SIETH

Driver Guide

Version: 10.15
SIETH Driver Guide

Contents

Introduction .................................................................................................................. 5
General Information ..................................................................................................... 7
Device Characteristics ........................................................................................................................7
Link Characteristics .............................................................................................................................7
Driver Characteristics ..........................................................................................................................7
Conformance Testing ..........................................................................................................................8
Special Device Configurations ............................................................................................................8
Installing the Driver .................................................................................................... 13
Configuring the Driver ................................................................................................ 15
Setting the Communication Parameters ...........................................................................................15
Configuring the Driver Worksheet .....................................................................................................17
Main Driver Sheet (MDS) ..................................................................................................................24
Executing the Driver ................................................................................................... 27
Troubleshooting ......................................................................................................... 29
Revision History ......................................................................................................... 33

Version: 10.15 3
SIETH Driver Guide

C HAPTER 1
Introduction
SIETH Communication Driver - Driver for Ethernet Communication
Between Studio and Siemens DevicesThe SIETH driver enables communication between Studio system
and the Siemens devices using Ethernet, according to the specifications discussed in this publication.
This publication was designed to help you install, configure, and execute the SIETH driver to enable
communication with the Siemens devices. The information in this publication is organized as follows:
 Introduction: Provides an overview of the SIETH driver documentation.
 General Information: Provides information needed to identify all the required components
(hardware and software) used to implement communication between Studio and the SIETH driver.
 Installing the Driver: Explains how to install the SIETH driver.
 Configuring the Driver: Explains how to configure the communication driver.
 Executing the Driver: Explains how to execute the driver to verify that you installed and configured
the
driver correctly.
 Troubleshooting: Lists the most common error codes for this protocol.
 Sample Application: Explains how to use a sample application to test the driver configuration.
 Revision History: Provides a log of all modifications made to the driver and the documentation.

Note: This document assumes that you have read the "Development Environment" chapter in the
product’s Technical Reference Manual. This document also assumes that you are familiar with the
Windows XP/7/8 environment. If you are unfamiliar with Windows XP/7/8, we suggest using the Help
feature (available from the Windows desktop Start menu) as you work through this guide.

Version: 10.15 5
SIETH Driver Guide

C HAPTER 2
General Information
This chapter explains how to identify all the hardware and software components used to implement
communication between the SIETH driver and Siemens devices.
The information is organized into the following sections:
 Device Characteristics
 Link Characteristics
 Driver Characteristics
 Conformance Testing

Device Characteristics
This driver has been tested successfully with the following devices:
 Manufacturer: Siemens
 Compatible Equipment: Any Siemens S7-200, Siemens S7-300/400 PLC communicating via an
Industrial Ethernet interface, S7-1200, S7-1500, and LOGO! in S7-200 mode
 Siemens PLC Programmer Software: Step-7, Step7-MicroWin, TIA Portal

Link Characteristics
To establish communication, you must use links with the following specifications:
 Device Communication Port: Ethernet Port
 Physical Protocol: TCP/IP
 Logic Protocol: S7 Messaging on Industrial Ethernet
 Adapters/Converters: Standard Ethernet card

Driver Characteristics
The SIETH driver is composed of the following files:
 SIETH.INI: Internal driver file. You must not modify this file.
 SIETH.MSG: Internal driver file containing error messages for each error code.
You must not modify this file.
 SIETH.PDF: Document providing detailed information about the SIETH driver.
 SIETH.DLL: Compiled driver.

Note: All of the preceding files are installed in the /DRV subdirectory of the Studio installation directory.
The SIETH driver requires the AGLINK.DLL into the /BIN.
You can use the SIETH driver on the following operating systems:
 Windows XP/7/8 and Servers 2003/2008/2012
 Windows CE

Version: 10.15 7
SIETH Driver Guide General Information

The SIETH driver supports the following registers:

Register Type Write Read Bit Byte Word DWord Float String

M (Flags) · · · · · · · ·
SM (Special Flags) · · · · · · · ·
T (Timers) · · - - · - - ·
Z or C (Counters) · · - - · - - ·
E or I (Inputs) - · · · · · · ·
A or Q (Outputs) · · · · · · · ·
DB or V (Data · · · · · · · ·
Blocks)

