Base Material Installation Anchor Plate: 2 CK, Cube

Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Base material Installation


No stand-off Installation.
Concrete: Cracked
Thickness of base material 500 mm Anchor plate
Strength Class C20/25 Assumed rigid plate
fck,cube 25 N/mm2 Thickness of the plate 8 mm
Plate shape Rectangle
Side length 150 X 65 mm

Plate vertex Anchors Position

Vertex x y Anchor x y Slotted -x Slotted -y


1 -75.0 -32.5 1 -50.0 0.0
2 -75.0 32.5 2 50.0 0.0
3 75.0 32.5
= Slotted
4 75.0 -32.5

Profile
Selected Profile No Profile has been applied
Eccentricity X: 0.0 mm
Y: 0.0 mm

Selected Products
Anchor (name) MTP anchor
Approval ETA 12/0397
Size M8 x 75
Article code AP08075
Coating/Material Zinc plated

-
-

Anclajes // Anchors // Chevilles // Dübel //


20/05/2024 Page: 1 / 10
v. 5.1.8.135 - Database 2492.9.4151160749
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Anchor data
d Anchor/thread diameter: 8.0 mm tfix Thickness of fixture: 8.0 mm
dnom Outside diameter of anchor: 8.0 mm SW Spanner: 13.0 mm
d0 Drill hole diameter: 8.0 mm Tinst Max setting torque 20.0 Nm
h1 Depth of drilled hole: 60.0 mm
hnom Setting depth: 55.0 mm
hef Effective anchorage depth: 48.0 mm
df Diameter of clearance hole in fixture: 9.0 mm

PRODUCT:
MTP anchor in zinc plated.

CALCULATION METHOD:
This calculation method is based in specific values exclusively for MTP. Any modifications made --this being change of product brand
or changes in physical conditions of design-- require recalculation of the design

ANCHOR PLATE:
The design program assumes, in accordance with the design code, that the anchor plate does not deform as a result of applied
actions. Thus, in accordance with the design code, the anchor plate shall be sufficiently stiff and its design should be carried out
according to standards for steel structure ensuring elastic behavior.

INSTALLATION:
All conditions of the European Technical Assessment (ETA) and Index technical publications shall be complied with in all details.

ADDITIONAL PROOFS:
With regard to design of anchorages one shall to be aware of the additional proofs for ensuring the characteristics resistance of the
concrete member (structural component) described in the design code.

Anclajes // Anchors // Chevilles // Dübel //


20/05/2024 Page: 2 / 10
v. 5.1.8.135 - Database 2492.9.4151160749
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Input Data
Tension Bending
NSd,Z 0.00 kN MSd,X 0.01 kN·m
MSd,Y 0.07 kN·m

Shear Torsion
VSd,X 0.70 kN MSd,Z 0.00 kN·m
VSd,Y -0.17 kN

Edges Reinforcement
CXp 50 mm Diameter 11 mm
CXn 50 mm Distance rebars 200 mm
CYp ∞ mm Distance stirrups 200 mm
CYn ∞ mm Edge reinforcement No
Reinforcement to resist No
Design standard splitting and to limit crack

ETAG

Anclajes // Anchors // Chevilles // Dübel //


20/05/2024 Page: 3 / 10
v. 5.1.8.135 - Database 2492.9.4151160749
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Calculated design loads on anchor(s)

Tension force Shear force Shear force (x) Shear force (y)
Anchor
[kN] [kN] [kN] [kN]
1 0.62 0.36 0.35 -0.09
2 0.00 0.36 0.35 -0.09

Resultant tension force: 0.62 [kN]


Resultant compression force: 0.62 [kN]
Resultant shear force: 0.72 [kN]

Calculation of Utilizations according to: ETAG 001, Annex C - Method A


(β- is the ratio between design load and design resistance)

Calculation of Utilisations - Tension loads

Tension - Steel Failure

NRk,s γM,s NRd,s NSd βN,s


Anchor
[kN] [-] [kN] [kN] [%]

18.10 1.50 12.07 1 0.62 5.1%

2 0.00 0.0%

The steel failure verification is performed for all forces active on anchors including compression. It is suggested to verify
the buckling of the anchor and the punching of concrete slab separately, since they are not accounted in the
verifications. When loaded by compression load, the fastener should be designed as a steel element according to EN
1993-1-8.

