Concerns from
*
12 to 33 kW power boilers
Sp. z o.o.
5 th C l a s s ( P N – E N 3 0 3 - 5 : 2 0 1 2 )
both at 30% as well as 100% power
Ve r y s m a l l d i m e n s i o n s
420 L
44-100 kW
150 L
17-33 kW
80 L
12 kW
TECHNICAL-EXPLOITATION DATA TABLE FOR FUWI PELLET BOILERS
Minimal boiler power kW 3,5 4,9 7,2 10,0 13,2 16,2 24,0 28,4
Heating surface M2 40-120 100-170 171-240 241-330 331-440 441-550 551-800 801-1000
Weight of boiler and tank KG 160 220 260 300 440 470 560 590
Height from base to the ue middle CM 94 125 125 125 138 138 138 138
FUNCIONALITY
Modern and compact construction, allows for montage of device in small rooms. Automatic corrects
the fuel dosage and fan power automatically, by smooth modulation of the burner power
from 30% up to 100%. High functionality provided by automation of the dosage and fuel ring-up.
SAFETY
Safety system allows for functioning in open and closed heating circuits.
+ Boiler at 85 Celsius degrees turns on all of the pumps and valves. At 90 Celsius degrees,
independent boiler protection STB turns on, disabling the feeder, fan and igniter. Temperature
sensor prevents feeder overheating, turning on the alarm at 45 Celsius degrees.
Additionally Plex pipe prevents re comeback to the fuel tank.
ECOLOGY
Long-term ecological effect – reduction of CO2 emission, resulting from usage of recommended
ecological biomass fuel which is Pellet. Fuel includes very small amount of residues (1 – 3%)
in the form of ash. It may be used, f. ex. in garden.
ECONOMY
Average usage of pellet in period of 7 months of heating season is approximately 3 tons for 100 m2
surface building, while maintaining the requirements of heat transfer coefcient of buildings.
CONSTRUCTION TOP CLEANING
AND OPTIONS
Automatic system of pneumatic cleaning
of the exhaust ue tubes with compressed air.
Fully automatic process ensures its patency in
period of boiler exploitation.
AUTOMATICS
Advances automatics dedicated for most
developed heating boilers, along with clear
controller. Allows for full exploitation process
control with several options for increasing
comfort of using.
BURNER
Dedicated FU-WI pellet burner, centrally
located under the heat exchanger.
Construction allows for even burning of
delivered fuel on its whole surface.
Patent RP no 208898.
BOTTOM CLEANING
Through mobile phone you may also read the current boiler parameters, as well as change the
settings. SIM card is used for GSM connection, and it may be bought
from any mobile network operator
EXPANSION MODULE
Expansion modules communicate with main controller through reliable
CAN main line. Modular construction allows for adjusting of controller
to the heating system requirements.
Up to 16 heating circuits
2 hot water circuits
Buffer tank
Solar system
ROOM
REGULATOR videROOM FUNCIONALITY
room temperature regulation
weekly time program
economic mode
comfortable program
anti-freeze mode
Used touch screen TFT and capacitive touch technology Automatic synchronization of the day and hour
known from modern smartphones, provide high service with boiler driver
comfort. By gesture recognition, such as nger dragging weather forecast
or moving, device handling becomes more simple and monitoring of the boiler, buffer, CH
intuitive. Communication with boiler drivers is carried out and HW circuits work
with CAN bus. It is distinguished by transmission high
monitoring of the solar panels work.
reliability and maximal connection length up to 1000m.
alarms reading from the boiler driver
Micro SD card connector parental lock
provides an easy software update
E-mail notication about new alarms - each driver Connection is very simple and comes down to
connecting the wires accordingly to the scheme.
alarm is immediately sent to indicated
Registration of the heating system on igneo.pl
by user e-mail address. service is equally simple.
C O N T A C T
+48 55 232-65-38
+48 55 236-16-00
[email protected] information
[email protected] service
WWW.F U W I . P L
FU-WI Sp. z o. o.
ul. Grochowska 5B
82-300 Elbląg
Warmińsko-Mazurskie