Note: The V Register from S7-200 devices can be accessed with the DB1 Register

Conformance Testing
The following hardware/software was used for conformance testing:
Driver Configuration:
 PLC Program: Step 7
 Protocol: S7 Messaging on Industrial Ethernet

Driver Studio
Operating System Equipment
Version Version

 S7-315 2DP with CP343


 Windows XP/7/8
Studio v.  S7-215 with CP-243
10.15  Windows CE 5.0 (x86)
20.0.2  S7-1500 (CPU 1511-1 PN).
and 7.0 (ARMV4I)
 S7-400 (CPU 412-2)

Special Device Configurations


S7-1200 / S7-1500
For the PLCs of these families, you have to enable the communication to remote devices on the
SIEMENS TIA-Portal software.
Please follow the steps below to permit access communication from remote partners:
1. After adding the proper CPU to the PLC program, go to the device properties (e.g. right click on the
CPU name and pick Properties);
2. Under General tab select Protection at the menu list on the right side;
3. Under Protection make sure you have the access level "Full access (no protection)" selected;

8 Version: 10.15
General Information SIETH Driver Guide

4. At the bottom of this screen, under "Connection mechanisms" enable the option (CHECK the box)
"Permit access with PUT/GET communication from remote partner (PLC, HMI, OPC, …)". See
screenshot below;

5. Confirm with OK;


6. Recompile and send the program to the PLC.

Data Blocks configuration


The Data Blocks (DB’s) on SIMATIC TIA Portal V12 are created by default with the option "Optimized
block access" enabled. This option provides data only over the variable names (Tags names). Since the
InduSoft drivers access the memory offsets, this options must be manually disabled.

Execute the following steps to do so:


1. Go to the Data Block properties dialog (e.g. right click on the desired DB and pick Properties);

Version: 10.15 9
SIETH Driver Guide General Information

2. On menu Attributes disable the option (UNCHECK the box) "Optimized block access". See
screenshot below.

3. Confirm with OK.

10 Version: 10.15
General Information SIETH Driver Guide

Opening the Data Block view, the additional column "Offset" must be shown on the table which brings the
memory offsets to be used on the InduSoft drivers such as the SIETH.

Note: For arrays, the main offset must be added with the element offset – e.g. DB1.DBB6 (Byte 6) refers
to the array element Static_3[2], DB1.DBB14 (byte 14) refers to the array element Static_3[10] on the
Data Block shown above.LOGO! (Acting as S7-200)

When you have a LOGO! CPU with Ethernet, such as the Logo!12/24 RCE and Logo!230 RCE, you can
configure its communication to act as a S7-200 PLC.
The screenshot below shows where to configure the TSAP on the LOGO! Software. Also, be sure to
check the indicated boxes.

Version: 10.15 11
SIETH Driver Guide General Information

Note: Please refer to the Communication Settings and the Station fields on the Driver Sheets on how to
properly configure the TSAP parameters.

12 Version: 10.15
SIETH Driver Guide

C HAPTER 3
Installing the Driver
When you install Studio version 5.1 or higher, all of the communication drivers are installed
automatically.
You must select the driver that is appropriate for the application you are using.
Perform the following steps to select the driver from within the application:
1. Open Studio from the Start menu.
2. From the Studio main menu bar, select File →Open Project to open your application.
3. Select Insert →Driver from the main menu bar to open the Communication Drivers dialog.
4. Select the SIETH driver from the Available Drivers list, and then click the Select button:

5. When the SIETH driver displays in the Selected Drivers list, click the OK button to close the dialog.

Attention: For safety reasons, you must be careful when installing the physical hardware. Consult the
hardware manufacturer’s documentation for specific installation instructions.

Version: 10.15 13
SIETH Driver Guide

C HAPTER 4
Configuring the Driver
After opening Studio and selecting the SIETH driver, you must configure the driver. Configuring the
SIETH driver is done in two parts:
 Specifying communication parameters
 Defining communication tags and controls in the Communication tables or Driver worksheet
Worksheets are divided into two sections, a Header and a Body. The fields contained in these two
sections are standard for all communications drivers — except the Station, Header and Address fields,
which are driver-specific. This document explains how to configure the Station, Header and Address
fields only.
Notes: For a detailed description of the Studio Standard and MAIN Driver Worksheets, and information
about configuring the standard fields, review the product’s Technical Reference Manual.