Anclajes // Anchors // Chevilles // Dübel //


20/05/2024 Page: 4 / 10
v. 5.1.8.135 - Database 2492.9.4151160749
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Tension - Pull Out Failure

NRk,p γM,p ψc NRd,p NSd βn,p


Anchor
[kN] [-] [-] [kN] [kN] [%]
5.00 1.8 1.00 2.78
1 0.62 22.4%

2 0.00 0.0%

Tension - Concrete Cone Failure


NRk,c=N0Rk,c · ψA,N · ψs,N · ψre,N · ψec,N

hef scr,N ccr,N fck,cube γMc


[mm] [mm] [mm] [N/mm²] [-]
48.0 144 72 25 1.8

The anchors are divided into 1 group

Group N0Rk,c Ac,N A0c,N hef scr,N ccr,N c-x c+x c-y c+y
Anchor
No. [kN] [mm²] [mm²] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

1 [1, 2] 11.97 28,800 20,736 48.0 144 72 50 50 6,000 6,000

Group ψs,N ψre,N eN,x eN,y ψec,N NRk,c NRd,c Nsd βN,c
Anchor
No. [-] [-] [mm] [mm] [-] [kN] [kN] [kN] [%]

1 [1, 2] 0.908 1.000 38.9 0.0 0.649 9.80 5.45 0.62 11.4%

Tension - Splitting Failure


NRk,sp=N0Rk,c · ψA,sp · ψs,sp · ψre,sp · ψec,sp · ψh,sp

Thickness of base material = 500.0 mm Required minimum thickness = 100.0 mm

hef fck,cube ψc hmin scr,sp ccr,sp γM,sp


[mm] [N/mm2] [-] [mm] [mm] [mm] [-]
48.0 25 1.000 100 288 144 1.8

The anchors are divided into 1 group

Group N0Rk,c hef Ac,sp A0c,sp scr,sp ccr,sp c-x c+x c-y c+y
Anchor
No. [kN] [mm] [mm²] 2
[mm ] [mm] [mm] [mm] [mm] [mm] [mm]

1 [1, 2] 11.97 48.0 57,600 82,944 288 144 50 50 6,000 6,000

Group ψs,sp ψre,sp eNx eNy ψec,sp ψh,sp NRk,sp NRd,sp NSd βN,sp
Anchor
No. [-] [mm] [mm] [mm] [-] [-] [kN] [kN] [kN] [%]

Anclajes // Anchors // Chevilles // Dübel //


20/05/2024 Page: 5 / 10
v. 5.1.8.135 - Database 2492.9.4151160749
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

1 [1, 2] 0.804 1.000 3.0 0.0 0.980 1.500 9.82 5.458 0.62 11.4%

Calculation of Utilisations - Shear loads


Shear - Steel Failure Without Lever Arm

V0Rk,s VRk,s γMs VRd,s


[kN] [kN] [-] [kN]

11.00 11.00 1.25 8.80

1 2

Vsd [kN] 0.36 0.36

βV,s [ % ] 4.1% 4.1%

Shear - Steel Failure With Lever Arm

No lever arm has been applied

Anclajes // Anchors // Chevilles // Dübel //


20/05/2024 Page: 6 / 10
v. 5.1.8.135 - Database 2492.9.4151160749
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Shear - Pryout Failure(NRk,c)


NRk,c=N0Rk,c · ψA,N · ψs,N · ψre,N · ψec,V,cp

VRk,cp=k · NRk,c

hef scr,N ccr,N fck,cube k γMc


[mm] [mm] [mm] [N/mm²] [-] [-]
48.0 144 72 25 1.00 1.5

The anchors are divided into 1 group

Group N0Rk,c Ac,N A0c,N ψs,N ψre,N c-x c+x c-y c+y
Anchor
No. [kN] [mm ] 2
[mm ] 2
[-] [-] [mm] [mm] [mm] [mm]

1 [1, 2] 11.97 28,800 20,736 0.908 1.000 50 50 6,000 6,000

Group eN,x eN,y ψec,N NRk,c VRk,cp VRd,cp VSd βV,cp


Anchor
No. [mm] [mm] [-] [kN] [kN] [kN] [kN] [%]

1 [1, 2] 0.0 0.0 1.000 15.10 15.10 10.07 0.72 7.2%

Shear - Concrete Edge Failure

VRk,c=V0Rk,c · ψA,V · ψs,V · ψh,V · ψα,V · ψec,V · ψre,V

hef fck,cube d γVrkc


[mm] [N/mm²] [-] [-]
48.0 25 8 1.5

Edge"Xn"
Case: [1]
Shear force[kN]
Anchor Q Qx Qy
1 0.09 0.00 -0.09
2 0.09 0.00 -0.09

Anclajes // Anchors // Chevilles // Dübel //


20/05/2024 Page: 7 / 10
v. 5.1.8.135 - Database 2492.9.4151160749
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Group c1 c2min k1 V0Rk,c Ac,V A0c,V ψs,V


Anchor Failure line Edge
No. [mm] [mm] [-] [kN] [mm²] [mm²] [-]

1 [1] [1] Xn 50 6,000 1.7 4.82 11,250 11,250 1.000

2 [2, 1] [1] Xn 150 6,000 1.7 21.79 101,250 101,250 1.000

Group ψh,V ψα,V ev ψec,V ψre,V VRk,c VRd,c Vsd βV,c


Anchor
No. [-] [-] [mm] [-] [-] [kN] [kN] [kN] [%]

