Product description
The type U1000 V2 is an ultrasonic permanent Clamp-On flowmeter. This cost effective device
can either be used as a stand-alone meter or as an integral part of a control loop.
The type U1000 V2 is very simple to install – clamp it on to the pipe, connect it to power and
enter the pipe diameter. No expertise or special tools are required.
The "Clamp-On" concept allows for easy installations without process disruption. Compact,
robust and reliable – the type U1000 V2 was designed for long-term use in industrial
applications.
The type U1000 V2 is especially configured for pure water and can be used on PVDF, ABS,
PVC, CPVC, PP, PE, PB-Instaflex, iron and steel pipes. Processes can be monitored directly by
a higher-level system via 4 to 20 mA, Modbus, pulse or frequency output.
Benefits/features
• Large, easy to read graphic display with backlighting
• Easy to install without special tools FM
• „Clamp-on“ design APPROVED
Applications
• Ultrapure water measurement
• Chilled water metering
• Flow measurement for energy metering
• Monitoring of manufacturing processes
• New Water / Glycol Measurement
Technical data
Specifications
General
Measuring method Ultrasonic transit-time measurement
Flow range 0.1 m/s – 10 m/s (0.3 ft/s - 32 ft/s)
Accuracy ± 3 % of the flow value with a flow rate > 0.3 m/s
Repeatability ± 0.5 % of the measured value
Response time < 500 ms
Selectable flow units Velocity m/sec, ft/sec.
Volume l/s, l/min, gal/s, gal/min, USgal/s,
USgal/min, m3/min, m3/hr
Selectable totalizer units Liter, m3, gals, USgals
Menu languages EN
Environment
Maximum Pipe temperature 0 °C to +85 °C 32 °F to 185 °F
Operating temperature 0 °C to +50 °C 32 °F to 122 °F
Storage temperature -10 °C to +60 °C 14 °F to 140 °F
Temperature of pipe wall 0 °C to +85 °C 32 °F to 185 °F
Humidity during operation Max. 90 % relative humidity at +50 °C (122 °F)
Maximum altitude 4,000 m
Indoors/outdoors Indoors
Wet locations A location in which water or other liquid can drip, splash, or
flow on or against electrical equipment.
Pollution degree 3: Conductive pollution or dry nonconductive pollution that
becomes conductive due to condensation.
Suitable pipe types
Pipe materials PVDF, PP-H, PE, PB, ABS, PVC, CPVC, steel, iron, stainless
steel 316
Pipe diameter (OD) 22 - 180 mm* 3/4 - 7 inch*
Electronics
Power supply 12 - 24 V AC/DC
Power consumption Max. 7 VA
Outputs
Analog output
Range 4 - 20mA
Resolution 0.1 % of measurement range
Load max. 620 Ω
Insulation 1MΩ at 100 V
Alarm current 3.5 mA
Pulse output
Type Opto-Isolated MOSFET volt free contact (NO/NC)
Pulse sequence 1 – 166 pps user-programmable frequency mode max. 200 Hz
Pulse width 50 ms standard value, 3 – 99 ms user-programmable
Max. voltage 24V DC or 24V AC
Max. current 500 mA
Insulation 1MΩ at 100V
Modbus
Format RTU
Baud Rate 1200, 2400, 4800, 9600, 19200, 38400
Data-Parity-StopBits 8-None-2, 8-None-1, 8-Odd-2, 8-Even-1
Standards PI–MBUS–300 Rev. J
Physical connection RS485
Shipping information
Packet dimensions 290 x 280 x 100 mm 11.4 x 11 x 4 Inch
Weight 1.4 kg 3 lbs
Volume weight 1.4 kg 3 lbs
Standards/approvals
CE, UKCA, RoHS compliant
UL listed
Security BS EN 61010-1:2010
EMV BS EN 61326-1:2013 BS EN 61326-2-3:2013
Environment BS EN 60068-1:2014
BS EN 60068-2-1:2007 BS EN 60068-2-2:2007
* Note: Pipe size is dependant on pipe material and inner pipe diameter
Default Values
Parameters Metric Imperial
Dimensions mm Inches
Flow Units l/min USgal/min
Pipe size (ID) 1" to 4" pipes: 50 mm 1" to 4" pipes: 1.969 in
4" to 6" pipes: 127 mm 4" to 6" pipes: 5.000 in
Pulse Output Off Off
Volume per Pulse 10 litres 2.642 US gallons
Pulse Width 50 ms 50 ms
Damping 20 seconds 20 seconds
Calibration Factor 1.000 1.000
Zero Cut-off 0.02 m/s 0.07 ft/s
Zero Offset 0.000 m/s 0.000 ft/s
Dimensions
U1000 dimensions:
B B
46.8 mm (1.84 in.)
78.4
47.0
A
SECTION A-A
208.4 mm (8.20 in.)
Packaging content
1 Guide rail
1 2 Type U1000 V2 head-unit
incl. cable (5 m length)
6 3 Gel pads
4 Pipe adapters
5 S/steel hose-clips for guide
2 rail
5 6 Modbus cable (Modbus
models only)
7 Product documentation(-
Quick-start guide & factory
assembly certificate)
Function
The U1000 V2 functions, as do all GF current ultrasonic flow meters, according to the transit
time principle of ultrasonic waves.
Flow pipe
°C
Flow Sensor Temp. Sensor
Temp. Sensor
Return pipe
°C
The type U1000 V2 functions, as do all current ultrasonic flowmeters, according to the
path-time principle of ultrasonic waves.
The device is installed directly on a pipe surface and transmits ultrasonic waves back and
forth between the two sound transducers. Depending on the flow, a small time difference
arises between the two ultrasonic signals – this is proportional to the flow speed.
Ordering Information
Code Type Description
159 300 300 U1000 V2 Type U1000 V2 | Flowmeter | 12-24 VAC | d22-d115 | 0.75 in. to 4 in. | 4 to 20 mA, Pulse
159 300 301 U1000 V2 Type U1000 V2 | Flowmeter | 12-24 VAC | d125-d180 | 5 in. to 6 in. | 4 to 20 mA, Pulse
159 300 302 U1000 V2 Type U1000 V2 | Flowmeter | 12-24 VAC | d22-d115 | 0.75 in. to 4 in. | Modbus, Pulse
159 300 303 U1000 V2 Type U1000 V2 | Flowmeter | 12-24 VAC | d125-d180 | 5 in. to 6 in. | Modbus, Pulse
The information and technical data (altogether “Data”) herein are not binding, unless explicitly confirmed in writing. The Data
neither constitutes any expressed, implied or warranted characteristics, nor guaranteed properties or a guaranteed durability. All
Data is subject to modification. The General Terms and Conditions of Sale of Georg Fischer Piping Systems apply.
06/2024-A
© Georg Fischer Piping Systems Ltd, 8201 Schaffhausen/Switzerland
Tel. +41 52 631 11 11 • www.gfps.com • E-Mail: [email protected]