Setting the Communication Parameters


Use the following steps to configure the communication parameters, which are valid for all driver
worksheets configured in the system:
1. From the Studio development environment, select the Comm tab located below the Workspace.
2. Click on the Drivers folder in the Workspace to expand the folder.
3. Right-click on the SIETH subfolder, and when the pop-up menu displays, select the Settings option:

Version: 10.15 15
SIETH Driver Guide Configuring the Driver

The SIETH: Communication Parameters dialog displays:

This driver does not have custom parameters. Specify the parameters as noted in the following table.
Parameters Default Valid Description
Values Values
1-Signed This value will be default if you do not specify the
0-Unsigned 0 0 or 1 Unsigned/Signed parameter for each format
Value address.
For S7-200 communication (as well as LOGO!), configure the Remote TSAP in the Station field in
the advanced settings. If Station field is left empty, the default Remote TSAP of 0x4D57 is used. In
the Station of Protocol, we can configure the Remote TSAP value.

16 Version: 10.15
Configuring the Driver SIETH Driver Guide

Notes:
The Remote and Local TSAP are configured in S7-200 using Micro/WIN’s Ethernet Wizard. In that
wizard, TSAP’s are configured in the format XX.YY. In SIETH driver, write these values as XXYY.
The Remote and Local TSAPs are shown in this documentation using the same perspective as
Micro/WIN. That is, configure the TSAP’s with the same values in both driver and Micro/WIN. For
Configuration of Local TSAP refer to configuration of the worksheets.
Additional communication settings can be accessed in the Advanced Settings dialog. To open this
dialog, simply click the Advanced button in the Communication Settings dialog.
Simultaneous connection are supported on this driver for configuring this settings please check the
"Simutaneos Requests" field on the advanced settings dialog. The maximum supported
simultaneous connections are 32 and 16 per station.
4. Click OK to close the dialog.

Configuring the Driver Worksheet


This section explains how to configure a Standard Driver Worksheet (or Communication table) to
associate application tags with the PLC addresses. You can configure multiple Driver worksheets —
each of which is divided into a Header section and a Body section.
Use the following steps to create a new Standard Driver worksheet:
1. From the Studio development environment, select the Comm tab, located below the Workspace
pane.
2. In the Workspace pane, expand the Drivers folder, and right-click the SIETH subfolder.
3. When the pop-up menu displays, select the Insert option:

Note: To optimize communication and ensure better system performance, you must tie the tags in
different driver worksheets to the events that trigger communication between each tag group and the
period in which each tag group must be read or written. Also, we recommend configuring the
communication addresses in sequential blocks to improve performance.

Version: 10.15 17
SIETH Driver Guide Configuring the Driver

The SIETH.drv dialog displays (similar to the following figure):

In general, all parameters on the Driver worksheet (except the Station, Header and Address fields)
are standard for all communication drivers, and they will not be discussed in this publication. For
detailed information about configuring the standard parameters, consult the Studio Technical
Reference Manual.
Use the following information to complete the Station, Header, and Address fields on this worksheet:
Station field: Use this field to specify the IP Address, Rack, Slot and Local TSAP.

Syntax:
For S7-300, S7-400, S7-1200 and S7-1500:
<IP Address>:<Rack>:<Slot>[:<Port>]
The user may also prefix the syntax above with S7-300: or S7-400: if desired, however this is optional.
Examples
192.168.0.10:0:2
S7-300:192.168.0.10:1:1
192.168.0.10:0:1

Note:
The most common configuration for S7-300 and S7-400 is to have the CPU on the Slot number 2 of the
Rack 0. In that case, the Station would look like: <IP Address>:0:2

18 Version: 10.15
Configuring the Driver SIETH Driver Guide

As for the S7-1200 and S7-1500, usually the CPU is seen on the Slot number 1 of the Rack 0, which
would then cause the Station field to like: <IP Address>:0:1

For S7-200 and connected to the network via a CP243 module, and LOGO! use the syntax:
 S7-200:<IP Address>[:<Port>]
The port parameter is optional and defaults to 102.
 Or:
 S7-200:<IP Address>:<Port>[:<Local TSAP>]
The Local TSAP parameter is optional and default to 4D57. To include the Local TSAP, you must include
the Port number.