1 [1] 1.000 2.500 0 1.000 1.000 12.05 8.03 0.09 1.1%

2 [2, 1] 1.000 2.500 0 1.000 1.000 54.47 36.31 0.17 0.5%

Edge"Xp"
Case: [2]
Shear force[kN]
Anchor Q Qx Qy
1 0.09 0.00 -0.09
2 0.71 0.70 -0.09

Group c1 c2min k1 V0Rk,c Ac,V A0c,V ψs,V


Anchor Failure line Edge
No. [mm] [mm] [-] [kN] [mm²] [mm²] [-]

1 [2] [2] Xp 50 6,000 1.7 4.82 11,250 11,250 1.000

2 [1, 2] [2] Xp 150 6,000 1.7 21.79 101,250 101,250 1.000

Anclajes // Anchors // Chevilles // Dübel //


20/05/2024 Page: 8 / 10
v. 5.1.8.135 - Database 2492.9.4151160749
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Group ψh,V ψα,V ev ψec,V ψre,V VRk,c VRd,c Vsd βV,c


Anchor
No. [-] [-] [mm] [-] [-] [kN] [kN] [kN] [%]

1 [2] 1.000 1.006 0 1.000 1.000 4.85 3.23 0.71 21.8%

2 [1, 2] 1.000 1.024 0 1.000 1.000 22.31 14.88 0.72 4.8%

When plate geometry and anchors layout are not covered by the selected design method, the edge
failure calculation is carried out on all possible subgroups made of two anchors only. Additionally only
the anchor row closer to the considered edge, which could consist in one anchor only, is assumed to
take up entirely the shear load. The reported results are referred to the most unfavorable conditions.
Please refer to the ACP-Method I design guide for more information.

Combined tension and shear

Anchor Tension (βN) Shear (βV) Condition Utilisation Status

Steel 1 5.1% 4.1% β = β2N + β2V 0.4%

Concrete 1 22.4% 7.2% β = (β1.5N + β1.5V) 12.5%


Anchor

βN,s βN,p βN,comb βN,c βN,sp βV,s βV,sla βV,cp βV,c βN,s,max βV,s.max βN,c,max,E βV,c,max,E βcombi,s,E βcombi,c,E

1 5.1% 22.4% 0.0% 11.4% 11.4% 4.1% 0.0% 7.2% 4.8% 5.1% 4.1% 22.4% 7.2% 0.4% 12.5%

2 0.0% 0.0% 0.0% 11.4% 11.4% 4.1% 0.0% 7.2% 21.8% 0.0% 4.1% 11.4% 21.8% 0.2% 14.0%

βN,s,max = βN,s
βV,s,max = max ( βV,s , βV,sla )

βN,c,max,E = max ( βN,p , βN,c , βN,sp , βN,comb )


βV,c,max,E = max ( βV,cp , βV,c )
βcombi,s,E = β2N,s + β2V,s
βcombi,c,E = min[ ( β1.5N,c,max,E + β1.5V,c,max,E), ( βN,c,max,E + βV,c,max,E ) / 1.2 ]

With consideration of related anchors and separation of steel and concrete failure

Anclajes // Anchors // Chevilles // Dübel //


20/05/2024 Page: 9 / 10
v. 5.1.8.135 - Database 2492.9.4151160749
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

RESULT
Ok. The product meets the design criteria

REMARKS
The verification of anchor design cases covered by ETAG 001 or TR029 is performed according to the selected Guideline. The
verification of anchor design cases non-covered by guidelines is based on the selected Guideline. Further information can be
found inside ACP Design Guides. The loads acting on anchors are evaluated according to the theory of elasticity, assuming
that the anchor plate does not deform under the design actions. To ensure the validity of this assumption the anchor plate
shall be sufficiently stiff. The user must verify this condition, since the base plate stiffness is not automatically calculated by
the software. The transfer of loads from anchors into base material must be verified in accordance with ETAG 001 Annex C or
TR029 Section 7. The design method is valid only for clearance hole in the fixture with a diameter not larger than the values
given in ETAG 001 Annex C or TR029 Table 4.1. Partial safety factors are applied according to product ETA and relevant design
documents, please verify according to national regulations and requirements.

IMPORTANT NOTICE
The data input to this software, and the relative results, must be checked by the user under the responsibility of an engineer
experienced in anchorages and concrete work. This is to ensure there are no errors and all data is complete and accurate and
complies with all rules and regulations for the actual conditions and application.
The data contained in this software relates only to the product illustrated therein and is based on principles, formulas and
safety regulations according to the existing guidelines for anchorages into concrete, together with the knowledge of the
manufacturer.
The user must comply with these principles. The user is solely responsible for the data entered into the program and any
errors or omissions are the responsibility of the user. The user must ensure that the most current version of the program is
installed by way of the auto-updating function offered by the manufacturer.
The user must update the program when instructed to do so.
The aim of the program is to act as a calculation aid and to assist in complying with current regulations and guidelines,
without any guarantee of suitability for any specific application.

Anclajes // Anchors // Chevilles // Dübel //


20/05/2024 Page: 10 / 10
v. 5.1.8.135 - Database 2492.9.4151160749

You might also like