
1 Input # nd
2 Input # rd
3 Input #
Current 0 — 1 mA
Loop Type 4 — 20 mA
Loop Output Other 1
OR OR
#4 Custom Range
Maximum
Input #
MINUS
Yes No Minimum Input # Input #