Examples:
S7-200:192.168.0.21
S7-200:192.168.0.21:102
S7-200:192.168.0.21:102:1100
S7-200:192.168.0.21:102:1200

Note:
The Remote and Local TSAP are configured in S7-200 using Micro/WIN’s Ethernet Wizard. In that
wizard, TSAP’s are configured in the format XX.YY. In SIETH driver, write these values as XXYY. The
Remote and Local TSAPs are shown in this documentation using the same perspective as Micro/WIN.
That is, configure the TSAP’s with the same values in both driver and Micro/WIN. For Configuration of
Remote TSAP refer to configuration of the driver settings.

Header field: Use the information in the following table to define the type of variables that will be read
from or written to the device and a reference to the initial address.
These variables must comply with the following syntax:
For Flags, Special Flags, Timers, Counters, Inputs and Outputs:
<Type>:<optAddressReference> (for example: M:1)
For Data Blocks:
<Type><TypeGroup>:<optAddressReference> (for example: DB2:1) or
<Type><TypeGroup>.DB :<optAddressReference> (for example: DB2.DB or DB2.DB:1)

Where:
<Type> is the register type. (M=Flags, SM=Special Flags, T=Timers, Z or C=Counters, E or I=Inputs, A
or Q=Outputs,
and DB=Data Blocks)
<TypeGroup> is the group number of the configured register type (for Data Block types only).
<optAddressReference> (optional) is the initial address reference of the configured group. If it is not
configured, it assumes the value 0 (zero). This number always refers to the Byte address number (see
the following table).

Version: 10.15 19
SIETH Driver Guide Configuring the Driver

Note: SIETH driver supports until 8 (eight) different stations, if you need more please contact your Studio
technical support representative

SIETH driver supports using hostnames in Station field.


The following table lists all of the valid initial address (reference) values for the SIETH driver:

Header Address SIETH Address

Byte Address Byte Address


Number Number Word Address Number

Byte 0 Byte 0
W0
Byte 1 Byte 1 W1
Byte 2 Byte 2
W2
Byte 3 Byte 3 W3
Byte 4 Byte 4 W4
Byte 5 Byte 5 W5
Byte 6 Byte 6
W6
Byte 7 Byte 7 W7
Byte 8 Byte 8
W8
Byte 9 Byte 9 W9
Byte 10 Byte 10
W10
Byte 11 Byte 11
The next table lists all of the data types and address ranges that are valid for the SIETH driver:

Header Field Information

Data
Types Sample Syntax Comments

Flags M:1 or M Logical Flags


Special SM:1 or SM Special Flags
Flags
Timers T:2 or T Timer Values
Counters Z:10 , C:10 or Z,C Counter Values
Inputs E:5 , I:5 or E,I Physical Input Values
Outputs A:8 , Q:8 or A,Q Physical Output Values
Data DB2:1, or DB2.DB or Data block values, where:
Blocks DB2.DB:1
Number following DB(2) specifies the data block number

20 Version: 10.15
Configuring the Driver SIETH Driver Guide

Header Field Information

Data
Types Sample Syntax Comments

Number following the colon specifies the word offset in the


data block
The Valid Range of Initial Addresses for all the above data types varies according to the equipment.
Address field: Use the information provided in the following table to associate each tag to its respective
device address.
Type the tag from your application database into the Tag Name column. This tag will receive values from
or send values to an address on the device. The address must comply with the following syntax:
[Signed/Unsigned]<Format><AddressOffset>.<Bit> (for example: X10.2)
<Format><AddressOffset>.<Len> (for example: ST2.10, SST2.10) – String format only
Where:
[Signed/Unsigned] (optional parameter used for integer values only): If you do not specify this
parameter, Studio inserts an integer value based on the parameters you set in the Communication
Parameters dialog. Valid values are S (signed) and U (unsigned). Dword does not use U (unsigned).
<Format> defines how Studio treats the value read or written from/to the device.
(X=Bit, B=Byte or Bit, W=Word, D or DW=Dword, F=Float, ST=String, SST= S7 String format).
For Data-Blocks:
T=Timer Format (S5T), TS=Timer in String format (hh:mm:ss:ms), C=Counter Format
<AddressOffset> is a parameter added to the AddressReference parameter (configured in the Header
field) to compose the group address configured in the Header field.
<Bit> is the bit number (from 0 – 7) from the Byte address. This parameter is optional, and it is supported
only when the format is Byte or Bit(B or X).
<Len> is the length to read or to write. It is in bytes. String format only.

