CHESS Pro XC-B233-E-R1M01

SYSTEM PARAMETERS
System Type XC-B233-E-R1M01

DC Side

Cell Type LFP C15

Battery energy storage system for storage Cell Capacity 320Ah

and charging, suitable for all kinds of EV Pack Type 1P57S


charging and battery swapping stations.
String Type 1P228S(4 battery packs)

System Configuration 1P228S

Battery Nominal Capacity (BOL) 233kWh

DC Usable Energy (BOL)@FAT 215kWh

SYSTEM FEATURES DC Usable Energy (BOL) @SAT (within 3 months after FAT) 208kWh

Liquid Cooling & Excellent Performance


Battery Voltage Range 592.8~820.8V

Using liquid cooling technology, cell-level intelligent temperature control ensures smooth operation. Ultra-long
cycle life, product performance is greatly improved.
Nominal Charge/Discharge Power 100kW/200kW

General Parameters

Highly Integrated & Safe and Reliable Dimensions(W×D×H) 1500×800×2250mm


Integrate HVAC, FSS and BMS to monitor the operation status in real time in an all-round way, making it more
efficient and safer. Weight ≤2600kg

IP Rating IP54(Electrical parts); IP65(battery part)


High-efficiency fast charging & Wide range of applications
Efficient charging and fast discharging, applicable to high-power fast-charging scenarios of electric vehicles.
Operating Ambient Temperature -25°C~+55°C 【1】
Simple and streamlined scalable design for extensive application scenarios.
Storage Temperature -20~35°C (<12 months);-20~45°C (<3months)

CIRCUIT DIAGRAM
Relative Humidity 5%~95%

Max. Working Altitude 3000m

Cooling Concept liquid cooling

Ethernet
Noise ≤75dB(A)@1m
Smart HVAC

Aux. Power Fire Suppression System Aerosol


DMC

FSS E-stop Aux. Power Interface AC230V/50Hz

Aux. System Peak Power Requirement @45℃ 5kW


Charge Pile/
Cabinet Communication Interfaces Ethernet


Battery String Communication Protocols Modbus TCP/IP

Compliance IEC62619

-
BMS

Standard Color Front: MD458-3JA0-0; Side: RAL9011

Note:
【1】Power derating is performed when the ambient temperature is above 45℃.