Note: T, TS and C data formats are most used for Data-Blocks operand, however they can be used for
all operands.

Sample Address Configuration


Address on the Device Header Field Address Field
M (Word 5 = Byte 5 / Byte 6 / M W5
String 7, Length 10)
M:5 W0
M:3 W2
M (Byte 5) M B5
M:5 B0
M:1 B4
M (Byte 6) M 6
M:6 0
M:3 B3

Version: 10.15 21
SIETH Driver Guide Configuring the Driver

Sample Address Configuration


Address on the Device Header Field Address Field
M (String 7, Length 10) M ST7.10
SM (Word 5 = Byte 5 / Byte 6 / SM W5
String 7, Length 10)
SM:5 W0
SM:3 W2
SM (Byte 5) SM B5
SM:5 B0
SM:1 B4
SM (Byte 6) SM B6
SM:6 B0
SM:3 B3
SM (String 7, Length 10) SM ST7.10
SM:7 ST0.10
SM:4 ST3.10
T (33) T 33
T:30 3
T33 T0
T(35) T TS35 (string format)
T:35 0
T31 4
C (3) C 3
C:3 C0
C:2 1
C (4) C 4
C:4 0
C:2 2
DB5 (Word 2 = Byte 2 / Byte 3 DB5:0 W2
/ String 4 length 10)
DB5:2 W0
DB5:1 W1
DB5 (Byte 2) DB5.DB B2
DB5:2 B0
DB5:1 B1
DB5 (Byte 3) DB5.DB:0 B3
DB5:3 B0

22 Version: 10.15
Configuring the Driver SIETH Driver Guide

Sample Address Configuration


Address on the Device Header Field Address Field
DB5:2 B1
DB5 (String 4 length 10) DB5:0 ST4.10
DB5:4 ST0.10
DB5:2 ST2.10
DB5 (S7-String Format, DB5:0 SST4.10
length 10)
DB5:4 SST0.10
DB5:2 SST2.10
DB5 (Word 7 = Byte 7 / Byte 8 DB5:0 W7
/ Double Word 3)
DB5:7 W0
DB5:4 W3
DB5 (Byte 7) DB5:0 B7
DB5:7 B0
DB5:4 B3
DB5 (Address 8) DB5:0 C8 (counter format)
DB5:8 T0 (timer format)
DB5:4 TS4 (timer string format)
DB5 (Double Word 3) DB5.DB D3
DB5:0 DW3
DB5.DB:2 DW1
Input (Address 1, bit 4) I:0 or E:0 X1.4
I:1 or E:1 X0.4
I:0 or E:0 B1.4
Input (Byte 1) I:0 or E:0 B1
I:1 or E:1 B0
Output(Address 1, bit 4) Q:0 or A:0 X1.4
Q:1 or A:1 X0.4
Q:0 or A:0 B1.4
Output(Byte 1) Q:0 or A:0 B1
Q:1 or A:1 B0

Attention: You must not configure a range of addresses in the same worksheet that is greater than the
maximum block size (data buffer length) supported by the protocol. The maximum data buffer length for
this driver is 1024 bytes in each Standard Driver worksheet.
If you are using a S7-200 the block size restrictions are different than for other families. For timers the
limitation is of 12 operands, counters are limited on 21 operands and the other headers are limited on 64
bytes.

Version: 10.15 23
SIETH Driver Guide Configuring the Driver

Main Driver Sheet (MDS)


When the driver is inserted into the application, the MAIN DRIVER SHEET is automatically added to the
driver folder.

The MAIN DRIVER SHEET provides a simple way to associate Studio tags to addresses in the PLC.
Most of the MAIN DRIVER SHEET entries are standard for any driver. Refer to the Studio Technical
Reference Manual about the configuration of the standard fields. The fields that require specific syntax
for this driver are described below:

Station field: Use this field to specify the IP Address, Rack, Slot and Local TSAP.
Syntax:
For S7-300, S7-400, S7-1200 and S7:1500
<IP Address>:<Rack>:<Slot>[:<Port>]
The user may also prefix the syntax above with S7-300: or S7-400: if desired, however this is optional.
Examples
192.168.0.10:0:2
S7-300:192.168.0.10:1:1
192.168.0.10:0:1
Note: The most common configuration for S7-300 and S7-400 is to have the CPU on the Slot number 2
of the Rack 0. In that case, the Station would look like: <IP Address>:0:2

24 Version: 10.15
Configuring the Driver SIETH Driver Guide

As for the S7-1200 and S7-1500, usually the CPU is seen on the Slot number 1 of the Rack 0, which
would then cause the Station field to like: <IP Address>:0:1
If the device is a S7-200 connected to the network via a CP243 module, or a LOGO!, use the syntax:
 S7-200:<IP Address>[:<Port>]
The port parameter is optional and defaults to 102. Or:
 S7-200:<IP Address>:<Port>[:<Local TSAP>]
The Local TSAP parameter is optional and default to 4D57.
Examples:
192.168.0.10:0:2
S7-300:192.168.0.10:1:1
S7-200:192.168.0.21
S7-200:192.168.0.21:102
S7-200:192.168.0.21:102:1100
S7-200:192.168.0.21:102:1200
S7-200:192.168.0.21:102:1700
Note: The Remote and Local TSAP are configured in S7-200 using Micro/WIN’s Ethernet Wizard. In that
wizard, TSAP’s are configured in the format XX.YY. In SIETH driver, write these values as XXYY. The
Remote and Local TSAPs are shown in this documentation using the same perspective as Micro/WIN.
That is, configure the TSAP’s with the same values in both driver and Micro/WIN. For Configuration of
Remote TSAP refer to configuration of the driver settings.

 I/O Address: Address of each register from the PLC. The syntax used in this field is described
below:
For Flags, Special Flags, Timers, Counters, Inputs and Outputs:
<Type>[Signed/Unsigned]<Format><Address>.<Bit> (for example: MB10.2)
<Type><Format><Address>.<Len> (for example: MST2.10) – String format only
For Data Blocks:
<Type><TypeGroup>[Signed/Unsigned]<Format><Address>.<Bit> (for example: DB2W1)
<Type><TypeGroup>.DB[Signed/Unsigned]<Format><Address>.<Bit> (for example: DB2.DBB1,
DB2.DBUB5, DB2.DBD20)
<Type><TypeGroup><Format><Address>.<Len> (for example: DB2:ST2.10) – String format only

Where:
[Signed/Unsigned] (optional): Parameter used for integer values only. If you do not specify this
parameter, Studio uses the Communication Parameters settings to configure integers.
Valid values for this parameter are S (Signed) or U (Unsigned). Dword does not use U (Unsigned).
<Type> is the register type. (M=Flags, SM=Special Flags, T=Timers, Z or C=Counters, E or I=Inputs, A
or Q=Outputs,
and DB=Data Blocks)
<TypeGroup> is the group number of the configured register type (for Data Block types only).
<Address> is the device address. This number always refers to the Byte address number.

Version: 10.15 25
SIETH Driver Guide Configuring the Driver

<Format> defines how Studio treats the value read or written from/to the device (X=Bit, B=Byte or Bit,
W=Word, D or DW=DWord, F=Float, ST=String). (String format does not support bits)
For Data-Blocks:
T=Timer Format (S5T), TS=Timer in String format (hh:mm:ss:ms), C=Counter Format
<Bit> is the bit number (from 0 – 7) from the Byte address. This parameter is optional, and it is supported
only when the format is Byte or Bit (B or X).
<Len> is the length to read or to write. It is in bytes. String format only.

Note:
SIETH driver supports until 8 (eight) different stations, if you need more please contact your Studio
technical support representative
SIETH driver supports using hostnames in Station field.
T, TS and C data formats are most used for Data-Blocks operand, however they can be used for all
operands.

26 Version: 10.15
SIETH Driver Guide

C HAPTER 5
Executing the Driver
After adding the SIETH driver to a project, Studio sets the project to execute the driver automatically
when you start the run-time environment.
To verify that the driver run-time task is enabled and will start correctly, perform the following steps:
1. Select Project → Status from the main menu bar.
The Project Status dialog displays:

2. Verify that the Driver Runtime task is set to Automatic.


3. If the setting is correct, click OK to close the dialog.
4. If the Driver Runtime task is set to Manual, select the Driver Runtime line. When the Startup
button becomes active, click the button to toggle the Startup mode to Automatic.
5. Click OK to close the Project Status dialog.
6. Start the application to run the driver.

Version: 10.15 27
SIETH Driver Guide

C HAPTER 6
Troubleshooting
If the SIETH driver fails to communicate with the device, the tag you configured for the Read Status or
Write Status fields will receive an error code. Use this error code and the following table to identify what
kind of failure occurred.

Error
Description
Code

-33 Invalid INI file


-34 Invalid Address
-36 Invalid Data Type
-38 Invalid Station
-39 Invalid Block Size
0 OK
1 Error to initialize driver
2 Maximum number of connections was exceeded.
53 Invalid Message
60 Handshake Error
61 Invalid Connection
62 Invalid Message
244 Function is not supported
245 Internal error, please check
246 Listed job number is invalid
247 At least one parameter for opening the device is invalid
248 No free space in the request queue
249 The necessary class cannot be initialized
250 The necessary memory cannot be allocated
251 Device is not open
252 Device was not found
253 Device is already in use, open, or update is not valid
254 Function is not valid
255 End of program request
256 A parameter was not in the defined range
508 Not all parameters can be changed because the adapter is already initialized

Version: 10.15 29
SIETH Driver Guide Troubleshooting

Error
Description
Code

509 The program "AGLink_Config.EXE" cannot be started


510 The parameters were changed because of plausibility checks
511 Parameter length is not supported
512 Requested option is not available
752 Sending buffer too small for packet
753 Receiving buffer too small for packet
754 Timeout while waiting for DLE after sending the packet
755 Packet to be sent is not correct (length 0 or NULL pointer)
756 After STX arbitrary information was sent instead of DLE
757 After STX NAK was sent instead of DLE
758 Timeout after initialization conflict (both have high priority)
759 Timeout while waiting for DLE after sending STX
760 Initialization conflict
761 Wrong protocol status
762 Checksum error
763 Timeout while waiting for checksum
764 Information after DLE was not DLE or ETX
765 Timeout while waiting for packet information (ZVZ)
766 Timeout while waiting for beginning of packet (QVZ)
767 Wrong information received instead of STX
768 Timeout while waiting for STX at the beginning of the program
1019 Adapter is not initialized
1020 Unknown error message from adapter
1021 Wrong MPI baud rate
1022 The address code is higher than HAS
1023 Requested adapter address already exists
1024 Received packet has wrong content
1260 Type (of data) is not supported
1261 Access to object is not permitted
1262 Invalid address
1263 Context is not supported
1264 PLC sends no data
1265 Function protection level is not sufficient
1266 Context is not supported

30 Version: 10.15
Troubleshooting SIETH Driver Guide

Error
Description
Code

1267 Information cannot be determined at the moment


1268 Unknown error message from PLC, please check
1269 Wrong size operands or selected range too large
1270 Wrong operating status of PLC
1271 Error while restarting the PLC
1272 Error while starting the PLC
1273 Wrong PLC operating status
1274 Internal error, please check
1275 No data available (for example, missing DB)
1276 Hardware error (for example, nonexistent peripheral equipment)
1277 Number of frame does not fit
1278 PLC was not found
1279 No additional connection possible
1280 No connection to the requested PLC
1523 DSR signal changed to 0 (modem disconnected)
1524 DCD signal changed to 0 (no carrier)
1525 No connection to remote terminal
1526 No modem found at the device
1527 Error during initialization of auto-answer
1528 Error during initialization of dial tone
1529 Error during initialization of selection procedure
1530 Error during initialization sequence 4
1531 Error during initialization sequence 3
1532 Error during initialization sequence 2
1533 Error during initialization sequence 1
1534 Error during basis initialization (AT&FE0V1)
1535 Modem cannot hang up
1536 General modem error
1786 CIF card not logged in on the logical ring (bus)
1787 A resource error exists
1788 Wrong firmware version of CIF card
1789 Wrong hardware version of CIF card
1790 Error in a device driver function
1791 Requested board not found

Version: 10.15 31
SIETH Driver Guide Troubleshooting

Error
Description
Code

1792 Requested device driver not found


2038 Close received instead of ReadOK
2039 Timeout while reading IP
2040 Error while reading IP
2041 Close received instead of WriteOK
2042 Timeout while writing IP
2043 Error while writing IP
2044 Close received instead of ConnectOK (for example, wrong rack or slot number)
2045 Timeout while establishing IP connection
2046 Error while establishing IP connection
2047 Listed IP address invalid
2048 Socket cannot be opened

Tip:
You can verify communication status using the Studio development environment Output window
(LogWin module). To establish an event log for Field Read Commands, Field Write Commands, and
Protocol Analyzer, right-click in the Output window. When the pop-up menu displays, select the option
to set the log events.
If you are unable to establish communication with the PLC, try to establish communication between the
PLC Programming Tool and the PLC.
Try pinging the PLC, or telnet to the default port, which is usually 102.
Quite frequently, communication is not possible because you have a hardware or cable problem, or a
PLC configuration error. After successfully establishing communication between the device’s
Programming Tool and the PLC, you can retest the supervisory driver.
If you must contact us for technical support, please have the following information available:
Operating system (type and version): To find this information, select Tools → System Information.
Project Information: To find this information, select Help → Support Information.
Driver version and communication log: Displays in the Studio Output window when the driver is
running.
Device model and boards: Consult the hardware manufacturer’s documentation for this information.

32 Version: 10.15
SIETH Driver Guide

C HAPTER 7
Revision History
Driver Date Description of Changes
Version

1.00 15 Jun 04 First version


1.01 26 Jun 04 Fixed bug with bit writing and reading
1.02 29 Sept 04 Fixed bug in the MDS with DB data type
1.04 19 Oct 05 Fixed bug on mapping functions. Changed from (AGLINK_API) to
(WINAPI)
1.05 28 Mar 06 Fixed problems in function GetBit

1.06 11 Jul 06 Implemented String format


Implemented the Unsigned and Signed options
1.07 07 Dec 06 Created Initial ID to Connection (to use more than one driver)
Implemented "Initial ID Connection" field in Communication Parameters
3.00 26 Feb 08 Data types X and D (equivalent to Bit and DWord) were created.
Driver was changed for Colon ( : ) to be optional in MAIN DRIVER SHEET
New syntaxes to Data Blocks operand were added.
Included TS data type (Timer in string format)
Included Special Flags operand (SM).
3.01 24 Apr 08 Fixed problem with multiple stations.
10.1 07 Jan 09 Updated driver version, no changes in the contents.
10.3 21 Apr 09 Modified the driver to support SST format
10.4 02 Dec 09 - Modified the driver to create less communication groups and optimize
the communication
10.5 01 Apr 10 Fixed problem when communicating with multiple stations
10.6 21 Jul 10 - Siemens drivers are allowed to coexist on the same application
- Added support to S7-200 ethernet communication via CP243 module
- Fixed virtual group separation
10.7 1 Jul 2011 - Fixes on block size check
10.8 12 Mar 2013 - Included configuration of Remote and Local TSAP for S7-200.
- Fixed issues with subnets
- Fixed issues with Bit writing on S7-200
- Fixed address offset issue when above 10000

Version: 10.15 33
SIETH Driver Guide Revision History

- Fixed a communication issue with WinAC SoftPLC


10.8 4 Jun 2013 - Updated documentation to show the configuration for S7-1200/1500 and
Logo! No changes in the driver
10.8 8 Oct 2013 - Updated documentation of the S7-300 and S7-400 station examples to
use Rack 0 and Slot 2.
10.9 16 Oct 2014 - Added support to Simultaneous Connections
- Removed Initial Connection ID field
10.9 17 Apr 2015 - Updated documentation only. No changes in the driver
10.10 10 Jan 2017 - Added support to using hostnames in the station field.
- Changed INI file to increase range allowed for DB header
10.11 10 Feb 2017 -Fixed issue of driver not running on CE devices after previous release.
10.12 23 Aug 2017 - Fixed issue of reading long reals or double floats with poor precision
and now they read as 64 bit reals
10.13 23 Aug 2018 - Added support for PLC port in station parameters
10.14 08 Feb 2019 -Build issues fixed and driver version incremented. No change in the
driver.
10.15 17 Aug, 2021 Changed AGLINK (third party API) dependencies.

34 Version: 10.15